Page 21
Section 2-1
Required Units
2-1-5 F300-KP Console The F300-KP Console is the main F300 input device for menu operations and data input. Connect the Console to the MMI Unit. For information on Console operation, refer to the F300 Visual Inspection System Menu Mode Operation Manual. The following illustration shows the essential components of the F300-KP Console Unit.
Components Magnet
Magnet Operation keys
Specifications General Specifications
16
Ambient operating temperature
0%C to 50%C
Operating humidity
35% to 85% RH (no condensation)
Operating environment
No corrosive gases
Storage temperature
–25%C to 65%C
Enclosure rating
IP20 (in-panel)
Page 22
Section 2-1
Required Units Dimensions and Weight
The following diagram provides the external dimensions and weight of the F300-FM MMI Unit. Unless otherwise noted, values are in millimeters (mm). 13
1.5
50
87
100
5.3 dia.
Weight: approx. 240 g (unit only)
2-1-6 F300-M09 Video Monitor The F300-M09 Video Monitor is an output device of the F300 and used to display input images from the camera, data values that have been set, and measurement results.
Components Front View
Rear View
Power indicator
Video Video input output terminal terminal
Power switch
Specifications General Specifications Ambient operating temperature
0%C to 40%C
Operating humidity
10% to 90% RH (no condensation)
Operating environment
No corrosive gases
Storage temperature
–25%C to 65%C
17
Page 23
Section 2-1
Required Units Detailed Specifications Rating
Performance
System
Number of scanning lines: 525 Horizontal frequency: 15.75 kHz Field frequency: 60 Hz
I/O impedance
75W, high impedance (selectable)
I/O level and polarity
Image: 0.7 V (peak to peak), positive Cycle: 0.3 V (peak to peak), negative
Screen size
164 x 123 mm (W x H)
Resolution
700 TV min. (at center)
Dimensions and Weight 30
220
250
215 125
145
6
185
Weight: approx. 5.8 kg
22 22
2-1-7 F300-A20__ Camera I/F Units Four types of Camera I/F Unit are available: Normal, Normal/simultaneously, Shutter, and Shutter/simultaneously.
Camera I/F Unit Models Unit Camera I/F Unit
Input
Model
Normal
F300-A20
Normal, simultaneously
F300-A20S
Shutter
F300-A20R
Shutter, simultaneously
F300-A20RS
Connectable cameras F300-S CCD Video Camera
Number of cameras Up to two cameras per Camera I/F Unit.
CCD Shutter Video Camera PJLG-55-Z
Note Select the external synchronization and non-interlace scanning methods of the CCD Shutter Video Camera by referring to the instruction sheet provided with the CCD Shutter Video Camera.
18
Page 24
Section 2-1
Required Units Components
The following illustration shows the essential components of the F300-A20__ Camera I/F Units.
Operation indicators CAMERA 0 (orange): Lit when camera is connected to camera connector #0 CAMERA 1 (orange): Lit when camera is connected to camera connector #1
Camera connector #0 Camera connector #1
Specifications General Specifications Ambient operating temperature
0%C to 50%C
Operating humidity
35% to 85% RH (no condensation)
Operating environment
No corrosive gases
Storage temperature
–25%C to 65%C
Enclosure rating
IP20 (in-panel)
Performance Specifications Item
F300-A20
F300-A20S
F300-A20R
F300-A20RS
Input
Normal
Normal/simultaneously
Shutter
Shutter/simultaneously
No. of connectable cameras
2 max
Connectable cameras
F300-S
PJLG-55-Z
Sync signal output
HD, VD both dependent on camera bus sync signal
HD: 15.734 kHz
Output amplitude
4 Vp-p, 1-kW negative pulse
4 Vp-p, 75-W negative pulse
Output pulse width
HD, VD both dependent on camera bus synchronous signal.
HD: 6.27 ms
Camera power output
12 V, 0.8 A (for 2 cameras)
12 V, 0.8 A (for 2 cameras) –12 V, 0.8 A (for 2 cameras)
Cable length
5 m (standard)
Weight
Approx. 400 g
Frequency
Approx. 550 g
VD: 59.94 Hz
VD: 9 H
Approx. 400 g
Approx. 550 g
19
Page 25
Section 2-1
Required Units Dimensions and Weight
The following diagram provides the external dimensions and weight of the F300-A20__ Camera I/F Units. Unless otherwise noted, values are in millimeters (mm). 34.6
133.5
14
250
Front cover
Base Unit
2-1-8 F300-S Camera The following illustration shows the essential components of the F300-S Camera.
Components AGC switch GAIN trimmer
SHT switch
F300-S Tripod attachment
GAIN trimmer
For the image amplifier. Do not adjust this trimmer.
