Page 21

Section 2-1

Required Units

2-1-5 F300-KP Console The F300-KP Console is the main F300 input device for menu operations and data input. Connect the Console to the MMI Unit. For information on Console operation, refer to the F300 Visual Inspection System Menu Mode Operation Manual. The following illustration shows the essential components of the F300-KP Console Unit.

Components Magnet

Magnet Operation keys

Specifications General Specifications

16

Ambient operating temperature

0%C to 50%C

Operating humidity

35% to 85% RH (no condensation)

Operating environment

No corrosive gases

Storage temperature

–25%C to 65%C

Enclosure rating

IP20 (in-panel)

Page 22

Section 2-1

Required Units Dimensions and Weight

The following diagram provides the external dimensions and weight of the F300-FM MMI Unit. Unless otherwise noted, values are in millimeters (mm). 13

1.5

50

87

100

5.3 dia.

Weight: approx. 240 g (unit only)

2-1-6 F300-M09 Video Monitor The F300-M09 Video Monitor is an output device of the F300 and used to display input images from the camera, data values that have been set, and measurement results.

Components Front View

Rear View

Power indicator

Video Video input output terminal terminal

Power switch

Specifications General Specifications Ambient operating temperature

0%C to 40%C

Operating humidity

10% to 90% RH (no condensation)

Operating environment

No corrosive gases

Storage temperature

–25%C to 65%C

17

Page 23

Section 2-1

Required Units Detailed Specifications Rating

Performance

System

Number of scanning lines: 525 Horizontal frequency: 15.75 kHz Field frequency: 60 Hz

I/O impedance

75W, high impedance (selectable)

I/O level and polarity

Image: 0.7 V (peak to peak), positive Cycle: 0.3 V (peak to peak), negative

Screen size

164 x 123 mm (W x H)

Resolution

700 TV min. (at center)

Dimensions and Weight 30

220

250

215 125

145

6

185

Weight: approx. 5.8 kg

22 22

2-1-7 F300-A20__ Camera I/F Units Four types of Camera I/F Unit are available: Normal, Normal/simultaneously, Shutter, and Shutter/simultaneously.

Camera I/F Unit Models Unit Camera I/F Unit

Input

Model

Normal

F300-A20

Normal, simultaneously

F300-A20S

Shutter

F300-A20R

Shutter, simultaneously

F300-A20RS

Connectable cameras F300-S CCD Video Camera

Number of cameras Up to two cameras per Camera I/F Unit.

CCD Shutter Video Camera PJLG-55-Z

Note Select the external synchronization and non-interlace scanning methods of the CCD Shutter Video Camera by referring to the instruction sheet provided with the CCD Shutter Video Camera.

18

Page 24

Section 2-1

Required Units Components

The following illustration shows the essential components of the F300-A20__ Camera I/F Units.

Operation indicators CAMERA 0 (orange): Lit when camera is connected to camera connector #0 CAMERA 1 (orange): Lit when camera is connected to camera connector #1

Camera connector #0 Camera connector #1

Specifications General Specifications Ambient operating temperature

0%C to 50%C

Operating humidity

35% to 85% RH (no condensation)

Operating environment

No corrosive gases

Storage temperature

–25%C to 65%C

Enclosure rating

IP20 (in-panel)

Performance Specifications Item

F300-A20

F300-A20S

F300-A20R

F300-A20RS

Input

Normal

Normal/simultaneously

Shutter

Shutter/simultaneously

No. of connectable cameras

2 max

Connectable cameras

F300-S

PJLG-55-Z

Sync signal output

HD, VD both dependent on camera bus sync signal

HD: 15.734 kHz

Output amplitude

4 Vp-p, 1-kW negative pulse

4 Vp-p, 75-W negative pulse

Output pulse width

HD, VD both dependent on camera bus synchronous signal.

HD: 6.27 ms

Camera power output

12 V, 0.8 A (for 2 cameras)

12 V, 0.8 A (for 2 cameras) –12 V, 0.8 A (for 2 cameras)

Cable length

5 m (standard)

Weight

Approx. 400 g

Frequency

Approx. 550 g

VD: 59.94 Hz

VD: 9 H

Approx. 400 g

Approx. 550 g

19

Page 25

Section 2-1

Required Units Dimensions and Weight

The following diagram provides the external dimensions and weight of the F300-A20__ Camera I/F Units. Unless otherwise noted, values are in millimeters (mm). 34.6

133.5

14

250

Front cover

Base Unit

2-1-8 F300-S Camera The following illustration shows the essential components of the F300-S Camera.

Components AGC switch GAIN trimmer

SHT switch

F300-S Tripod attachment

GAIN trimmer

For the image amplifier. Do not adjust this trimmer.

