Manual · RJG
DARTScanner Process Data Collector Operating Instructions
Manual52 pagesPDF 5.7 MB
Operating instructions for the RJG DARTScanner process data collector used with injection molding machines and pressure transducers.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
RJG's operating instructions for the DARTScanner process data collector, which connects to an injection molding machine and its hydraulic and mold pressure transducers. It explains the front panel switches, display, LEDs and connectors, then covers installation of the machine interface, triggers and alarms, machine transfer control, transducer inputs and gain switches, and RS-232 or RS-485 DARTNET computer links, with appendices on panel cutouts, Nissei machines, accessories, troubleshooting and failsafe alarms.
Its parts
- Quick Reference - Overview
- User Section - Interfacing
- Installation
- RJG Product Disclaimer
From the manual
Key facts from this manual
Each line names its page in the PDF.
Operating instructions (Rev 9.10) for the RJG DARTScanner process data collector, which the site files under the DS-3000; the pages read never print that model number. It explains the front panel, how to wire the unit to an injection molding machine, its transducers and a computer, and how to troubleshoot it.
- What it is
- A process monitoring unit mounted permanently on an injection molding machine, read by DARTVision software p. 10, 12
- Input channels
- 5 channels on 6 pin female connectors labeled HYD, MP1, MP2, MP3 and MP4 p. 9
- Sampling
- 100 samples per second per channel, 12 bit A/D (1 part in 4096) p. 16
- Power input
- 85 to 264 VAC, 47-440 Hz, or 120 to 370 VDC; 1 Amp max at 115 VAC, fused at 2.5 A p. 18
- Trigger inputs
- Fill, Injection Forward, Screw Run and Mold Closed; AC 17 to 250 VAC or DC 24 to 250 VDC p. 18, 20
- Transducer gain
- Low gain (1) 0 to 5 V or 0 to 10 V; Mid gain (250) -20 mV to +20 mV; High gain (500) -10 mV to +10 mV p. 16
- Computer link
- RS-232 by a DB-9 male to DB-9 female cable, or 15-pin RS-485 DARTNET multi-drop network; proprietary protocol p. 14, 16, 32
- Alarm outputs
- Two contact closure outputs (any alarm, and cycle time); relay rated 15 A at 120 VAC resistive, 10 A at 30 VDC resistive or 277 VAC, 1/2 HP at 250 VAC, 1/3 HP at 120 VAC p. 20, 47
- Control outputs
- Contact closure, conditioned 0-10V or conditioned 0-20mV, one or two channels; control relay 50 watts, 500 VDC or peak AC, 1 A, 13mS p. 8, 14, 26
- Interface cables
- T-INT14-M and T-INT14-D machine interface, T-CNT12-M and T-CNT12-D control, T-520 transducer cable p. 8, 14
- Network parts
- TPJ-361 cable to an SP-321M splitter p. 14
- Hydraulic sensor
- A T-3000U hydraulic transducer on channel 1, connected by a T-520 cable p. 14
- Trigger wire colors
- Trigger 1 blue, Trigger 2 pink, Trigger 3 orange, Trigger 4 brown, trigger common grey p. 15
- Default gain
- Channels are pre-set to gain 250 (mid) p. 14
What this manual walks you through
- Reading the front panel display, switches and LEDs p. 10, 11, 12, 13
- Zeroing and calibrating a channel at job start p. 11
- Wiring the four machine triggers p. 14, 15, 18
- Powering the unit from the machine's line power p. 18
- Connecting the alarm outputs for part rejection p. 20
- Wiring cavity pressure control for machine transfer p. 20, 26
- Connecting one unit to a computer by RS-232, or several by an RS-485 network p. 32, 33
- Troubleshooting display, communication, trigger and calibration problems p. 44, 45, 46
- Using the failsafe alarm option p. 47
Good to know
- A Trigger 1 signal must be supplied before the unit shows any data. p. 14
- Only one communications port, RS-232 or DARTNET, can be used at a time. p. 14, 33
- The machine may be on but should not be cycling during zero and calibration. p. 11
- The control relay is not horsepower rated and should not drive machine solenoids directly. p. 26
- Placing the unit close to a material hopper or dryer is not recommended because of static electricity. p. 16
Questions this manual answers
What power supply does the DARTScanner need?
85 to 264 VAC at 47-440 Hz, or 120 to 370 VDC, drawing at most 1 Amp at 115 VAC. Machine line power is the recommended source. p. 18
Can the DARTScanner use RS-232 and RS-485 at the same time?
No. Either the RS-232 port or the RS-485 DARTNET port can be used, not both. p. 33
Which machine triggers does the DARTScanner need?
Trigger 1 (Injection Forward) is all that is needed to start collecting data; Fill, Screw Run and Mold Close are optional. p. 14, 15
Why is the pressure curve cut off at half scale?
The channel is likely set to High Gain (500). Set its gain switch back to Mid Gain (250) and recalibrate the channel. p. 46
Why is there no display when the DARTScanner powers up?
The power wires may not be connected properly, or the fuse inside the power supply may be blown. p. 44
Contents
Chapters and sections
Each line opens the PDF at its page.
- Title Page1
- Quick Reference - Overview8
- User Section - Interfacing10
- Display Control Switch10
- LCD Display11
- Test Mode Switch11
- Calibrate/Zero Switch11
- Transmit LED12
- Receive LED12
- Trigger LEDs12
- Manual Trigger Button12
- Alarm LEDs13
- Control LEDs13
- RS-232 Connector13
- DARTNET Connector (RS-485)14
- Channel 1 - Hydraulic Pressure (HYD)14
- Channels 2, 3, 4 & 5 - Mold Pressure Transducers (MP1 - MP4)14
- MP1/MP2 Control Connector14
- Machine Interface Connector14
- Trigger 1 - Injection Forward (INJFWD)15
- Trigger 2 - Fill (FILL)15
- Trigger 3 - Screw Run (SCRRUN)15
- Trigger 4 - Mold Close (MLDCLS)15
- Trigger Common15
- Installation16
- RJG Product Disclaimer34
- Appendix A: Installation Notes35
- Appendix B: Special Applications39
The whole text · 8 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file