Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of DARTScanner Process Data Collector Operating Instructions

Manual · RJG

DARTScanner Process Data Collector Operating Instructions

Manual52 pagesPDF 5.7 MB

Operating instructions for the RJG DARTScanner process data collector used with injection molding machines and pressure transducers.

Download the PDF5.7 MB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

RJG's operating instructions for the DARTScanner process data collector, which connects to an injection molding machine and its hydraulic and mold pressure transducers. It explains the front panel switches, display, LEDs and connectors, then covers installation of the machine interface, triggers and alarms, machine transfer control, transducer inputs and gain switches, and RS-232 or RS-485 DARTNET computer links, with appendices on panel cutouts, Nissei machines, accessories, troubleshooting and failsafe alarms.

Its parts

  1. Quick Reference - Overview
  2. User Section - Interfacing
  3. Installation
  4. RJG Product Disclaimer

From the manual

Key facts from this manual

Each line names its page in the PDF.

Operating instructions (Rev 9.10) for the RJG DARTScanner process data collector, which the site files under the DS-3000; the pages read never print that model number. It explains the front panel, how to wire the unit to an injection molding machine, its transducers and a computer, and how to troubleshoot it.

Read for this summary: pages 1 to 2, 8 to 16, 18, 20, 26, 32 to 33 and 44 to 47 of 52.

What it is
A process monitoring unit mounted permanently on an injection molding machine, read by DARTVision software p. 10, 12
Input channels
5 channels on 6 pin female connectors labeled HYD, MP1, MP2, MP3 and MP4 p. 9
Sampling
100 samples per second per channel, 12 bit A/D (1 part in 4096) p. 16
Power input
85 to 264 VAC, 47-440 Hz, or 120 to 370 VDC; 1 Amp max at 115 VAC, fused at 2.5 A p. 18
Trigger inputs
Fill, Injection Forward, Screw Run and Mold Closed; AC 17 to 250 VAC or DC 24 to 250 VDC p. 18, 20
Transducer gain
Low gain (1) 0 to 5 V or 0 to 10 V; Mid gain (250) -20 mV to +20 mV; High gain (500) -10 mV to +10 mV p. 16
Computer link
RS-232 by a DB-9 male to DB-9 female cable, or 15-pin RS-485 DARTNET multi-drop network; proprietary protocol p. 14, 16, 32
Alarm outputs
Two contact closure outputs (any alarm, and cycle time); relay rated 15 A at 120 VAC resistive, 10 A at 30 VDC resistive or 277 VAC, 1/2 HP at 250 VAC, 1/3 HP at 120 VAC p. 20, 47
Control outputs
Contact closure, conditioned 0-10V or conditioned 0-20mV, one or two channels; control relay 50 watts, 500 VDC or peak AC, 1 A, 13mS p. 8, 14, 26
Interface cables
T-INT14-M and T-INT14-D machine interface, T-CNT12-M and T-CNT12-D control, T-520 transducer cable p. 8, 14
Network parts
TPJ-361 cable to an SP-321M splitter p. 14
Hydraulic sensor
A T-3000U hydraulic transducer on channel 1, connected by a T-520 cable p. 14
Trigger wire colors
Trigger 1 blue, Trigger 2 pink, Trigger 3 orange, Trigger 4 brown, trigger common grey p. 15
Default gain
Channels are pre-set to gain 250 (mid) p. 14

What this manual walks you through

  • Reading the front panel display, switches and LEDs p. 10, 11, 12, 13
  • Zeroing and calibrating a channel at job start p. 11
  • Wiring the four machine triggers p. 14, 15, 18
  • Powering the unit from the machine's line power p. 18
  • Connecting the alarm outputs for part rejection p. 20
  • Wiring cavity pressure control for machine transfer p. 20, 26
  • Connecting one unit to a computer by RS-232, or several by an RS-485 network p. 32, 33
  • Troubleshooting display, communication, trigger and calibration problems p. 44, 45, 46
  • Using the failsafe alarm option p. 47

Good to know

  • A Trigger 1 signal must be supplied before the unit shows any data. p. 14
  • Only one communications port, RS-232 or DARTNET, can be used at a time. p. 14, 33
  • The machine may be on but should not be cycling during zero and calibration. p. 11
  • The control relay is not horsepower rated and should not drive machine solenoids directly. p. 26
  • Placing the unit close to a material hopper or dryer is not recommended because of static electricity. p. 16

Questions this manual answers

What power supply does the DARTScanner need?

