Page 34

RJG, Inc.

5 Product Disclaimer Inasmuch as RJG, Inc. has no control over the use to which others may put this material, it does not guarantee that the same results as those described herein will be obtained. Nor does RJG, Inc. guarantee the effectiveness or safety of any possible or suggested design for articles of manufacture as illustrated herein by any photographs, technical drawings and the like. Each user of the material or design or both should make his own tests to determine the suitability of the material or any material for the design, as well as the suitability of the material, process and/or design for his own particular use. Statements concerning possible or suggested uses of the materials or designs described herein are not to be construed as constituting a license under any RJG Inc. patent covering such use or as recommendations for use of such materials or designs in the infringement of any patent. RJG, Inc. is not responsible for the improper installation of this equipment, or any other equipment, RJG manufactures. Proper RJG equipment installation does not interfere with original equipment safety features of the machine. Safety mechanisms on all machines should never be removed.

~37~

DARTScanner™ Rev 9.10

Page 35

RJG, Inc.

6 Appendix 6.1 Appendix A: Installation Notes 6.1.1 DARTScannerTM Footprint

Figure 14: DARTScanner

~39~

TM footprint

DARTScanner™ Rev 9.10

Page 36

RJG, Inc.

6.1.2 Cutouts 6.1.2.1 T-INT14-M Machine Interface Connector Panel Cut Out

Figure 15: T-INT14-M machine interface connector panel cut out 6.1.2.2 T-CNT12-M Control Connector Panel Cut Out

Figure 16: T-CNT12-M control connector panel cut out

DARTScanner™ Rev 9.10

~40~

Page 37

RJG, Inc.

6.1.3 Using the T-INT14-Junction Installing Multiple DARTScannersTM on one Molding Machine

Mounting Hole Reference

Figure 17: Using the T-INT14-M junction Using the above diagram, a user can take data on a single molding machine using multiple DARTScanners™. Two or more DARTScanners™ are wired to all 4 triggers and collect Trigger Inputs from the machine using the three T-INT14-D cables and the T-INT14-Junction box. The two-control interface cables, T-CNT12-D’s are used to control the machine. Network communications with the two boxes is accomplished using the SP-321M.

~41~

DARTScanner™ Rev 9.10

Page 38

RJG, Inc.

6.1.4 Interfacing with Nissei machines Interfacing with Nissei Machine Outputs:

DARTScanner

NISSEI CONTROL PANEL

TM

** T-DSCP CABLE

TRANSFER CONTROL

UE

INJECTION FORWARD FILL

BL

T-DSMP CABLE

K

ORANGE

Process Alarm/Controls Alarm

BR

TM

Control

PIN

OW

N

MOLD CLOSE

GR

* FILL (1st Stage) SCREW RUN SIGNAL MOLD CLOSE SIGNAL

EY

DARTScanner INTERFACE CABLE

SCREW RUN

INJECTION FORWARD SIGNAL (1st & 2nd Stage)

TRIGGER COMMON

24 VOLTS DC COMMON

**Inputs to the Controller for Pack (P2) to Hold (P3) Transfer

Figure 18: Interfacing with the Nissei machines

The DARTScannerTM provides a Contact Closure signal (not horsepower rated) capable of transferring the machine from Pack to Hold. Nissei machines are only able to take advantage of this by special request to Nissei. The green & black colored pigtailed wires on the T-DSCP cable provide the Contact Closure.

Outputs (24 VDC) from Controller for RJG Triggers: Injection Forward

Tr igger 1

Output to stay ON for duration of 1st and 2nd Stage

Mandatory

* F ill

Tr igger 2

Output to stay O N for duration of 1st Stage (or P1) only

Optional

Screw Run

Tr igger 3

Output to stay ON for dura tion of Screw Recovery

Optional

M o l d C lo s e d

Tr igger 4

O utput to stay ON fo r duration of Mold Closed

Optional

2 4 V D C C o mmon from controller

Mandatory

Tr ig g e r C o mmon

*NOTE: Fill (Trigger 2) should be the only special request. All other Triggers should be standard outputs. Table 17: Outputs (24 VAC) from controller for RJG triggers DARTScanner™ Rev 9.10