The text of a manual · part 3 of 8
DARTScanner Process Data Collector Operating Instructions: Installation, pages 16 to 24
Pages 16 to 24 of 52, from DARTScanner Process Data Collector Operating Instructions
The original document is the PDF (5.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the RJG DS-3000
Page 16
RJG, Inc.
4 Installation 4.1 A Note on DARTScannerTM Placement The DARTScannerTM can be located anywhere that is convenient, however, it is recommended that it not be placed too close to a material hopper or dryer. Material hoppers and dryers create a high level of static electricity and although the DARTScannerTM is protected from such discharges, it is a sensitive data collection device capable of being damaged in very extreme circumstances. Important technical specifications for the DARTScanner are listed in Table 1. TM
M e a s u re m e nt s
R a t ing A C : 8 5 VA C t o 2 6 4 VA C ; 4 7 - 4 4 0 H z
Power input range
DC: 120 to 370 VDC
Operating tempe rature range Tr a n s d u c e r Input Ranges
0-60C (-15F - 140F)
Low gain (1)
0 t o 5 V, 0 t o 1 0 V
Mid gain (250)
- 2 0 mV to +20mV
High gain (500)
- 1 0 mV to +10mV 0 V, 1 0 V ( f a c t o r y s t a n d a r d )
Excitation voltages
0 V, 1 5 V ( j u m p e r s e l e c t a b l e ) - 1 5 V, 1 5 V ( j u m p e r s e l e c t a b l e )
Ma ximum common mode voltage
±10V
Shunt calibration resistance
200kΩ
Shunt calibration percentage of full scale (350 Ω bridge)
21.856%
Number of acquisition channels
5 independent sampling channels
Sampling rate per individual c hannel
100 samples per second
S a mp ling r e s o l u t i o n
1 Part in 4096 (12 bit A/D) A C : 1 7 VA C - 2 5 0 V A C
Machine trigger voltage ranges M inimum control voltage output resistance
DC: 24VDC - 250VDC
0 to 10V Output
1kΩ
0 to 20mV Output
100kΩ Maximum switching power Maximuim s w itching voltage
Control relay contact ratings
Alarm relay contact ratings
Serial c ommunications types
Maximum switching and carry currents
50 watts 500 VDC or Peak AC 1A ( l i m i t e d b y c u r r e nt limit fuse)
Maximum control contact s w itching time after 13mS seeing set-point 1 5 A @ 120VAC resistive 1 0 A @ 3 0 V D C r e s is tiv e o r 2 7 7 V A C 1 / 2 H P @ 2 5 0 VAC 1 / 3 H P @ 1 2 0 VAC RS- 232 (proprietary protocol) RS- 485 (proprietary protocol)
Table 1: DARTScannerTM technical specifications ~19~
DARTScanner™ Rev 9.10
Page 17
RJG, Inc.
4.2 Machine Interface Installation A DARTScannerTM interfaces to the molding machine using the Control Interface and Machine Interface cables (see Figure 1).
Figure 1: Connection of Control Interface and Machine Interface to molding machine
4.2.1 T-INT14-M Installation A DARTScannerTM is provided with a T-INT14-M panel mount connector with pigtail wires, see Figure 2, that is used to interface the DARTScannerTM to a molding machine. Once installed into the molding machine, use the supplied T-INT14-D to connect the DARTScannerTM to the T-INT14-M. (See Table 2 for a wiring guide.)
Figure 2: Cut out dimensions for installation of T-INT14-M panel mount control interface connector in inches (mm) DARTScanner™ Rev 9.10
~20~
Page 18
RJG, Inc. Pin
Signal
Signal flow
Wire Color
A
F ill (Trigger 2)
M a chinea DARTS c a n n e r ™
PINK**
B
Injectio n forward (Trigger 1)
M a chinea DARTS c a n n e r ™
BLUE
C
Screw run (Trigger 3)
M a chinea DARTS c a n n e r ™
ORANGE**
D
Mold close (Trigger 4)
M a chinea DARTS c a n n e r ™
DARK BROWN **
E
AC commo n
M a chinea DARTS c a n n e r ™
WHITE
F
* Line power
M a chinea DARTS c a n n e r ™
BLACK
G
Ground
M a chinea DARTS c a n n e r ™
GREEN
H
Trigger common
M a chinea DARTS c a n n e r ™
GRAY
J
Alarm contact normally open
DARTS c a n n e r ™ a M a chine
RED**
K
Alarm commo n
DARTS c a n n e r ™ a M a chine
LT BROWN **
L
C yc le t ime alarm contact normally open
DARTS c a n n e r ™ a M a chine
VIOLET
M
C yc le time alarm commo n
DARTS c a n n e r ™ a M a chine
YELLOW**
N
Reserved
-
**
P
Reserved
-
**
Table 2: Machine interface connector pin and pigtail cable guide * Reference Table 3 for range ** These pigtailed wires have been individually shrink wrapped and the ends are tinned. The wires are optional for installation and if left exposed could cause unwanted problems. If needed for installation the shrink-wrap can be removed.
