What is in it
Omron's specifications and installation manual for the F300 Visual Inspection System. It introduces the required Units (Base Unit, F300-P/PE Power Supply, IMP Unit, F300-FM MMI Unit, Console, Video Monitor, F300-A20 Camera I/F Units) and the optional expansion Units such as the F300-D Terminal Block Unit and F300-E RS-232C I/F Unit, gives each Unit's specifications and camera lens data, and covers installation, power and I/O wiring, inspection, maintenance and troubleshooting.
Its parts
- System Overview and Configuration
- Specifications and Features
- Installation
- Inspection, Maintenance, and Troubleshooting
From the manual
Key facts from this manual
Each line names its page in the PDF.
A specifications and installation manual, revised March 1994, for the Omron F300 Visual Inspection System. It describes each unit of the system, including the F300-B3 and F300-B5 Base Units, F300-P/PE Power Supply Unit, F300-C10EV2/C11E IMP Unit, F300-FM MMI Unit, F300-A20 Camera I/F Units, F300-FS Strobe I/F Unit, F300-D Terminal Block Unit, F300-DC Parallel I/O Unit and F300-E RS-232C I/F Unit. It gives their specifications, terminal allocations, fuse replacement and a troubleshooting table.
- System
- Omron F300 Visual Inspection System: units mount on a 3-slot (F300-B3) or 5-slot (F300-B5) Base Unit to form a Rack p. 8
- Unit environment
- Power supply, IMP, MMI, Camera I/F, Strobe and I/O units: 0°C to 50°C operating, –25°C to 65°C storage, 35% to 85% RH without condensation, IP20 (in-panel) p. 17, 19, 20, 24, 27, 30, 33, 37
- F300-D I/O
- F300-D: 8 data inputs and 8 data outputs plus AND and OR outputs, 12 to 24 VDC, outputs 100 mA max. p. 31
- F300-D signals
- F300-D: RESET resets the F300, STEP runs one measurement, DSA requests data output; BUSY and GATE outputs p. 31
- F300-E serial
- F300-E: 2 RS-232C channels, 19,200 bps max.; F300-VR cable (25-pin connector, 5 m) p. 10, 37
- F300-P input
- F300-P set for 100 to 120 VAC, F300-PE for 200 to 240 VAC; 85 to 132 VAC or 170 to 264 VAC selectable, 50/60 Hz p. 8, 17
- F300-P outputs
- F300-P/PE: 5 VDC 7 A, 13 VDC 4.5 A and –12 VDC 0.9 A to the units; 12 VDC 0.3 A service supply; RUN and ERROR photocoupler outputs p. 18
- Power supply fuse
- AC 100: 125 V, 6.3 A, MF51NM, 5.2 dia. x 20 mm; AC 200: 250 V, 3.15 A, MF51NM, 5.2 dia. x 20 mm p. 62
- Camera I/F models
- F300-A20 (normal), F300-A20S (normal, simultaneously), F300-A20R (shutter), F300-A20RS (shutter, simultaneously); up to two cameras each p. 23
- Camera cables
- F309-VS (5 m) for the F300-S CCD Video Camera; F309-VSR (5 m) for the PJLG-55-Z CCD Shutter Video Camera p. 10
- F300-FM MMI
- F300-FM: connects the F300-KP Console, the F300-M09 Video Monitor (F309-VM cable, BNC, NTSC) and memory cards p. 9
- Memory cards
- F300-N256/512, storing scene data, system data and OVL programs p. 13
- IMP Unit
- F300-C10EV2/C11E: processes measurements; POWER, RUN and ERROR indicators; battery for memory back-up p. 19
- Unit weights
- F300-P approx. 1.7 kg; IMP Unit approx. 1.8 kg; F300-FM approx. 660 g; F300-FS, F300-D and F300-E approx. 400 g each p. 18, 19, 20, 28, 33, 38
What this manual walks you through
- Checking that every unit ordered was delivered p. 8
- Basic and expanded system configurations p. 12, 13
- Base Unit dimensions and mounting holes p. 16, 17
- F300-D terminal allocations p. 32
- F300-DC Parallel I/O Unit terminal allocation p. 35
- Wiring a computer to the F300-E with the F300-VR cable p. 37
- Setting the F300-S camera switches p. 25, 26
- Replacing the Power Supply Unit fuse p. 62
- Troubleshooting indicator, image and input problems p. 62
Good to know
- The F300-D and F300-DC are labeled I/O Unit (F300-D) and I/O Unit (F300-DC) on the units themselves. p. 10
- Camera I/F Units come without a lens; order it separately. p. 10
- The F300-VR uses a 25-pin connector; check the computer's pin arrangement before wiring. p. 37
- Do not adjust the F300-S GAIN trimmer, and leave its AGC and shutter switches off. p. 25
- Turn off the F300 System before replacing the fuse. p. 62
Questions this manual answers
How many inputs and outputs does the Omron F300-D have?
8 data inputs and 8 data outputs, plus AND and OR outputs, all at 12 to 24 VDC. p. 31
What fuse does the F300 Power Supply Unit take?
For AC 100: 125 V, 6.3 A, MF51NM, 5.2 dia. x 20 mm. For AC 200: 250 V, 3.15 A of the same type and size. p. 62
What cable connects the F300-E RS-232C I/F Unit to a computer?
The F300-VR cable, with a 25-pin connector and 5 m long. p. 10
How many cameras can one F300 Camera I/F Unit take?
Up to two cameras per Camera I/F Unit. p. 23
What does the STEP input on the F300-D do?
It runs one measurement. p. 31