AGC switch
Turns AGC on and off. Leave this switch off.
SHT switch
Turns the electronic shutter on and off. Leave this switch off.
20
Page 26
Section 2-1
Required Units Specifications General Specifications Power
12 VDC +10%
Ambient operating temperature
0%C to 50%C
Operating humidity
30% to 70%
TV system
Conforms to RS-170
Picture element
Interline CCD
Effective pixels
768 * 493 (H*V)
Scanned area
8.6 x 6.6 mm (equivalent to 2/3 inch)
Number of scan lines
525 lines
Scan method
2:1 interlace
Synchronization
Internal/external sync (automatically switchable)
Scan frequency
Horizontal: 15.734 kHz; Vertical: 59.94 Hz
Aspect ratio
4:3
Object illumination
Standard: 200 lux; F4 (3,200%K); AGC: ON; γ = 1.0 Minimum: 0.5 lux; F1.4; GAIN: MAX; γ = 0.45
Image output
VS: 1.0 Vp-p/75 W
Resolution
Horizontal: 570 lines; Vertical: 350 lines
S/N ratio
50 dBp-p/rms (AGC: OFF γ = 1.0)
AGC
Output level within +2dB for rated level fluctuations of +12 dB. Switchable ON/OFF with selector on panel. OFF on delivery.
Electronic shutter
1/1,000 s fixed. Switchable ON/OFF with selector on panel. OFF on delivery.
Lens mounting
C mount
Note Use the F300-S Camera with the electronic shutter and AGC set to OFF.
Dimensions and Weight The following diagram provides the external dimensions and weight of the F300-S Camera. Unless otherwise noted, values are in millimeters (mm).
98
44
29
35 10
45 22.75
1/4-20UNC, 6 mm deep
10
Weight: approx. 200 g
25 Two, M5 holes, 6 mm deep
21
Page 27
Section 2-2
Expansion Units
2-2
Expansion Units
2-2-1 F300-FS Strobe I/F Unit The following illustration shows the essential components of the F300-FS Strobe I/F Unit.
Components Strobe operation indicators (orange): Light when strobes 0 to 3 flash
Strobe connector Channel 0 Channel 1 Channel 2 Channel 3
Specifications General Specifications Ambient operating temperature
0%C to 50%C
Operating humidity
35% to 85% RH (no condensation)
Operating environment
No corrosive gases
Storage temperature
–25%C to 65%C
Enclosure rating
IP20 (in-panel)
Performance Specifications
22
Strobe connections
4 max.
Strobe trigger output
20 mA max. per Unit, photocoupler output
Strobe flash error input
Photocoupler input Input ON current: 3 mA min. Input OFF current: 1.5 mA max.
Page 28
Section 2-2
Expansion Units Dimensions and Weight
The following diagram provides the external dimensions and weight of the F300-FS Strobe I/F Unit. Unless otherwise noted, values are in millimeters (mm).
34.6
133.5
14
250
Front cover
Base Unit
Weight: approx. 400 g
2-2-2 F300-L100EV2 OVL Unit The OVL Unit extends the capabilities of the F300 to allow it to be operated using OVL (OMRON Vision Language). OVL was developed specifically for optical recognition and image measurement to permit more sophisticated measurements with a BASIC-like language. The OVL Unit’s keyboard also allows data input and system operation from the Menu mode in the same fashion as is possible from the Console.
Component
Keyboard connected indicator (green) Lit when the keyboard is connected.
Keyboard connector
23
Page 29
Section 2-2
Expansion Units Specifications General Specifications Ambient operating temperature
0%C to 50%C
Operating humidity
35% to 85% (no condensation)
Operating environment
No corrosive gases
Storage temperature
–25%C to 65%C
Enclosure rating
IP20 (in-panel)
Dimensions and Weight The following diagram provides the external dimensions and weight of the F300-L100E OVL Unit. Unless otherwise noted, values are in millimeters (mm). 34.6
133.5
14
250
Front cover
Weight: approx. 400 g
24
Base Unit
Page 30
Section 2-2
Expansion Units
2-2-3 F300-D Terminal Block Unit The F300-D Terminal Block Unit is connected to a programmable controller or other devices to input measurement commands and output measurement results. The following illustration shows the essential components of the F300-D Terminal Block Unit.
Components Input indicators (orange) Output indicators (orange)
I/O terminals
Specifications General Specifications Ambient operating temperature
0%C to 50%C
Operating humidity
35% to 85% RH (no condensation)
Operating environment
No corrosive gases
Storage temperature
–25%C to 65%C
Enclosure rating
IP20 (in-panel)
25