The text of a manual · part 1 of 8
DARTScanner Process Data Collector Operating Instructions: Title Page
Pages 1 to 7 of 52, from DARTScanner Process Data Collector Operating Instructions
The original document is the PDF (5.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the RJG DS-3000
Page 1
DARTScannerTM Process Data Collector Operating Instructions © 1996, 1997, 1999, 2000
Making Molding Simple™ RJG, Inc. Rev 9.10 10/00
Page 2
RJG, Inc. Request for Correction Please complete and fax this form if you find any errors in this publication. Title Revision
Please describe the corrections needed on the lines below. Specify if it is a text or figure change. What is incorrect?
Page #
Please describe the corrections needed on the lines below. Specify if this is a completeness, clarity, or sequence change. What needs improvement?
Please fill out the information below: Name Company Address Phone ( ) Fax ( ) Email
Page #
Title City
State
Zip
Page 3
RJG, Inc.
1 Contents 1. Table of Contents - Tables - Figures 2. Quick Reference – Overview 1 DARTScanner location 2 Machine interface 3 Control interface 4 Mold pressure transducer interface 5 Hydraulic pressure transducer interface 6 Linear stroke, rotary stroke and rotary stroke/velocity transducer interface 7 Network or stand alone computer interface 3. User Section Figure A: DARTScanner front panel 3.1 Display select switch 3.2 Display 3.3 Test/Track mode switch 3.4 Calibrate/Zero switch Figure B: DARTVision transducer scaling screen 3.5 Enable push button 3.6 Transmit LED 3.7 Receive LED 3.8 Trigger LEDs 3.9 Manual trigger button 3.10 On/Off switch 3.11 Alarm LEDs 3.12 Control LEDs Figure C: Side and back mount connectors 3.13 RS-232 connector 3.14 DARTNET connector (RS-485) 3.15 Channel 1 – hydraulic pressure (HYD) 3.16 Channels 2, 3, 4 & 5 – mold pressure transducers (MP1-MP4) 3.17 MP1/MP2 control connector 3.18 Machine interface connector 3.19 Trigger 1 – injection forward (INJFWD) 3.20 Trigger 2 – fill (FILL) 3.21 Trigger 3 – screw run (SCRRUN) 3.22 Trigger 4 – mold close (MLDCLS) 3.23 Trigger common 4. Installation 4.1 A note on DARTScanner placement Table 1: DARTScanner technical specifications 4.2 Machine interface installation Figure 1: Connection of control interface and machine interface to molding machine TM
TM
TM
TM
TM
~5~
DARTScanner™ Rev 9.10
Page 4
RJG, Inc.
4.2.1 T-INT14-M Installation Figure 2: Cut out dimensions for installation of T-INT14-M panel mount connector in inches (mm) Table 2: Machine interface connector pin and pigtail cable guide 4.2.2 Power inputs Table 3: Power input range of DARTScanner 4.2.3 Trigger inputs Figure 3: Trigger wiring guide Table 4: Trigger voltage ranges 4.2.4 Alarm connections Table 5: Alarm relay contact ratings 4.3 Machine transfer control installation 4.3.1 T-CNT12-M Installation Figure 4: Cut out dimensions for installation of T-CNT12-M panel mount machine control connector in inches (mm) Table 6: Machine control interface connector pin and pigtail cable guide 4.3.2 Overview of control types Table 7: Comparison of control type options 4.3.3 Contact closure control 4.3.4 Conditioned 0-10V analog/conditioned 0-20mV analog control Table 8: Control output and scale output ranges Figure 5: Typical mold pressure curve with a peak at full-scale pressure of the transducer Figure 6: Voltage output relating to the mold pressure curve of Figure 5, Gain=500 Figure 7: Voltage output relating to the mold pressure curve of Figure 5, Gain=250 Table 9: Minimum control voltage output resistance Table 10: Control relay contact ratings 4.4 Transducer connector interface installation 4.4.1 Transducer inputs Figure 8: DARTScanner transducer input connectors Table 11: Transducer input connector pin-out guide Figure 9: Pinout guide 4.4.2 Initial factory settings Table 12: Channel assignments & gain settings 4.4.3 Gain set switches Figure 10: DARTScanner inside front panel Table 13: Gain switch positions, transducer input ranges 4.4.4 Interfacing with an STX-25 stroke/velocity transducer 4.4.5 Interfacing with a mold deflection transducer Figure 11: Board with jumpers Table 14: Mold deflection jumper assignments 4.5 Computer and network interface installation TM
TM
TM
DARTScanner™ Rev 9.10
~6~
Page 5
RJG, Inc.
