Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 1 of 4

F-30 Vision Sensor Operation Manual, pages 1 to 10

Pages 1 to 10 of 37

The original document is the PDF (465 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Omron F-30KP

Page 1

Cat. No. Z123-E1-1

F-30 Vision Sensor

OPERATION MANUAL

Page 2

F-30 Vision Sensor Operation Manual Produced July 1998

Page 3

General Precautions When the product is used under the circumstances below, ensure adherence to the limitations of the ratings and functions. Also, take countermeasures for safety precautions such as fail-safe installations. 1. Use under the circumstances or environment which are not described in the operation manuals. 2. Use for the equipment which requires higher level of safety such as nuclear devices, railroad, aircrafts, vehicles, combustion devices, amusement equipment/machinery, medical equipment, safety devices. 3. Use for the application where death, serious injury, or property damage is possible and extensive safety precautions are required.

Safety Precautions

! Caution ! Caution ! Caution ! Caution ! Caution ! Caution ! Caution

Do not use the F-30 in environments with flammable or explosive gases. Install the F-30 away from high-voltage equipment or motors to ensure safety during operation and maintenance. Use the power supply cables and crimp terminals of specified sizes. Use at the power supply voltages specified in this manual. Be sure to securely tighten the screws when mounting F-30 components. Do not dismantle, repair, or modify any F-30 components. Dispose of F-30 components as industrial waste.

Visual Aids The following headings will help you locate different types of information. Note Indicates information of particular interest for efficient and convenient operation of the product. Indicates pages where additional information can be found.

1

Indicates a procedure. The step numbers in the procedure correspond to the numbers in any related illustrations.

© OMRON, 1998 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high–quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.

1

Page 4

Contents 1

Introduction ............................................................................................. 3 1-1 Operational Flow ............................................................................. 3 1-2 Nomenclature .................................................................................. 3 1-2-1 Camera/Controller ................................................................ 3 1-2-2 Back of Controller................................................................. 4 1-3 Console (sold separately) ................................................................ 4 1-4 Screen Display ................................................................................ 5 1-5 Modes ............................................................................................. 6 2 Setup ...................................................................................................... 7 2-1 Settings: TEACH Mode .................................................................... 7 2-1-1 AUTO................................................................................... 7 2-1-2 MANUal ............................................................................... 8 2-2 Confirmation: MONitor Mode ..........................................................14 2-3 Operation: RUN Mode ....................................................................15 3 Installation..............................................................................................16 3-1 Preparing to Install .........................................................................16 3-1-1 Items Included.....................................................................16 3-1-2 Items Sold Separately .........................................................16 3-1-3 Items Commercially Available..............................................16 3-1-4 Environment........................................................................17 3-1-5 Distance from Object...........................................................17 3-2 I/O Power Supply Cable..................................................................18 3-2-1 I/O Interface ........................................................................19 3-2-2 Connecting the Red LED Illuminator ....................................19 3-2-3 Disconnecting the Red LED Illuminator................................20 3-2-4 Connecting the Monitor........................................................20 3-2-5 Connecting the Console.......................................................20 4 SPECIAL Mode.......................................................................................21 4-1 Accessing SPECIAL Mode..............................................................21 4-1-1 CHanGe DEFault ................................................................21 4-1-2 MODE.................................................................................21 4-1-3 SHUTTER ...........................................................................22 4-1-4 GATE ..................................................................................22 5 Troubleshooting......................................................................................24 5-1 Problems and Causes ....................................................................24 6 Inspection and Maintenance ...................................................................25 6-1 Periodic Inspections .......................................................................25 6-2 Maintenance...................................................................................25 6-2-1 Cleaning..............................................................................25 6-2-2 LED Illumination Device ......................................................26 A Specifications .........................................................................................27 B Dimensions ............................................................................................29 C Menu Tree ..............................................................................................31 Glossary.........................................................................................................32

2

Page 5

1 Introduction 1-1

Operational Flow

The F-30 operation is as follows:

Illumination/image reading The object to be measured is illuminated by a red LED light source. A signal from an external device TRIGGERs the shutter, and the object's image is captured.

Measurement The image is binarized, then measured.

Judgment inspection The measured object is judged against the set measurement conditions.

