C200HW-DRT21, CQM1-DRT21, DRT1 Series DeviceNet Slaves Operation Manual: W347-E1-06.pdf, pages 351 to 360

Pages 351 to 360 of 381, from C200HW-DRT21, CQM1-DRT21, DRT1 Series DeviceNet Slaves Operation Manual

The original document is the PDF (7.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Omron DRT1-ID16

Page 351

Appendix B

Using Another Company’s Master Unit Item Object instance 2

Section Instance type

Polled I/O

1

Production trigger Transport type

Cyclic Server

-----

Transport class

2

---

Item Object instance 2

ID content Attribute

Max. number of instances

1 State

Get (read) Yes

Set (write) No

---

2 Instance type 3 Transport class trigger

Yes Yes

No No

0100 (hexadecimal) 82 (hexadecimal)

4 Produced connection ID 5 Consumed connection ID

Yes Yes

No No

-----

6 Initial comm. characteristics 7 Produced connection size

Yes Yes

No No

01 (hexadecimal) See note.

8 Consumed connection size 9 Expected packet rate

Yes Yes

No Yes

See note. ---

12 Watchdog time-out action 13 Produced connection path length

Yes Yes

No No

0000 (hexadecimal) 0000 (hexadecimal)

14 Produced connection path 15 Consumed connection path length

Yes Yes

No No

No 0000 (hexadecimal)

16 Consumed connection path 17 Production inhibit time

Yes Yes

No No

No 0000 (hexadecimal)

Item Object instance 2

Information

DeviceNet service Service

Value

Parameter option

05Reset 0EGet_Attribute_Single

No No

10Set_Attribute_Single

No

Note The number of bytes in the specified Read Area (Input Area) and Write Area (Output Area) is as follows: Produced connection size: Read Area bytes (default: 0200 (hexadecimal)) Consumed connection size: Write Area bytes (default: 0200 (hexadecimal)) Item Object instance 3

336

Section

Information

Max. number of instances

Instance type Production trigger

Bit strobed I/O Cyclic

1 ---

Transport type Transport class

Server 2

-----

Page 352

Appendix B

Using Another Company’s Master Unit Item Object instance 3

ID content Attribute

1 State

Get (read) Yes

Set (write) No

---

2 Instance type 3 Transport class trigger

Yes Yes

No No

0100 (hexadecimal) 82 (hexadecimal)

4 Produced connection ID 5 Consumed connection ID

Yes Yes

No No

-----

6 Initial comm. characteristics 7 Produced connection size

Yes Yes

No No

01 (hexadecimal) See note.

8 Consumed connection size 9 Expected packet rate

Yes Yes

No Yes

0800 (hexadecimal) ---

12 Watchdog time-out action 13 Produced connection path length

Yes Yes

No No

0000 (hexadecimal) 0000 (hexadecimal)

14 Produced connection path 15 Consumed connection path length

Yes Yes

No No

No 0000 (hexadecimal)

16 Consumed connection path 17 Production inhibit time

Yes Yes

No No

No 0000 (hexadecimal)

Item Object instance 3

DeviceNet service Service

Value

Parameter option

05

Reset

No

0E

Get_Attribute_Single

No

10

Set_Attribute_Single

No

Note The number of bytes in the specified Read Area (Input Area) is as follows: Produced connection size: Read Area bytes (default: 0200 (hexadecimal))

PLC Object (0x2F) Object class

Attribute

Not supported

Service

Not supported

Item Object instance 1 (CIO Area 1: IR 000 to IR 235) See note.

Service

Object instance 2 (CIO Area 2: IR 300 to IR 511) See note.

Service

Object instance 3 (DM Area: DM 0 to DM 6143) See note.

Service

Object instance 4 (LR Area: LR 00 to LR 63) See note.

Service

Object instance 5 (HR Area: HR 00 to HR 99) See note.

Service

DeviceNet service 1C Block String Read

Parameter option Logical Area Address Length

1D Block String N Read 1E Block String Write

Logical Area Address Length Logical Area Address

1F Block String N Write 1C Block String Read

Logical Area Address Logical Area Address Length

1D Block String N Read 1E Block String Write

Logical Area Address Length Logical Area Address

1F Block String N Write 1C Block String Read

Logical Area Address Logical Area Address Length

1D Block String N Read 1E Block String Write

Logical Area Address Length Logical Area Address

1F Block String N Write 1C Block String Read

Logical Area Address Logical Area Address Length

1D Block String N Read 1E Block String Write

Logical Area Address Length Logical Area Address

1F Block String N Write 1C Block String Read

Logical Area Address Logical Area Address Length

1D Block String N Read 1E Block String Write

Logical Area Address Length Logical Area Address

1F Block String N Write

Logical Area Address

337

Page 353

Appendix B

Using Another Company’s Master Unit Item Object instance 6 (AR Area: AR 00 to AR 27) See note.

