For the Omron DRT1-ID16
Page 341
Appendix B
Using Another Company’s Master Unit Physical conform- Network current consumption ance data
40 mA max. (24 V DC) for the following Units: CQM1-DRT21, DRT1-HD16S, DRT1-ND16S, and DRT1-OD08CL 30 mA max. (24 V DC) for the following Units: DRT1-ID08(-1), DRT1-ID16(-1), DRT1-OD08(-1), DRT1-OD16(-1), DRT1-ID16T(-1), DRT1-OD16T(-1), DRT1-MD16T(-1), DRT1-WD16C(-1), DRT1-MD16C(-1), DRT1-ID16X(-1), DRT1-OD16X(-1), DRT1-AD04, DRT1-AD04H, DRT1-DA02, DRT1-ID08CL(-1), DRT1-ID08C, DRT1-HD16C(-1), DRT1-TS04T, and DRT1-TS04P 25 mA max. (24 V DC) for the following Units: DRT1-MD16 and DRT1-ID04CL(-1), 50 mA max. (24 V DC) for the following Units: DRT1-ID16TA(-1), DRT1-OD16TA(-1), DRT1-MD16TA(-1), and DRT1-ID32ML(-1),
Communications data
Connector type
90 mA max. (24 V DC) for the following Unit: DRT1-OD32ML(-1) 70 mA max. (24 V DC) for the following Units: DRT1-MD32ML(-1) and DRT1-B7AC 35 mA max. (24 V DC) for the following Unit: DRT1-OD04CL(-1) Open plug
Physical insulation Supported indicators
Yes Module, Network
MAC ID setting Default MAC ID
DIP switch 0
Baud rate setting Supported baud rates
DIP switch 125 kbps, 250 kbps, and 500 kbps
Predefined Master/Slave connection set Dynamic connection support (UCMM)
Group 2 only server No
Explicit message fragmentation support
Yes
Note For Analog Input Terminals, Analog Output Terminals, and Temperature Input Terminals, Volume I is 1.2 and Volume II is 1.1.
Object Mounting Identity Object (0x01) Object class
Attribute Service Item
Object instance
326
Not supported Not supported ID content
Attribute
Get (read)
Set (write)
Value
1 Vendor 2 Product type
Yes Yes
No No
47 0
3 Product code 4 Revision
Yes Yes
No No
See note 2. 1.3 (See note 1.)
5 Status (bits supported) 6 Serial number
Yes Yes
No No
Bit 0 only Unique for each Unit
7 Product name 8 State
Yes No
No No
Same as the model name. ---
Page 342
Appendix B
Using Another Company’s Master Unit Item Object instance Service
DeviceNet service 05Reset
No
Parameter option
0EGet_Attribute_Single
No
Note 1. For Analog Input Terminals, Analog Output Terminals, and Temperature Input Terminals, Revision is 1.2. 2. The product code depends on the Slave. Refer to the following table. Model
Product code
DRT1-ID08 DRT1-ID08-1
100 106
DRT1-ID16 DRT1-ID16-1
102 108
DRT1-OD08 DRT1-OD08-1
101 107
DRT1-OD16 DRT1-OD16-1
103 109
DRT1-MD16 DRT1-ID16T
168 122
DRT1-ID16T-1 DRT1-OD16T
125 124
DRT1-OD16T-1 DRT1-MD16T
127 123
DRT1-MD16T-1 DRT1-ID16TA
126 142
DRT1-ID16TA-1 DRT1-OD16TA
146 144
DRT1-OD16TA-1
148
DRT1-MD16TA DRT1-MD16TA-1
143 144
DRT1-ID32ML DRT1-ID32ML-1
128 131
DRT1-OD32ML DRT1-OD32ML-1
129 132
DRT1-MD32ML DRT1-MD32ML-1
130 133
DRT1-ID16X DRT1-ID16X-1
104 110
DRT1-OD16X DRT1-OD16X-1
105 111
DRT1-HD16S DRT1-ND16S
2 9
DRT1-TS04T DRT1-TS04P
302 303
DRT1-AD04 DRT1-AD04H
300 304
DRT1-DA02 CQM1-DRT21
301 50
DRT1-ID04CL DRT1-ID04CL-1
134 138
DRT1-ID08CL
136
327
Page 343
Appendix B
Using Another Company’s Master Unit Model DRT1-ID08CL-1
Product code 140
DRT1-ID08C DRT1-HD16C
112 120
DRT1-HD16C-1 DRT1-OD04CL
115 135
DRT1-OD04CL-1 DRT1-OD08CL
139 137
DRT1-OD08CL-1 DRT1-OD08C
141 113
DRT1-WD16C DRT1-WD16C-1
121 116
DRT1-MD16C DRT1-MD16C-1
114 117
DRT1-B7AC
430
Message Router Object (0x02) Object class
