Page 1

E5CK Digital Controller User's Manual Cat. No. H078-E1-03D an 6) (B)

E5CK Digital Controller

User's Manual

Cat. No. H078-E1-03D

Page 2

Preface Thank you for your purchase of your E5CK compact, intelligent digital controller. The E5CK allows the user to carry out the following: • Select from many types of temperature and analog input (multiple input) • Select output functions such as control output or alarm (output assignment) • Use two setpoints (multi-SP function) • Monitor the control loop by LBA (Loop Break Alarm) • Use the communications function • Calibrate input or transfer output • It also features a watertight construction (NEMA4: equivalent to IP66) This User’s Manual describes how to use the E5CK compact, high-function digital controller. Before using your E5CK, thoroughly read and understand this manual in order to ensure correct use.

About this manual E OMRON, 1995 (1) All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, recording, or otherwise, without the prior written permission of OMRON. (2) No patent liability is assumed with respect to the use of the information contained herein. (3) Moreover, because OMRON is constantly striving to improve its high-quality products, the information in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.

I

Page 3

Conventions Used in This Manual J How to Read Display Symbols The following tables show the correspondence between the symbols displayed on the displays and alphabet characters.

A B C D E F G H I J K L M

N O P Q R S T U VW X Y Z J “Reference” mark This mark indicates that extra, useful information follows, such as supplementary explanations and how to apply functions.

J Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to the product.

DANGER

Indicates information that, if not heeded, is likely to result in loss of life or serious injury.

WARNING

Indicates information that, if not heeded, could possibly result in loss of life or serious injury.

Caution

Indicates information that, if not heeded, could result in relatively serious or minor injury, damage to the product, or faulty operation.

J OMRON Product References All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense. The abbreviation “PC” means Programmable Controller and is not used as an abbreviation for anything else. II

Page 4

J How this Manual is Organized Purpose

Title

Description

Learning about the general features of the E5CK

Chapter 1 Introduction

This chapter describes the features of the E5CK, names of parts, and typical functions.

Setting up the E5CK

Chapter 2 Preparations

This chapter describes the operations that you must carry out (e.g. installation, wiring and switch settings) before you can use the E5CK.

Basic E5CK operations

Chapter 3 Basic Operation Chapter 5 Parameters

These chapters describe how to use the front panel keys and how to view the display when setting the parameters of the major functions for the E5CK.

Applied E5CK operations

Chapter 4 Applied Operation These chapters describe the Chapter 5 Parameters important functions of the E5CK and how to use the parameters for making full use of the E5CK.

Communications with a host computer

Chapter 6 Using the Commu- This chapter mainly describes nications Function the communications commands, and gives program examples.

Calibration

Chapter 4 Applied Operation This chapter describes how the / 4.5 Calibration user should calibrate the E5CK.

Troubleshooting

Chapter 7 Troubleshooting

This chapter describes what to do if any problems occur.

III

Page 5

Pay Attention to the Following when Installing this Controller F If you remove the controller from its case, never touch nor apply shock to the electronic parts inside. F Do not cover the top and bottom of the controller. (Ensure sufficient space around the controller to allow heat to escape.) F Use a voltage (AC100-240V or AC/DC24V at 50 to 60 Hz). At power ON, the prescribed voltage level must be attained within two seconds. F When wiring input or output lines to your controller, keep the following points in mind to reduce the influence from inductive noise: • Allow adequate space between the high voltage/current power lines and the input/output lines. • Avoid parallel or common wiring with high voltage sources and power lines carrying large currents. • Using separating pipes, duct, and shielded line is also useful in protecting the controller, and its lines form inductive noise. F Allow as much space as possible between the controller and devices that generate a powerful, high frequency (high-frequency welders, high-frequency sewing machines, and so forth) or surge. These devices may cause malfunctions. F If there is a large power-generating peripheral device and any of its lines, attach a surge suppressor or noise filter to the device to stop the noise affecting the controller system. In particular, motors, transformers, solenoids and magnetic coils have an inductance component, and therefore can generate very strong noises. F When mounting a noise filter, be sure to first check the filter’s voltage and current capacity, then mount the filter as close as possible to the controller. F Do not use the controller in places where icing, condensation, dust, corrosive gas (especially sulfurized gas or ammonia gas), shock, vibration, splashing liquid, or oil atmosphere occur. Also, avoid places where the controller can be subjected to intense heat radiation (like from a furnace) or sudden temperature changes. F Ambient temperature must be kept between -10_C to 55_C. Ambient humidity must be kept between 35%RH to 85%RH (with no icing or condensation). If the controller is installed inside a control board, the ambient temperature must be kept under 55_C, including the temperature around the controller. If the controller is subjected to heat radiation, use a fan to cool the surface of the controller to under 55_C. F Store the controller at an ambient temperature between -25_C to 65_C. The ambient humidity must be between 35%RH to 85%RH (with no icing or condensation). F Never place heavy objects on, or apply pressure to the controller that may cause it to deform and deterioration during use or storage. F Avoid using the controller in places near a radio, television set, or wireless installation. These devices can cause radio disturbances which adversely affect the performance of the controller.

IV

Page 6

Table of Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I Conventions Used in This Manual . . . . . . . . . . . . . . . II Pay Attention to the Following when Installing this Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IV

CHAPTER 1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . .

1--1

This chapter introduces the E5CK. First-time users should read this chapter without fail. For details on how to use the controller and parameter settings, see Chapters 2 onwards.

1.1 1.2 1.3 1.4 1.5

Names of parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input and Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parameters and Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About the Communications Function . . . . . . . . . . . . . . . . . . . . . . . About Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1--2 1--4 1--6 1--9 1--10

CHAPTER 2 PREPARATIONS . . . . . . . . . . . . . . . . . . . . . . . . . .

