The text of a manual · part 5 of 7
F300 Visual Inspection System Specifications and Installation Manual, pages 41 to 50
Pages 41 to 50 of 65
The original document is the PDF (574 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron F300-A20, Omron F300-C10EV2, Omron F300-D, Omron F300-E, Omron F300-FM, Omron F300-FS and Omron F300-P
Page 41
Section 2-3
F300 Camera Lens
2-3-3 Magnification Lens, Field of Vision and Working Distance Magnification
Model
Field-ofview (mm)
Working distance (mm)
Overall length (mm)
L’ (mm)
End diameter 14 mm dia.
2/3-inch CCD
1/3-inch CCD
1/2-inch CCD
3Z4S-LE ELE-008-2.5
2.5
1.5
1.9
2.6
45.8
48.6
54
3Z4S-LE ELE-008-4
4
0.9
1.2
1.6
43.9
67.0
70
3Z4S-LE ELE-008-6
6
0.6
0.8
1.1
42.9
91.5
97
3Z4S-LE ELE-009-2
2
1.8
2.4
3.3
73.7
67.4
72
3Z4S-LE ELE-009-4
4
0.9
1.2
1.6
69.2
103.3
108
3Z4S-LE ELE-009-6
6
0.6
0.8
1.1
67.8
139.3
144
22 mm dia.
L’ C mount
Object
34 dia.
End diameter
Ring nut W.D.
L
Working distance
Overall length
17.5
2-3-4 Extension Tubes Extension tubes are used to move the camera closer to the object, outside the focal adjustment range of the lens. The tubes are available as a set of six. Model 3Z4S-LE EX-C6
Thickness
Comment
0.5 mm, 1 mm, 5 mm, 10 mm, 20 mm, 40 mm
Use a combination of tubes to give the required thickness.
Length: 40 mm
20 mm
10 mm
5 mm
1.0 mm 0.5 mm
2-3-5 Teleconverter Insert the Teleconverter between the lens and the camera to double the focal length. Model 3Z4S-LE 2-EX
36
Max external diameter 30. 5 mm
Thickness 11.5 mm
Page 42
Section 2-3
F300 Camera Lens
The following diagram provides the external dimensions for the 2-EX Teleconverter used with the F300 System. Unless otherwise noted, values are in millimeters (mm). 4 1% - 32 UN–2 A
30.5 dia.
11.5
4
2.5
Note The focal length and brightness change in proportion to the teleconverter magnification. Note that the markings on the lens focus ring and aperture ring are not accurate when the teleconverter is used. These settings must be adjusted to compensate for the teleconverter magnification factor.
37
Page 43
SECTION 3 Installation This section describes the operational, installation, and wiring requirements of the F300 System. 3-1
3-2 3-3
3-4
3-5
Installation Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1-1 Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1-2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1-3 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Base Unit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting the Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-1 Mounting Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3-2 Mounting Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Supply Unit Wiring and Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4-1 Power Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4-2 Ground Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Supply Unit I/O Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5-1 Power Supply Unit I/O Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5-2 Connecting Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40 40 40 41 41 42 42 44 44 45 46 47 47 49
39
Page 44
Section 3-1
Installation Environment
3-1
Installation Environment The F300 System is highly reliable and resistant to environmental factors. The following guidelines, however, must be followed to ensure reliability and to get full use of the System.
3-1-1 Location Do not install an F300 System in locations subject the following conditions: • Temperatures outside 0%C to 50%C • Condensation due to rapid temperature fluctuations • Relative humidity outside 35% to 85% RH • Corrosive or flammable gas • High concentrations of dust, salt, or iron particles • Direct vibration or shock • Direct sunlight • Water, oil, or chemicals fumes or spray
3-1-2 Installation Consider environmental factors and ease of operation and maintenance when installing the F300 System in a control box. Temperature Considerations The operational temperature range of the F300 System is 0%C to 50%C. Take the following measures to maintain the F300 System in this range. • Maintain a minimum of 50-mm clearance above and below the F300 System to improve air flow. • Do not install the F300 System immediately above strong heat sources, such as heaters, transformers, or large-capacity resistors. • Provide a forced-air fan or air conditioning if the ambient temperature exceeds 50%C. Control box
F300
Fan
ÇÇ ÇÇ Louver
Operation and Maintenance Considerations
Keep the F300 System away from high-voltage equipment and motors to improve safety during operation and maintenance. The F300 System is easiest to work with if installed between 1.0 and 1.6 meters above the floor.
Noise Considerations
Do not install the F300 System in a cabinet containing high-voltage equipment or within 200 mm of power lines. Fully ground the mounting plate. Power cable
200 mm min.
F300
200 mm min.
40
Page 45
Section 3-2
Base Unit Installation
3-1-3 Precautions Direction of Installation
Install the Unit vertically with the vents at the top and bottom to improve air circulation and heat dissipation. Do not install as shown in the right portion of the diagram below.
Exhaust
No
No
No Inlet
No Clearance
ÉÉÉÉ ÉÉ ÉÉ ÉÉ ÉÉ É ÉÉÉÉ
50 mm min.
Maintain at least 50 mm clearance above and below the F300 System to improve air circulation.
50 mm min.
