The text of a manual · part 7 of 7
F300 Visual Inspection System Specifications and Installation Manual, pages 61 to 65
Pages 61 to 65 of 65
The original document is the PDF (574 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron F300-A20, Omron F300-C10EV2, Omron F300-D, Omron F300-E, Omron F300-FM, Omron F300-FS and Omron F300-P
Page 61
Section 4-2
Maintenance
4-2-1 Back-up Battery Replacement 1, 2, 3...
1. Turn off the F300 System power. If the F300 System is already off, turn it on for 10 seconds then turn it off again. 2. Insert a small flat-blade screwdriver into the cut-out at the top of the battery cover and gently remove the cover.
3. Detach the battery connector. Cut the battery retaining band with nippers and pull the battery from the connector. 4. Secure the new battery to the cover with the retaining band supplied and attach the battery connector.
5. Return the battery cover to its original position. Note
1. Replace the battery within 5 minutes to prevent loss of the memory contents. If replacement will take more than 5 minutes, transfer the scene, system, and shading master data to a memory card or a computer connected to the RS-232C port before replacing the battery. 2. To prevent damage to or leakage from the battery, do not short, recharge, disassemble, or heat the battery.
57
Page 62
Section 4-3
Troubleshooting
4-2-2 Replacing the Fuse 1, 2, 3...
1. Turn off the F300 System. 2. Loosen and remove the fuse holder cap with a flat-blade screwdriver. Pull out the cap and remove the fuse located inside.
Fuse Fuse holder cap Flat-blade screwdriver
3. Insert a new fuse and replace the cap in its original position. Fuse Specifications
4-3
AC 100
125 V, 6.3 A, MF51NM, 5.2 dia. x 20 mm
AC 200
250 V, 3.15 A, MF51NM, 5.2 dia. x 20 mm
Troubleshooting
Troubleshooting Table Symptom
Cause
POWER indicator does not light
Broken power cable; circuit breaker tripped; loose terminal
Replace fuse.
Blown fuse
Set correctly.
Incorrect setting of voltage selector bar
Set bar correctly.
RUN indicator does not light
Measurement conditions not set
Correctly set measurement conditions.
ERROR indicator does not light
Defective IMP Unit
Contact Service Center
No image on screen
Incorrect connection of camera or video monitor
Check connector contact and cable conductivity.
Incorrect camera number setting
Correctly set camera number.
Defective connector contact; broken cable
Check connector contact and cable conductivity.
No input from Console or keyboard
58
Remedy
Page 63
Index B-C back-up battery, replacement, 57 Base Unit, 41 Camera, specifications, 21 Camera I/F Units models, 18 specifications, 19 camera lenses, types, 34 CCTV lens, 34 magnifying lens, 34 CCTV lens field-of-vision, 35 mounting distance, 35 components Expansion Units, 4 Dummy Unit, 5 I/O Unit, 4 OVL Unit, 5 Strobe I/F Unit, 5 required Units, 2 Base Unit, 2 Camera I/F Unit, 4 Console, 3 IMP Unit, 3 MMI Unit, 3 Power Supply Unit, 2 Video Monitor, 3 connections Camera I/F Units, 51 MMI Unit, 49 OVL Units, 52 Parallel I/O Unit, 54 RS-232C I/F Unit, 54 Strobe I/F Unit, 53 Console, specifications, 16
D-F Dummy Unit, specifications, 33 installation, 40 Base Unit, 41 location, 40 mounting, 42 See also mounting noise, 40 precautions, 41 temperature, 40
L lenses CCTV Lens field-of-vision, 35 mounting distance, 35 Extension Tubes, 36 Magnification Lens field-of-vision, 36 working distance, 36 Teleconverter, 36
M Magnification Lens field-of-vision, 36 working distance, 36 maintenance, 56 MMI Unit, specifications, 15 mounting positions, 42 procedure, 44
O-P OVL Unit, specifications, 24 Parallel I/O Unit, description and dimensions, 28, 29 terminal allocations, 30
IMP Unit, performance specifications, 14