Service

Object instance 7 (TIM/CNT Area: TIM/CNT 000 to TIM/CNT 511) See note.

Service

Object instance 8 Service (EM Area: Depends on the model) See note.

DeviceNet service 1C Block String Read

Parameter option Logical Area Address Length

1D Block String N Read 1E Block String Write

Logical Area Address Length Logical Area Address

1F Block String N Write 1C Block String Read

Logical Area Address Logical Area Address Length

1D Block String N Read 1E Block String Write

Logical Area Address Length Logical Area Address

1F Block String N Write 1C Block String Read

Logical Area Address Logical Area Address Length

1D Block String N Read 1E Block String Write

Logical Area Address Length Logical Area Address

1F Block String N Write

Logical Area Address

Note The data areas shown in the table are for C200HX/HG/HE (-ZE) PLCs. Refer to the following table for the equivalent data areas in CS1H/G PLCs. C200HX/HG/HE (-ZE) CIO Area 1 (IR 000 to IR 235)

CS1H/G CIO Area 1 (CIO 000 to CIO 235)

CIO Area 2 (IR 300 to IR 511) DM Area (DM 0000 to DM 6143)

CIO Area 2 (CIO 300 to CIO 511) Data Memory Area (D0000 to D6143)

LR Area (LR 00 to LR 63) HR Area (HR 00 to HR 99)

No equivalent Holding Area (H000 to H099)

AR Area (AR 00 to AR 27) TC Area (TC 00 to TC 511)

Holding Area (H100 to H127) (H101 is not allowed.) Timer PV Area (T000 to T511)

EM Area (Depends on the model being used.)

E Area (Depends on the model being used.)

Refresh Object (0x92) Object class

Attribute Service Item

Object instance 1 (current value)

ID and contents Attribute

Item Object instance 1 (current value)

338

64: Output refresh bytes 65: Output refresh area type

Get (read) Yes Yes

Set (write) No No

-----

Yes

No

---

67: Input refresh bytes 68: Input refresh area type

Yes Yes

No No

-----

69: Input refresh address

Yes

No

--Parameter option

0EGet_Attribute_Single 01Set_Attribute_Single ID content

Attribute

Value

66: Output refresh address

DeviceNet service Service

Item Object instance 2 (set value)

Not supported Not supported

No No

64: Output refresh bytes

Get (read) Yes

Set (write) Yes

Value ---

65: Output refresh area type 66: Output refresh address

Yes Yes

Yes Yes

-----

67: Input refresh bytes 68: Input refresh area type

Yes Yes

Yes Yes

-----

69: Input refresh address

Yes

Yes

---

Page 354

Appendix B

Using Another Company’s Master Unit Item Object instance 2 (set value)

DeviceNet service Service

Parameter option

0E Get_Attribute_Single

No

10 Set_Attribute_Single

No

01 Get_Attribute_All

No

02 Set_Attribute_All

No

Note The refresh areas are divided as follows: C200HX/HG/HE (-ZE)

CS1H/G

CIO Area 1 (IR 000 to IR 235) CIO Area 2 (IR 300 to IR 511)

CIO Area 1 (CIO 000 to CIO 235) CIO Area 2 (CIO 300 to CIO 511)

DM Area (DM 0000 to DM 6143) LR Area (LR 00 to LR 63)

Data Memory Area (D0000 to D6143) No equivalent

HR Area (HR 00 to HR 99) AR Area (AR 00 to AR 27)

Holding Area (H000 to H099) Holding Area (H100 to H127) (H101 is not allowed.)

TC Area (TC 00 to TC 511) Timer PV Area (T000 to T511) EM or E Area (Only valid with PLC’s equipped with Extended Data Memory. Bank 0 only.)

Note Device Profile for the RS-232C Unit General data

Compatible DeviceNet Specifications

Volume I - Release 2.0 Volume II - Release 2.0

Header name Device type name

OMRON Corporation Slaves: Generic W347

Manufacturer catalog number Manufacturer revision Physical conform- Network current consumption ance data Connector type

Communications data

Header ID = 47 Device type number = 0

1.0 24 V DC at 50 mA max.

