Page 11

WINDOW Menu The WINDOW menu is used to set the size of the region of interest. The region of interest is displayed as a dotted line box on the monitor. Set point

(Original image) Highlight WINDOW and press ENTer. The set point is initially displayed in the upper-left of the frame. 1. Use the arrow keys to adjust the position of the upper-left corner of the frame. Pressing up and left together, or down and right together will adjust the corner diagonally. 2. Press ENTer when the upper-left corner is adjusted as desired. 3. The set point moves to the lower-right corner of the frame. Use the arrow keys to adjust the position of the lower-right corner of the frame. Pressing up and left together, or down and right together will adjust the corner diagonally. 4. Press ENTer when the lower-right corner is adjusted as desired. Note 1: Setting the size and position of the region of interest also updates the reference image. Always have the object being used as the reference image in position when setting the window menu. Note 2: To change the registered settings, just follow the above steps again. If a commercially available television (overscan display) is used for the monitor, it may not be possible to see all the display. With an underscan monitor, everything will definitely be visible.

9

Page 12

LEVEL Menu The LEVEL menu is used to set the binary conversion level.

(Binary image) Highlight LEVEL and press ENTer. The cursor is displayed on the binary conversion value. 1. Use the arrow keys to adjust the conversion level. The display will be updated simultaneously. 2. Press ENTer when the conversion is adjusted as desired. Note: Setting the conversion level also updates the reference image. Always have the object being used as the reference image in position when setting the LEVEL menu.

10

Page 13

WHT/BLK Menu The WHT/BLK menu is used to set whether the image is displayed in black or white.

(Binary image) Highlight [WHT/BLK] and press ENTer. The cursor is displayed on the previous selection (BLACK or WHITE). 1. Use the left or right arrow key to highlight the desired selection. 2. Press ENTer to set the desired selection. Note: Setting the WHT/BLK selection also updates the reference image. Always have the object being used as the reference image in position when setting the WHT/BLK menu.

11

Page 14

JUDGE Menu The JUDGE menu is used to set the HIGH/OK/LOW ranges for judgment.

(Binary image) Highlight [JUDGE] and press ENTer The cursor is displayed on LOW. 1. Use the arrow keys to set the desired LOW percentage. 2. Press ENTer when the LOW value is set as desired. 3. Use the arrow keys to set the desired HIGH percentage. 4. Press ENTer when the HIGH value is set as desired. Note 1: The LOW setting must be less than the HIGH setting. LOW can be 0 to 998; HIGH can be 1 to 999. Note 2: Setting the JUDGE menu doesn’t update the standard image. Note 3: To change the registered settings, just follow the above steps again.

12

Page 15

SET-STD Menu This menu is used to set the base image.

(Binary image) Highlight [SET-STD] and press ENTer. The cursor is displayed on LOW. 1. Move the object to be registered as the reference image until it is within the region of interest. 2. Press ENTer when the object is positioned properly. The base image setting can be confirmed by confirming that the pixel value is updated. Note 1: To change the registered settings, just follow the above steps again. Criterion will be updated by the last registration. Note 2: To be back to the previous selected menu from [SET-STD] entered by accident, press any of the arrow keys.

13

Page 16

2-2

Confirmation: MONitor Mode

Operation is tested based on the data registered. No output signal is generated. This mode is only for confirming operation.

(Binary image) 1. Highlight MONitor and press ENTer. The MONitor mode screen will be displayed. 2. Position the object to measure, and press ENTer again. The judgment result and image are displayed on the monitor. Confirm that the appropriate result (HIGH/OK/LOW) is displayed on the screen. If the result is OK, the OK indicator will also light. Note 1: None of the signals are output when testing in MONitor mode. Note 2: If the judgement result keeps OK, the OK indicator also keeps lighting. Note 3: When the judgement result is NG, HIGH or LOW indicator lights. Operation will be tested each time ENTer is pressed. Once proper operation has been confirmed, change to RUN mode to begin normal operation.

14

Page 17

2-3

Operation: RUN Mode

Normal measuring operation is performed after all pass/fail conditions have been confirmed.

(Binary image) 1. Highlight RUN and press ENTer. The RUN mode screen will be displayed. 2. The object's image is recorded and measured when the TRIGGER signal is received. The judgment result is displayed on the monitor. The judgment result signal (HIGH/OK/LOW) and control signal (GATE signal) are sent to an external device. If the judgment result is OK, the OK indicator also lights. Note 1: Do not press ENTer when measuring by the TRIGGER signal. Measuring is initiated by either the TRIGGER signal or pressing ENTer. To avoid inaccurate results, remove the console when operating in RUN mode. Note 2: Red LED illumination darkens in time. It is therefore necessary to re-register the reference image periodically to get new readings as the LED darkens. The LED darkens at a rate of about 30% after 10,000 hours of operation.

15

Page 18

3 Installation 3-1

Preparing to Install

The following items are required to install the F-30.

3-1-1 l l l l l l

Items Included

F-30 I/O power supply cable (cable length: 1.5 m (59.1”)) Console connector cover Monitor output connector cover Lens cover This manual

F-30

II/O power supply cable

3-1-2 l

Console (F-30KP; cable length: 1.5 m (59.1”))

3-1-3 l l l l l

Items Sold Separately

Items Commercially Available

Monitor Video signal cable (RCA pin plug) 12VDC power supply (10 W min.) External devices (PLC, etc.) Screw driver

16

Page 19

Note: Some monitors may not make it available to connect the video input connector with RCA pin plug.

3-1-4

Environment

The location of the installation must meet the following criteria: l Ambient temperature: 0 to 40 (32 to 104°F) l Avoid sudden temperature changes l No condensation l Avoid exposure to direct sunlight l Avoid sudden changes in lighting l Ambient humidity: 35 to 80% l Avoid locations subject to vibration or impact l Avoid excessive dust, salt, iron l Avoid splatter from water, oil, and chemicals l Avoid corrosive and flammable gases Note: Have the original image displayed in TEACH mode, and confirm the setting of F-30.

3-1-5

Distance from Object

Refer to the following figure to determine the proper mounting distance from the object to be measured:

F-30

Object to be measured

Working distance between camera and object (115 mm; 4.53”)

When the F-30 is shipped from the factory, the lens is positioned to be in focus at the distance shown above. Do not loosen the lens mounting screws. Any adjustment to the lens may result in inaccurate operation.

17

Page 20

The center of the measuring area is 7.5 mm (0.30”) off the horizontal center of the lens. Be sure to check the positioning on the monitor before mounting the camera.

F-30

Axis of lens center

Object

About 7.5 mm (0.30”)

Monitor

Measuring area center

3-2

I/O Power Supply Cable

1. Strip the ends of the wires on the I/O power supply cable. 2. Confirm the correct connections and secure each wire to the appropriate terminal of the power supply. Refer to the figure below. 3. Attach the I/O power supply cable connector to the F-30. 4. Use a voltmeter to confirm that the voltage across each connection is appropriate. Improper voltage will cause a malfunction. Use regular screwdriver when disconnecting the I/O power supply cable.

18