The text of a manual · part 1 of 2
ZEN Programmable Relays (New Product News), pages 1 to 7
Pages 1 to 7 of 8
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron ZEN-10C1AR-A-V1 /AC100
Page 1
New Product News
0-
2 New nt T poi ype
Sen N P N s sor rs m n te o u r o f c t s rs, Inpu me uction i t str a ny s m play in a ce is Twi and d
Note: Do not use this document to operate the Unit.
OMRON Corporation
Regional Headquarters
Industrial Automation Co mpany OMRON EUROPE B.V. Industrial Devices and Components Division H.Q. Industrial Control Components Department Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel:(81)75-344-7119 Fax: (81)75-344-7149
Authorized Distributor:
Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands Tel:(31)2356-81-300/Fax:(31)2356-81-388
OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel:(1)847-843-7900/Fax:(1)847-843-8568 OMRON A SIA PACIFIC PTE. LTD. 83 Clemenceau Avenue, #11-01, UE Square, 239920 Singapore Tel:(65)6835-3011/Fax:(65)6835-2711 OMRON CHINA CO. , LTD, BEIJING OFFICE Room 1028, Office Building, Beijing Capital Times Square, No. 88 West Chang'an Road, Beijing, 100031 China Tel: (86)10-8391-3005/Fax: (86)10-8391-3688 Note: Specifications subject to change without notice.
Cat. No. L102-E1-01 Printed in Japan 0503-5M
,
Page 2
Just a few examples of what the ZEN can do: Enormous added value in automating everyday facilities Fan and Pump Control reduced assembly or wiring? AC inputs, easier circuit design, or multiple-timer control? The OMRON ZEN gives you these, and more, to fill all your automation requirements. Increase system convenience and added value using the automation excellence provided by the ZEN.
Easier small-scale automatic control. That is what the ZEN from OMRON provides. The ZEN can be used almost as easily as wiring materials. The ZEN enables quick automation of small machines or facilities. Add to this the LCD screen and 8 buttons on the front panel for easy ladder program input. You want a more compact control panel or
Factories (Jigs, Operator Error Prevention, Small Equipment) Application of Bit Logic and Timer Functions
Coin-operated Car Wash
Example Program 00 I 0
H0
01 M0 02 M0
12 H 0
[ M0
I0
M3
I0
H1
[ H0
1st coin detected
03 H0 NC
04 H0
AC100-200V 100AR-A
05 M1 06 M1
I0
M4
I0
H2
[ M1 [ H1
2nd coin detected
Coin selector ZEN
Car wash operation
10 M2
I0
M5
[ H2
14 H 2 15 # 0
H0
H1
16
H1
H2
17
H2
18 M 3
[ M3 [ M4 [ M5 R#0
01
Parts s
Hold for 1st coin cleared Hold for 2nd coin cleared Hold for 3rd coin cleared Holding timer reset
M 2 Q0 upward differe T2
3rd coin detected on 07
The car wash operates for 3 minutes for one coin, 6 minutes for two coins, and 9 minutes for 3 coins.
Tool sensor
Screw tool Parts sensor (I
Holding Timer #0
Tool sensor (I Tool cylinder (air) (Q
If the part required for assembly does not pass through the sensor, the screw tool will not be supplied with air to prevent mistakes.
Additional process switch (I Work bit (M Work bit (M
Set to 3 min.
Application of Bit Logic and Timer Functions
Greenhouse Air Circulator Control
Parameter Settings
Example Program 00 I 0 Operates
Time Offset Startup Time Setting T0
SM0
01 I 1 Stops
M2 turns ON for 1 scan after Q0 turns ON.
06
Parameter Settings
Energy Conservation and Automation of Building Facilities Application of Bit Logic, Timer Functions, and Weekly Timers
Automatic Escalator
Parameter Settings
Example Program
RM0
NC
NC
02 M 0
AC100-200V 100AR-A
T1
03 04
ZEN er M0
11 H2
The ZEN can be used to change the operating time depending on the number of coins inserted. If a holding timer (#) is used with holding bits (H) in self-holding programming, the remaining time will not be reset even if there are unexpected power interruptions.
Ex
20 M 5
[ M2
09 M2
13 H 1
19 M 4
07 H1 08 H1
[ Q0 Car washer drive output T#0 Holding timer starts
Application of Bit Logic and Timer Functions
Preventing Assembly Omissions and Other Mistakes
Contactor Motor
Fan
T0
05
T2
06
T1
[ Q0
Fan 1 operates
TT0
Startup time offset time
[ Q1
Fan 2 operates
TT1
Operation time
TT2
Stop time
00 I 1 Operates
AC100-200V 100AR-A
SM0
01 I 2 Stops
Set to 30 s.
