The text of a manual · part 2 of 7
F300 Visual Inspection System Specifications and Installation Manual, pages 11 to 20
Pages 11 to 20 of 65
The original document is the PDF (574 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron F300-A20, Omron F300-C10EV2, Omron F300-D, Omron F300-E, Omron F300-FM, Omron F300-FS and Omron F300-P
Page 11
Section 1-1
System Components F300-FS Strobe I/F Unit
The Strobe Unit flashes the external strobe in synchronization with the image-input signal. Up to four Strobes can be connected to each Strobe Unit.
F309-FS Strobe cable (2 m)
The following Strobes can be connected to the Strobe Unit.
F300-L100EV2 OVL Unit The F300 can be operated using the OMRON Visual Language (OVL). Commands and data are input from a special keyboard connected to an OVL Unit.
F300-L100EV2 OVL Unit
F300-K Keyboard
F300-G Dummy Unit A Dummy Unit can be inserted into empty slots to improve external appearance, protect connectors, and maintain the strength of the Rack.
5
Page 12
Section 1-2
System Configuration
1-2
System Configuration A basic F300 System is shown below.
1-2-1 Basic System
F300-P Power Supply Unit
F300-C10EV2/C11E IMP Unit F300-A20__ Camera I/F Unit
F300-FM MMI Unit
F300-KP Console
F300-S Camera
F300-M09 Video Monitor (100 VAC)
6
Page 13
Section 1-2
System Configuration
1-2-2 Expanded System F300-A20__ Camera I/F Unit F300-C10EV2/C11E IMP Unit
F300-FS Strobe I/F Unit
F300-L100EV2 OVL Unit F300-E RS-232C I/F Unit
F300-N256/512 Memory Card Stores scene data, system data, and OVL programs.
F300P Power Supply Unit
MMI Unit F300-FM
F300-B5/F300-B3 Base Unit F300-KP Console F309-VS, F309-VSR Camera Cable
F300-D Terminal Block Unit F309-VM Monitor Cable
F300-S CCD Video Camera PJLG-55-Z CCD Shutter Video Camera F300-M09 Video Monitor (100 VAC)
F309-VR RS-232C Cable Strobe
Personal computer
Note 25-pin connector
F309-VFS Strobe Cable F300-K Keyboard
Data input and all settings are possible from the keyboard via the OVL Unit, as well as from the Console.
7
Page 14
SECTION 2 Specifications and Features This section describes the basic components and operational specifications of each Unit in a F300 System, 2-1
2-2
2-3
Required Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1-1 F300-B5/-B3 Base Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1-2 F300-P/PE Power Supply Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1-3 F300-C10EV2/C11E IMP Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1-4 F300-FM MMI Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1-5 F300-KP Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1-6 F300-M09 Video Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1-7 F300-A20__ Camera I/F Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1-8 F300-S Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Expansion Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2-1 F300-FS Strobe I/F Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2-2 F300-L100EV2 OVL Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2-3 F300-D Terminal Block Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2-4 F300-DC Parallel I/O Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2-5 F300-E RS-232C I/F Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2-6 F300-G Dummy Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F300 Camera Lenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-1 Types of Lens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-2 CCTV Lens, Field of Vision and Mounting Distance . . . . . . . . . . . . . . . . . . . . . . 2-3-3 Magnification Lens, Field of Vision and Working Distance . . . . . . . . . . . . . . . . . 2-3-4 Extension Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-5 Teleconverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 10 12 14 15 16 17 18 20 22 22 23 25 28 31 33 34 34 35 36 36 36
9
Page 15
Section 2-1
Required Units
2-1
Required Units One or more of each of the following types of Unit is required in any F300 System.
2-1-1 F300-B5/-B3 Base Unit The F300-B3 and F300-B5 Base Unit provide hardware slots sharing a common bus line on which all Units are mounted and connected.
Components The following illustrations show the essential components of the F300-B3 and F300-B5 Base Unit. 3-slot Base Unit (F300-B3) Power connector
IMP connector
I/O bus connector
Handle
MMI connector Mounting hole Camera bus connector
5-slot Base Unit (F300-B5) Power connector
IMP connector
I/O bus connector
Handle
MMI connector Mounting hole Camera bus connector
10
Page 16
Section 2-1
Required Units Dimensions and Weight
The following diagrams provide the weight, external dimensions, and mounting hole dimensions for the F300-B3 and -B5 Base Unit. Unless otherwise noted, all values are in millimeters (mm). F300-B3 3-slot Base Unit 152.7 37.2
480
247
Weight: approx. 2.7 kg
Unit
F300-B5 5-slot Base Unit 152.7 37.2
410
247
Weight: approx. 2.3 kg
Unit
Mounting Hole Dimensions 5-slot Base Unit (F300-B5) 480 460+0.2
247
225+0.2
Four, M5 holes
3-slot Base Unit (F300-B3) 410 390+0.2
247
225+0.2
Four, M5 holes
11
Page 17
Section 2-1
Required Units Base Unit Mounting Hole Shape 6
6.5
12
2-1-2 F300-P/PE Power Supply Unit The Power Supply Unit takes in AC power supplied to the F300 and converts it to DC power for each unit. The following illustration shows the essential components of the F300-P/PE Power Supply Unit.