85 to 264 VAC at 47-440 Hz, or 120 to 370 VDC, drawing at most 1 Amp at 115 VAC. Machine line power is the recommended source. p. 18

Can the DARTScanner use RS-232 and RS-485 at the same time?

No. Either the RS-232 port or the RS-485 DARTNET port can be used, not both. p. 33

Which machine triggers does the DARTScanner need?

Trigger 1 (Injection Forward) is all that is needed to start collecting data; Fill, Screw Run and Mold Close are optional. p. 14, 15

Why is the pressure curve cut off at half scale?

The channel is likely set to High Gain (500). Set its gain switch back to Mid Gain (250) and recalibrate the channel. p. 46

Why is there no display when the DARTScanner powers up?

The power wires may not be connected properly, or the fuse inside the power supply may be blown. p. 44

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Title Page1
  2. Quick Reference - Overview8
  3. User Section - Interfacing10
    1. Display Control Switch10
    2. LCD Display11
    3. Test Mode Switch11
    4. Calibrate/Zero Switch11
    5. Transmit LED12
    6. Receive LED12
    7. Trigger LEDs12
    8. Manual Trigger Button12
    9. Alarm LEDs13
    10. Control LEDs13
    11. RS-232 Connector13
    12. DARTNET Connector (RS-485)14
    13. Channel 1 - Hydraulic Pressure (HYD)14
    14. Channels 2, 3, 4 & 5 - Mold Pressure Transducers (MP1 - MP4)14
    15. MP1/MP2 Control Connector14
    16. Machine Interface Connector14
    17. Trigger 1 - Injection Forward (INJFWD)15
    18. Trigger 2 - Fill (FILL)15
    19. Trigger 3 - Screw Run (SCRRUN)15
    20. Trigger 4 - Mold Close (MLDCLS)15
    21. Trigger Common15
  4. Installation16
    1. A Note on DARTScanner™ Placement16
    2. Machine Interface Installation17
    3. Machine Transfer Control Installation20
    4. Transducer Connector Interface Installation27
    5. Computer and Network Interface Installation32
  5. RJG Product Disclaimer34
  6. Appendix A: Installation Notes35
    1. DARTScanner™ Footprint35
    2. Cutouts36
    3. Using the T-INT14-Junction37
    4. Interfacing with Nissei machines38
  7. Appendix B: Special Applications39
    1. T-TEMP1 Installation & Use39
    2. DS-5000-C-SHTL Switching Box Supplemental40
    3. Important Software Note41
6 more lines, from page 42 on
  1. Appendix C: Using Accessories42
    1. Sensor Simulator use instructions42
    2. Transducer Cable Instructions43
  2. Appendix D: Troubleshooting Guide44
  3. Appendix E: Failsafe Alarms Overview47
  4. Glossary52

From the PDF’s own bookmarks.

The whole text · 8 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Title Page1-7
  2. Pages 8 to 158-15
  3. Installation, pages 16 to 2416-24
  4. Installation, pages 25 to 3325-33
  5. Pages 34 to 3834-38
  6. Appendix B: Special Applications39-41
  7. Pages 42 to 4642-46
  8. Pages 47 to 5247-52

The file

Revision and size

RevisionRev 9.10, 10/00
PublisherRJG, Inc.
Pages52
PDF5.7 MB
TextText from the PDF itself.

The first pages · 3 of 52

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 52
Page 2
Page 2of 52
Page 3
Page 3of 52