Manual · Omron
ZEN Programmable Relays (New Product News)
Manual8 pagesPDF 4.1 MB
OMRON New Product News brochure for the ZEN programmable relays (V1 CPU units), with application examples and the model lineup.
What this file really is
The old site listed this file as a manual for the Omron ZEN-10C1AR-A-V1 /AC100 and ZEN-10C1DR-D-V2. The file is named for the ZEN-10C1DR-D-V2, but this brochure lists the V1 models (such as the ZEN-10C1DR-D-V1) and does not mention a V2 unit.
Names · 1 model
The models it names
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
An OMRON New Product News brochure for the ZEN programmable relay. It shows application examples with sample ladder programs (car wash, assembly checks, fan control, escalator, test equipment, lighting), describes the main features such as front panel ladder programming on the LCD, holding timers, expansion I/O units and memory cassettes, and lists the 10-point and 20-point CPU units (including the ZEN-10C1AR-A-V1 and ZEN-10C1DR-D-V1) and expansion units. It notes it is not to be used to operate the unit.
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
OMRON New Product News brochure for the ZEN V1 programmable relays: CPU Units from the ZEN-10C1AR-A-V1 to the ZEN-20C2DT-D-V1, Expansion I/O Units and options. It shows application examples, the instruction set, specifications and the differences from pre-V1 units. It covers V1 units only and never names the ZEN-10C1DR-D-V2 the site also files it under.
- Device
- ZEN-10C1AR-A-V1: LCD-type programmable relay CPU Unit, AC type with relay outputs, 6 inputs and 4 outputs p. 3, 5
- Power supply
- AC-supply units: 100 to 240 VAC, 50/60 Hz; DC-supply units: 24 VDC p. 3, 6
- Power consumption
- AC-supply units: 30 VA max. with 3 Expansion Units connected; DC-supply units: 6.5 W max. p. 7
- AC inputs
- CPU Units with AC supply: 100 to 240 VAC +10%, –15%; ON 80 VAC min., OFF 25 VAC max.; 0.15 mA at 100 VAC p. 6
- Relay outputs
- 250 VAC/8 A or 24 VDC/5 A resistive, 5 VDC/10 mA min.; independent contacts on 10 I/O-point CPU Units p. 6, 7
- Programming
- Ladder diagram, 96 lines (3 input conditions and 1 output per line) p. 7
- Expansion
- Up to 3 Expansion I/O Units, 44 I/O points max.: ZEN-8EAR, ZEN-8EDR, ZEN-8EDT (4 inputs, 4 outputs), ZEN-4EA, ZEN-4ED (4 inputs), ZEN-4ER (4 relay outputs) p. 3, 7
- Display and keys
- LCD types: 12 characters x 4 lines with backlight, 8 keys p. 7
- Memory backup
- Programs and settings in internal EEPROM or optional Memory Cassette; super-capacitor holds clock and holding data 2 days min. (25˚C); ZEN-BAT01 battery 10 years min. p. 7
- Options
- ZEN-ME01 Memory Cassette, ZEN-CIF01 Connecting Cable, ZEN-BAT01 Battery Unit, ZEN-SOFT01-V3 Support Software (CD-ROM) p. 8
- Timers and counters
- V1 CPU Units: 16 timers, 8 holding timers, 16 counters, twice the pre-V1 units p. 3, 8
- Relay life
- Electrical 50,000 operations (resistive or inductive load); mechanical 10 million p. 7
- Operating temperature
- LCD-type CPU Units 0 to 55˚C; LED-type CPU Units –25 to 55˚C p. 7
- Clock accuracy
- LCD-type units: 1 to 2 min/month (at 25˚C) p. 3, 7
What this manual walks you through
- Application examples with ladder programs: car wash, fans, escalator, lighting, testing p. 2
- Choosing CPU Units and Expansion I/O Units p. 3, 4
- Creating, simulating, monitoring and printing programs with the Support Software p. 4
- Bits, timers, counters, weekly and calendar timers, and display settings p. 5
- Input specifications and input wiring for AC and DC units p. 6
- Wiring relay and transistor outputs p. 6
- Output, general and performance specifications, and dimensions p. 7
- Differences between V1 and pre-V1 CPU Units p. 8
- Which Support Software version works with which CPU Unit p. 4, 8
- How the ZEN runs a ladder program compared with a PLC p. 8
Good to know
- The brochure itself says not to use it to operate the Unit. p. 1
- Programs cannot be written to LED-type CPU Units without the Support Software or a Memory Cassette. p. 4
- The Connecting Cable and Memory Cassette cannot be connected at the same time. p. 4
- DC-supply units: I4 and I5 cannot be analog inputs with positive (+) common wiring. p. 6
- Support Software versions 1.0 and 2.0 can use only half of the timer, counter and display areas of 10-point V1 units. p. 4, 8
Questions this manual answers
What is the ZEN-10C1AR-A-V1?
An OMRON ZEN programmable relay CPU Unit: LCD type, AC type with relay outputs, with 6 input bits and 4 output bits. p. 3, 5
Which ZEN Support Software works with V1 CPU Units?
ZEN-SOFT01-V3 (Ver. 3.0 or later) is needed for 20-point units; versions 1.0 and 2.0 work with 10-point V1 units but use only half of the timer, counter and display areas. p. 4, 8
How long does a ZEN V1 keep its clock without power?
The super-capacitor holds it 2 days min. at 25˚C; the ZEN-BAT01 Battery Unit extends this to 10 years min. p. 7
How many I/O points can a ZEN V1 system have?
Up to 44: a CPU Unit with 12 inputs and 8 outputs plus up to 3 Expansion I/O Units of 4 inputs and 4 outputs each. p. 7
What is in the ZEN-KIT01-EV3?
A ZEN-10C1AR-A-V1 CPU Unit, a Support Software Connecting Cable, the ZEN Support Software and a manual. p. 8
The whole text · 2 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file