4.2.2 Power Inputs It is recommended that if the machine supplies line power this is the power source that should be used to supply the DARTScannerTM with power (see Table 3 for range). It is also recommended that the machine ground be double-checked to insure a solid connection. Power input range AC Range
8 5 VAC to 264 VAC; 47-440 Hz
DC Range
120 to 370 VDC
Frequency
47-440 Hz
M a x Current
1 Amp @ 11 5 VAC ( fus e d @ 2 . 5 A)
Table 3: Power input range of DARTScannerTM
4.2.3 Trigger Inputs In order to do important computations relevant to the injection molding process, the DARTScannerTM needs certain signals from the machine controller. These signals indicate to the DARTScannerTM when important events happen during the machine cycle. They help synchronize signals from the hydraulic and mold pressure transducers to the actions of the machine for display in the DARTVisionTM software. DARTScannersTM use the following four signals (triggers) from the machine controller: • Fill: signal is on only during the fill phase of injection • Injection Forward: signal is on during entire time of injection forward (fill, pack, and hold) • Screw Run: signal is on during screw run time (recovery) • Mold Closed: signal is on while mold clamp pressure is high
~21~
DARTScanner™ Rev 9.10
Page 19
RJG, Inc.
These signals can be taken directly from the valve solenoids or from the machine controller (see Figure 3). MACHINE SEQUENCE SOLENOIDS INJ FWD
BOOST (FILL)
SCR RUN
MLD CLD
MACHINE SOLENOID COMMON
T-INT14-M MACHINE INTERFACE PANEL MOUNT SOCKETS A B C D E F
TRIGGER 2
PINK
TRIGGER 1
BLUE
TRIGGER 3
ORANGE
TRIGGER 4
DARK BROWN
POWER NEUTRAL
WHITE
LINE POWER
BLACK
CASE GROUND
GREEN
TRIGGER COMMON
GRAY
CYCLE SELECTOR SWITCH N.C.
J K L M
MASTER ALARM N.O.
RED
MASTER ALARM COMMON
LIGHT BROWN
CYCLE TIME N.O.
VIOLET
CYCLE TIME COMMON
YELLOW
AUTO
AUX. RELAY
G H
SEMI MANUAL
+ 24 VDC
OPTIONAL AUX. RELAY SHOWN WIRED TO MANUAL/SEMI/AUTO CYCLE SELECTOR SWITCH TO STOP TRIGGER 1 & DATA COLLECTION WHEN SETTING UP & PURGING THE MOLDING MACHINE
N P
Figure 3: Trigger wiring guide NOTE: The machine sequence signal input for Trigger 1 (the Master Trigger for the DARTScannerTM) can be wired through the Manual/Semi-Automatic Cycle Selector switch on the press to disable the triggers when not running in Automatic cycle. This prevents the counting of parts and data collection during purging and set-up. Trigger 1 can be wired through an available set of normally closed terminals of the switch, which are opened when the switch is set to the Manual mode.
The DARTScannerTM inputs these trigger voltage signals using opto-isolated circuits to insure full isolation from the machine controller. Since the DARTScannerTM gets its power from the machine panel, machines that use contact closure triggers will have to supply the trigger voltage to the contacts. Powering the DARTScannerTM equipment from the machine panel eliminates problems associated with isolating two power sources. However, for added protection all DARTScannerTM trigger inputs are opto-isolated and all alarm outputs are contact closure.
DARTScanner™ Rev 9.10
~22~
Page 20
RJG, Inc.
