The text of a manual · part 3 of 30
Variable speed drives Altivar 61 Catalogue: Characteristics
Pages 10 to 17 of 211, from Variable speed drives Altivar 61 Catalogue
The original document is the PDF (4.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Telemecanique Altivar 61 ATV61, Schneider Altivar 61 ATV61 and Square D Altivar 61 ATV61
Page 10
Characteristics
0
Variable speed drives for asynchronous motors
0
Altivar 61
Environmental characteristics Conformity to standards
EMC immunity
Conducted and radiated EMC em ATV 61H075M3, HU15M3 issions for drives ATV 61H075N4…HU40N4 ATV 61HU22M3…HU75M3 ATV 61HU55N4…HC63N4
ATV 61HpppM3X
ATV 61W075N4…WD90N4 ATV 61W075N4C…WD90N4C e marking Product certifications Degree of protection ATV 61HpppM3 ATV 61HD11M3X…HD45M3X ATV 61H075N4…HD75N4 ATV 61HD55M3X…HD90M3X ATV 61HD90N4…HC31N4 ATV 61HC40N4…HC63N4
Vibration resistance
Shock resistance
Presentation: pages 4 to 7
ATV 61W075N4…WD90N4 ATV 61W075N4C…WD90N4C ATV 61HpppM3 ATV 61HD11M3X…HD45M3X ATV 61H075N4…HD75N4 ATV 61W075N4…WD75N4 ATV 61W075N4C…WD75N4C ATV 61HD55M3X…HD90M3X ATV 61HD90N4…HC63N4 ATV 61WD90N4 ATV 61WD90N4C ATV 61HpppM3 ATV 61HD11M3X…HD45M3X ATV 61H075N4…HD75N4 ATV 61W075N4…WD75N4 ATV 61W075N4C…WD75N4C ATV 61HD55M3X…HD90M3X ATV 61HD90N4…HC16N4 ATV 61WD90N4 ATV 61WD90N4C ATV 61HC22N4…HC63N4
References: pages 18 to 21
Altivar 61 drives have been developed to conform to the strictest international standards and the recommendations relating to electrical industrial control devices (IEC, EN), in particular: low voltage, IEC/EN 61800-5-1, IEC/EN 61800-3 (conducted and radiated EMC immunity and emissions). IEC/EN 61800-3, environments 1 and 2 IEC/EN 61000-4-2 level 3 IEC/EN 61000-4-3 level 3 IEC/EN 61000-4-4 level 4 IEC/EN 61000-4-5 level 3 IEC/EN 61000-4-6 level 3 IEC/EN 61000-4-11 (1) IEC/EN 61800-3, environments 1 and 2, categories C1, C2, C3 EN 55011 class A group 1, IEC/EN 61800-3 category C2 With additional EMC filter (2): b EN 55011 class B group 1, IEC/EN 61800-3 category C1 EN 55011 class A group 2, IEC/EN 61800-3 category C3 With additional EMC filter (2): b EN 55011 class A group 1, IEC/EN 61800-3 category C2 b EN 55011 class B group 1, IEC/EN 61800-3 category C1 With additional EMC filter (2): b EN 55011 class A group 1, IEC/EN 61800-3 category C2 b EN 55011 class B group 1, IEC/EN 61800-3 category C1 EN 55011 class A group 1, IEC/EN 61800-3 category C2 EN 55011 class B group 1, IEC/EN 61800-3 category C1 The drives have e marking in accordance with the European directives on low voltage (73/23/EEC and 93/68/EEC) and EMC (89/336/EEC). UL, CSA, DNV, C-Tick, NOM 117 and GOST IEC/EN 61800-5-1, IEC/EN 60529 IP 21 and IP 41 on upper part IP 20 without blanking plate on upper part of cover IP 21 with accessory VW3 A9 1pp, UL Type 1 with accessory VW3 A9 2pp, see pages 24 and 25 IP 00, IP 41 on the upper part and IP 30 on the front panel and side parts IP 31 with accessory VW3 A9 1pp, UL Type 1 with accessory VW3 A9 2pp, see pages 24 and 25 IP 00, IP 41 on the upper part and IP 30 on the front panel and side parts IP 31 with accessory VW3 A9 1pp, see page 25 UL Type 12/IP 54 1.5 mm peak to peak from 3…13 Hz, 1 gn from 13…200 Hz, conforming to IEC/EN 60068-2-6
1.5 mm peak to peak from 3…10 Hz, 0.6 gn from 10…200 Hz, conforming to IEC/EN 60068-2-6
15 gn for 11 ms conforming to IEC/EN 60068-2-27
7 gn for 11 ms conforming to IEC/EN 60068-2-27
4 gn for 11 ms conforming to IEC/EN 60068-2-27 (1) Drive behaviour according to the drive configurations, see pages 166, 167, 173 and 174. (2) See table on page 74 to check permitted cable lengths.