Physical insulation

Open plug Yes

Supported indicators MAC ID setting

Module, Network DIP switch

Default MAC ID Baud rate setting

0 DIP switch

Supported baud rates Predefined Master/Slave connection set

125 kbps, 250 kbps, and 500 kbps Group 2 only server

Dynamic connection support (UCMM) Explicit message fragmentation support

Yes Yes

Object Mounting Identity Object (0x01) Object class

Attribute

Not supported

Service

Not supported

339

Page 355

Appendix B

Using Another Company’s Master Unit Item Object instance Attribute

ID content 1 Vendor

Get (read) Set (write) Yes No 47

2 Product type 3 Product code

Yes Yes

No No

0 308

4 Revision 5 Status (bits supported)

Yes Yes

No No

1.4 ---

6 Serial number 7 Product name

Yes Yes

No No

Unique for each Unit DRT1-232C

8 State

No

No

---

Item Object instance

DeviceNet service Service

05Reset 0EGet_Attribute_Single

Value

Parameter option No No

Message Router Object (0x02) Object class

Attribute Service

Not supported Not supported

Object instance

Attribute Service

Not supported Not supported

Header specification addition

No

DeviceNet Object (0x03) Item Object class Object class

ID content

Set (write) No

Value

1 Revision

Service

Not supported ID content

Get (read)

Set (write)

Attribute

1 MAC ID 2 Baud rate

Yes Yes

No No

-----

3 BOI 4 Bus Off counter

Yes Yes

No No

00 (hexadecimal) ---

5 Allocation information 6 MAC ID switch changed

Yes No

No No

-----

7 Baud rate switch changed 8 MAC ID switch value

No No

No No

-----

9 Baud rate switch value

No

No

---

Item Object instance

Get (read) Yes

Attribute

Item Object instance Service

02 (hexadecimal)

DeviceNet service 0EGet_Attribute_Single

No

4BAllocate_Master/Slave_Connection_Set 4CRelease_Master/Slave_Connection_Set

No No

Value

Parameter option

Assembly Object (0x04) Object class

Attribute

Not supported

Service

Not supported

Item Object instance Attribute Item Object instance

340

ID content 3 Data

Get (read) Set (write) Yes No ---

DeviceNet service Service

0EGet_Attribute_Single 10Set_Attribute_Single

Value

Parameter option No No

Page 356

Appendix B

Using Another Company’s Master Unit Connection Object (0x05) Object class

Attribute Service

Not supported Not supported

Max. number of active connections

1

Item

Section

Object instance 1

Max. number of instances

Instance type Production trigger

Explicit Message Cyclic

1 ---

Transport type Transport class

Server 3

-----

Item Object instance 1

Information

ID content Attribute

1 State

Get (read) Yes

Set (write) No

---

2 Instance type 3 Transport class trigger

Yes Yes

No No

0000 (hexadecimal) 83 (hexadecimal)

4 Produced connection ID 5 Consumed connection ID

Yes Yes

No No

-----

6 Initial comm. characteristics 7 Produced connection size

Yes Yes

No No

21 (hexadecimal) FFFF (hexadecimal)

8 Consumed connection size 9 Expected packet rate

Yes Yes

No Yes

FFFF (hexadecimal) ---

12 Watchdog time-out action 13 Produced connection path length

Yes Yes

Yes No

01 (hexadecimal) 00 (hexadecimal)

14 Produced connection path 15 Consumed connection path length

Yes Yes

No No

--00 (hexadecimal)

16 Consumed connection path 17 Production inhibit time

Yes Yes

No No

--00 (hexadecimal)

Item

DeviceNet service 0EGet_Attribute_Single 10Set_Attribute_Single

Value

Parameter option

Object instance 1

Service

No No

Item Object instance 2

Section Instance type

Polled I/O

1

Production trigger Transport type

Cyclic Server

-----

Transport class

2

---

Information

Max. number of instances

341

Page 357

Appendix B

Using Another Company’s Master Unit Item Object instance 2

ID content Attribute

1 State

Get (read) Yes

Set (write) No

---

2 Instance type 3 Transport class trigger

Yes Yes

No No

01 (hexadecimal) 82 (hexadecimal)

4 Produced connection ID 5 Consumed connection ID

Yes Yes

No No

-----

6 Initial comm. characteristics 7 Produced connection size

Yes Yes

No No

01 (hexadecimal) 0200 (hexadecimal)

8 Consumed connection size 9 Expected packet rate

Yes Yes

No Yes

0000 (hexadecimal) ---

12 Watchdog time-out action 13 Produced connection path length

Yes Yes

No No

00 (hexadecimal) 02 (hexadecimal)

14 Produced connection path 15 Consumed connection path length

Yes Yes

No No

--00 (hexadecimal)

