Page 21

Note: Be sure no weight is applied to the I/O power supply cable. If there is a chance that more than 0.5 kg will be applied, secure the cable firmly near the connector on the controller. Signal:

3-2-1

Wire color: Violet White Yellow Black Orange Red Green Blue Brown

I/O Interface Input No. of inputs Input voltage ON current ON voltage OFF current OFF voltage

Output No. of outputs

1 (TRIGGER) 12 to 24VDC ±10% 3 to 10 mA 8.8V 1 mA, min. 4.5V, min.

3 result: HIGH/OK/LOW 1 control: GATE 12 to 24VDC ±10% 50 mA, max. 3V, max.

Output voltage Load current ON residual voltage Leakage 0.4 mA, max. current Internal circuit diagram

Internal circuit diagram

Each output terminal

Input terminal

Removal 1. Disconnect all the devices from DC12 V and F-30. 2. Grasp the plug of I/O interface and pull it out of F-30. Note: Do not force the connector when disconnecting.

3-2-2

Connecting the Red LED Illuminator

Connect the LED illuminator connecting cable securely to the LED power supply connector on the F-30.

19

Page 22

3-2-3

Disconnecting the Red LED Illuminator

1. Disconnect the power to the F-30. 2. Hold the connector firmly to remove it from the F-30. (Never pull on the wires.) Note: Do not force the connector when disconnecting.

3-2-4

Connecting the Monitor

Connect the RCA pin plug video cable securely to the monitor output connector on the F-30. Note: Be sure to use the cover to keep the connector clean whenever the monitor is not connected.

3-2-5

Connecting the Console

Connect the console cable securely to the console connector on the F-30. It will click into place when connected properly.

Disconnecting the console 1. Pull the plug out of the console connector on the F-30 with pushing down its pick. Note 1: Do not force the connector when disconnecting. Note 2: Be sure to use the cover to keep the connector clean whenever the console is not connected.

20

Page 23

4 SPECIAL Mode 4-1

Accessing SPECIAL Mode

There is normally no need to change settings in this mode, but if it is necessary, go into TEACH mode, and while simultaneously pressing the left and right arrows, press ENTer. The following menus can be selected: • CHanGe DEFault • MODE • SHUTTER • GATE Function symbol CHG-DEF (CHanGe DEFault)

Description

Default settings

Used for changing measurement conditions under the AUTO mode.

MODE

Used for changing the measurement mode. Used for selecting the shutter speed. Used for setting the output time of gate signals.

WINDOW: 40 mm x 40 mm LEVEL: 128 WHT/BLK: BLACK JUDGE: LOW=80%, HIGH= 120% TRIGGER

SHUTTER GATE

4-1-1

1/1000 10 ms.

CHanGe DEFault

This menu is used to change the default values used in the AUTO mode. The default values for the following items can be changed: • WINDOW • LEVEL • WHT/BLK • JUDGE

4-1-2

MODE

This menu is used to select the method of initiating measuring. TRIGGER Measuring is initiated by the TRIGGER signal. CONTINUE Measuring is continuous. When set to CONTINUE, do not allow input of the TRIGGER signal. Pressing ENTer will not affect operation. Use the left and right arrow keys to highlight the desired setting, and press ENTer.

21

Page 24

4-1-3

SHUTTER

This menu is used to set the shutter speed. Watching the display, use the left and right arrow keys to highlight the desired shutter speed, and press ENTer. Possible selections are as follows: • 1/60 second • 1/100 second • 1/250 second • 1/500 second • 1/1000 second • 1/2000 second • 1/4000 second

4-1-4

GATE

This menu is used to set the control signal length. Refer to the following time charts, and use the arrow keys to set the desired time, then press ENTer. The time that can be set is 1-99 ms.

TRIGGER Measuring

TRIGGER signal Shutter Measurement Judgement result Gate signal

T1: TRIGGER signal pulse width (50s, min.) T2: Delay from TRIGGER signal input to shutter operation (0.1 ms, max.) T3: Delay from TRIGGER signal input to GATE signal output (50 ms, max.); this time depends on the shutter time. T4: GATE signal output time; set this time so that T2 and T3 do not exceed the minimum length of time between TRIGGER signals. The TRIGGER signal is not accepted during measurement processing. Signal TRIGGER HIGH/OK/LOW GATE

Function Initiates measurement; ignored during measurement processing. Indicates judgment result; time delay from TRIGGER input depends on the shutter speed setting. On during judgment result signal output; duration can be set from 1 to 99 ms.

22

Page 25

CONTINUE Measuring Internal synch. signal Shutter Measurement Judgement result Gate signal

T3: Delay from shutter (internal synchronization signal) start to GATE signal output. If the shutter speed is set to 1/100 max., this time is about 33.4 ms; at a shutter speed of 1/60, it is about 50 ms. T4: GATE signal output time; the above timing chart is based on this time being set to 1 to 46 ms. The shutter is opened, and measurement processing performed every 50 ms. If this time is set to 47 to 96 ms, measurement processing is performed every 100 ms.