Sensor
02 @0
ZEN Escalator operates
RM0 M0
[ Q0
Escalator operates
TT0
OFF-delay timer starts Times for 3 minutes after detecting person.
03 @1
Time Offset Startup Time Setting T1
04 T 0
07
05 I 0 Person detected 06
When the operation switch is pressed, fan 1 starts and 30 seconds later fan 2 starts. The fans repeat a cycle of 1 hour operating, 1 hour 30 minutes stopped.
The ZEN can be used to circulate carbon dioxide or warm air. Two circulation fans can be operated at regular intervals. Startup current can also be reduced by staggering operation of the two fans.
Weekly Timer @0 (Mon to Fri: 7:00 to 10:00)
Weekly Timer @1 (Mon to Fri: 17:00 to 22:00)
Set to 1 h.
Time Offset Startup Time Setting T2
Set to 1 hour 30 min.
An escalator can operate continuously between specified days and times. It can also be set to conserve energy by operating outside those times only when a person approaches the escalator.
Two weekly timers are used to operate the escalator between 7:00 and 10:00 am and 5:00 and 10:00 pm on weekdays. Outside those times, the escalator uses the OFF-delay timer to operate for 3 minutes after a person has been detected.
OFF-delay Timer T0
Research and Development Devices
Testing Equipment
Application of Bit Logic, Timer Functions, and Counter Functions Parameter Settings
Example Program
Application of Bit Logic
Lighting Pattern Control
Example Program
T0, Output ON Time
NC
AC100-200V 100AR-A
SM0
Performing test
RC0
Counter reset
RM0
Performing test
00 I 0 All lights ON 01
Switch
ZEN
Testing equipment
TT0
ON time
TT1
OFF time
CC0
Counter
[ Q0
Output
SQ2 Group 3 lit
03 NC
04 I 1 Pattern 1
AC100-200V 100AR-A
T 1 OFF time
SQ1 Group 2 lit
02
Set to 2 minutes.
T1, Output OFF Time
05 06
Switch
ZEN
Light
07
SQ0 Group 1 lit
SQ3 Group 4 lit SQ0 Group 1 lit RQ1 Group 2 not lit SQ2 Group 3 lit RQ3 Group 4 not lit
08 I 2 Pattern 2 09 10 11 12 I 3 All lights OFF 13 14 15
SQ0
Group 1 lit
SQ1
Group 2 lit
RQ3
Group 3 not lit
RQ3
Group 4 not lit
RQ0
Group 1 not lit
RQ1
Group 2 not lit
RQ2
Group 3 not lit
RQ3
Group 4 not lit
Set to 3 minutes.
ON/OFF switching can be performed for durability and other tests in R&D.
2
When the operation switch is pressed, the device repeats a sequence of 2-minutes-ON, 3-minutes-OFF for a total of 100 times before automatically stopping.
C0, Number of Times Output Turns ON
Set to 100 times.
Set the required light patterns and change between patterns with the flick of a switch to save energy by improving lighting efficiency.
Switch 1 (I0) turned ON, all lights turn ON. Switch 2 (I1) turned ON, light groups 1 and 3 turn ON. Switch 3 (I2) turned ON, light groups 1 and 2 turn ON. Switch 4 (I3) turned ON, all lights turn OFF.
3
Page 3
The Main Features of the Lightweight and Easy-to-use ZEN Easy Programming* The LCD screen comes with 8 operation buttons on the front panel to enable programming in ladder view format. The LCD screen also has a backlight, making it easier to see when the ZEN is used in dark locations.
Flexible Expansion
Zen Provides a Broad Selection of 10-point to 20-point Models CPU Units with 10 I/O Points
Expansion I/O Units
• LCD Type (with liquid crystal display)
• LED Type (without liquid crystal display)
ZEN-10C1AR-A-V1 (AC type, relay outputs) ZEN-10C1DR-D-V1 (DC type, relay outputs) ZEN-10C1DT-D-V1 (DC type, transistor outputs)
ZEN-10C2AR-A-V1 (AC type, relay outputs) ZEN-10C2DR-D-V1 (DC type, relay outputs) ZEN-10C2DT-D-V1 (DC type, transistor outputs)
The ZEN can be used effectively for lighting and other applications requiring many output points. Expansion I/O Units can be added easily if there are not enough I/O points. The compact ZEN takes up little space.
*For LCD-type CPU Units only.