Table 4 shows the differential voltage ranges the DARTScannerTM can use for trigger inputs. The DC “On” voltage can be positive or negative as long as when the trigger is “Off,” the differential voltage is zero. Trigger s ignal type AC trigger DC trigger
Voltage range AC : 17VAC - 250VAC DC : 24 V DC - 2 5 0 V DC
Table 4: Trigger voltage ranges
4.2.4 Alarm Connections A DARTScannerTM supplies two contact closure alarm outputs that can be utilized to turn on warning bells and lights or to signal a robot to automatically reject a part. The contacts will stay open until the DARTScannerTM detects a variant cycle. The DARTScannerTM is shipped so that the cycle time alarm does not affect the master alarm (See Table 5 for contact ratings.) However, the ability to tie the Cycle Time Alarm output to the Master Alarm output is user selectable by moving a jumper inside the DARTScannerTM. Please contact RJG Customer Support at 231-947-3111 for assistance. Al a rm re lay contact ratings 15 A @ 120 VAC resistive 10 A @ 30 VDC resistive o r 277 VAC 1/2 HP @ 250 VAC 1/3 HP @ 120 VAC Table 5: Alarm relay contact ratings
4.3 Machine Transfer Control Installation 4.3.1 T-CNT12-M Installation A DARTScanner is provided with a T-CNT12-M panel mount connector with pigtail wires (see Figure 4) that is used to transfer the machine using the DARTScanner . Once installed, use the supplied T-CNT12D to connect the DARTScanner to the T-CNT12-M (see Table 6 for a wiring guide.) TM
TM
TM
Figure 4: Cut out dimensions for installation of T-CNT12-M panel mount machine interface connector in inches (mm)
~23~
DARTScanner™ Rev 9.10
Page 21
RJG, Inc. Pin
S ignal
Signal Flow
G
MPT 1: +Analog signal (0 - 1 0 V)
DARTScanner™ a Machine
H
M PT 1: Analog signal c o mmmon (0-10V)
DARTScanner™ a Machine
A
MPT 1: +Analog signal (0-20mV)
DARTScanner™ a Machine
B
M PT 1: Analog signal c o mmon (0-20mV)
DARTScanner™ a Machine
J
M PT 1: Tra nsfer contact normally open
DARTScanner™ a Machine
M
MPT 1: Transfer common
DARTScanner™ a Machine
C
MPT 2: +Analog signal (0 - 1 0 V)
DARTScanner™ a Machine
D
MPT 2: Analog signal common (0-10V)
DARTScanner™ a Machine
E
MPT 2: +Analog signal (0-20mV)
DARTScanner™ a Machine
F
M PT 2: Analog signal c o mmon (0-20mV)
DARTScanner™ a Machine
L
M PT 2: Tra nsfer contact normally open
DARTScanner™ a Machine
K
MPT 2: Transfer common
DARTScanner™ a Machine
Wire C o l o r P a ir g P a ir g P a ir g P a ir g
RED BLAC K WHITE BLAC K GREEN BLAC K BLUE BLAC K
P a ir g
YELLOW
P a ir g
BRO W N
BLAC K
BLAC K
Table 6: Machine control connector pin and pigtail cable guide
4.3.2 Overview of Control Types A DARTScannerTM supplies three types of signals for Cavity Pressure Control: Contact Closure, Conditioned 0-10V Analog and Conditioned 0-20mV Analog. The user should select just one type of control that best suits their needs. Table 7 is provided as a guide to the three different control options. CAUTION: When programming your machine to accept a RJG cavity pressure transfer control input you must utilize any time, pressure or stroke overrides in the machine control algorithm. If a set point is set incorrectly or a transducer is removed from the mold, the cavity pressure may not reach a transfer set point so there must be a backup to keep from flashing or damaging a tool. Though one channel is typical, a DARTScannerTM may be configured with two or more Mold Pressure Control channels. Each Machine Control Connector is capable of carrying up to two channels of Mold Pressure Control. (Refer to Table 6 for Machine Control Connector pin and pigtail cable guide.) Here are some ways to utilize multi-channel mold pressure control: • • • •
One or more channels as redundant backup control for the first channel Letting the first channel, of multiple channels, that reaches set-point transfer the machine Multiple set-points for rising and falling control edges Two or more channels must reach pressure for transfer to happen
While currently it is rare to configure more than one cavity pressure control channel, the addition of one or more cavity pressure measurements for monitoring is common. The T-CNT12-M connector(s) can also be used to interface any additional number of monitoring channels. DARTScanner™ Rev 9.10
~24~
Page 22
RJG, Inc.