4.5.1 COM 1 pin-outs Figure 12: Interfacing a stand-alone computer to a DARTScanner using the RS-232 computer hook up on the DARTScanner’s side panel Table 15: COM 1 pin-outs 4.5.2 DARTNET connector (RS-485 computer interface) Figure 13: Interfacing a multi-machine DARTScanner Network to a computer using network cabling and the RS-485 DARTNET connector on the DARTScanner Table 16: DARTNET pin-outs 5. Product disclaimer 6. Appendix 6.1 Appendix A: Installation Notes 6.1.1 Scanner Footprint Figure 14: DARTScanner footprint 6.1.2 Cutouts 6.1.2.1 T-CNT12-M Figure 15: T-INT14-M machine interface connector panel cut out 6.1.2.2 T-INT14-M Figure 16: T-CNT12-M control connector panel cut out 6.1.3 Using the T-INT14-Junction Figure 17: Using the T-INT14 Junction 6.1.4 Interfacing with Nissei machines Figure 18: Interfacing with the Nissei machines Table 17: Outputs (24 VAC) from controller for RJG triggers 6.2 Appendix B: Special Applications 6.2.1 Temp 1 module Figure 19: Insert – mounting hole Figure 20: Temp module setup 6.2.2 DS-5000-C-SHTL- Switching Box Supplemental Table 18: Guide to shuttle switching Figure 21: Check the Shuttle Table check box for proper operation 6.3 Appendix C: Using Accessories 6.3.1 Sensor simulator instructions Figure 22: Sensor Simulator Table 19: Strain-Gage switch positions (mVolts) Table 20: High-Level switch positions (Volts) 6.3.2 Transducer cable tester instructions Table 21: Specifications Figure 23: Transducer cable tester 6.4 Appendix D: Troubleshooting Guide Table 22: Troubleshooting guide 6.5 Appendix E: Failsafe Alarms Overview Figure 24: Failsafe Good part cycle Figure 25: Failsafe Bad part cycle Figure 26: Failsafe Good part cycle with pinched part Figure 27: Failsafe Bad part cycle with pinched part Figure 28: Two bin sorting using DARTScanner™ with failsafe option TM
TM
TM
TM
~7~
DARTScanner™ Rev 9.10
Page 6
RJG, Inc.
Table 23: Itemized changes between the standard DARTScanner™ and the DARTScanner™ with failsafe option 7. Glossary
Figures USER SECTION Figure A: DARTScanner front panel Figure B: DARTVision transducer scaling screen Figure C: Side and back mount connectors TM
TM
INSTALLATION SECTION Figure 1: Connection of control interface and machine interface to molding machine Figure 2: Cut out dimensions for installation of T-INT14-M panel mount connector in inches (mm) Figure 3: Trigger wiring guide Figure 4: Cut out dimensions for installation of T-CNT12-M panel mount machine control connector in inches (mm) Figure 5: Typical mold pressure curve with a peak at full-scale pressure of the transducer Figure 6: Voltage output relating to the mold pressure curve of Figure 5, Gain=500 Figure 7: Voltage output relating to the mold pressure curve of Figure 5, Gain=250 Figure 8: DARTScanner transducer input connectors Figure 9: Pin-out guide Figure 10: DARTScanner inside front panel Figure 11: Board with jumpers Figure 12: Interfacing a stand-alone computer to a DARTScanner using the RS-232 COM 1 computer hook up on the DARTScanner’s side panel Figure 13: Interfacing a multi-machine DARTScanner Network to a computer using network cabling and the RS-485 DARTNET connector on the DARTScanner TM
TM
TM
TM
TM
TM
APPENDIX A Figure 14: DARTScanner footprint Figure 15: T-INT14-M machine interface connector panel cut out Figure 16: T-CNT12-M control connector panel cut out Figure 17: Using the T-INT14 – junction Figure 18: Interfacing with Nissei machines TM
APPENDIX B Figure 19: Insert – mounting hole Figure 20: Temp module setup Figure 21: Check the shuttle table check box for proper operation
DARTScanner™ Rev 9.10
~8~
Page 7
RJG, Inc.
APPENDIX C Figure 22: Sensor Simulator Figure 23: Transducer cable tester APPENDIX E Figure 22: Sensor Simulator Figure 23: Transducer cable tester
Tables INSTALLATION Table 1: DARTScanner technical specifications Table 2: Machine interface connector pin and pigtail cable guide Table 3: Power input ranges of DARTScanner Table 4: Trigger voltage ranges Table 5: Alarm relay contact ratings Table 6: Machine control interface connector pin and pigtail cable guide Table 7: Comparison of control type options Table 8: Control output and scale output ranges Table 9: Minimum control voltage output resistance Table 10: Control relay contact ratings Table 11: Transducer input connector pin-out guide Table 12: Channel assignments & gain settings Table 13: Gain switch positions, transducer input ranges Table 14: Mold deflection jumper assignments Table 15: COM 1 pin-outs Table 16: DARTNET pin-outs TM
TM
APPENDIX A Table 17: Outputs (24 VAC) from controller for RJG triggers APPENDIX B Table: 18: Guide to shuttle switching APPENDIX C Table 19: Strain-gage switch positions (mVolts) Table 20: High-level switch positions (Volts) Table 21: Specifications APPENDIX D Table 22: Troubleshooting Guide APPENDIX E Table 23: Itemized Changes between the standard DARTScanner™ with failsafe option
~9~
DARTScanner™ Rev 9.10