Page 25
References (continued)
0
Twido programmable controller
0
Discrete I/O modules
References Separate components Application
Description
Reference
Mounting kit
For fitting discrete modules on a mounting plate or panel Sold in lots of 5
TWDXMT5
Telefast pre-wired system Connection sub-bases for Twido I/O connection sub-bases Pre-wired solutions Cables and accessories
Weight kg –
See page 59
–
HE 10 type connectors Description
Number of ways 20 26
HE 10 female connectors (sold in lots of 5)
Reference TWDFCN5K20 TWDFCN5K26
Weight kg – –
Pre-formed cables for discrete I/O modules with HE 10 connectors Description Pre-formed cables, 1 pre-formed cable: one end with HE 10 connector, one end with free wires
For use with Gauge Cable Twido C.s.a. length 3m Modular base 22 controllers 0.035 mm2 TWD LMDA 22 5m 20DTK/40DTK 0.035 mm2
Reference TWDFCW30M
Weight kg 0.405
TWDFCW50M
0.670
I/O extensions 22 3m TWD DDI 0.035 mm2 16DK/32DK 22 5m TWD DDO 0.035 mm2 16pK/32pK
TWDFCW30K
0.405
TWDFCW50K
0.670
For use with Gauge Cable Twido C.s.a. length 1m Modular base 28 controllers 0.080 mm2 TWD LMDA 28 2m 20DTK/40DTK 0.080 mm2
Reference
Connecting cables (1) Description
ABFTP26MP100
Weight kg 0.200
ABFTP26MP200
0.500
28 3m 0.080 mm2
ABFTP26MP300
0.800
Inputs Discrete input TWD DDI pre-formed cables, 16DK/32DK 1 pre-formed cable: one end with 20-way HE 10 connector on Twido side, one end with 20-way HE 10 connector on Telefast side
28 1m 0.080 mm2 28 2m 0.080 mm2 28 3m 0.080 mm2
ABFTE20EP100
0.080
ABFTE20EP200
0.140
ABFTE20EP300
0.210
Discrete output Outputs pre-formed cables TWD DDO 1 pre-formed cable: one 16TK/32TK end with 20-way HE 10 connector on Twido side, one end with 20-way HE 10 connector on Telefast side
1m 28 0.080 mm2 28 2m 0.080 mm2 28 3m 0.080 mm2
ABFTE20SP100
0.080
ABFTE20SP200
0.140
ABFTE20SP300
0.210
Discrete I/O pre-formed cables, 1 pre-formed cable: one end with 26-way HE 10 connector on Twido side, one end with two 20-way HE 10connectors on Telefast side
(1) Cables strictly for applications other than use of Telefast sub-bases with Twido controllers. For use of Telefast sub-bases with Twido controllers, see pages 50 to 63.
25
Page 26
Twido programmable controller
Dimensions, connections
0
Discrete I/O modules
Dimensions Discrete I/O modules c
2.75” (70 mm)
a
3.54” (90 mm)
0.17” (4.5 mm)
TWD DDI 8DT/DAI 8DT DDI 16DT DDI 16DK DDI 32DK DDO 8UT/8TT DDO 16UK/16TK DDO 32UK/32TK DRA 8RT/16RT DMM 8DRT DMM 24DRF a 0.92” (23.5) 0.92” (23.5) 0.69” (17.6) 1.16” (29.7) 0.92” (23.5) 0.69” (17.6) 1.16” (29.7) 0.92” (23.5) 0.92” (23.5) 1.53” (39.1)
c 0.57” (14.6) 0.57” (14.6) 0.44” (11.3) 0.44” (11.3) 0.65” (16.6) 0.44” (11.3) 0.44” (11.3) 0.57” (14.6) 0.57” (14.6) 0.04” (1.0)
inch (mm)
Connections ABF TP26MPp00
ABF TE20EPp00 HE 10 20-way B
HE 10 20-way C
Twido side
Input side
Output side
Twido side
Input side
Twido side
Output side
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
– 20 – 12 – 11 – 10 – 9 – 8 – 7 – 6 – 5 – 4 – 3 – 2 – 1
18 – 20 – 17 – 19 – – – 8 – 7 – 6 – 5 – 4 – 3 – 2 – 1 –
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
– – 18 20 16 8 15 7 14 6 13 5 12 4 11 3 10 2 9 1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
18 20 19 17 16 8 15 7 14 6 13 5 12 4 11 3 10 2 9 1
26
HE 10 26-way A
ABF TE20SPp00
HE 10 26-way A
HE 10 20-way B
HE 10 26-way A
HE 10 20-way B
0
Page 27
Connections (continued)
0
Twido programmable controller
0
Discrete I/O modules
Connections (continued) Input modules TWD DDI 8DT (c 24 V)
TWD DAI 8DT (a 120 V)
TWD DDI 16DK (c 24 V)
0
I0
1
I1
2
I2
3
I3
COM1 NC
(1)
a
4
I4
5
I5
(1)
6
I6
(2)
7
I7
(1) (2)
COM0
(2)
v The COM terminals are linked internally TWD DDI 16DT (c 24 V)
v The COM terminals are linked internally TWD DDI 32DK (c 24 V)
(1) (2)
(1)
(1)
(2)
(2)
v The COM terminals are linked internally v The COM0 terminals are linked internally. v The COM1 terminals are linked internally.
(1) (2)
(1) (2)
(1) Source input (negative logic) (2) Sink input (positive logic).
27