Control t ype
Typical usage
Signal excitation & aut oze ro
Signal calibration re quire me nts
C o nt rol set-point re quire me nts
Press control does not have a mold pressure transfer setup screen (common w/retrofits)
Provided by the DARTScanner™
None by the press control - All calibration done by the DARTScanner ™
Contact C losure
Ability to select external boost cuto ff & set a safety transfer set-point
Conditioned Press control has high- level mold pressure analog transfer on its (0-10V) screens
Provided by the DARTScanner™
See scaling notes
Mold pressure and safety transfer setp o ints
Press control has mold pressure Conditioned transfer, but has lo w - level a redundant analog signal ( 0 - 2 0 mV) conditioner that cannot be bypassed
Provided by the DARTScanner™
See scaling notes
Mold pressure and safety transfer setp o ints
Table 7: Comparison of control type options
4.3.3 Contact Closure Control If Contact Closure Control is selected the machine controller will need to provide the ability to select external boost cut-off & set a safety transfer set-point. The DARTScanner provides a normally open set of contacts that will close when the mold pressure passes through the set-point on the rising slope and will open when the pressure falls through the set-point. The DARTScanner provides all signal excitation, auto zeroing and calibration. TM
TM
4.3.4 Conditioned 0-10V Analog/Conditioned 0-20mV Analog Control If Conditioned 0-10V Analog or Conditioned 0-20mV Analog control is selected, the machine controller must provide the ability to choose the following parameters on the set-up screens: • • • •
Choice of Direct (mounted flush to the cavity) or Indirect (placed behind an ejector pin) Sensor If Indirect Sensor, the Ejector Pin Size and/or Ejector Pin Area Full Scale Rating of Transducer being used by the DARTScannerTM (force if indirect, pressure if direct) Single or Multi-channel control configuration (optional)
~25~
DARTScanner™ Rev 9.10
Page 23
RJG, Inc.
Gain
0 - 10 Volt output rang e
0 - 20mV output range
Switch position
Transducer scale range
Voltage range
Transducer scale range
Voltage range
High (500)
0 to 1/2 full scale
0 to 10 volts
0 to 1/2 full scale
0 to 20mV
Standard Mid (250)
0 to full scale
0 to 10 volts
0 to full scale
0 to 20mV
Low (1)
N/A
N/A
N/A
N/A
Table 8: Control output and scale output ranges
The machine controller will set the scaling based on these parameters. Signal excitation and autozeroing is provided by the DARTScannerTM. Refer to Table 8 for an overview of this scheme. What follows is a detailed explanation of the scaling scheme. Figure 5 shows a typical mold pressure curve whose peak is at exactly full scale of the transducer.
Figure 5: Typical mold pressure curve with a peak at full-scale pressure of the transducer
DARTScanner™ Rev 9.10
~26~
Page 24
RJG, Inc.
Figure 6: Voltage output relating to the mold pressure curve of Figure 5, Gain=500.
Figure 7: Voltage output relating to the mold pressure curve of Figure 5, Gain=250. High Gain (500) Direct Sensor Scaling Notes The DARTScannerTM will provide either a 0 to 20mV signal or a 0 to 10V signal relating to 0 to 1/2 of the full scale rating of the transducer. If the pressure on the transducer goes above half scale, the output will stay at 10 Volts (20mV). Refer to Figure 6 for a graphical representation. Example: A DARTScannerTM utilizing a direct sensor with a full scale rating of 20,000psi will provide a Voltage of 5V (Conditioned High-Level Analog) or 10mV (Conditioned Low-Level Analog) when the direct sensor’s cavity is pressurized to 5,000psi. Pressure = (Signal Voltage/Maximum Signal Voltage)*(1/2 of Full scale Pressure) Pressure = 5,000psi = (5V/10V)*10,000psi (Conditioned High-Level Analog Signal Voltage) Pressure = 5,000psi = (10mV/20mV)*10,000psi (Conditioned Low-Level Analog Signal Voltage) ~27~
DARTScanner™ Rev 9.10