Attribute Service
Not supported Not supported
Object instance
Attribute Service
Not supported Not supported
Header specification addition
No
DeviceNet Object (0x03) Object class
Attribute
Not supported
Service
Not supported
Item Object instance Attribute
Item Object instance Service
ID content 1 MAC ID
Get (read) Set (write) Yes No ---
2 Baud rate 3 BOI
Yes Yes
No No
--00 (hexadecimal)
4 Bus Off counter 5 Allocation information
No Yes
No No
-----
6 MAC ID switch changed 7 Baud rate switch changed
No No
No No
-----
8 MAC ID switch value 9 Baud rate switch value
No No
No No
-----
DeviceNet service 0EGet_Attribute_Single
No
4BAllocate_Master/Slave_Connection_Set 4CRelease_Master/Slave_Connection_Set
No No
Value
Parameter option
Assembly Object (0x04) Object class
Attribute Service
Not supported Not supported Get (read)
Set (write)
Attribute
1 Number of members in list 2 Member list
No No
No No
-----
3 Data 9 Baud rate switch value
Yes No
No No
-----
Item Object instance 1 (Instance type Static I/O)
328
ID content
Value
Page 344
Appendix B
Using Another Company’s Master Unit Item Object instance 1 Service (Instance type Static I/O)
DeviceNet service 0EGet_Attribute_Single
Parameter option No
Connection Object (0x05) Object class
Item Object instance 1
Attribute Service
Not supported Not supported
Max. number of active connections
1
Section Instance type
Information Explicit Message
1
Production trigger Transport type
Cyclic Server
-----
Transport class
3
---
Item Object instance 1
ID content Attribute
Item Object instance 2
Get (read)
Set (write)
Yes Yes
No No
--00 (hexadecimal)
3 Transport class trigger 4 Produced connection ID
Yes Yes
No No
83 (hexadecimal) ---
5 Consumed connection ID 6 Initial comm. characteristics
Yes Yes
No No
--21 (hexadecimal)
7 Produced connection size 8 Consumed connection size
Yes Yes
No No
0D00 (hexadecimal) 0D00 (hexadecimal)
9 Expected packet rate 12 Watchdog time-out action
Yes Yes
Yes No
--01 (hexadecimal)
13 Produced connection path length 14 Produced connection path
Yes Yes
No No
00 (hexadecimal) ---
15 Consumed connection path length 16 Consumed connection path
Yes Yes
No No
00 (hexadecimal) ---
17 Production inhibit time
Yes
No
00 (hexadecimal)
DeviceNet service Service
Value
1 State 2 Instance type
Item Object instance 1
Max. number of instances
Parameter option
05Reset 0EGet_Attribute_Single
No No
10Set_Attribute_Single
No
Section Instance type
Polled I/O
Information 1
Max. number of instances
Production trigger Transport type
Cyclic Server
-----
Transport class
2
---
329
Page 345
Appendix B
Using Another Company’s Master Unit Item Object instance 2
Item Object instance 2
ID content Attribute
1 State
Get (read) Yes
Set (write) No
---
2 Instance type 3 Transport class trigger
Yes Yes
No No
01 (hexadecimal) 82 (hexadecimal)
4 Produced connection ID 5 Consumed connection ID
Yes Yes
No No
-----
6 Initial comm. characteristics 7 Produced connection size
Yes Yes
No No
01 (hexadecimal) See note.
8 Consumed connection size 9 Expected packet rate
Yes Yes
No Yes
See note. ---
12 Watchdog time-out action 13 Produced connection path length
Yes Yes
No No
01 (hexadecimal) See note.
14 Produced connection path 15 Consumed connection path length
Yes Yes
No No
See note. See note.