ZEN-8EAR (4 AC inputs, 4 relay outputs) ZEN-8EDR (4 DC inputs, 4 relay outputs) ZEN-8EDT (4 DC inputs, 4 transistor outputs) ZEN-4EA (4 AC inputs) ZEN-4ED (4 DC inputs) ZEN-4ER (4 relay outputs)
CPU Units with 20 I/O Points
Hold Functions for Peace of Mind The ZEN has holding timers and holding bits to give peace of mind against unexpected power failures. These functions hold the previous status so that operation can continue with the same status after power has been restored. You can also mount a Battery Unit (optional) to back up the calendar and clock functions for 10 years or more. Ladder programs and parameter settings can be backed up to the CPU Unit's internal EEPROM, ensuring no data will be lost even if a Battery Unit is not installed.
Memory Cassettes
• LCD Type (with liquid crystal display)
• LED Type (without liquid crystal display)
ZEN-20C1AR-A-V1 (AC type, relay outputs) ZEN-20C1DR-D-V1 (DC type, relay outputs) ZEN-20C1DT-D-V1 (DC type, transistor outputs)
ZEN-20C2AR-A-V1 (AC type, relay outputs) ZEN-20C2DR-D-V1 (DC type, relay outputs) ZEN-20C2DT-D-V1 (DC type, transistor outputs)
Optional Memory Cassettes have a wide range of uses programs can be easily saved or downloaded, or copied to other ZEN.
Operations Determined after Wiring Hardware relays or timers can normally be selected only after operations have been decided. The ZEN is different. You can wire the ZEN first and then carefully consider operating details later. This makes programming and maintenance after wiring a simple matter.
Many Other Functions Standard Functions on All CPU Units • Two types of power supply specifications: 100 to 240 VAC or 24 VDC • Input filters to prevent noise-related malfunctions • Analog inputs • Outputs have a large switching capacity (8 A at 250 VAC). • Up to 44 I/O points if Expansion I/O Units added. • Password protection. • Conforms to EC Directives. Scheduled for conformance to UL/CSA in the future. • Programming using ZEN Support Software on Windows 95, 98, 2000, ME, XP, or NT 4.0 Service Pack 3
Input from NPN- or PNP-output Sensors (DC power supply: V1 CPU Units)
Twice the Timers and Counters (V1 CPU Units Only)
10C1DR-D-V1
4
V1 Units
8 points
16 points
Holding timers (#)
4 points
8 points
Counters (C)
8 points
16 points
NPN output
Weekly timers (@)
8 points
16 points
PNP output
Calendar timers ( )
8 points
16 points
Displays (D)
8 points
16 points
Functions Unique to LCD-type CPU Units • Displays in 6 languages (Japanese, English, German, French, Spanish, and Italian) • Calendar and clock functions. • Display user-set messages or converted values.
Pre-V1 Units Timers (T)
V1 CPU Unit
5
Page 4
Programming Is Even Easier with ZEN Support Software
The More You Get to Know It, the Better It Is, The Amazing ZEN CPU Units and Expansion I/O Units Name
CPU Units
Type
Model number
LCD
ZEN-10C1AR-A-V1
LED
ZEN-10C2AR-A-V1
LCD
ZEN-10C1DR-D-V1
LED
ZEN-10C2DR-D-V1
LCD
ZEN-10C1DT-D-V1
LED
ZEN-10C2DT-D-V1
LCD
ZEN-20C1AR-A-V1
LED
ZEN-20C2AR-A-V1
LCD
ZEN-20C1DR-D-V1
LED
ZEN-20C2DR-D-V1
LCD
ZEN-20C1DT-D-V1
LED
ZEN-20C2DT-D-V1
Power supply voltage
No. of I/O points
ZEN-8EAR
100 to 240 VAC 10
24 VDC 24 VDC
100 to 240 VAC 20
24 VDC 24 VDC
8
ZEN-8EDR ZEN-8EDT
Expansion I/O Units
ZEN-4EA 4
ZEN-4ED
Inputs 6 6 6
12 12
Outputs
100 to 240 VAC 24 VDC
4 4
24 VDC
4
100 to 240 VAC
8 8
24 VDC
Calendar and clock
Analog input
Yes
Yes
No
Relays Relays Transistors
Relays Relays
12
24 VDC
8
Transistors
4
100 to 240 VAC
4
Relays
4
24 VDC
4
Relays
4
24 VDC
4
Transistors
4
100 to 240 VAC
4
24 VDC 4
Relays
ZEN-4ER
LCD and buttons No
No
No
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
No
No
No
No
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
No
No
Yes
Optional Units Name
Model number
Specifications
Connecting Cable
ZEN-ME01
ZEN-CIF01
Simulating Ladder Programs
ZEN ladder programs can be created with ease.