2--1

This chapter describes the operations you should carry out before turning the E5CK ON.

2.1 Setting up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 Wiring Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2--2 2--4 2--6

CHAPTER 3 BASIC OPERATION . . . . . . . . . . . . . . . . . . . . . . . .

3--1

This chapter describes an actual example for understanding the basic operation of the E5CK.

3.1 3.2 3.3 3.4 3.5 3.6 3.7

Control Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting Input Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting Output Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting Alarm Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Protect Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Starting and Stopping Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . Adjusting Control Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3--2 3--3 3--5 3--7 3--10 3--11 3--12

CHAPTER 4 APPLIED OPERATION . . . . . . . . . . . . . . . . . . . . .

4--1

This chapter describes each of the parameters required for making full use of the features of the E5CK. Read this chapter while referring to the parameter descriptions in chapter 5.

4.1 4.2 4.3 4.4 4.5

Selecting the Control Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Condition Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . How to Use Option Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4--2 4--4 4--7 4--9 4--11

Page 7

CHAPTER 5 PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5--1

This chapter describes the parameters of the E5CK. Use this chapter as a reference guide.

Conventions Used in this Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Protect Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manual Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level 0 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level 1 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level 2 Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Expansion Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Option Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calibration Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5--2 5--3 5--5 5--6 5--9 5--15 5--21 5--27 5--32 5--36

CHAPTER 6 USING THE COMMUNICATIONS FUNCTION .

6--1

This chapter mainly describes communications with a host computer and communications commands.

6.1 6.2 6.3 6.4 6.5 6.6

Outline of the Communications Function . . . . . . . . . . . . . . . . . . . . Preparing for Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Command Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commands and Responses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How to Read Communications Error Information . . . . . . . . . . . . . Program Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6--2 6--3 6--5 6--6 6--10 6--12

CHAPTER 7 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . .

7--1

This chapter describes how to find out and remedy the cause if the E5CK does not function properly.

7.1 7.2 7.3 7.4

Initial Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How to Use the Error Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How to Use Error Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Checking Operation Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . .

7--2 7--3 7--5 7--6

APPENDIX SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . CONTROL BLOCK DIAGRAM . . . . . . . . . . . . . . SETTING LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . PARAMETER OPERATIONS LIST . . . . . . . . . . FUZZY SELF--TUNING . . . . . . . . . . . . . . . . . . . . MODEL LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X FORMAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ASCII CODE LIST . . . . . . . . . . . . . . . . . . . . . . . .

INDEX

REVISION HISTORY

A--2 A--5 A--6 A--8 A--10 A--13 A--14 A--17

Page 8

CHAPTER 1 INTRODUCTION

1

CHAPTER 1 INTRODUCTION This chapter introduces the E5CK. First-time users should read this chapter without fail. For details on how to use the controller and parameter settings, see Chapters 2 onwards.

1.1 Names of parts . . . . . . . . . . . . . . . . . . . . . . . .

1---2

Main parts . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1---2

Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . .

1---2

About the displays . . . . . . . . . . . . . . . . . . . . .

1---3

How to use keys . . . . . . . . . . . . . . . . . . . . . . .

1---3

1.2 Input and Output . . . . . . . . . . . . . . . . . . . . . .

1---4

Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1---4

Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1---5

1.3 Parameters and Menus . . . . . . . . . . . . . . . . .

1---6

Parameter types . . . . . . . . . . . . . . . . . . . . . . .

1---6

Selecting modes . . . . . . . . . . . . . . . . . . . . . . . .

1---7

Selecting parameters . . . . . . . . . . . . . . . . . . .

1---8

Fixing settings . . . . . . . . . . . . . . . . . . . . . . . . .

1---8

1.4 About the Communications Function . . . .

1---9

1.5 About Calibration . . . . . . . . . . . . . . . . . . . . . . 1---10

1--1

Page 9

E5CK

CHAPTER 1 INTRODUCTION

1.1 Names of parts

J Main parts Terminals P 2-6

Output unit P 2-3

Rear case

Input type jumper connector P 2-2 Option unit P 2-3

Front panel

J Front panel Operation indicators OUT1 OUT2 SUB1 MANU STOP RMT AT

No.2 display

SV OUT1 OUT2 MANU STOP RMT

A

A/M key A/M

AT

SUB1

M E5CK

Display key

1--2

No.1 display

PV

Down key

Up key

Page 10

E5CK

1.1 Names of parts

J About the displays F No.1 display

Displays the process value or parameter symbols.

F No.2 display

Displays the set point, manipulated variable or parameter settings.

F Operation indicators

• OUT1

: Lits when the pulsed output function assigned to “control output 1” is ON.

• OUT2

: Lits when the output function assigned to “control output 2” is ON.

• SUB1

: Lits when the output function assigned to “auxiliary output 1” is ON.

• MANU : Lits in the manual operation mode.

J How to use keys

• STOP

: Lits when operation has stopped.

• RMT

: Lits during remote operation.

• AT

: Flashes during auto-tuning.

The following describes basic key operations.

F A/M key

Each press of this key switches between the auto and manual operations.

key

The functions of this key change according to how long it is pressed. If the key is pressed for less than one second, the parameters are switched. If the key is pressed for one second or more, the menu display appears. In key

F operations from here on, “press the key” refers to pressing the key for less than one second. For details on parameter switching and menu display items, see page 1---7.

F key

Each press of the key increments or advances the values or settings on the No.2 display, while each press of the key decrements or returns the values or settings on the No.2 display.

Functions vary, for example, when the A/M key is held down simultaneously with the display key, or a key is held down continuously. For details, see page 1-7. Also, chapters 3 and 4 describe examples using various key combinations.

1--3