RJG, Inc.
2 Quick Reference - Overview Attach STX-25V body to a NON-MOVING part of the injection unit
T-520STV-D5 Cable
6
T-520 Cable
5
STX-25V Attach ring to a MOVING part on the Injection Ram, such as the Screw Feed pointer. 0
Ejector or Dummy Pin
T-41X Sensor
T-X000 Hydraulic Sensor
8
4 T-615X Sensor
Cavity Pressure
Molding Machine
Mold T-520 Cable
CN-485
7
OEM Controller
Network
T-320
RJG, Inc. Traverse City, MI 49686 (231) 947-3111 or RS-232 Stand Alone Computer
2
3
4
1
TEST
5
T-CNT12-M
T-INT14-M
3
2
DISPLAY SELECT CALIBRATE
ZERO
1
DATA TRANSMIT
MANUAL
TRIGGERS
1 INJ FWD
RECEIVE
2 FILL
4 MLD CLS
3 SCR RUN
TRIGGER
PROCESS ALARMS/CONTROLS
T-CNT12-D
ALARM/REJECT
1
2
3
CONTROL
4
5
CYCLE/ WARNING
T-INT14-D
T-520 Cable
1
DARTScannerTM Location - The DARTScannerTM can be located anywhere that is convenient. However, there are certain considerations that should be taken into account. Refer to Section 4.1 for more information.
2
Machine Interface - In order to do important computations relevant to the injection molding process, the DARTScannerTM needs certain triggers from the machine controller. These triggers help synchronize signals from the hydraulic and mold pressure transducers to the actions of the machine for display in the DARTVisionTM software. These signals are brought to the DARTScannerTM through the T-INT14-M panel mount connector and T-INT14-D machine interface cable. The DARTScannerTM also supplies two contact closure alarm outputs through the T-INT14-M that can be utilized to turn on warning bells and lights or to signal a robot to automatically reject a part. For more information on installation refer to Section 4.2.1.
3
Control Interface - To allow the use of a pressure or stroke set-point for machine transfer, a DARTScannerTM supplies three types of signals for Cavity Pressure Control: Contact Closure, Conditioned 0-10V and Conditioned 0-20mV. The user should select just one type of control that best suits their needs. A DARTScannerTM is provided with a T-CNT12-M panel mount connector with pigtail wires and a T-CNT12-D to connect the DARTScannerTM to the machine’s controller. For more information on installation refer to Section 4.3.1.
DARTScanner™ Rev 9.10
~10~
Page 9
RJG, Inc.
4
Mold Pressure Transducer Interface - To see the molding process from the plastic’s point of view, mold pressure transducers are interfaced to the DARTScannerTM through the Bendix connectors on the side of the DARTScannerTM. These 6 pin female connectors are labeled HYD, MP1, MP2, MP3 and MP4, relating to channels 1 through 5. Typically those channels labeled MP1, MP2, MP3 and MP4 are used for mold pressure transducers. However all channels have the flexibility to be configured as needed. Refer to Section 4.4 for more information for setting up a transducer channel. For more information on mold pressure transducer installation refer to the Installation and Use Instructions for the RJG sensor you are implementing.
5
Hydraulic Pressure Transducer Interface - To gather information useful in creating rheology curves, hydraulic pressure transducers are interfaced to the DARTScannerTM through the Bendix connectors on the side of the DARTScannerTM. These 6 pin female connectors are labeled HYD, MP1, MP2, MP3 and MP4, relating to channels 1 through 5. Typically the channel labeled HYD is used for hydraulic pressure transducers, however, all channels have the flexibility to be configured as needed. Refer to Section 4.4 for more information for setting up a transducer channel. For more information on hydraulic pressure transducer installation refer to the Installation and Use Instructions for the RJG sensor you are implementing.
6
Linear Stroke, Rotary Stroke and Rotary Stroke/Velocity Transducer Interface - To help determine shot size, stroke-velocity transducers are interfaced to the DARTScannerTM through the Bendix connectors on the side of the DARTScannerTM. Even though these 6 pin female connectors are labeled HYD, MP1, MP2, MP3 and MP4, relating to channels 1 through 5, all channels have the flexibility to be configured for stroke-velocity. Refer to Section 4.4.4 for more information on setting up a stroke-velocity transducer channel. For more information on stroke-velocity transducer installation refers to the Installation and Use Instructions for the RJG sensor that you are implementing.