The simulation function makes it possible to check whether correct operation is performed without connecting to the ZEN.
Note: The Edit Input Dialog Box is displayed when an input bit is inserted. Timer, counter, and other parameter settings are also set in the Edit Input Dialog Box. They cannot be set in the Edit Output Dialog Box.
Note: The simulation function is supported by ZEN-SOFT01-V2 and later versions.
LED Type
Supported
Not supported
Transfer from Memory Cassette to ZEN
Supported
Supported (Automatic transfer when power turned ON)
Memory Cassette initialization
Supported
Not supported
Printing Ladder Programs
The operating status can be monitored from the Support Software by connecting to the ZEN using a Connecting Cable (ZEN-CIF01).
Ladder programs and I/O comments, as well as timer, counter and other parameter settings can be printed.
2-m RS-232C (9-pin D-sub connector)
Battery Unit
ZEN-BAT01
ZEN Support Software
ZEN-SOFT01-V3
System Configuration
LCD Type Transfer from ZEN to Memory Cassette EEPROM
Creating Ladder Programs
Monitoring Ladder Programs
Remarks Enables programs and parameter settings to be saved or copied to another ZEN (See note.)
Memory Cassette
ZEN Support Software Functions
10 year min. battery life (at 25˚C) Runs on Windows 95, 98, 2000, ME, XP, or NT 4.0.
The program and parameter settings are backed up in the CPU Unit's internal EEPROM and will not be lost. Use the Battery Unit to prevent loss of calendar/clock, holding bits, holding timer present values, counter present values, and other data when the power is turned OFF for an extended time (for 2 days or more at 25˚C). This data is otherwise backed up using RAM and a super-capacitor. Specifically designed for the ZEN (CD-ROM).
CPU Unit
Expansion I/O Unit
NC
Battery Unit AC100-200V 100AR-A-V1
The Support Software can also be used to save files and edit comments.
ZEN Support Software and CPU Unit Versions Connecting Cable
• Up to 3 Expansion I/O Units can be connected, regardless of the I/O he Connecting Cable and Memory assette cannot be connected to the ZEN at the same time. • Programs cannot be written to LED-type CPU Units without the ZEN Support Software or a Memory Cassette.
Memory Cassette
Support Software
6
Note: Memory Cassettes created using the CPU Unit can be read to the CPU Unit, regardless of which model is used, however the following points must be taken into consideration. When using a Memory Cassette created with a V1 CPU Unit for a Pre-V1 CPU Unit, use the Memory Cassette within the ranges for the Pre-V1 CPU Unit's timers, holding timers, counters, weekly timers, calendar timers, and displays. When using a Memory Cassette created with a CPU Unit with 20 I/O points for a CPU Unit with 10 I/O points, use only up to 6 inputs and 4 outputs for the I/O bit area.
Use ZEN-SOFT01-V3 ZEN Support Software Ver. 3.0 or later when using CPU Units with 20 I/O points. CPU Unit
ZEN Support Software
Pre-V1 Unit V1 Unit
10 I/O points
SOFT01 (Ver. 1.0)
SOFT01-V2 (Ver. 2.0)
SOFT01-V3 (Ver. 3.0)
ZEN-SOFT01 and ZEN-SOFT-V2 ZEN Support Software (versions 1.0 and 2.0) can be used with ZEN-10C -V1 CPU Units (V1 Units with 10 I/O points) but only half of each of the timer, holding timer, counter, weekly timer, calendar timer, and display function areas can be used (i.e., the Pre-V1 bit range).
20 I/O points
7
Page 5
Flexible Control with a Wide Variety of Instructions Programs can consist of up to 96 lines with 3 program inputs and 1 output per line. Bits Name
Bit Symbol addresses
No. of points
Input bits
I
I0 to Ib*
12
Expansion input bits
X
X0 to Xb
12
Output bits
Q
Expansion output bits
Q0 to Q7*
Details
Operation
Date setting
Reflect the ON/OFF status of the input devices connected to the input terminals on the CPU Unit. Reflect the ON/OFF status of the input devices connected to the input terminals on the Expansion I/O Units.
8
Y
Y0 to Yb
12
M
M0 to Mf
16
Work bits can be used only within the ZEN program. I/Os for external devices cannot be made (i.e., all I/O is internal).
Holding bits
H
H0 to Hf
16
Used the same as the work bits. However, if the power to the ZEN is turned OFF, these bits also maintain the previous ON/OFF status. X: ON-delay timer
T
T0 to Tf
: (box) OFF-delay timer
16
O: One-shot pulse timer
#0 to #7
8
Hold the present value being counted even if the trigger input or power supply is turned OFF and continue timing when the trigger input or power is restored.
