The text of a manual · part 1 of 7
F300 Visual Inspection System Specifications and Installation Manual, pages 1 to 10
Pages 1 to 10 of 65
The original document is the PDF (574 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron F300-A20, Omron F300-C10EV2, Omron F300-D, Omron F300-E, Omron F300-FM, Omron F300-FS and Omron F300-P
Page 1
F300 Visual Inspection System Specifications and Installation Manual Revised March 1994
Page 2
iv
Page 3
Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to head precautions can result in injury to people or damage to the product.
DANGER!
Indicates information that, if not heeded, is likely to result in loss of life or serious injury.
WARNING Indicates information that, if not heeded, could possibly result in loss of life or serious injury. Caution
Indicates information that, if not heeded, could result in relative serious or minor injury, damage to the product, or faulty operation.
OMRON Product References All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation “PLC” means Programmable Controller (Programmable Logic Controller) and is not used as an abbreviation for anything else.
Visual Aids The following headings appear in the left column of the manual to help you locate different types of information. Note Indicates information of particular interest for efficient and convenient operation of the product. 1, 2, 3...
1. Indicates lists of one sort or another, such as procedures, checklists, etc.
OMRON, 1992 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.
v
Page 4
vi
Page 5
TABLE OF CONTENTS SECTION 1 System Overview and Configuration . . . . . . . . . . . . . . . . . 1-1 1-2
System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 Specifications and Features . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-2 2-3
Required Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Expansion Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F300 Camera Lenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-2 3-3 3-4 3-5
Installation Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Base Unit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting the Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Supply Unit Wiring and Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Supply Unit I/O Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 Inspection, Maintenance, and Troubleshooting . . . . . . . . 4-1 4-2 4-3
Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 2 6
9 10 22 34
39 40 41 42 44 47
55 56 56 58
59 61 vii
Page 6
About this Manual: This manual describes the basic installation and specifications of Units used in F300 Visual Inspection System and includes the sections described below. Please read this manual completely and be sure you understand the information provided before attempting to install and operate an F300 Visual Inspection System. Section 1 presents a brief introduction to the F300 Visual Inspection System, its required Units, and optional Units. This section also includes examples of system configurations. Section 2 describes the basic components and operational specifications of each Unit in the F300 Visual Inspection System. Section 3 describes operational, installation, and wiring requirements for the F300 Visual Inspection System. Section 4 explains how to inspect and maintain the F300 Visual Inspection System and troubleshooting procedures to follow should problems occur.
WARNING Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given.
ix
Page 7
SECTION 1 System Overview and Configuration This section presents a brief introduction to the F300 System, its required Units, and optional Units. It also includes examples of system configurations. 1-1
1-2
System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1-1 Required Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1-2 Optional Expansion Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2-1 Basic System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2-2 Expanded System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 2 4 6 6 7
1
Page 8
Section 1-1
System Components
1-1
System Components After receiving the F300 System, make sure that following Units are delivered as ordered.
1-1-1 Required Units The following Units are essential in the configuration of the F300 System. You will need at least one of each type of Unit to construct an F300 System.
F300-B_ Base Unit A Base Unit supplies power to other Units mounted on it, such as Camera I/F Units and I/O Units. Base Units are available with either 3 slots or 5 slots. Either can be used depending on System size. A Base Unit with various Units mounted to it to form a functional entity is called a Rack. 5-slot Base Unit (F300-B5)
Front Cover for 5-slot Base Unit
3-slot Base Unit (F300-B3)
Front Cover for 3-slot Base Unit
F300-P/PE Power Supply Unit The Power Supply Unit converts 100- to 240-VAC power to DC power for the Units mounted to the Base Unit. The voltages set before shipping are as follows: • F300-P:
100 to 120 VAC
• F300-PE: 200 to 240 VAC
2
Page 9
Section 1-1
System Components F300-C10EV2/C11E IMP Unit The IMP (Image Processing) Unit processes measurements.
F300-FM MMI Unit The MMI (Man-Machine Interface) Unit is used to connect the Console, the Video Monitor, and memory cards.
F300-KP Console The Console is connected to the MMI Unit and is used to execute commands and input settings.
F300-M09 Video Monitor (100 VAC) The Video Monitor is required to set F300 data and programs, check images, and display measurement results.
F309-VM Monitor Cable (2 m) Note
The F309-VM Monitor Cable incorporates a BNC connector, via which NTSC-standard video signals will be output to the Video Monitor.
3
Page 10
Section 1-1
System Components F300-A20__ Camera I/F Units
A Camera I/F Unit inputs video signals from a camera to the F300. Four types of Camera I/F Unit are available to suit different applications. Two cameras can be connected to each Camera I/F Unit. Order the lens separately.
F309-VS_ Camera Cable (5 m)
Unit Camera I/F Unit
Input
Model
Normal
F300-A20
Normal, simultaneously
F300-A20S
Shutter
F300-A20R
Shutter, simultaneously
F300-A20RS
F300-S Camera
Camera
Camera Cable
F300-S CCD Video Camera
F309-VS (5 m)
PJLG-55-Z CCD Shutter Video Camera
F309-VSR (5 m)
1-1-2 Optional Expansion Units Expansion Units are optional and are available to further extend the capabilities of the F300 System.
I/O Units I/O Units can be used to input measurement commands from external devices and to output results. Select the Unit to suit the application from the Terminal Block Unit, Parallel I/O Unit, or RS-232C I/F Unit.
F300-VR RS-232C Cable F300-D Terminal Block Unit
F300-DC Parallel I/O Unit
F300-E RS-232C I/F Unit
(25-pin connector, 5 m)
Note Both the Terminal Block Unit and Parallel I/O Unit are identified as I/O Unit (F300-D) and I/O Unit (F300-DC) on the actual units. Unit
No. of I/O
Cable
F300-D Terminal Block Unit
Inputs: 8 Outputs: 8
None
F300-DC Parallel I/O Unit
Inputs: 8 Outputs: 32
50P L connector (included with Unit)
F300-E RS-232C I/F Unit
RS-232C interface: 2 channels
F300-VR (25-pin connector, 5 m). If the connector is different. Refer to 2-2-5 F300-E RS-232C I/F Unit for cable connections in detail.
4
Application Connect to a programmable controller or other device to input measurement commands and output measurement results. Connect to a computer or other device equipped with an RS-232C interface to input measurement commands and output measurement results.