16 Consumed connection path 17 Production inhibit time

Yes Yes

No No

--00 (hexadecimal)

Item Object instance 2

DeviceNet service Service

Item

Item Object instance 3

342

No No Information

Max. number of instances

Instance type Production trigger

Bit strobed I/O Cyclic

1 ---

Transport type Transport class

Server 2

-----

Item Object instance 3

Parameter option

0EGet_Attribute_Single 10Set_Attribute_Single Section

Object instance 3

ID content Attribute

Service

Value

Set (write)

Get (read)

Value

1 State 2 Instance type

Yes Yes

No No

--01 (hexadecimal)

3 Transport class trigger 4 Produced connection ID

Yes Yes

No No

82 (hexadecimal) ---

5 Consumed connection ID 6 Initial comm. characteristics

Yes Yes

No No

--02 (hexadecimal)

7 Produced connection size 8 Consumed connection size

Yes Yes

No No

0200 (hexadecimal) 0800 (hexadecimal)

9 Expected packet rate 12 Watchdog time-out action

Yes Yes

Yes No

--00 (hexadecimal)

13 Produced connection path length 14 Produced connection path

Yes Yes

No No

06 (hexadecimal) 20_04_24_01_30_03

15 Consumed connection path length 16 Consumed connection path

Yes Yes

No No

00 (hexadecimal) ---

17 Production inhibit time

Yes

No

00 (hexadecimal)

DeviceNet service 0EGet_Attribute_Single

No

Parameter option

10Set_Attribute_Single

No

Page 358

Appendix C Connectable Devices and Device Current Consumptions Slave Units Basic I/O Slave Units Model DRT1-ID08

Specifications Remote I/O Terminal 8 Transistor inputs (NPN)

Manufacturer OMRON

DRT1-ID08-1

Remote I/O Terminal 8 Transistor inputs (PNP)

OMRON

DRT1-ID16

Remote I/O Terminal 16 Transistor inputs (NPN)

OMRON

DRT1-ID16-1

Remote I/O Terminal 16 Transistor inputs (PNP)

OMRON

DRT1-OD08

Remote I/O Terminal 8 Transistor outputs (NPN) Remote I/O Terminal 8 Transistor outputs (PNP) Remote I/O Terminal 16 Transistor outputs (NPN) Remote I/O Terminal 16 Transistor outputs (PNP)

OMRON

DRT1-OD08-1 DRT1-OD16 DRT1-OD16-1

OMRON OMRON OMRON

DRT1-MD16

Remote I/O Terminal OMRON 8 Transistor inputs, 8 transistor outputs (NPN)

DRT1-ID16T

Remote I/O Terminal 16 Transistor inputs (NPN) (3-tier I/O Terminal Block)

OMRON

DRT1-ID16T-1

Remote I/O Terminal 16 Transistor inputs (PNP) (3-tier I/O Terminal Block) Remote I/O Terminal 16 Transistor outputs (NPN) (3-tier I/O Terminal Block) Remote I/O Terminal 16 Transistor outputs (PNP) (3-tier I/O Terminal Block) Remote I/O Terminal 8 Transistor inputs, 8 transistor outputs (NPN) (3-tier I/O Terminal Block)

OMRON

DRT1-OD16T

DRT1-OD16T-1

DRT1-MD16T

OMRON

OMRON

OMRON

DRT1-MD16T-1

Remote I/O Terminal OMRON 8 Transistor inputs, 8 transistor outputs (PNP) (3-tier I/O Terminal Block)

DRT1-ID16TA

Remote I/O Terminal OMRON 16 Transistor inputs (NPN) (3-tier I/O Terminal Block, internal power supply not required) Remote I/O Terminal OMRON 16 Transistor inputs (PNP) (3-tier I/O Terminal Block, internal power supply not required)

DRT1-ID16TA-1

343

Page 359

Connectable Devices and Device Current Consumptions Model DRT1-OD16TA

Specifications Manufacturer Remote I/O Terminal OMRON 16 Transistor outputs (NPN) (3-tier I/O Terminal Block, internal power supply not required)

DRT1-OD16TA-1

Remote I/O Terminal OMRON 16 Transistor outputs (PNP) (3-tier I/O Terminal Block, internal power supply not required) Remote I/O Terminal OMRON 8 Transistor inputs, 8 transistor outputs (NPN) (3-tier I/O Terminal Block, internal power supply not required)

DRT1-MD16TA

DRT1-MD16TA-1

DRT1-ID32ML

Remote I/O Terminal OMRON 8 Transistor inputs, 8 transistor outputs (PNP) (3-tier I/O Terminal Block, internal power supply not required) Remote I/O Terminal OMRON 32 Transistor inputs (NPN) with Connectors

