For the Omron S82J-02505 and Omron S82J-10024

Page 11

S82J

Dimensions Note: All units are in millimeters unless otherwise indicated. Open-frame type and covered type have the same dimensions.

■ Front-mounting Bracket Models S82J-010@@@ (10 W)

Mounting Holes (Surface Screw Mounting) 12 max.

90±1

Side Mounting 3.5

9.5

Output indicator (Green) Output voltage adjuster (V. ADJ)

Five, M3.5

+V DC output terminal −V Protective earthing terminal PE AC (L) Input terminal AC (N)

8.2

Two, M3 +V −V

97±1 65±0.5

65±0.5

AC AC

3.5 dia.

82±0.5

Nameplate 5

82±0.5

6.5 3.5 dia.

78±0.5

5

Bottom Mounting Two, M3

3.5

Two, M3 17.5

28 35±

1

78±0.5

50±0.5

15

Mounting Holes (Surface Screw Mounting)

S82J-025@@@ (25 W) 124±1

12 max.

9.5 8.2

Two, M3 +V

97±1

−V

65±0.5 AC AC

+V −V Protective earthing terminal PE AC (L) Input terminal AC (N) DC output terminal

Five, M3.5

Side Mounting

3.5

Output indicator (Green) Output voltage adjuster (V. ADJ)

65±0.5 3.5 dia.

Nameplate

116±0.5 5

116±0.5

6.5

112±0.5

6

Bottom Mounting

3.5

3.5 dia.

Two, M3 Three, M3 17.5

28

40±1

112±0.5

83±0.5

21.5

S82J-050@@@ (50 W)

9.5 8.2

3.5

Two, M3 97±1

−V

65±0.5 AC AC

+V −V Protective earthing terminal PE AC (L) Input terminal AC (N)

+V

Nameplate

Side Mounting

Output indicator (Green) Output voltage adjuster (V. ADJ) DC output terminal

Five, M3.5

Mounting Holes (Surface Screw Mounting)

161±1

12 max.

65±0.5 3.5 dia.

153±0.5 5

153±0.5

6.5

150.5±0.5

3.5 dia.

7

20±0.5

Bottom Mounting

3.5

Two, M3 20

28

Three, M3 10

22

40±1

150.5±0.5

127±0.5

11

Page 12

S82J S82J-10024@ (100 W, 24-V Output)

Mounting Holes (Surface Screw Mounting) Side Mounting

170±1

12 max.

4.5

Two, M4

Output indicator (Green) Output voltage adjuster (V. ADJ)

9.5 8.2

+V DC output terminal −V Protective earthing terminal PE AC (L) Input terminal AC (N)

Five, M3.5

97±1 65±0.5

65±0.5

4.5 dia.

162±0.5

Nameplate 5

162±0.5

6.5

160±0.5

7

Bottom Mounting Two, M4

4.5

4.5 dia.

Three, M4

25±0.5

50±

1

28±0.5

27.5 100±0.5

15

160±0.5

15

S82J-100@@@ (100 W, 5-/12-/15-V Output) S82J-15024@ (150 W)

Mounting Holes (Surface Screw Mounting) 198 (see note)

Side Mounting

188 4 max.

Two, M4 4.5 89±0.5 97

8.1

82±0.8

9.5

180±0.5

Eight, M4

180±0.5

7±0.3 4.5 dia.

3±0.25

Bottom Mounting

Mounting holes (on both sides) 4.5 dia.

Two, M4 3±0.25

178±0.5

4.5

27.5±0.3

Three, M4 (depth: 6 max.)

100±0.5

25±0.5 50 35±0.3 15

178±0.5

55±0.3

S82J-30024@ (300 W) Nine, M4 terminal screws

4

(19)

181±1

DC ON

Eight, M4 holes (depth: 8 max. on both sides)

INPUT 50/60Hz AC100-120V 8A AC200-230V 4A

10

+V

N

OUTPUT

8.6

Side Mounting

L

92±1

DC24V 14A

Side

Mounting Holes (Surface Screw Mounting)

V. ADJ

POWER SUPPLY

-V

50±0.5

Four, 4.5 dia.

VOLTAGE SELECT SHORT 100-120V OPEN 200-230V

SHORT BAR OPERATION

ALM

21

OMRON Corporation MADE IN JAPAN PARALLEL

SINGLE

50±0.5 120±1

19

150±0.5

Four, M4 holes (depth: 8 max.)

150±0.5

10

Bottom Mounting Four, 4.5 dia. 100±0.5

100±0.5

19

150±0.5

150±0.5

12

Page 13

S82J S82J-60024@ (600 W) Eight, M4 holes (depth: 8 max. on both sides)

Mounting Holes (Surface Screw Mounting) Side Mounting Four, 4.5 dia.

50±0.5

Four, M4 holes (depth: 8 max. on one side) Four, M4 holes (depth: 8 max.)

150±0.5

Bottom Mounting

Nine, M4 terminal screws

Four, 4.5 dia.

100±0.5

150±0.5

■ Dimensions with Mounting Brackets Note: Panel mounting screw are not supplied.

