Spec sheet · Phoenix Contact
QUINT-PS-100-240AC/24DC/5 Single-Phase Primary-Switched Power Supply Unit
Spec sheet11 pagesPDF 685 KB
Data sheet for the Phoenix Contact QUINT-PS-100-240AC/24DC/5 single-phase 24 V DC, 5 A switched power supply.
Covers · 1 model
The models it covers
Summary
What is in it
Phoenix Contact data sheet for the QUINT-PS-100-240AC/24DC/5, a single-phase primary-switched power supply with a 24 V DC, 5 A output. It gives ordering data and accessories, full input, output, DC OK signal, general, climatic and certification data, a block diagram, safety notes, installation and mounting positions, input and output wiring and fusing, signaling and the DC OK LED, and how the output curve, temperature response, parallel, redundant and increased power operation work.
Its parts
- Description
- Ordering Data
- Technical Data
- Safety Notes and Warning Instructions
- Installation
- Connection of Various Types of Network: 100...240 V AC Networks
- Connection of the Connecting Cable
- Input
- Output
- Function
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
The Phoenix Contact data sheet (12/2005, 100029_04_en) for the QUINT-PS-100-240AC/24DC/5, a single-phase primary-switched DIN rail power supply with a 24 V DC, 5 A output. It gives the input, output and signal data, mounting and wiring steps, and how to use the DC OK signals and run several units in parallel.
- Device
- Single-phase primary-switched power supply, 24 V DC, 5 A; order number 29 38 58 1 p. 2
- Input
- 100...240 V AC nominal (85...264 V AC or 90...350 V DC), 45...65 Hz; about 1.6 A at 120 V AC, 0.84 A at 230 V AC p. 2
- Output voltage
- 24 V DC ±1%, adjustable 22.5...28.5 V DC by potentiometer p. 2, 4
- Output current
- 5 A (-25...+60°C); 7.5 A with POWER BOOST (-25...+40°C); above +60°C derate 2.5% per Kelvin p. 2
- Mains buffering
- > 20 ms at 120 V AC, > 120 ms at 230 V AC (nominal load) p. 2
- Fusing
- Internal 5 A slow-blow fuse; backup circuit breaker 6 A, 10 A or 16 A, Characteristic B p. 2
- DC OK signals
- Active transistor output, +24 V DC, 40 mA max; floating relay contact, 30 V AC/DC, 1 A max; both signal output below 90% of nominal p. 2, 3
- Efficiency
- > 89% at 230 V AC; residual ripple < 100 mVpp p. 2
- Wire terminals
- COMBICON screw/plug-in; 0.2...2.5 mm², AWG 25...14; torque 0.5...0.6 Nm; strip 7 mm p. 8
- Size and weight
- 55 mm x 130 mm x 125 mm (W x H x D); 122 mm x 130 mm x 58 mm flat mounted; 0.830 kg p. 3
- Mounting
- Horizontal NS 35 DIN rail (EN 60715); IP20; 5 cm clear above and below p. 3, 5
- Environment
- Operating -25...+70°C (derating above 60°C); storage -40...+85°C; 95% humidity at +25°C, no condensation p. 3
- Parallel operation
- Up to five units of the same type in parallel for redundancy or more power p. 11
- Accessories
- QUINT-PS-ADAPTERS7/1 (29 38 19 6) for S7 300 rails; QUINT-DIODE/40 (29 38 96 3) decoupling for 100% redundancy; UTA 107 DIN rail adapter p. 2, 4, 11
What this sheet walks you through
- Snapping the unit onto and off a DIN rail p. 6
- Flat mounting with the UTA 107 adapter p. 7
- Connecting to single-phase and three-phase networks p. 7
- Wiring the input, output and signal terminals p. 8, 9
- Monitoring the supply with the DC OK outputs and LED p. 9, 10
- Looping the DC OK signals of several units p. 10
- Parallel units for redundancy or more power p. 11
- Output derating with temperature p. 11
Good to know
- The unit holds dangerous live parts and stored energy; never work on it with the power on. p. 5
- The COMBICON connectors may only be plugged or unplugged with the power off. p. 8
- Leave 5 cm above and below the unit for convection. p. 5
- A blown internal fuse most likely means a device fault, and the unit should be checked at the factory. p. 8
- Heavy inductive loads such as relays on the floating contact need a protective circuit, for example a free-wheeling diode. p. 9
Questions this sheet answers
What is the order number of the QUINT-PS-100-240AC/24DC/5?
The data sheet lists order number 29 38 58 1. p. 2
Can the QUINT-PS-100-240AC/24DC/5 run from a DC input?
Yes. Its input range includes 90...350 V DC, and a suitable fuse should be provided for DC use. p. 2, 8
What does a flashing DC OK LED mean on a QUINT power supply?
The output voltage has fallen below 90% of nominal. p. 3
How much current can the QUINT 24 V 5 A supply deliver with POWER BOOST?
7.5 A at up to +40°C; the nominal 5 A is available up to +60°C. p. 2
How many QUINT supplies can be connected in parallel?
A maximum of five devices of the same type. p. 11
Contents
Chapters and sections
Each line opens the PDF at its page.
- Description1
- Ordering Data2
- Technical Data2
- Safety Notes and Warning Instructions5
- Installation5
- Connection of Various Types of Network: 100...240 V AC Networks7
- Connection of the Connecting Cable8
- Input (1)8
- Output9
- Function10
1 more line, from page 11 on
The whole text · 2 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file