DRT1-ID32ML-1

Remote I/O Terminal 32 Transistor inputs (PNP) with Connectors

OMRON

DRT1-OD32ML

Remote I/O Terminal 32 Transistor outputs (NPN) with Connectors

OMRON

DRT1-OD32ML-1

Remote I/O Terminal 32 Transistor outputs (PNP) with Connectors Remote I/O Terminal 16 Transistor inputs, 16 transistor outputs (NPN) with Connectors

OMRON

DRT1-MD32ML-1

Remote I/O Terminal 16 Transistor inputs, 16 transistor outputs (PNP) with Connectors

OMRON

DRT1-ID16X

Remote Adapter 16 Transistor inputs (NPN)

OMRON

DRT1-ID16X-1

Remote Adapter 16 Transistor inputs (PNP)

OMRON

DRT1-OD16X

Remote Adapter 16 Transistor outputs (NPN) Remote Adapter 16 Transistor outputs (PNP) Sensor Terminal 8 sensor inputs (NPN) 2 inputs per sensor Sensor Terminal 8 sensor inputs (NPN) 1 input and 1 output per sensor

OMRON

DRT1-AD04

Analog Input Terminal 4 analog inputs (using 4 words) or 2 analog inputs (using 2 words) (Switchable)

OMRON

DRT1-AD04H

Analog Input Terminal 4 analog inputs (using 4 words)

OMRON

DRT1-DA02

Analog Output Terminal 2 analog outputs (using 2 words) Temperature Input Terminal Thermocouple thermometer input 4 temperature data inputs (using 4 words)

OMRON

DRT1-MD32ML

DRT1-OD16X-1 DRT1-HD16S

DRT1-ND16S

DRT1-TS04T

344

Appendix C

OMRON

OMRON OMRON

OMRON

OMRON

Page 360

Appendix C

Connectable Devices and Device Current Consumptions Model DRT1-TS04P

CQM1-DRT21

Specifications Temperature Input Terminal Temperature-resistance thermometer input 4 temperature data inputs (using 4 words) I/O Link Unit suitable for CQM1-series PLC. 16 inputs and 16 outputs

Manufacturer OMRON

OMRON

Environment-resistive Slaves Model

Specifications

DRT1-ID08C

Environment-resistive Terminal 8 Transistor inputs (NPN) Conforms to IEC IP66

OMRON

DRT1-HD16C

Environment-resistive Terminal 16 Transistor inputs (NPN) Conforms to IEC IP66

OMRON

DRT1-HD16C-1

Environment-resistive Terminal 16 Transistor inputs (PNP) Conforms to IEC IP66 Environment-resistive Terminal 8 Transistor outputs (NPN) Conforms to IEC IP66 Environment-resistive Terminal 16 Transistor outputs (NPN) Conforms to IEC IP66 Environment-resistive Terminal 16 Transistor outputs (PNP) Conforms to IEC IP66

OMRON

DRT1-OD08C

DRT1-WD16C

DRT1-WD16C-1

Manufacturer

OMRON

OMRON

OMRON

DRT1-MD16C

Environment-resistive Terminal OMRON 8 Transistor inputs, 8 transistor outputs (NPN) Conforms to IEC IP66

DRT1-MD16C-1

Environment-resistive Terminal OMRON 8 Transistor inputs, 8 transistor outputs (NPN) Conforms to IEC IP66 Waterproof Terminal OMRON 4 Transistor inputs (NPN) Conforms to IEC IP67 Waterproof Terminal OMRON 4 Transistor inputs (PNP) Conforms to IEC IP67 Waterproof Terminal OMRON 8 Transistor inputs (NPN) Conforms to IEC IP67

DRT1-ID04CL

DRT1-ID04CL-1

DRT1-ID08CL

DRT1-ID08CL-1

Waterproof Terminal 8 Transistor inputs (PNP) Conforms to IEC IP67

OMRON

DRT1-OD04CL

Waterproof Terminal 4 Transistor outputs (NPN) Conforms to IEC IP67

OMRON

DRT1-OD04CL-1

Waterproof Terminal 4 Transistor outputs (PNP) Conforms to IEC IP67 Waterproof Terminal 8 Transistor outputs (NPN) Conforms to IEC IP67 Waterproof Terminal 8 Transistor outputs (PNP) Conforms to IEC IP67 B7AC Interface Unit

OMRON

DRT1-OD08CL

DRT1-OD08CL-1

DRT1-B7AC

OMRON

OMRON

OMRON