Front-mounting Bracket (Supplied) For 10-/25-/50-/100 (24 V)-W Models 11

1.5

Mounting Holes

Attach the mounting bracket to the panel and loosely tighten the two screws. Insert the projected parts of the bracket (b) to the square holes of the power supply (a). Then securely tighten the screws.

4.6 15±0.2

9

Two, M3

60 Two, 3.5 dia.

60

Using the Mounting Bracket

74

4.6 11

20

20

5

31.5

(b) 4.7

15 t=1.0

(a) Power supply unit

20.5

Mounting bracket

Material: Stainless steel

(b)

(a)

Note: The mounting screws are not provided.

For 100- (5, 12, 15 V) and 150-W Models

Dimensions with Mounting Brackets

Attaching the Mounting Brackets

6.5 Mounting bracket 11 5 dia.

23.5

1.5

38

120 max. 110±0.5 t=0.8

Note: The brackets are for front-mounting. 30±0.5

Two, 5 dia.

13

Page 14

S82J 300-W and 600-W Models Note: A mounting bracket is included with the S82J-30024 and S82J-60024, but not with the S82J-30024N and S82J-60024N.

For 300-W Models (S82Y-J30F)

Dimensions with Mounting Brackets For 300-W Models

10 dia. R2.5

15 7.5

Attaching the Mounting Brackets For 300-W Models

30

7.5 145±0.5 160 145±0.5

Four, 5 dia. 92 t=1.6

36.4±0.2 32

Note: Mounting Brackets are provided in a set, one for the right side and one for the left side.

48

90±0.5

Note: To provide ventilation space, the body will shift forward by 21.6 mm from the mounting surface.

Four, M4

Dimensions with Mounting Brackets For 600-W Models

Attaching the Mounting Brackets For 600-W Models

145±0.5 L

140±0.5

N

Four, M4

Note: To provide ventilation space, the body will shift forward by 23.6 mm from the mounting surface.

14

Page 15

S82J ■ DIN Rail Mounting Bracket Models Note: All units are in millimeters unless otherwise indicated. The open-frame type and connected type have the same dimensions.

S82J-010@@@D (10 W)

7 max.

12 max.

Five, M3.5

(Sliding: 9 max.)

S82J-025@@@D (25 W)

7 max.

12 max.

Five, M3.5

(Sliding: 9 max.)

S82J-050@@@D (50 W)

7 max.

12 max.

Five, M3.5

(Sliding: 9 max.)

S82J-10024@D (100 W, 24-V Output)

7 max.

12 max.

Five, M3.5

(Sliding: 9 max.)

15

Page 16

S82J S82J-100@@@D (100 W, 5-/12-/15-V Output) S82J-15024@D (150 W) 7 max. Eight, M4

4 max.

(Sliding: 9 max.)

16

Page 17

S82J ■ Front-mounting Bracket for S82J-10024A/-10024D Power Supply (Order Separately) (Unit: mm) Product Front-mounting Bracket

Model number

Dimensions

S82Y-J10F

Mounting hole dimensions Three, 4.5-dia. holes Three, M4

40

50

20

50

15

15 t = 1.6 180

Note: This Front-mounting Bracket cannot be used with S82J 100-W (5, 12, or 15-V) or 150-W models.

■ DIN Rail Mounting Bracket (Order Separately) Can be used with 10-W to 150-W Front-mounting bracket models. If DIN Rail mounting is necessary, use a DIN Rail Mounting Bracket. Model S82J

Power Rating

Applicable Quickmounting Base

10 W

S82Y-01N

25 W

S82Y-03N

50 W

S82Y-05N

100 W, 150 W

S82Y-10N

Main unit

Size

Quick-mounting base

Model PFP-100N (or PFP-100N2)

47

104

Mounting rail

L1

L2 (See note.)

S82Y-01N

113

114.8

S82Y-03N

143

144.8

S82Y-05N

163

164.8

S82Y-10N

185

186.8

Two, 4.5-dia. holes L1 L2

47 58

Note: The L2 dimension refers to using the PFP-100N on a DIN rail. When using the PFP-100NS, add 10.5 mm to L2.

4.9 (Sliding: 7 max.)

Panel thickness (t): 1.6 mm

■ DIN Rail (Order Separately) Note: All units are in millimeters unless otherwise indicated.

Mounting Rail (Material: Aluminum) PFP-100N PFP-50N

7.3±0.15 4.5 35±0.3

15

25

10

25

25

10

25

27±0.15

1

15(5) *

1,000 (500) *

*Values in parentheses are for the PFP-50N.

Mounting Rail (Material: Aluminum) 16

PFP-100N2 4.5 35±0.3 27

15

25

10

25

25 1,000

10

25

15

24

29.2

1

1.5

17

Page 18

S82J

Safety Precautions Refer to Safety Precautions for All Power Supplies.