Counters
C
C0 to Cf
16
Reversible counters that can be incremented and decremented.
Weekly timers
@
@0 to @f
16
Turn ON and OFF during specified times on specified days.
0 to f
16
Turn ON and OFF between specified dates.
D0 to Df
16
Display any character string, time, or analog-converted display of timer or counter present values.
A0 to A3
4
D A
Timer/counter comparator bits
P
Button input bits
B
P0 to Pf B0 to B7
8
Sun
Stop time 17:30
Backlight Terminal mode switching
L0: Backlight does not turn ON (ignored if already ON). L1: Backlight turns ON L2: Terminal mode switching (backlight not ON) L3: Terminal mode switching (backlight ON)
Display start position
X (digit): 00 to 11 Y (line): 0 to 3
Display object
CHR DAT CLK I4 to I5 T0 to Tf #0 to #7 C0 to Cf
Monitoring
A: Can read settings during operation. D: Cannot read settings during operation.
Apr 1 Jan 1
X00
X11
Y0 to Y3
Characters (up to 12 characters - English, numerals, symbols) Month/day (5 digits ) Hour/minute (5 digits ) Analog-converted value (4 digits ) Timer present value (5 digits ) Holding timer present value (5 digits ) Counter present value (4 digits )
Bit *0 turns ON between April 1 and August 31.
Specifications for Button Input Bits
ALT
Analog Comparator Operation Example a. When input 1 ≥ 5.2 V Setting 10.0 5.2 00.0 0.0 A0 bit
A: Alternate
R: Reset
I1
I2
I3
SQ 1
RQ 1 b. When input 1 ≤ input 2 Input 1 (I4 converted display)
Setting 10.0
10.0V Input voltage
0.0 A1 bit
Button input 7 (B7) Input 1 (I4 converted display) Input 2 (I5 converted display)
Time a. When Timer 0 (T0) ≥ 12 min 20 s b. When Counter 1 (C1) is ≤ Counter 2 (C2).
Setting 99.99
Setting 9999
DEL Button input 6 (B6) Button input 5 (B5) Button input 4 (B4) Button input 3 (B3) Button input 2 (B2)
I1
I2
I3
Q0
Q1
Q1
Q2
Button input 1 (B1)
ESC 12.20 00.00 00 min 00 s 12 min 20 s P0 bit
Q1 will stay ON once the execution condition I1 has turned ON once. A reset is used to turn Q1 OFF.
Q1 is forced OFF when the execution condition I2 is turned ON.
OK
Counter 1 (C1)
AQ 2
I0
Q0 will turn ON or OFF depending on the ON/OFF status of the execution condition I0.
Sat
Timer/Counter Comparator Operations
S: Set [ Q0
Fri
Start date Sep 1 Stop date
Additional Bit Output Functions I0
Thurs
Dec 31
* CPU Units with 10 I/O points have 6 input bits (I0 to I5) and 4 output bits (Q0 to Q3). [ : Normal
Wed
Input condition @0 turns ON between 8:15 and 17:30, Tuesday to Friday every week.
Used as program input conditions to output analog comparator comparison results. These bits can be used only for 24-VDC input CPU Units. Compare the present values of timers (T), holding timers (#), and counters (C). Comparison can be made between the same two counters or timers, or with constants. Used as program input conditions and turn ON when operation keys are pressed in RUN Mode. These input bits can be used only with LCD-type CPU Units.
16
Tues
Calendar timer *0 bit
#
Analog comparator bits
Mon
Calendar Timer Operation
Holding timers
Display bits
24:00
Display Settings
Start time 8:15 00:00 Weekly timer @0 input condition
Time units can be selected from the following: 0.01-s unit: 0.01 to 99.99 s min/s unit: 00 min 01 s to 99 min 59 s h/s unit: 00 h 01 min to 99 h 59 min
Functions are selected from the screen when parameter settings are made.
F: Flashing pulse timer
Calendar timers
Time setting
The ON/OFF status of these output bits is used to control the output devices connected to the output terminals on the CPU Unit. The ON/OFF status of these output bits is used to control the output devices connected to the output terminals on the Expansion I/O Units.
Work bits
Timers
Weekly Timer Operation
0000 Timer present value
Counter 2 (C2)
Button input 0 (B0)
P1 bit
Q2 alternates between turning ON and OFF when the execution condition I3 turns ON.
Using Timers and Holding Timers Available timers
Holding timers (#0 to #7) X
ON-delay timer only
ON-delay timer
OFF-delay timer
One-shot pulse timer
Flashing pulse timer
Turns ON after set delay after the trigger input turns ON.