AGC switch

Turns AGC on and off. Leave this switch off.

SHT switch

Turns the electronic shutter on and off. Leave this switch off.

20

Page 26

Section 2-1

Required Units Specifications General Specifications Power

12 VDC +10%

Ambient operating temperature

0%C to 50%C

Operating humidity

30% to 70%

TV system

Conforms to RS-170

Picture element

Interline CCD

Effective pixels

768 * 493 (H*V)

Scanned area

8.6 x 6.6 mm (equivalent to 2/3 inch)

Number of scan lines

525 lines

Scan method

2:1 interlace

Synchronization

Internal/external sync (automatically switchable)

Scan frequency

Horizontal: 15.734 kHz; Vertical: 59.94 Hz

Aspect ratio

4:3

Object illumination

Standard: 200 lux; F4 (3,200%K); AGC: ON; γ = 1.0 Minimum: 0.5 lux; F1.4; GAIN: MAX; γ = 0.45

Image output

VS: 1.0 Vp-p/75 W

Resolution

Horizontal: 570 lines; Vertical: 350 lines

S/N ratio

50 dBp-p/rms (AGC: OFF γ = 1.0)

AGC

Output level within +2dB for rated level fluctuations of +12 dB. Switchable ON/OFF with selector on panel. OFF on delivery.

Electronic shutter

1/1,000 s fixed. Switchable ON/OFF with selector on panel. OFF on delivery.

Lens mounting

C mount

Note Use the F300-S Camera with the electronic shutter and AGC set to OFF.

Dimensions and Weight The following diagram provides the external dimensions and weight of the F300-S Camera. Unless otherwise noted, values are in millimeters (mm).

98

44

29

35 10

45 22.75

1/4-20UNC, 6 mm deep

10

Weight: approx. 200 g

25 Two, M5 holes, 6 mm deep

21

Page 27

Section 2-2

Expansion Units

2-2

Expansion Units

2-2-1 F300-FS Strobe I/F Unit The following illustration shows the essential components of the F300-FS Strobe I/F Unit.

Components Strobe operation indicators (orange): Light when strobes 0 to 3 flash

Strobe connector Channel 0 Channel 1 Channel 2 Channel 3

Specifications General Specifications Ambient operating temperature

0%C to 50%C

Operating humidity

35% to 85% RH (no condensation)

Operating environment

No corrosive gases

Storage temperature

–25%C to 65%C

Enclosure rating

IP20 (in-panel)

Performance Specifications

22

Strobe connections

4 max.

Strobe trigger output

20 mA max. per Unit, photocoupler output

Strobe flash error input

Photocoupler input Input ON current: 3 mA min. Input OFF current: 1.5 mA max.

Page 28

Section 2-2

Expansion Units Dimensions and Weight

The following diagram provides the external dimensions and weight of the F300-FS Strobe I/F Unit. Unless otherwise noted, values are in millimeters (mm).

34.6

133.5

14

250

Front cover

Base Unit

Weight: approx. 400 g

2-2-2 F300-L100EV2 OVL Unit The OVL Unit extends the capabilities of the F300 to allow it to be operated using OVL (OMRON Vision Language). OVL was developed specifically for optical recognition and image measurement to permit more sophisticated measurements with a BASIC-like language. The OVL Unit’s keyboard also allows data input and system operation from the Menu mode in the same fashion as is possible from the Console.

Component

Keyboard connected indicator (green) Lit when the keyboard is connected.

Keyboard connector

23

Page 29

Section 2-2

Expansion Units Specifications General Specifications Ambient operating temperature

0%C to 50%C

Operating humidity

35% to 85% (no condensation)

Operating environment

No corrosive gases

Storage temperature

–25%C to 65%C

Enclosure rating

IP20 (in-panel)

Dimensions and Weight The following diagram provides the external dimensions and weight of the F300-L100E OVL Unit. Unless otherwise noted, values are in millimeters (mm). 34.6

133.5

14

250

Front cover

Weight: approx. 400 g

24

Base Unit

Page 30

Section 2-2

Expansion Units

2-2-3 F300-D Terminal Block Unit The F300-D Terminal Block Unit is connected to a programmable controller or other devices to input measurement commands and output measurement results. The following illustration shows the essential components of the F300-D Terminal Block Unit.

Components Input indicators (orange) Output indicators (orange)

I/O terminals

Specifications General Specifications Ambient operating temperature

0%C to 50%C

Operating humidity

35% to 85% RH (no condensation)

Operating environment

No corrosive gases

Storage temperature

–25%C to 65%C

Enclosure rating

IP20 (in-panel)

25