16 Consumed connection path 17 Production inhibit time
Yes Yes
No No
See note. 00 (hexadecimal)
DeviceNet service Service
Value
Parameter option
05Reset
No
0EGet_Attribute_Single 10Set_Attribute_Single
No No
Note These values depend on the type of Slave being used. Refer to the following table. Model
Produced Consumed Produced connection connection connection size size path length
Produced connection path
Consumed connection path length
Consumed connection path
DRT1-ID08
01H
00H
6
20_04_24_01_30_03
0
---
DRT1-ID08-1
01H
00H
6
20_04_24_01_30_03
0
---
DRT1-ID16
02H
00H
6
20_04_24_01_30_03
0
---
DRT1-ID16-1
02H
00H
6
20_04_24_01_30_03
0
---
DRT1-OD08
00H
01H
0
---
6
20_04_24_01_30_03
DRT1-OD08-1
00H
01H
0
---
6
20_04_24_01_30_03
DRT1-OD16
00H
02H
0
---
6
20_04_24_01_30_03
DRT1-OD16-1
00H
02H
0
---
6
20_04_24_01_30_03
DRT1-MD16
01H
01H
6
20_04_24_01_30_03
6
20_04_24_01_30_03
DRT1-ID16T
02H
00H
6
20_04_24_01_30_03
0
---
DRT1-ID16T-1
02H
00H
6
20_04_24_01_30_03
0
---
DRT1-OD16T
00H
02H
0
---
6
20_04_24_01_30_03
DRT1-OD16T-1
00H
02H
0
---
6
20_04_24_01_30_03
DRT1-MD16T
01H
01H
6
20_04_24_01_30_03
6
20_04_24_01_30_03
DRT1-MD16T-1
01H
01H
6
20_04_24_01_30_03
6
20_04_24_01_30_03
DRT1-ID16TA
02H
00H
6
20_04_24_01_30_03
0
---
DRT1-ID16TA-1
02H
00H
6
20_04_24_01_30_03
0
---
DRT1-OD16TA
00H
02H
0
---
6
20_04_24_01_30_03
DRT1-OD16TA-1
00H
02H
0
---
6
20_04_24_01_30_03
DRT1-MD16TA
01H
01H
6
20_04_24_01_30_03
6
20_04_24_01_30_03
DRT1-MD16TA-1
01H
01H
6
20_04_24_01_30_03
6
20_04_24_01_30_03
DRT1-ID32ML
04H
00H
6
20_04_24_01_30_03
0
---
DRT1-ID32ML-1
04H
00H
6
20_04_24_01_30_03
0
---
DRT1-OD32ML
00H
04H
0
---
6
20_04_24_01_30_03
DRT1-OD32ML-1
00H
04H
0
---
6
20_04_24_01_30_03
DRT1-MD32ML
02H
02H
6
20_04_24_01_30_03
6
20_04_24_01_30_03
DRT1-MD32ML-1
02H
02H
6
20_04_24_01_30_03
6
20_04_24_01_30_03
330
Page 346
Appendix B
Using Another Company’s Master Unit Model
Produced Consumed Produced connection connection connection size size path length
Produced connection path
Consumed connection path length
Consumed connection path
DRT1-ID16X
02H
00H
6
20_04_24_01_30_03
0
---
DRT1-ID16X-1
02H
00H
6
20_04_24_01_30_03
0
---
DRT1-OD16X
00H
02H
0
---
6
20_04_24_01_30_03
DRT1-OD16X-1
00H
02H
0
---
6
20_04_24_01_30_03
DRT1-HD16S
02H
00H
6
20_04_24_01_30_03
0
---
DRT1-ND16S
01H
01H
6
20_04_24_01_30_03
6
20_04_24_01_30_03
DRT1-TS04T
08H
00H
6
20_04_24_01_30_03
0
---
DRT1-TS04P
08H
00H
6
20_04_24_01_30_03
0
---
DRT1-AD04
04H or 08H
00H
6
20_04_24_01_30_03
0
---
DRT1-AD04H
08H
00H
6
20_04_24_01_30_03
0
---
DRT1-DA02
00H
04H
0
---
6
20_04_24_01_30_03
CQM1-DRT21
02H
02H
6
20_04_24_01_30_03
6
20_04_24_01_30_03
DRT1-ID04CL
01H
00H
6
20_04_24_01_30_03
0
---
DRT1-ID04CL-1
01H
00H
6
20_04_24_01_30_03
0
---
DRT1-ID08CL
01H
00H
6
20_04_24_01_30_03
0
---
DRT1-ID08CL-1
01H
00H
6
20_04_24_01_30_03
0
---
DRT1-ID08C
01H
00H
6
20_04_24_01_30_03
0
---
DRT1-HD16C
02H
00H
6
20_04_24_01_30_03
0
---
DRT1-HD16C-1
02H
00H
6
20_04_24_01_30_03
0
---
DRT1-OD04CL
00H
01H
0
---
6
20_04_24_01_30_03
DRT1-OD04CL-1
00H
01H
0
---
6
20_04_24_01_30_03
DRT1-OD08CL
00H
01H
0
---
6
20_04_24_01_30_03
DRT1-OD08CL-1
00H
01H
0
---
6
20_04_24_01_30_03
DRT1-OD08C
00H
01H
0
---
6
20_04_24_01_30_03
DRT1-WD16C
00H
01H
0
---
6
20_04_24_01_30_03
DRT1-WD16C-1
00H
01H
0
---
6
20_04_24_01_30_03
DRT1-MD16C
01H
01H
6
20_04_24_01_30_03
6
20_04_24_01_30_03
DRT1-MD16C-1
01H
01H
6
20_04_24_01_30_03
6
20_04_24_01_30_03
DRT1-B7AC
04H
00H
6
20_04_24_01_30_03
0
---
Item Object instance 3
Section
Information
Max. number of instances