7
Network or Stand Alone Computer Interface - To access all the information the DARTScannerTM gathers, a computer can communicate with a DARTScannerTM either as a stand-alone unit via the RS-232 connector directly to the computer or on a network with other DARTScannersTM through the DARTNET RS-485 connector. For more information on RS-232 installation refer to Section 4.5.1. For more information on the RS-485 installation refer to Section 4.5.2.
~11~
DARTScanner™ Rev 9.10
Page 10
RJG, Inc.
3 User Section The DARTScanner™ process monitoring system is permanently mounted to your molding machine. Using an RS-485 multi-drop network, you can connect several machines to one central computer to collect data.
Figure A: DARTScanner
3.1
TM front panel
Display Select Control Switch This selects which channel’s data will be displayed in the LCD to the right. This can be set from 15. For example, if you had this set to 1 and that was hydraulic, then the hydraulic pressure for that cycle would be displayed.
DARTScanner™ Rev 9.10
~12~
Page 11
RJG, Inc.
3.2
LCD Display Shows the current signal for the channel that you have selected with the Display Select Switch.
3.3
Test Mode Switch During normal operation, the pressure being read in will track up and down as the pressure rises or falls. If the “Test” switch is pressed, then the raw voltage signal being read in from the transducer will be displayed.
3.4
Calibrate/Zero Switch At job startup, this is used to first zero and then calibrate the channel that is selected by the Display Select Switch. To “Zero” the channel, hold the switch down in the zero position. Then to “Calibrate,” hold the switch up in the calibrate position. You should see a calibration number appear. This number should be within 1% of the calibration number that you see on the Dart Scaling window in the DARTVision™ Software (see Figure B).
Figure B: DARTVision transducer scaling screen TM
NOTE: The molding machine can be “On,” but should not be cycling during the Zero and Calibration. You will need to calibrate each channel, which only needs to be done on a job start or if you change a transducer during a run. Remember that each time you start a new job, you need to calibrate the channels that you will be using.
~13~
DARTScanner™ Rev 9.10
Page 12
RJG, Inc.
3.5
Transmit LED This light will come on when the DARTScanner™ responds to a request for data from DARTVision™.
3.6
Receive LED This light will come on when the DARTScanner™ receives a request for data from DARTVision™.
3.7
Trigger LEDs These are visual representations as to when the actual machine trigger signals are coming on. This will let you know if you have the T-INT14-M machine interface cable wired into the machine properly. Listed below is how the sequence of triggers should look if you have them all hooked up and in the proper locations. 1. Mold will “Close” and Trigger 4 (Mold Closed) will come “On.” 2. Injection Forward (Hydraulics begin pushing plastic) Trigger 1 (Injection Forward), Trigger 2 (Fill Only), and Trigger 4 (Mold Closed) should all be “On.” 3. Filling of the part is done and you are now packing. Trigger 2 (Fill Only) will go “Off”, but Trigger 1 (Injection Forward) and Trigger 4 (Mold Closed) will remain “On.” 4. Fill, Pack and Hold are done, and screw will begin to recover Trigger 1 (Injection Forward) will go “Off”, but Trigger 4 (Mold Closed) will remain “On.” After a brief second Trigger 3 (Screw Run) will come “On.” 5. Screw is done recovering Trigger 3 (Screw Run) and Trigger 4 (Mold Closed) will both go “Off.” 6. Mold Opens, ejects the part, Closes, and the cycle starts over.
3.8
Manual Trigger Button This is used when you do not have any other triggers hooked up to the box. When the Mold closes, you can “Press & Hold” this button and the Trigger 1 light will come “On.” Continue to hold it through Fill, Pack & Hold, and release it when you first hear the screw start to recover. By doing this, you are giving the DARTScanner™ a manual Trigger 1. You can also use the Manual Trigger Button to get data from the DARTScanner™ if you have triggers hooked up but are not cycling the machine. Note: Pushing the Manual Trigger Button does not cycle the machine, it only tells the DARTScanner that one cycle has ended and another has started. TM
DARTScanner™ Rev 9.10
~14~
Page 13
RJG, Inc.
3.9
Alarm LEDs The 1-5 under each one of the lights represents the input channels 1-5 for the transducers. If you have alarm parameters set in the software and have the alarms enabled, when an alarm is generated the light(s) for the channel(s) on which the alarm is generated will light up. You can then go to the Alarms display in the DARTVision™ software to see exactly what the alarm was. The one labeled as Cycle Time will alarm when you have exceeded the cycle time by the percentage that you have set in DARTVision™ setup. NOTE: For simplified operations, see the Appendix.
3.10 Control LEDs The green LED will show you on which channel the control feature is activated. This LED will light when the transducer signal passes up through the set-point and turn off when the signal drops below the set-point.