100 (-5, -12, -15 V Output)/150-/300-/600-W Models

!CAUTION Minor electric shock, fire, or Product failure may occasionally occur. Do not disassemble, modify, or repair the Product or touch the interior of the Product. Minor burns may occasionally occur. Do not touch the Product while power is being supplied or immediately after power is turned OFF. Fire may occasionally occur. Tighten terminal screws to the specified torque 0.74 N·m for 10-, 25-, 50-, or 100-W models (24-V output); or 1.08 N·m for 100- (5-, 12-, or 15V output), 150-, 300-, or 600-W models.

The following 4 mounting methods are possible. (A) Side mounting (B) Bottom mounting (secured with screws from the inside of the Switching Power Supply) (except for 300- and 600-W models) (C) Bottom mounting (secured with screws from the back of the Switching Power Supply)

(B)

Minor injury due to electric shock may occasionally occur. Do not touch the terminals while power is being supplied. Minor electric shock, fire, or Product failure may occasionally occur. Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product.

(A)

■ Precautions for Safe Use Mounting

(C)

To improve and maintain the reliability of the Power Supply over a long period of time, adequate consideration must be given to heat radiation.

(D) Front mounting Front mounting is possible with the mounting brackets provided. Refer to Dimensions on page 11.

The Power Supply is designed to radiate heat by means of natural air-flow. Therefore, mount the Power Supply so that air flow takes place around the Power Supply. When mounting the Power Supply, mounting it to a metal plate is recommended. When mounting two or more Power Supplies side-by-side, allow at least 20 mm spacing between them, as shown in the following illustration. Forced air-cooling is recommended. Mounting brackets (provided) Metal plate

Wiring Air

Connect the ground completely. Electric shock or malfunction may occur if the ground is not connected completely. 20 mm min.

Metal plate

Tighten terminal screws to the following specified torque. Capacity

Terminal screws

Mounting Methods

10-, 25-, 50-, or 100-W (24 V)

The following mounting methods are available.

100-W (5-, 12-, or 15-V), 150-, 300-, 600-W M4

10-/25-/50-/100 (24-V Output)-W Models (A) Side mounting (B) Bottom mounting (C) Front mounting (see Accessories)

M3.5

Torque 0.74 N·m 1.08 N·m

Do not apply more than 75-N force to the terminal block when tightening it.

Note: Refer to the section on the Mounting Bracket.

(B)

(A)

18

Page 19

S82J Switching the AC Input Voltage between 100 and 200 V (300- and 600-W Models)

Parallel Operation

The input voltage can be switched between 100 and 200 V by shorting or opening the input voltage selection terminals. Set the required voltage as shown below. (The voltage is factory-set to 200 V.)

Set the parallel operation selector to PARALLEL if the Units are in parallel operation and make sure that the thickness and the length of all wires connected to the load are the same to ensure that the wires will have no voltage drop differences. If you adjust the voltage using the output voltage adjuster (V.ADJ), adjust the output voltage from both Power Supplies.

200-V input

100-V input L

L

N

N

VOLTAGE SELECT SHORT 100-120V OPEN 200-230V

VOLTAGE SELECT SHORT 100-120V OPEN 200-230V

SHORT BAR

SHORT BAR

OMRON Corporation MADE IN JAPAN

OMRON Corporation MADE IN JAPAN

Short with the short bar.

Only 300- and 600-W models can be in parallel operation. Do not operate any other models in parallel. The output of the models in parallel operation is a maximum of 80% of the rated output.

Fan Replacement The service life of the fan is approximately 50,000 hours (at 25°C). The service life varies, however, depending on the ambient temperature or other surrounding environmental conditions such as dust. As a preventive maintenance measure, replace the fan within approx. two years if it is used at an ambient temperature of 40°C. Fans are available as replacements.

Remove the short bar and leave the terminals open.

Note: A 300-W Model is shown above.

Series Operation Only models with power ratings of 50, 100 (-5, -12, -15, 24-output), 150, 300, or 600-W allow series operation. +V INPUT

D1

V1

VL

Load

−V

+V INPUT

D2 −V

Model S82J

Output capacity

V2 VL= V1 + V2

Rated output voltage

100 W

5, 12, 15, 24 VDC

50, 150, 300, 600 W

24 VDC

Model: S82Y-JFAN Fan Set: Fan (above), four M4 x 35 sems screws, instruction sheet, and packing case Replace the fan as shown in the following illustration.

Up to two of the above Power Supplies can be used in series operation. Models other than the above Power Supplies cannot be used in series operation. If series operation is attempted for other models, the output from one of the Power Supplies may not come ON when the AC input is applied. If that occurs and the Power Supplies are left in that state, internal circuits may be damaged. Although Power Supplies having different output capacities and different output voltages can be connected in series, the current flowing through the load must not exceed the smaller rated output current. With the S82J-05024@@ or S82J-10024@@, if the load is shorted a reverse voltage may result in the Power Supply causing deterioration and damage. It is recommended that diodes are connected as shown in the previous diagram (D1, D2). Type Dielectric strength (VRRM) Forward current (IF)

Schottky barrier diode Twice the rated output voltage or above Twice the rated output current or above

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice.

19

Page 20

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.

Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.

DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.

ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.

2011.1 In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company http://www.ia.omron.com/

(c)Copyright OMRON Corporation 2011 All Right Reserved.