Turns ON after set delay after the trigger input turns ON.
Stays ON while the trigger input is ON and turns OFF after a set delay after the trigger input has turned OFF.
Turns ON for a set period after the trigger input turns ON and regardless of how long the trigger input remains ON.
Repeatedly turns ON and OFF in a set cycle while the switch is ON.
0
0
Useful for OFF delay circuits for lights or fans.
Useful for set operations where operation is always required during a regular period only.
Timer type
Operation
Trigger input Reset input Setting Present value Timer input condition Main applications
Timers (T0 to Tf)
X
0
0
To continue operation after momentary power loss or power interruptions.
O
F
0
Useful for flashing emergency lights or sounding buzzers as the output for an alarm circuit.
When delayed operation or a time lag is required.
Counter Operation The counter bit turns ON when the counter value (present value) reaches the set value (present value set value). The count returns to 0 and the counter bit turns OFF when the reset input turns ON. Count inputs are not accepted while the reset input is turned ON. The counter present value and counter bit (ON/OFF) are held even if the operating mode is changed or the power supply is interrupted.
I0(DIR) I1(CNT) I2(RES) Setting Present value 0000 Counter C0 bit
8
9
Page 6
Input Specifications
Units with AC Power Supply CPU Units with 10 I/O Points (V1 and Pre-V1 Units)
CPU Units with 20 I/O Points
• AC Inputs (Not Isolated)
100 to 240 VAC, 50/60 Hz, 30 VA L
CPU Unit
Expansion I/O Units
L
N
N
Circuit protector
Circuit protector
Item
L
N
Circuit protector
Input devices
Input devices L1 L2/N
NC I0 I1 I2 I3 I4 I5
NC I6 I7 I8 I9 Ia Ib
Specifications
Input voltage
100 to 240 VAC +10%, –15%, 50/60 Hz
Input impedance
680 kΩ
Input current
0.15 mA/100 VAC, 0.35 mA/240 VAC
Units with DC Power Supply
Ω
330 kΩ
IN
ON voltage
80 VAC min.
OFF voltage
25 VAC max.
ON response time
50 ms or 70 ms at 100 VAC (See note.) 100 ms or 120 ms at 240 VAC (See note.)
OFF response time
Circuit drawing
51 kΩ
0.1 µF
Internal circuit
100 to 240 VAC N L
Note: Can be selected using the input filter settings.
CPU Units with 10 I/O Points • For connections to negative (–) common (V1 Units)
• Input terminal I4/I5 analog input device connections (input range: 0 to 10 V)
24 VDC, 6.5 W
• For connections to positive (+) common (V1 Units)
Item
24 VDC, 6.5 W
24 VDC, 6.5 W DC power supply
Input devices
Input devices COM
COM
COM
• DC Inputs I0 to I3 (I0 to I9 for Units with 20 I/O points), V1 Units (Photocoupler Isolated) Specifications
Input voltage
24 VDC +10%, –15%
Input impedance
5 kΩ
Input current
5 mA (typ.)
ON voltage
16.0 VDC min.
OFF voltage
5.0 VDC max.
ON response time Note: Provide power to the COM and power supply terminals at the same time.
Note: Always connect analog input devices to the negative (–) COM terminal.
Note: I4/I5 cannot be used as analog input terminals with a positive (+) common terminal connection.
Circuit drawing kΩ
750 kΩ
24 VDC
COM
Internal circuit
2200PF
15 ms or 50 ms (See note.)
OFF response time Note: Can be selected using the input filter settings.
CPU Units with 20 I/O points • Input terminal Ia/Ib analog input device connections (input range: 0 to 10 V)
24 VDC, 6.5 W
24 VDC, 6.5 W
COM I0
I1
I2
I3
I4
I5
NC I6
I7
I8
I9
Ia
COM I0
Ib
Item
I1
I2
I3
I4
I5
NC I6
I7
I8
I9
Ia
Input devices
Ib
COM I0
Specifications
I1
I2
I3
I4
I5
NC I6
I7
I8
I9
Ia
Ib
Input impedance
5 kΩ
Input current
5 mA (typ.)
ON voltage
14.0 VDC min.
OFF voltage
4.5 VDC max.
Expansion I/O Units • Expansion I/O Units (DC input type) 24 VDC, 6.5 W
Analog inputs
Note 1. Ia/Ib cannot be used as analog input terminals with a positive (+) common terminal connection. 2. Provide power to the COM and power supply terminals at the same time.
Input range
0 to 10 V
External input impedance
150 kΩ min.