3-2
Base Unit Installation
F300-B5 Base Unit Mounting Hole Dimensions
F300-B3 Base Unit Mounting Hole Dimensions
480
410
460+0.2
390+0.2
Finished Dimensions of Base Unit Mounting Holes 6
247 225+0.2
6.5
247 225+0.2
12 Four, M5 holes
Four, M5 holes
41
Page 46
Section 3-3
Mounting the Units
3-3
Mounting the Units
3-3-1 Mounting Positions The Camera I/F Units can be mounted of slots 3 to 6 of the 3-slot or 5-slot Base Unit. Expansion Units can be mounted of slots 4 to 8 of the 5-slot Base Unit or of slots 4 to 6 in the 3-slot Base Unit.
F300-P/PE Power Supply Unit
Required Units F300-C10EV2/C11E IMP Unit
F300-B3 Base Unit
F300-B5 Base Unit
F300-A20__ Camera I/F Unit
F300-FM MMI Unit
F300-FS F300-L100EV2 F300-E Strobe I/F Unit OVL Unit RS-232C I/F Unit
F300-DC Parallel I/O Unit
F300-D Terminal Block Unit
F300-G Dummy Unit
Note When mounting multiple Units, move the Camera Units toward the IMP Unit.
42
Page 47
Section 3-3
Mounting the Units Number of Mountable Units Type
Name
Model
5-slot Base Unit (F300-B5)
Required units
Power Supply Unit
F300-P
1
1
1
1
IMP Unit
F300-C10EV2/ 2 C11E
1
2
1
MMI Unit
F300-FM
9
1
7
1
Normal
F300-A20
3 to 6
4 total
3 to 6
4 total
Normal/Simultaneously
F300-A20S
Shutter
F300-A20R
Shutter/Simultaneously
F300-A20RS
Terminal Block Unit
F300-D
4 to 8
5
4 to 6
3
Parallel I/O Unit
F300-DC
2
1
RS-232C I/F Unit
F300-E
1
1
OVL Unit
F300-L100EV2
1
1
Strobe I/F Unit
F300-FS
2
2
F300-G
5
3
Slot
Camera I/F Units (see note)
I/O Units
Expansion Units Dummy Unit
3-slot Base Unit (F300-B3)
Max. number
Slot
Max. number
F300-PE
Note Always use identical Camera I/F Units. Do not use different Camera I/F Unit models together.
43
Page 48
Section 3-4
Power Supply Unit Wiring and Ground
3-3-2 Mounting Procedure 1, 2, 3...
1. Turn off the power supply to the F300 System. 2. Align the claw on the top of the Unit with the recess in the Base Unit and correctly align the connectors. 3. Keeping the Unit and Base Unit parallel, push the Unit flush against the Base Unit. 4. Tighten the mounting screws at the top and bottom of the Unit with a Phillips screwdriver. Mounting screw Claw Phillips screwdriver
Connectors
Unit Base Unit Mounting screw
Note Always turn off the power supply before mounting or removing a Unit. The Unit may be damaged if attached or removed while the power is on.
3-4
Power Supply Unit Wiring and Ground Connect F300 power cables and ground cables to the Power Supply Unit terminal block. The terminal block uses M4 screw connectors. Use the crimped connectors shown in the table below.
Crimped Connectors 7.5 max.
Recommended Parts
44
7.5 max.
An applicable cable from 1.04 to 2.63 mm2 should be used.
Page 49
Section 3-4
Power Supply Unit Wiring and Ground
3-4-1 Power Wiring Connect the F300 to a 100-VAC 50/60-Hz or a 200-VAC 50/60-Hz power supply. Remove the terminal block shorting bar if the system is connected to a 200-V power supply. Wiring Connections
100-VAC Power Supply
RUN signal output
RUN
ERROR signal output
ERR COM
12 VDC OUT 0.3 A max.
DC service power supply Ground: 100 W max.
GR
Line ground terminal
LG
Not used
NC
Closed: 100 to 120 V
100/200-VAC selector terminal
Open: 200 to 240 V
100 to 240 VAC
100/200 VAC, 50/60 Hz power terminals
200-VAC Power Supply
Shorting bar Installed when using 100 VAC.
AC power supply
Power Supply Voltage Range
Use a power supply in the specified voltage range. Power supply voltage
Allowable fluctuation range
Shorting bar
100 VAC
85 to 132 VAC
Shorting bar installed
200 VAC
170 to 264 VAC
Shorting bar removed
Note Insert a 250-V, 3.15-A fuse when using the system with a 200-V power supply. Refer to 4-2 Maintenance for the procedure to change the fuse.
45
Page 50
Section 3-4
Power Supply Unit Wiring and Ground Power Supply Capacity and Cable Sizing
Although the current consumption should not exceed 2 A for 100 VAC operation, surge current flows when the power is turned on. The power supply, protective circuit breakers, and cables must have sufficient capacity to prevent a voltage drop at startup.
Power supply MCCB
F300
MCCB
Other equipment
1, 2, 3...
1. Use cables with at least a 2mm2 cross-sectional area to prevent voltage drops. 2. Use twisted-pair cables to prevent inductive noise interference. 3. Do not connect the F300 System to power sources supplying other equipment. In particular, isolate the F300 System from inductive loads.
3-4-2 Ground Connections
GR
LG
Independent ground with at least a 2 mm2 cross-section cable.
Ground resistance: 100 W max.
The GR terminal is connected to ground. To eliminate danger of electric shock, ground in to a ground resistance of100 W max. using a cable with at least 2 mm2 cross-sectional area. The LG terminal is the noise filter neutral terminal. Ground the LG terminal to a Class III ground (100 W max.) by shorting it to the GR terminal with the shorting bar accessory if severe noise interferes with measurements. The ground cable should not exceed 20 meters.
46