6.2 Appendix B: Special Applications 6.2.1 Temp 1 Module T-TEMP1 Installation & Use Overview The RJG T-TEMP1 module takes input from a ‘J’ type thermocouple and outputs 0 to 5 Volts corresponding to 0 to 500°C. This input can be wired to an input on a DARTScanner™ box and be monitored by your DARTVision™ software. To mount the T-TEMP1 module, temporarily remove the front cover and utilize the four mounting holes in the box (see Figure 19). Installation Use the following steps to hook up and monitor temperature using the T-TEMP1, DARTScanner™ box and DARTVision™ software: 1. Power down the DARTScanner™ box. 2. Set the DARTScanner™ box’s Channel Gain switch to a gain of 1 (Low Gain Input). 3. Plug in a T-5XX transducer cable between the DARTScanner™ box and the T-TEMP1 Bendix connector. 4. Plug in a “J” type thermocouple. 5. Power up the DARTScanner™ box. 6. Start a job up in the DARTVision™ software and select the Temp Module Measurement in the Machine window (see Figure 20).

Figure 19: Insert – mounting hole

Figure 20: Temp Module setup

7. Calibrate the channel. 8. Zero the channel by pushingthe TEST button and doing a ZERO. This channel will now be reading the temperature of the thermocouple.

~43~

DARTScanner™ Rev 9.10

Page 40

RJG, Inc.

6.2.2 DS-5000-C-SHTL Switching Box Supplemental Overview The DS-5000-C-SHTL switching box allows a contact closure to switch between control outputs from either Mold “A” or Mold “B” on shuttle or indexing rotary table injection molding machines. This option requires running DARTVision software Version 4.31 or higher. TM

Mold Switching The contact closure’s input is a 4 pin Bendix connector on the right side of the box. The contacts used to switch should be rated for 120VAC @ 1Amp. DO NOT INPUT VOLTAGE ON THE CONNECTORS OF THE DRY CONTACTS. THIS WILL CAUSE DAMAGE TO INTERNAL COMPONENTS. A Limit switch is provided with a Bendix connector ready to interface with the DARTScanner™. The switch should be positioned to activate when the shuttle has moved laterally to bring mold “B” in front of the injection unit. The switch will then return to the normally open position when Mold “A” is in front of the injection unit. Table 18 is provided as a guide for limit switch placement as it relates to the active mold. Mold

Input state

Mold pre s s ure inputs

Control outputs

A

Contact open (Limit switch relaxed)

C hannel 2 C hannel 3

C hannel 2

B

Contact closed (Limit switch depressed)

C hannel 4 C hannel 5

C hannel 4

Table 18: Guide to shuttle switching Control Output Control output for machine transfer is provided on a 6 Pin Bendix connector on the lower right side of the box that provides contact closure, 0-10V and 0-20mV. See your DARTScanner™ manual for more details. Software Setup Notes When setting up the job in your DARTVision™ software two things should be kept in mind. The first is that the Master DART address should always be set to Channel 1 of the box. The second is that if you want to alarm on cycle time, you should do so on Channel 1 but not on the other channels. This is because Channels 2-5 receive triggers only on every other cycle. Because of this when you are collecting data with the DS-5000-C-SHTL, remember that cycle data for Channel 1 always appears but Channel pairs 2-3 and 4-5 alternately appear.

DARTScanner™ Rev 9.10

~44~

Page 41

RJG, Inc.

IMPORTANT SOFTWARE NOTE In the upper right hand portion of the Machine Setup page of the DARTVision™ software, the Shuttle Table check box must be checked for correct operation (see Figure 21). Also, make sure the Integration Limit (found on the Mold Setup window) is set lower than the lowest cycle time of either Mold “A” or Mold “B.” Example: Mold “A” Cycle Time is 10.1 seconds and Mold “B” Cycle Time is 9.9 seconds. Set the Integration Limit lower than 9.9 seconds.

Figure 21: Check the Shuttle Table check box for proper operation.

~45~

DARTScanner™ Rev 9.10