Resolution
0.1 V (1/100 FS)
Overall accuracy (–
150 k
4 kΩ 4
Internal circuit
Ω
COM
27 kΩ
15 ms or 50 ms (See note.)
OFF response time Note: Always connect analog input devices to the negative (–) COM terminal.
27 kΩ
24 VDC
ON response time Note: Provide power to the COM and power supply terminals at the same time.
Circuit drawing
–15%
Input voltage
24 VDC, 6.5 W
DC power supply
Input devices
• DC Inputs I14 and I15 (Ia and Ib for Units with 20 I/O points), V1 Units (Not Isolated)
• For connections to positive (+) common
DC inputs
• For connections to negative (–) common
°C)
AD conversion data
27 kΩ
IN Analog voltage output device
10% FS
IN
4 kΩ
COM
150 kΩ 0.01 F
100 kΩ
2.4
Ω
Internal circuit 27 kΩ
0 to 10.5 V (in increments of 0.1 V)
When connecting analog I/O devices, always connect the negative (–) side to the COM terminal.
Note: Can be selected using the input filter settings.
Input devices
Expansion I/O Unit • AC Inputs (Photocoupler Isolated) Item
100 to 240 VAC +10%, –15%, 50/60 Hz
Input impedance
83 kΩ
Input current
1.2 mA/100 VAC, 2.9 mA/240 VAC
Output Circuit Wiring
ON voltage
80 VAC min.
Units with Relay Outputs
OFF voltage
25 VAC max.
ON response time
50 ms or 70 ms at 100 VAC (See note.) 100 ms or 120 ms at 240 VAC (See note.)
Note: Expansion I/O Units can be connected to either the positive (+) or negative (–) common terminal.
All four relay output circuits in both CPU Units with 10 I/O points and Expansion I/O Units have independent contacts. CPU Units with 20 I/O points have 4 independent contacts (Q0 to Q3) and the remaining four (Q4 to Q7) have 2 points/common. There are no restrictions for polarity.
OFF response time
Circuit drawing
Specifications
Input voltage
Internal circuit
100 to 240 VAC
Note: Can be selected using the input filter settings.
CPU Units with 20 I/O points
CPU Units with 10 I/O points
Expansion I/O Units
Q4
Q5
Q6
Q7
OUT0
OUT1
OUT2
OUT3
Load
Load
Load
Load
Load
Load
Load
Q3 Load
Q2 Load
Load
Load
Q1 Load
Q0
Q3 Load
Q2 Load
Load
Q1
Load
• DC Inputs (Photocoupler Isolated) Q0
Item Switching capacity 250 VAC, 8 A (cos
= 1)
24 VDC, 5 A
Transistor Output Type All four transistor output circuits in both CPU Units with 10 I/O points and Expansion I/O Units have independent contacts. CPU Units with 20 I/O points have 4 independent contacts (Q0 to Q3) and the remaining four (Q4 to Q7) have 2 points/common. The terminals have polarity, but the power supply and load connections can be swapped.
24 VDC +10%, –15%
Input impedance
4.7 kΩ
Input current
5 mA (typ.)
ON voltage
16.0 VDC min.
OFF voltage
5.0 VDC max.
ON response time
Circuit drawing
Specifications
Input voltage
15 ms or 50 ms (See note.)
2,200 pF
750Ω
Internal circuit
24 VDC COM
OFF response time Note: Can be selected using the input filter settings.
CPU Units with 20 I/O points + Q4 Q5
- + Q6 Q7
OUT0
OUT1
OUT2
OUT3
Load
-
Load
+ Q3
Load
+ Q2
Load
-
Q1
Load
+
Load
Q0
Load
+
Load
Q3
Load
+
Load
-
Load
Q2
Load
+
Load
Q1
Load
+
Load
Q0 Load
+
Expansion I/O Units
Load
CPU Units with 10 I/O points
Switching capacity 24 VDC, 0.5 A
10
11
Page 7
Output Specifications (CPU Unit/Expansion I/O Unit)
Dimensions (Unit: mm)
• Relay Output Type
• CPU Units with 10 I/O Points (LCD/LED Types)
Item
Specifications
Circuit drawing
Maximum switching capacity
250 VAC/8 A (Resistive load: cos = 1) 24 VDC/5 A (Resistive load)
Minimum switching capacity
5 VDC/10 mA (Resistive load)
• With Battery Unit Mounted
70 60
56 44
87.5 44
17.5
70
Q4/Q6
Resistive load: 50,000 times (cos = 1) Inductive load: 50,000 times (cos = 0.4)
Mechanical
10 million times 15 ms max.
OFF response time
5 ms max.