Components Power indicator
Terminal block
Power switch Fuse holder cap
Specifications General Specifications (All F300 Units) Item
F300-P
F300-PE
Factory-set voltage setting
100 to 120 VAC (85 to 132 VAC)
Supply voltage
85 to 132 VAC or 170 to 264 VAC (selectable)
Supply frequency
50/60 Hz
Insulation
20 MW min. between all AC external terminals and GR terminal (at 500 VDC)
Dielectric strength
1,500 VAC, 50/60 Hz for 1 minute between all AC external terminals and GR terminal; detected current: 10 mA max.
Noise resistance
1500 Vp-p; pulse width: 1 ms; rising time: 1 ns (pulse)
Vibration resistance
10 to 150 Hz with 0.15-mm single amplitude
Shock resistance
20G (196 m/s2)
Ambient operating temperature
0%C to 50%C
Operating humidity
35% to 85% RH (no condensation)
Operating environment
No corrosive gases
Storage temperature
–25%C to 65%C
Ground
Ground resistance: 100 W max.
Enclosure rating
IP20 (in-panel)
12
200 to 240 VAC (170 to 264 VAC)
Page 18
Section 2-1
Required Units Performance Specifications Power supply
Supplied to Units
5 VDC +3%, 7 A 13 VDC +1%, 4.5 A –12 VDC +5%, 0.9 A
Service supply
12 VDC +5%, 0.3 A
AC power interruption detection time
10 ms min.
Outputs
Photocoupler
Output type
(RUN, ERROR) Output voltage
12 to 24 VDC +10%
Load current
100 mA max.
Residual voltage
2 V max.
Leak current
0.1 mA max.
Internal output circuits Output terminals
COM
Dimensions and Weight The following diagram provides the external dimensions and weight of the F300-P Power Supply Unit. Unless otherwise noted, values are in millimeters (mm). 84.6
133.5
14
250
Weight: approx. 1.7 kg
Base Unit
13
Page 19
Section 2-1
Required Units
2-1-3 F300-C10EV2/C11E IMP Unit The IMP (Image Processing) Unit is required by the F300 to process measurements. The following illustration shows the essential components of the IMP Unit.
Components Operation indicators POWER (green): Lit while power is on RUN (orange): Lit during processing ERROR (red): Lights when an error occurs
Battery holder cover. Contains battery for memory back-up.
Specifications General Specifications Ambient operating temperature
0%C to 50%C
Operating humidity
35% to 85% RH (no condensation)
Operating environment
No corrosive gases
Storage temperature
–25%C to 65%C
Enclosure rating
IP20 (in-panel)
Dimensions and Weight The following diagram provides the external dimensions and weight of the IMP Unit. Unless otherwise noted, values are in millimeters (mm). 139.6
133.5
14
250
Front cover
Weight: approx. 1.8 kg
14
Base Unit
Page 20
Section 2-1
Required Units
2-1-4 F300-FM MMI Unit The F300-FM MMI (Man-Machine Interface) Unit supports key inputs from the Console and image displays on the Video Monitor. The following illustrations shows the essential components of the F300-FM MMI Unit.
Components Eject button. Press to eject memory card. Memory card access indicator Lit in green when a memory card is inserted and the cover closed. Lit in orange during data transfer.
Memory card cover
Memory card connector
Console recess to store console when not in use. Console connector Connector cover
Video monitor connector
Specifications General Specifications Ambient operating temperature
0%C to 50%C
Operating humidity
35% to 85% RH (no condensation)
Operating environment
No corrosive gases
Storage temperature
–25%C to 65%C
Enclosure rating
IP20 (in-panel)
Dimensions and Weight The following diagram provides the external dimensions and weight of the F300-FM MMI Unit. Unless otherwise noted, values are in millimeters (mm). 44.6
135
14
250
Base Unit
Weight: approx. 660 g
15