Page 47

RJG, Inc.

6.5 Appendix E: Failsafe Alarms Overview Standard DARTScanner™ Alarm Outputs: Standard DARTScanners™ have 2 contact closure alarm outputs that can be used for sorting parts. The first output is for standard alarms (any alarm from DARTVision™), while the second output is reserved specifically for cycle time alarms. These outputs are normally open contacts that close as soon as the DARTScanner™ detects an alarm during its cycle. Once an alarm has caused a contact to close, this alarm signal stays on until a user-configured trigger is reached. This user-configured trigger is set in the DARTVision™ Machine Settings window, using the “Alarm Turn Off” setting. The choices for “Alarm Turn Off” include: • • •

Next Cy (Next Cycle Start, or Trigger 1 goes ON) T4 On (Trigger 4 goes ON, or start of mold closed) T4 Off (Trigger 4 goes OFF, or end of mold closed) (Trigger 4 turns ON)

For example, let’s say a standard alarm went on at the end of 1st stage injection (such as a fill time alarm) and the “Alarm Turn Off” option in DARTVision™ was set to “Next Cy”. In this case, the alarm output signal would stay on throughout mold opening and closing, and would go off at the start of injection for the next cycle. While the standard DARTScanner™ alarm configuration works well in most conditions, there are cases where a reject part can end up in a good bin. For example, if power to the DARTScanner™ is interrupted, all parts go to the good bin. Also, if there is no alarm but the mold closes on a part (thereby pinching it), the pinched part will fall into the good bin when the mold safety causes the mold to open. The DARTScanner™ with the failsafe option addresses these problems. Failsafe DARTScanner™ Alarm Outputs: The DARTScanner™ with the failsafe option utilizes the same outputs as the standard DARTScanner™, but configures them differently. Here, the first alarm output becomes a ‘Reject Part Indicator’ and the second alarm output becomes a ‘Good Part Indicator.’ If you hook your part divertor to the the ‘Reject Part Indicator’ output, it will behave very similarly to the first channel on the standard DARTScanner™ (divert parts only on alarms). The real power of the failsafe DARTScanner™, though, is when you use the ‘Good Part Indicator’ output for part diverting. Here, the failsafe DARTScanner™ treats all part as rejects until they are proven good. Here, the part divertor shifts to the ‘Reject’ bin at the start of the cycle and remains there until a ‘Good’ part signal is sent. If the power is left off to the DARTScanner™, or parts are stuck in the mold and become pinched, parts automatically go to the ‘Reject’ bin. Let’s look at how the failsafe DARTScanner™ does this. Figure 1 shows a timing diagram for a good part. Notice that at the beginning of injection, both the ‘Good’ and the ‘Reject’ outputs stay OFF (open). This means the failsafe DARTScanner™ is in an “undecided” mode (this can be treated as a third output mode for certain applications). At the end of the integration limit, or at the start of mold opening (Trigger 4 ON), whichever comes first, the failsafe DARTScanner™ looks to see if any alarms went off during the cycle. If not, the ‘Good’ output goes ON (the contact closes), while the ‘Reject’ output remains OFF. The ‘Good’ output stays on until the start of injection for the next cycle, regardless of the “Alarm Turn Off” setting in DARTVision™. ~51~

DARTScanner™ Rev 9.10

Page 48

RJG, Inc.

Next, let’s look at the timing diagram for a cycle where an alarm is detected. This is shown in Figure 2. Again, at the start of injection the failsafe DARTScanner™ is in an “undecided” mode, with both outputs off. At the end of the integration limit or the start of mold opening, the failsafe DARTScanner™ detects the alarm condition and turns the ‘Reject’ output ON. This output stays on until the start of injection for the next cycle – again, the “Alarm Turn Off” setting in DARTVision™ is disabled. The failsafe DARTScanner™ will also send pinched parts to the ‘Reject’ bin, as shown in Figure 3. If the DARTScanner™ sees a second Mold Opening (Trigger 4) signal before it sees an Injection Forward signal for the next cycle, the output will change to ‘Reject’ mode (if not all ready there). This ‘Reject’ signal will stay on until the start of the next cycle. Figure 4 shows the same pinched-part scenario for a cycle that already had alarmed. Finally, until the failsafe DARTScanner™ is fully powered and receives a setup from DARTVision™, neither output is enabled. In this manner, the DARTScanner™ cannot give an indicator of ‘Good’ or ‘Reject’ parts until it is powered and is given sorting parameters. When using the ‘Good’ output to divert parts, this provides a truly failsafe way of ensuring that ‘Reject’ parts are never accidentally sent to the ‘Good’ bin.

Figure 24: Failsafe Good part cycle

Figure 25: Failsafe Bad part cycle DARTScanner™ Rev 9.10

~52~

Page 49

RJG, Inc.

Figure 26: Failsafe Good part cycle with pinched part

Figure 27: Failsafe Bad part cycle with pinched part

A further illustration of 2-bin sorting using the failsafe using the ‘Good’ part output is shown in Figure 5. The parts divertor is set up so that it defaults into the ‘Reject’ parts bin. Figure 5 shows three scenarios – one for no power or no setup loaded, one for a ‘Good’ part signal, and one for a Reject part signal. When the ‘Good’ part contacts close, this signal is used to shift the parts to the good part position .

~53~

DARTScanner™ Rev 9.10

Page 50

RJG, Inc.

Figure 28: Two bin sorting using DARTScanner™ with failsafe option.

DARTScanner™ Rev 9.10

~54~

Page 51

RJG, Inc.

Item

Standard DARTScanner™

DARTScanner™ with failsafe option

Standard Alarm (Reject) output turn ON

As soon as an alarm condition is met during a cycle

As soon as integration limit is reached (or Mold Opening turns ON) and an alarm condition is met

Standard Alarm (Reject) output turn OFF

As set up in the softward. Either T4 (Mold Closed) turns ON or turns OFF or T1 (Injection Forward) turns ON

T1 (Injection Forward) turns ON

Cycle Time Alarm (Good) output turn ON

As soon as intgration limit is reached (or Mold Opening turns ON) and no alarm condition is As soon as a cycle time alarm met (*NOTE* Cycle Time alarms condition is met during a cycle are now part of the regular alarms, and they effect the outputs the cycle after the alarm)

Cycle Time Alarm (Good) output turn OFF

T1 (Injection Forward) turns ON or as a time delay from rising edge of T1

T1 (Injeciton Forward) turns ON

Table 23: Itemized changes between the standard DARTScanner™ and the DARTScanner™ with failsafe option: Important installation notes: • Integral limit in the software should be reached before Mold Open turns on. • Both trigger 1 (injection forward) and Trigger 4 (mold opening) are required for operation • Cycle Time alarms are now part of the regular alarms, and they effect the outputs on the cycle after the alarm occurs

~55~

DARTScanner™ Rev 9.10

Page 52

7 Glossary differential – the degree or amount to which similar things differ disable – to incapacitate or make powerless interface (in computer science) – the point of interaction of communication between a computer and another entity, such as a printer variation – the difference in things that are supposed to be the same redundant – unnecessarily repetitive sequence – the following of one thing after another, a number of things or events that follow each other synchronize – to take place or cause to take place at the same time