COM s with 20 I/O points only
45
90 80
45
Q5/Q7
The life, under the worst conditions, of the output contacts used in ZEN relay outputs is given in the above table. Guidelines for the normal life of the relays are shown in the diagram on the right.
Life-test Curve (usage: 360 times/hour) 3)
ON response time
L
Internal circuit
ZEN-BAT01
Relay life
Electrical
1,000
250-VAC resistive load
500
24-VDC resistive load/250-VAC inductive load 24-VDC inductive load (t=7 ms)
300
100
• CPU Units with 20 I/O Points (LCD/LED Types)
50
56 44
122.5 112.5
30 10
I6
0
2
4
6
8
I7
I8
I9
Ia
Ib
10 Contact current (A)
• Item
Specifications
Circuit drawing 20C1AR-A-V1
Maximum switching capacity
24 VDC +10%, –15%, 500 mA
Leakage current
0.1 mA max.
Residual voltage
1.5 V max.
ON response time
1 ms max.
OFF response time
1 ms max.
Each circuit is composed of an independent common circuit.
Q0 to Q3/OUT0 to OUT3
45
90 80
L
24 VDC L
COM +
Internal circuit
L
Units with 20 I/O points only
Q4/Q6
Q4
Q5
Q6
Q7
L
Q5/Q7
• With Battery Unit Mounted
General Specifications Item
Specification ZEN-
0C
AR-A-V1
Item ZEN-
0C
D
-D-V1
100 to 240 VAC
Rated power supply voltage
85 to 264 VAC
20.4 to 26.4 VDC
30 VA max. (With 3 Expansion Units connected)
6.5 W max. (With 3 Expansion Units connected)
Inrush current
40 A max.
10 A max.
Insulation resistance
Between power supply AC external and input terminals, and relay output terminals: 20 M min. (at 500 VDC)
Dielectric strength
Between power supply AC external and input terminals, and relay output terminals: 2,300 VAC, 50/60 Hz for 1 minute with leakage current of 1 mA max.
Noise immunity
Conforms to IEC61000-4-4, 2 kV (power supply line)
Vibration resistance
Conforms to JIS C0040, 10 to 57 Hz, amplitude 0.075 mm, 57 to 1,500 Hz, acceleration: 9.8 m/s2 80 minutes in X, Y, and Z directions (sweep time: 8 min (No. sweeps: 10 = 80 min.))
Shock resistance
24 VDC
Conforms to JIS C0041. 147 m/s2, 3 times in X, Y, and Z directions.
Ambient temperature
LCD-type CPU Unit (operation panel and calendar/clock function): 0 to 55˚C LED-type CPU Unit (no operation panel or calendar/clock function): –25 to 55˚C
Ambient humidity
10% to 90% (with no condensation)
Ambient conditions
No corrosive gases
Ambient storage temperature
LCD-type CPU Unit (operation panel and calendar/clock function): –20 to 75˚C LED-type CPU Unit (no operation panel or calendar/clock function): –40 to 75˚C
44
140 122.5
17.5
I6
Specification
Control method
Stored program control
I/O control method
Cyclic scan
Programming language
Ladder diagram
Program capacity
96 lines (3 input conditions and 1 output per line)
Max. No. of control I/O points
44 points CPU Unit: 12 inputs and 8 outputs Expansion I/O Units: 4 inputs and 4 outputs each, up to 3 Units.
LCD display
12 characters x 4 lines, with backlight (LCD-type CPU Unit only)
Operation keys
8 (4 cursor keys and 4 operation keys) (LCD-type CPU Unit only)
Memory backup
Internal EEPROM (or optional Memory Cassette) • User programs • Parameter settings Internal RAM, super-capacitor hold (or optional Battery Unit) • Holding bits • Holding timer and counter values Super capacitor hold (or optional Battery Unit) • Calendar and clock
Super-capacitor holding time
2 days min. (25˚C)
Battery life (ZEN-BAT01)
10 years min. (25˚C)
Time function (RTC)
ZEN- 0C1 - only, accuracy: 1 to 2 min/month (at 25˚C)
Terminal block
Solid-line terminal block (Use solid lines or fine wiring terminals.)
Power supply holding time
ZENZEN-
Weight
300 g max.
ZEN-BAT01
Power supply voltage
Power consumption
12
Performance Specifications
I7
I8
I9
Ia
Ib
20C1AR-A-V1
45
Q4
Q5
Q6
Q7
• Expansion I/O Units (4 inputs, 4 outputs, 8 I/O)
56 44
• Unit Mounting Hole (Same for all Units)
0C 0C
AR-A: 10 ms min. D -D: 2 ms min.
4.5 90 80
45 5.5
13