Display/signal output The judgment result and image are displayed. The judgment result signal and control signal (GATE signal) are sent to an external device. The judgment result signal can be HIGH: the object is too large, OK: the object's size is acceptable, or LOW: the object is too small.

1-2

Nomenclature

1-2-1

Camera/Controller Console (sold separately)

Console connector

Monitor output connector Camera/controller

I/O power supply connector (included)

OK indicator LED power supply connector RUN indicator (lights while power is applied)

I/O connecting cable (included)

LED illumination device

3

Page 6

1-2-2

Back of Controller

Mounting holes

1-3

Console (sold separately) Up arrow key

ENTer key

Left arrow key

Right arrow key

Down arrow key

Up and down arrow keys Left and right arrow keys ENTer key

Highlight modes/menus. Specifies setting values. Specify setting values. Selects specified (highlighted) mode/menu.

4

Page 7

1-4

Screen Display

The F-30 is operated by selecting the functions displayed on the screen.

Mode Display The right arrow indicates the current mode or menu.

Cursor The cursor (reverse display) is used to highlight the desired function. The function is selected when ENTer is pressed.

Region of Interest A selected area of the image to be inspected and analyzed. The region of interest is designated by a dotted line box.

Judgment Result The judgment result is displayed. Note: If a commercially available television (overscan display) is used for the monitor, it may not be possible to see all the display. With an underscan monitor, everything will be visible.

5

Page 8

1-5

Modes

The following functions are always displayed on the screen. Mode Settings: TEACH AUTO MANUal Confirmation: MONitor

Measurement: RUN

Explanation This mode is used to register the pass/fail conditions. Settings can be done in AUTO or MANUal. A simple means of setting the reference image, and each measurement criterion. The pass/fail conditions are set manually. This mode is used to confirm whether the measurement and judgment process is being performed accurately based on the pass/fail conditions. The TRIGGER signal is accepted, and the measurement result is displayed. No signal is output. This is the mode used for actual inspection. The object's image is recorded and measured when the TRIGGER signal is received from the external device. The judgment result is displayed on the monitor. The judgment result signal (HIGH/OK/LOW) and control signal (GATE signal) are sent to an external device. If the judgment result is OK, the OK indicator also lights.

The F-30 power can be turned OFF in any mode (screen). When the power is turned ON, the F-30 defaults to RUN mode.

6

Page 9

2 Setup 2-1

Settings: TEACH Mode

A few seconds after applying power, RUN mode begins, and measuring starts.

2-1-1

AUTO

AUTO sets the reference image, and pass/fail conditions automatically. This is the simplest way to get started. If AUTO is run after setting the criteria in MANUal, the MANUal settings will be lost.

(Binary image) Use the following steps to set the reference image and pass/fail conditions: 1. Highlight TEACH and press ENTer. AUTO and MANUal will be displayed. The cursor will highlight AUTO as the default, and the pass/fail conditions and original image will be displayed. 2. Press ENTer again. Criteria registration is now possible. The cursor waits at ENTer, and black and white is the default. 3. Move the object to be registered as the reference image until it is within the region of interest. 4. Press ENTer. The reference image and pass/fail conditions are registered. To change the registered settings, just follow the above steps again. Settings can be changed as often and as many times as desired. Because a red LED is used for illumination, a red object may not convert properly to binary.

7

Page 10

Note: If AUTO mode is entered by accident, it can be exited without changing any settings by pressing any of the arrow keys. The factory default settings are as follows: Measurement WINDOW (region of interest) size LEVEL (binary conversion level) WHT/BLK (target color for measuring) JUDGE (judgment criteria range)

2-1-2

Setting 40mm x 40mm 128 Black Low: 80% High: 120%

MANUal

MANUal mode can be used to set the measurement conditions individually. It can also be used to change some settings after setting all conditions with the AUTO mode.

(Original image) Use the following steps to set the reference image and pass/fail conditions: 1. Highlight TEACH and press ENTer. AUTO and MANUal will be displayed. 2. Highlight MANUal, and press ENTer again. Each criterion can now be set. WINDOW, LEVEL, WHT/BLK, JUDGE, SET-STD are displayed. The cursor waits at WINDOW. 3. Highlight the menu to set, and press ENTer. The menu for the selected setting will be displayed. Note: If AUTO mode is entered by accident, it can be exited without changing any settings by pressing any of the arrow keys.

8