Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Switch Mode Power Supply S82J (10/25/50/100/150/300/600-W Models)

Spec sheet · Omron

Switch Mode Power Supply S82J (10/25/50/100/150/300/600-W Models)

Spec sheet20 pagesPDF 2.3 MB

Datasheet for the OMRON S82J switch mode power supplies, 10 W to 600 W, including the S82J-02505 (5 V, 5 A) and S82J-10024 (24 V, 4.5 A).

Download the PDF2.3 MB

Covers · 2 models

The models it covers

Summary

What is in it

OMRON datasheet for the S82J family of switch mode power supplies from 10 W to 600 W with 5, 12, 15 or 24 V outputs. It explains the model number legend, lists open-frame, covered, front-mount and DIN rail models, and gives ratings and characteristics, safety approvals, block diagrams, terminal nomenclature, derating curves, overload, overvoltage and overheat protection behavior, and dimension drawings for each power rating.

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Omron datasheet for the S82J series of switch mode power supplies in 10, 25, 50, 100, 150, 300 and 600 W ratings. It lists every model number with its output, the ratings, block diagrams, protection functions, dimensions, mounting brackets and DIN rail bases, plus series and parallel wiring rules. The site files it under the S82J-02505 and S82J-10024 models.

Product
Omron S82J switch mode power supply series, 10 W to 600 W p. 1
S82J-02505 output
S82J-02505: 5 V, 5 A, 25 W p. 1, 2
S82J-10024 output
S82J-10024: 24 V, 4.5 A, 100 W p. 1, 2
S82J-02505 input
S82J-02505: 100 to 240 VAC (85 to 264 VAC), or 110 to 170 VDC p. 1, 2, 4
Number suffixes
A: open-frame, front terminals; D: covered, front terminals; a further D: DIN rail mounting bracket p. 1, 2, 3
Voltage adjustment
±10% with the V.ADJ adjuster p. 4, 8
Ripple, hold time
Ripple 2% (p-p) max.; hold time 20 ms min. p. 4
Overload protection
Trips above 105% to 160% of rated output current; clears automatically p. 4, 10
Overvoltage protection
S82J-10024: output shuts off at about 120% of rated voltage; reset by switching off for at least one minute p. 6, 10
Internal fuse
S82J-02505 (25 W): 2 A; S82J-10024: 5 A; on the (L) side, not user replaceable p. 1, 2, 5, 6, 8
Terminals
Five M3.5 screw terminals (+V, −V, PE, AC L, AC N), tightened to 0.74 N·m p. 11, 12, 18
DIN rail base
S82J-02505 (25 W): S82Y-03N; S82J-10024 (100 W): S82Y-10N; ordered separately p. 1, 2, 17
Front bracket
S82J-10024A and S82J-10024D: S82Y-J10F, ordered separately p. 3, 17
Environment
Storage −25 to 65°C; operating humidity 25% to 85%; operating temperature per derating curve p. 4

What this sheet walks you through

  • Reading the model number legend and model lists p. 1, 2, 3
  • Terminals, indicators and the voltage adjuster p. 8
  • Derating the load for ambient temperature p. 9
  • How the overload, overvoltage and overheat protection work and reset p. 10
  • Dimensions and mounting hole layouts p. 11, 12, 13, 14, 15, 16
  • Fitting a DIN rail mounting bracket and rail p. 17
  • Mounting methods, grounding and terminal screw torque p. 18
  • Switching the 300 W and 600 W models between 100 and 200 V input p. 19
  • Wiring supplies in series or parallel p. 19
  • Replacing the fan with the S82Y-JFAN fan set p. 3, 19

Good to know

  • Only the 300 W and 600 W models may be run in parallel. p. 19
  • Series operation is limited to two supplies, and only for the models the datasheet lists. p. 19
  • Do not power the supply from an inverter output. p. 5
  • A load with a built-in DC-DC converter may trip the overload protection at startup. p. 5, 10
  • Models with a 100 to 240 V free input draw more inrush energy, so the breaker must be matched to it. p. 10

Questions this sheet answers

What is the output of the Omron S82J-02505?

It gives 5 V at 5 A, a 25 W rating. p. 1, 2

Which DIN rail base fits the S82J-10024?

The S82Y-10N quick-mounting base, listed for the 100 W and 150 W models and ordered separately. p. 2, 17

Can I replace the fuse in an S82J power supply?

No. The fuse is on the (L) side and is not user replaceable. p. 8

Can two S82J-10024 supplies be wired in series?

Yes, up to two; the datasheet recommends diodes across the outputs because a shorted load can cause a reverse voltage. p. 19

What torque do the S82J terminal screws take?

0.74 N·m on the 10, 25, 50 and 100 W (24 V output) models, and 1.08 N·m on the 100 W (5, 12, 15 V), 150, 300 and 600 W models. p. 18

The whole text · 2 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20

The file

Revision and size

RevisionCSM_S82J_DS_E_3_1
PublisherOMRON Corporation
Pages20
PDF2.3 MB
TextText from the PDF itself.

The first pages · 4 of 20

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 20
Page 2
Page 2of 20
Page 3
Page 3of 20
Page 4
Page 4of 20

More documents · 1

For the same models