Instance type Production trigger
Bit strobed I/O Cyclic
1 ---
Transport type Transport class
Server 2
-----
331
Page 347
Appendix B
Using Another Company’s Master Unit Item Object instance 3
Item Object instance 3
ID content Attribute
1 State
Get (read) Yes
Set (write) No
---
2 Instance type 3 Transport class trigger
Yes Yes
No No
01 (hexadecimal) 82 (hexadecimal)
4 Produced connection ID 5 Consumed connection ID
Yes Yes
No No
-----
6 Initial comm. characteristics 7 Produced connection size
Yes Yes
No No
01 (hexadecimal) See note.
8 Consumed connection size 9 Expected packet rate
Yes Yes
No Yes
0800H ---
12 Watchdog time-out action 13 Produced connection path length
Yes Yes
No No
01 See note.
14 Produced connection path 15 Consumed connection path length
Yes Yes
No No
See note. See note.
16 Consumed connection path
Yes
No
See note.
DeviceNet service Service
Value
Parameter option
05Reset
No
0EGet_Attribute_Single 10Set_Attribute_Single
No No
Note These values depend on the type of Slave being used. Refer to the following table. Model
Produced Produced connection connection size path length
Produced connection path
Consumed connection path length
Consumed connection path
DRT1-ID08
01H
6
20_04_24_01_30_03
0
---
DRT1-ID08-1 DRT1-ID16
01H 02H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-ID16-1 DRT1-OD08
02H 00H
6 0
20_04_24_01_30_03 ---
0 6
--20_04_24_01_30_03
DRT1-OD08-1 DRT1-OD16
00H 00H
0 0
-----
6 6
20_04_24_01_30_03 20_04_24_01_30_03
DRT1-OD16-1 DRT1-MD16
00H 01H
0 6
--20_04_24_01_30_03
6 0
20_04_24_01_30_03 ---
DRT1-ID16T DRT1-ID16T-1
02H 02H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-OD16T DRT1-OD16T-1
00H 00H
0 0
-----
6 6
20_04_24_01_30_03 20_04_24_01_30_03
DRT1-MD16T DRT1-MD16T-1
01H 01H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-ID16TA DRT1-ID16TA-1
02H 02H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-OD16TA DRT1-OD16TA-1
00H 00H
0 0
-----
6 6
20_04_24_01_30_03 20_04_24_01_30_03
DRT1-MD16TA DRT1-MD16TA-1
01H 01H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-ID32ML DRT1-ID32ML-1
04H 04H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-OD32ML DRT1-OD32ML-1
00H 00H
0 0
-----
6 6
20_04_24_01_30_03 20_04_24_01_30_03
332
Page 348
Appendix B
Using Another Company’s Master Unit Model
DRT1-MD32ML
Produced Produced Produced connection connection connection path size path length 02H 6 20_04_24_01_30_03
Consumed Consumed connection connection path path length 0 ---
DRT1-MD32ML-1 DRT1-ID16X
02H 02H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-ID16X-1 DRT1-OD16X
02H 00H
6 0
20_04_24_01_30_03 ---
0 6
--20_04_24_01_30_03
DRT1-OD16X-1 DRT1-HD16S
00H 02H
0 6
--20_04_24_01_30_03
6 0
20_04_24_01_30_03 ---
DRT1-ND16S DRT1-TS04T
01H 08H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-TS04P DRT1-AD04
08H 04H or 08H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-AD04H DRT1-DA02
08H 00H
6 0
20_04_24_01_30_03 ---
0 6
--20_04_24_01_30_03
CQM1-DRT21 DRT1-ID04CL
02H 01H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-ID04CL-1 DRT1-ID08CL
01H 01H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-ID08CL-1 DRT1-ID08C
01H 01H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-HD16C DRT1-HD16C-1
02H 02H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
DRT1-OD04CL DRT1-OD04CL-1
00H 00H
0 0
-----
6 6
20_04_24_01_30_03 20_04_24_01_30_03
DRT1-OD08CL DRT1-OD08CL-1
00H 00H
0 0
-----
6 6
20_04_24_01_30_03 20_04_24_01_30_03
DRT1-OD08C DRT1-WD16C
00H 00H
0 0
-----
6 0
20_04_24_01_30_03 ---