23

Page 26

5 Troubleshooting 5-1

Problems and Causes

Refer to the following table to determine the cause of any difficulty, and implement the countermeasures indicated. If the problem persists, contact your Omron representative. Problem Cause/countermeasure RUN indicator does Confirm that the power supply, and I/O power supply not light. are both connected with the correct voltage. OK indicator does If the monitor indicates that the judgment result is OK, not light. but the OK indicator does not light, the F-30 needs to be repaired. Nothing is Power is not supplied to the monitor; the monitor is not displayed on the securely connected to the F-30, or the monitor is monitor. broken. The image is not The lens cover is on the lens, the LEVEL needs displayed. (Frame adjustment, or the object is red. and mode are.) The monitor image The monitor horizontal/vertical controls need is distorted. adjustment, or electrical noise is affecting the video signal. The judgment The F-30 is not in RUN or MONitor mode, or nothing is result is not being measured (no TRIGGER signal is received displayed on the (RUN), or ENTer is not being pressed (MON)). monitor. The mode indicator An overscan monitor is being used. The full screen (arrow) is not may not fit on an overscan monitor. displayed. Console input is The console is not properly connected. not accepted. The TRIGGER The F-30 is not in RUN or MONitor mode, or the cables signal is not are not connected properly. accepted. Output signals are The F-30 is not in RUN mode, cables are not not being output. connected properly, GATE signal output time is too short, or nothing is being measured (no TRIGGER signal is received, or ENTer is not being pressed). The LED The power is not supplied to the F-30, or to the LED illumination device illumination device. does not light. Part of the LED Some of the LEDs are burnt out, or the LED illumination device illumination device needs repair. does not light. The F-30 does not The image is not being read properly (i.e., LED measure properly. illumination is insufficient, TRIGGER signal timing is not accurate, etc.), or the judgment criteria are not set properly.

24

Page 27

6 Inspection and Maintenance 6-1

Periodic Inspections

Inspect the following items periodically: Item Power supply voltage Ambient temperature Ambient humidity Mounting condition

Monitor output connector LED illumination device

Console connector Other

Condition Use a voltmeter to confirm that the voltage supplied to the controller is 10.8 to 13.2VDC. Confirm that the ambient temperature is 0 to 40 (32 to 104°F). Confirm that the ambient humidity is 35 to 80%. Confirm that all cable connections are secure. Be sure that the controller, the LED illumination device, and the lens are all mounted and tightened firmly. If the monitor is not connected, be sure the monitor output connector cover is in place. Be sure that all the LEDs light when power is supplied. The expected life span of the LED illumination device is about 10,000 hours. It is best to replace the device at about that point, before the old one darkens completely. Be sure that the console connector cover is in place if the console is not connected. Confirm that there is no condensation, no dust or dirt, etc. anywhere on the controller, lens, LEDs, etc.

6-2

Maintenance

6-2-1

Cleaning

Tools Tester Thermomet er Hygromete r Phillips screwdriver

___ ___

___ ___

Use a soft cloth to remove any dust or dirt from the F-30 controller To remove dust or dirt from the lens or LED illumination device, use a special lens cloth or air brush. Note: Do not use benzene or thinner on any part of the Controller, at any time.

25

Page 28

6-2-2

LED Illumination Device

The LED illumination device should be replaced approximately every 10,000 hours. 1. Disconnect the power and all the other cables from the F-30. 2. Remove the F-30 from its mounted location. 3. Disconnect the LED illumination device cable from the F-30. 4. Remove the 4 screws holding the LED illumination device.

LED illumination device mounting screws

5. Attach the new LED illumination device, and secure it with the 4 mounting screws. 6. Connect all the cables, and power supply. 7. Confirm that all the LEDs light properly. 8. Register the level and base image with the new LED illumination device.

26

Page 29

A

Specifications Item Judgment method Measuring surface Visual area

Working distance range Setting method Operation method Window Binary conversion level Processing speed Judgment result output Interface input Interface output Shutter timing Image element No. of pixels used Processing pixels Lens mount Scanning method Video output Video signal output Settings memory Input power supply Power consumption Noise resistance

Description Surface area measurement by binary conversion (level: 256) Black or white selectable 50 mm (1.97”) x 50 mm (1.97”) (at working distance=115 mm (4.53”); with an underscan monitor) 100 to 130 mm (3.94 to 5.12”) Automatic or manual Menu selection 1 rectangular window 256 50 ms, max. (at shutter speed=1/100 second, max.) 3 levels of output signal (HIGH/OK/LOW) and monitor display 1 TRIGGER, pulse width: 50s, min. 3 judgment: HIGH, OK, LOW 1 control: GATE TRIGGER: external signal CONTINUE: internal signal CCD fixed element (0.5 inch) 510 H x 492 V 407 H x 480 V C mount 2:1 interlaced EIA (RS-170 standard) 1.0Vpp/75 (pin plug) (See note) EEPROM (no. of writes: 100,000) 12VDC ±10% 10W, max. (1A, max.) Normal mode: 400Vpp Common mode: 1,500Vpp Pulse width 1s: leading edge 1 ns 0 to 40 (32 to 104°F)

Operating temperature Operating humidity 35 to 80% (no condensation) Environment No corrosive gases Storage temperature -20 to 60 (-4 to 140°F) Storage humidity 20 to 80% (no condensation) Vibration resistance 10 to 150 Hz (each vibration: 0.15 mm) 2 Impact resistance 200 m/s (20G) Weight About 430 g (15 oz.) Note: Use an NTSC monitor with an external video input terminal.

27

Page 30

Accessories Item Console

Part number F-30KP (cable length: 1.5 m (59.1”))

Recommended Power Supplies Omron recommends use of one of the following power supplies: Input voltage 100-240VAC 100-240VAC 200-240VAC 200-240VAC 200-240VAC

Output current 1.2A 2.5A 1.0A 2.1A 4.2A

Capacity 15W 30W 10W 25W 50W

Part number S82K-01512 S82K-03012 S82J-6112 S82J-6212 S82J-6512

Note: Built-in noise filter with 20ms min. voltage retention at 2% pp max. ripple voltage.

Replacement Parts Item LED illumination device

Part number F-30L1

28