Page 9
S82K ■ Inrush Current, Startup Time, Hold Time Input OFF
Input ON AC input voltage
Inrush current on input application AC input current 90%
96.5%
Output voltage Startup time: 100 to 1000 ms max. depending on the model.
Hold time (20 ms min.)
■ Reference Value Item
Value
Definition
Reliability (MTBF)
135,000 hrs min.
MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent a life of the product.
Life expectancy
8 yrs. min.
The life expectancy indicates average operating hours under the ambient temperature of 40°C and a load rate of 50%. Normally this is determined by the life expectancy of the builtin aluminum electrolytic capacitor.
9
Page 10
S82K
Dimensions Note: All units are in millimeters unless otherwise indicated.
Mounting Brackets (Supplied) Used when not mounting the Power Supply directly on the DIN rail.
S82K-003@@ (3 W) S82K-007@@ (7.5 W)
Two, 4.5±0.1 dia.
25±0.15
35±0.15
27±0.1 37.5±0.1
Mounting Holes Attached Mounting Bracket
M3.5 with square washer (Sliding: 7 max.)
M4 or 4.5-dia. hole
Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply.
S82K-015@@ (15 W)
45 9.8 8.3
7.5
Mounting Holes Two, M4 or 4.5-dia. mounting holes
75
45
58.1
35 60
91 4.6 (Sliding: 7 max.)
5
L
35
M3.5 with square washer
Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply.
10
Page 11
S82K S82K-030@@ (30 W) S82K-05024 (50 W) Four, 4.5 dia.
35
4 (Sliding: 7 max.)
M3.5 with square washer
Mounting Holes Four, M4 or 4.5-dia. mounting holes
60
L
Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply.
80
S82K-@09024 (90 W) S82K-@10024 (100 W) 145 135±0.2 9.8
75
Four, 4.5 dia.
8.3
7.5
45
58.1
35
60±0.2
91 4 (Sliding: 7 max.)
M3.5 with square washer
5
M3.5 terminal screw Short bar
Mounting Holes Four, M4 or 4.5-dia. mounting holes
60
L
Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply.
135
11
Page 12
S82K ■ DIN Rail (Order Separately) Mounting Rail (Material: Aluminum) PFP-100N/PFP-50N
PFP-100N2
16 7.3±0.15
4.5
4.5 35±0.3 15
25
25 10
25 1,000 (500) (See note.)
35±0.3 27
27±0.15 15
25 10
15 (5) (See note.)
25
1
25 10
25 1,000
25 15 10
24
29.2
1
1.5
Note: The values shown in parentheses are for the PFP-50N.
■ Noise Filter (Order Separately) S82Y-JF3-N for 3- to 50-W Models S82Y-JF6-N for 90- and 100-W Models 16 max.
A max. B±1
16 max.
Two, 4.8 dia. (Mounting holes)
D±1
4
39±0.5
Nameplate
47±1
4 6.5
C±0.5
6.5
Six, M4
12
Page 13
S82K
Safety Precautions Refer to Safety Precautions for All Power Supplies. To dismount the Power Supply, pull down portion (C) with a flat-blade screwdriver and pull out the Power Supply.
!CAUTION Minor electric shock, fire, or Product failure may occasionally occur. Do not disassemble, modify, or repair the Product or touch the interior of the Product. Minor burns may occasionally occur. Do not touch the Product while power is being supplied or immediately after power is turned OFF. Fire may occasionally occur. Tighten terminal screws to the specified torque of 0.98 N·m (M3.5).
(C)
Minor injury due to electric shock may occasionally occur. Do not touch the terminals while power is being supplied. Always close the terminal cover after wiring.
30 mm min.
Rail stopper
Minor electric shock, fire, or Product failure may occasionally occur. Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product.
Wiring
■ Precautions for Safe Use
Ensure that input and output terminals are wired correctly.
Mounting Take adequate measures to ensure proper heat dissipation to increase the long-term reliability of the product. The Power Supply is designed to radiate heat by means of natural air-flow. Therefore, mount the Power Supply so that air flow takes place around the Power Supply.
Do not apply more than 75-N force to the terminal block when tightening it.
Selection of 100 or 200 VAC Input Voltage (S82K-@09024/-@10024) Select a 100-V or 200-V input by shorting or opening the input voltage selector terminals, as shown in the following diagram. (The default setting is 200 V.)
100-V Input
Air Use the short bar to short-circuit terminals 7 and 8.
When mounting two or more Power Supplies side-by-side, allow at least 10 mm spacing between them, as shown in the following illustration. Forced air-cooling is recommended.
200-V Input
10 mm min.
Remove the short bar to open terminals 7 and 8.
Generating Output Voltage (±) An output of ± can be generated by using two Power Supplies as shown below, because the Power Supply produces a floating output. Short bar
To mount the Power Supply on a DIN rail, hook portion (A) of the Power Supply to the rail and press the Power Supply toward direction (B).
Correct +V INPUT −V
(A)
+V INPUT −V
(B)
When connecting the Power Supplies in series with an operation amplifier, connect diodes to the output terminals as shown by the dotted lines in the figure. No diodes are required with S82K-@09024 and S82K-@10024.
13
Page 14
S82K Series Operation
Parallel Operation
Two Power Supplies can be operated in series. Only 90-W/100-W models can be operated in series. Series operation, however, is not possible for the + outputs and – outputs of models with ± outputs.
S82K 100-W models can be operated in parallel. Perform parallel operation with power supplies satisfying the same model. Correct
Correct
100-W Models 90-, 100-W Models +V +V
INPUT −V
INPUT −V
+V +V
INPUT −V
INPUT −V
Note: When operating the S82K-P10024 in parallel operation, set the selector to “PARALLEL. In this case, the rated current per S82K-P10024 is 3.78 A.
Incorrect
3-, 7.5-, 15-, 30-, 50-W Models +V INPUT −V
Incorrect
3-, 7.5-, 15-, 30-, 50- and 90-W Models +V INPUT −V
+V INPUT −V
+V INPUT −V
Parallel Operation Precautions The length and thickness of each wire connected to the load must be the same so that there is no difference in voltage drop value between the load and the output terminals of each Power Supply. Adjust the output voltage of each Power Supply with output voltage adjuster (V. ADJ) so that there will be no difference in output voltage between each Power Supply.
Minimum Output Current (S82K-00727/S82K-00728) The minimum output current of the S82K-00727 and S82K-00728 is restricted by the output voltage and control method. Note: All the outputs of the S82K-00727 and S82K-00728 are controlled by the +V output. If the +V output current falls to more than 10% of the rated output, the –V output voltage may drop.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice.
14
Page 15
Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
2011.1 In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2011 All Right Reserved.