DRT1-WD16C-1 DRT1-MD16C
00H 01H
0 6
--20_04_24_01_30_03
0 0
-----
DRT1-MD16C-1 DRT1-B7AC
01H 04H
6 6
20_04_24_01_30_03 20_04_24_01_30_03
0 0
-----
Device Profile for the C200H I/O Link Unit General data
Compatible DeviceNet Specifications
Volume I - Release 1.3 Volume II - Release 1.3
Header name Device type name
OMRON Corporation Slaves: Communication adapter
Manufacturer catalog number Manufacturer revision
W347 1.0
Header ID = 47 Device type number = 12
333
Page 349
Appendix B
Using Another Company’s Master Unit Physical conform- Network current consumption ance data Connector type
Communications data
24 V DC at 45 mA max. Open plug
Physical insulation Supported indicators
Yes Module, Network
MAC ID setting Default MAC ID
DIP switch 0
Baud rate setting Supported baud rates
DIP switch 125 kbps, 250 kbps, and 500 kbps
Predefined Master/Slave connection set Dynamic connection support (UCMM)
Group 2 only server No
Explicit message fragmentation support
Yes
Object Mounting Identity Object (0x01) Object class
Attribute Service
Not supported Not supported Get (read)
Set (write)
Attribute
1 Vendor 2 Product type
Yes Yes
No No
47 12
3 Product code 4 Revision
Yes Yes
No No
51 1.3
5 Status (bits supported) 6 Serial number
Yes Yes
No No
Bit 0 only Unique for each Unit
7 Product name 8 State
Yes No
No No
C200HW-DRT21 ---
Item Object instance
ID content
Item Object instance
DeviceNet service Service
05Reset 0EGet_Attribute_Single
Message Router Object (0x02) Object class
Attribute
Not supported
Object instance
Service Attribute
Not supported Not supported
Service Header specification addition
Not supported No
DeviceNet Object (0x03) Object class
334
Attribute
Not supported
Service
Not supported
Value
Parameter option No No
Page 350
Appendix B
Using Another Company’s Master Unit Item Object instance Attribute
Item Object instance Service
ID content 1 MAC ID
Get (read) Set (write) Yes No ---
2 Baud rate 3 BOI
Yes Yes
No No
--00 (hexadecimal)
4 Bus Off counter 5 Allocation information
Yes Yes
No No
-----
6 MAC ID switch changed 7 Baud rate switch changed
No No
No No
-----
8 MAC ID switch value 9 Baud rate switch value
No No
No No
-----
DeviceNet service 0EGet_Attribute_Single
No
4BAllocate_Master/Slave_Connection_Set 4CRelease_Master/Slave_Connection_Set
No No
Value
Parameter option
Connection Object (0x05) Object class
Attribute
Not supported
Service Max. number of active connections
Not supported 1
Item
Section
Object instance 1
Item Object instance 1
Max. number of instances
Explicit Message Cyclic
1 ---
Transport type Transport class
Server 3
-----
Item Object instance 1
Information
Instance type Production trigger
ID content Attribute
Set (write)
Get (read)
1 State 2 Instance type
Yes Yes
No No
--0000 (hexadecimal)
3 Transport class trigger 4 Produced connection ID
Yes Yes
No No
83 (hexadecimal) ---
5 Consumed connection ID 6 Initial comm. characteristics
Yes Yes
No No
--21 (hexadecimal)
7 Produced connection size 8 Consumed connection size
Yes Yes
No No
FE00 (hexadecimal) FE00 (hexadecimal)
9 Expected packet rate 12 Watchdog time-out action
Yes Yes
Yes No
--0100 (hexadecimal)
13 Produced connection path length 14 Produced connection path
Yes Yes
No No
0000 (hexadecimal) ---
15 Consumed connection path length 16 Consumed connection path
Yes Yes
No No
0000 (hexadecimal) ---
17 Production inhibit time
Yes
No
0000 (hexadecimal)
DeviceNet service Service
Value
Parameter option
05Reset
No
0EGet_Attribute_Single 10Set_Attribute_Single
No No