Figure C: Side mount connectors
Back mount connectors
3.11 RS-232 Connector This is an RS-232 communications port used by the DARTVision™ software to communicate with the DARTScanner™. Connect one end of a 9 to 9 pin serial cable to the DARTScanner™ and plug the other end directly to the serial port on your computer.
~15~
DARTScanner™ Rev 9.10
Page 14
RJG, Inc.
3.12 DARTNET Connector (RS-485) This is a 15-pin RS-485 multi-drop communications port that is used when you have the DARTScanner™ on a network. You would connect one end of the TPJ-361 cable to this port and the other end of the cable to the SP-321M Splitter. NOTE: You can only use one of the communications ports (COM1 or DARTNET) at a time.
3.13 Channel 1 - Hydraulic Pressure (HYD) The Gain is pre-set to 250 or mid. You are supplied a T-3000U hydraulic transducer that needs to be mounted to the injection unit. Once the T-3000U is mounted, take a T-520 cable and connect one end to the hydraulic transducer and the other to channel 1 on the DARTScanner™.
3.14 Channels 2, 3, 4 & 5 - Mold Pressure Transducers (MP1 - MP4) The Gain is pre-set to 250 or mid. Once you have the mold pressure transducer(s) installed in your mold, take a T-520 cable and connect one end to the transducer and the other to either channel 2, 3, 4 or 5. NOTE: The configurations on channels 1-5 are examples. You can order your DARTScanner™ with the configuration that you want ( i.e. Hyd, MPT, MPT, Stroke and Velocity, etc.).
3.15 MP1/MP2 Control Connector This is where you will plug in the T-CNT12-D control cable. This will have one or two channels of control, depending how you order your box. The pigtailed end of the T-CNT12-M will then run into your machine panels and connect to your machine. You will need to reference your machine manual as to the type of control you need to use (Contact Closure, 0-10V or 0-20mv) and the exact connecting point within your machine.
3.16 Machine Interface Connector Connect the T-INT14-D here. The T-INT14-M end will be pigtailed. This pigtailed end is then fed into the machine panel and hard wired to your molding machine. This wire harness contains the line power, Triggers and Alarm Out wires for the DARTScanner™. NOTE: You are required to supply a Trigger 1 signal to see any data on the DARTScanner™. What are triggers and how do I find them on my machine? Triggers are usually signals (24VDC or 120-240VAC, see Table 1 for extended range) that you feed into the DARTScanner™ unit, using the supplied T-INT14-M cable, from the molding machine. These trigger signals indicate to the DARTScannerTM when important events happen during the machine cycle. They help synchronize signals from the hydraulic and mold pressure transducers to the actions of the machine for display in the DARTVisionTM software. There are four triggers that we would like you to hook up. However, if you can only get Trigger 1, that is all that is necessary to begin collecting data. You may have to refer to your machine manual to help you locate these outputs. Here are the trigger inputs that we look for: DARTScanner™ Rev 9.10
~16~
Page 15
RJG, Inc.
3.17 Trigger 1 - Injection Forward (INJFWD) This is when the high volume pumps engage to begin pushing plastic. The signal is “On” during Fill, Pack and Hold and then drops out. Hook the Trigger 1 wire (blue) to the terminal, which will provide this signal. Every machine is different and you will need to refer to the manual for your machine to find this signal.
3.18 Trigger 2 - Fill (FILL) This comes on when the high volume pumps engage to begin pushing plastic. The signal is “On” during Fill Only and then drops out. Hook the Trigger 2 wire (pink) to the terminal, which will provide this signal. This is NOT the same signal as Trigger 1 and you will need to refer to the machine manual to find this trigger. This trigger is optional, but if hooked up, will show you valuable information about your fill times.
3.19 Trigger 3 - Screw Run (SCRRUN) This comes on when the screw starts to recover. The signal is “On” only during Screw Recovery and then drops out. Hook the Trigger 3 wire (orange) to the terminal, which will provide this signal. This trigger is optional, but if hooked up, will show you valuable information about your screw recovery times.
3.20 Trigger 4 - Mold Close (MLDCLS) This comes on when the mold is fully clamped. The signal is “On” during the entire time the Mold is Closed and then drops out when the mold opens. Hook the Trigger 4 wire (brown) to the terminal block slot which will provide this signal. This trigger is optional, but if hooked up, will show you valuable information about your mold closed times.
3.21 Trigger Common This is the common for your triggers and is the grey wire in the multi-colored harness. NOTE: This must be hooked up for your triggers to operate correctly.
~17~