Power Supply Unit, 44, 47 dimensions and weight, 13 general specifications, 12 grounding, 46 I/O wiring, 47 connecting cables, 49 See also connections performance specifications, 13 wiring, 45 inspection, 56 precautions, 41
Expansion Units, description and dimensions, 22 fuse, replacement, 58
I
59
Page 64
Index
R-S
U-V
Terminal Block Unit, specifications, 25, 26
Units description and dimensions, 10 Base Unit, 10, 11 mounting hole dimensions, 11 Camera, 20, 21 Camera I/F Unit, 18, 19, 20 camera lenses, 34, 36 Console, 16, 17 Dummy Unit, 33, 34 IMP Unit, 14 MMI Unit, 15 OVL Unit, 23, 24 Parallel I/O Unit, 28, 31 Power Supply Unit, 12 RS-232C I/F Unit, 31, 33 Strobe I/F Unit, 22, 23 Terminal Block Unit, 25, 27, 28 Video Monitor, 17, 18 Expansion Units, 22 mounting, 42 See also mounting troubleshooting, 58
Video Monitor, specifications, 17
RS-232C I/F Unit pin allocations, 32 specifications, 32 Strobe I/F Unit, specifications, 22 strobes, compatible units, 5 system basic configuration, 6 components. See components expanded configuration, 7
T Teleconverter, 36
60
Page 65
Revision History A manual revision code appears as a suffix to the catalog number on the front cover of the manual.
Cat. No. Z90-E1-2A Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code
Date
1
September 1992
2
March 1993
Revised content Original production Pages 2, 12: F300-PE model number was added to the Power Supply Unit. Additional information was included with a corresponding voltage correction/addition. Pages 3, 6, and 7: Model number and voltage clarifications were made to the Video Monitor. Page 4: A model number clarification was made to the RS-232C I/F Unit illustration. Page 5: A minor model number clarification was made to the strobe cable. Page 12: Factory-set voltage setting has been added to the table. Page 17: 2-1-6 F300-M09 Video Monitor section was added. Changes to the connectable camera model numbers were made to the table. Page 18: Changes to the connectable camera model numbers were made to the table. Page 26: Pin number sequences in the illustration have been corrected. Page 30: The Unit dimension 69.5 was corrected to 69.6 in the illustration. Page 32: Connections were changed for the 25-pin cable connection illustration. Pages 42, 43: F300-PE model number was added to the Power Supply Unit. Page 47: “PC” changed to “PLC” in the top illustration.
2A
March 1994
Page v: The Programmable Controller abbreviation “PC” has been changed to “PLC.” Pages 3, 14, 44, 45: IMP Unit model number changed. Page 4: Camera and cable model numbers have been changed or added, and the text has been changed accordingly. Pages 5 to 7: Model numbers changed or corrected. Page 18: Note added. Page 20: F300-S Camera illustration has been corrected. Page 21: TV system and synchronization information corrected. Note added. Dimensions of the F300-S Camera corrected. Pages 23, 45, 54: OVL Unit model number changed. Page 26: Minor corrections to the internal circuit illustration in input specifications. Page 29: Minor corrections to the internal circuit illustration in input and output specifications. ON residual voltage and OFF leak current information corrected. Page 31: Dimension of the F300-DC Parallel I/O Unit corrected. Page 32: Pin no. 8 in the table deleted. Page 33: Corrections were made to the connection diagrams. Note added. Page 34: Table at the bottom of the page corrected. Pages 35, 36: 2-3-2 CCTV Lens changed to 2-3-2 CCTV Lens, Field of Vision and Mounting Distance and its contents have been completely changed. Page 37: 2-3-3 Magnification Lens changed to 2-3-3 Magnification Lens, Field of Vision and Mounting Distance and the table has been changed. Page 38: 2-3-6 Optional Light Sources has been deleted. Page 45: Note added. Page 53: CCD Video Shutter Camera model numbers changed. Page 58: Fluctuation ranges in note 1 corrected.
61