Dimensions: pages 90 to 111
Schemes: pages 112 to 127
Functions: pages 148 to 175
8 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 11
Characteristics (continued)
0
Variable speed drives for asynchronous motors
0
Altivar 61
Environmental characteristics (continued) Maximum ambient pollution
Environmental conditions
ATV 61HpppM3 ATV 61HD11M3X, HD15M3X ATV 61H075N4…HD18N4 ATV 61W075N4…WD15N4 ATV 61W075N4C…WD15N4C ATV 61HD18M3X…HD90M3X ATV 61HD22N4…HC63N4 ATV 61WD18N4…WD90N4 ATV 61WD18N4C…WD90N4C ATV 61HpppM3, ATV 61HpppM3X, ATV 61ppppN4, ATV 61WpppN4C ATV 61HpppM3S337, ATV 61HD11M3X337…HD45M3X337, ATV 61HD55M3X…HD90M3X, ATV 61H075N4S337… HD75N4S337, ATV 61HD90N4…HC63N4, ATV 61WpppN4337 ATV 61WpppN4C337
Degree 2 conforming to IEC/EN 61800-5-1
Degree 3 conforming to IEC/EN 61800-5-1
IEC 60721-3-3 classes 3C1 and 3S2
IEC 60721-3-3 class 3C2
Relative humidity Ambient temperature Operation around the unit
°C
Storage Maximum operating altitude
°C m
Operating position Maximum permanent angle in relation to the normal vertical mounting position
Presentation: pages 4 to 7
References: pages 18 to 21
5…95% without condensation or dripping water conforming to IEC 60068-2-3 For ATV 61Hppppp drives: - 10…+ 50 without derating, depending on the rating. Up to + 60°C with derating (and with the VW3 A9 4pp control card fan kit, depending on the ratings). For ATV 61Wppppp drives: - 10…+ 40 without derating. See derating curves on pages 138 to 145. - 25…+ 70 1000 without derating 1000…3000 derating the current by 1% per additional 100 m. Limited to 2000 m for the “Corner Grounded” distribution network 10˚ 10˚
Dimensions: pages 90 to 111
Schemes: pages 112 to 127
Functions: pages 148 to 175
9 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 12
Characteristics (continued) Variable speed drives 0 for asynchronous motors
0
Altivar 61
Drive characteristics Output frequency range
Configurable switching frequency
ATV 61HpppM3 ATV 61HD11M3X…HD37M3X ATV 61H075N4…HD37N4 ATV 61HD45M3X…HD90M3X ATV 61HD45N4…HC63N4 ATV 61W075N4…WD90N4 ATV 61W075N4C…WD90N4C ATV 61HpppM3, ATV 61HD11M3X…HD45M3X, ATV 61H075N4…HD75N4 ATV 61HD55M3X
Hz
0.5…1000
Hz
0.5…500 kHz
ATV 61HD75M3X, HD90M3X kHz
ATV 61HD90N4 kHz
ATV 61HC11N4…HC63N4 kHz
Nominal switching frequency: 12 kHz without derating in continuous operation. Adjustable during operation from 1…16 kHz Above 12 kHz, see derating curves on pages 138 and 139. Nominal switching frequency: 2.5 kHz without derating in continuous operation. Adjustable during operation from 2.5…12 kHz Above 2.5 kHz, see derating curves on pages 140 and 141. Nominal switching frequency: 2.5 kHz without derating in continuous operation. Adjustable during operation from 2.5…8 kHz Above 2.5 kHz, see derating curves on pages 140 and 141. Nominal switching frequency: 4 kHz without derating in continuous operation. Adjustable during operation from 2…8 kHz Above 4 kHz, see derating curves on pages 140 and 141. Nominal switching frequency: 2.5 kHz without derating in continuous operation. Adjustable during operation from 2…8 kHz Above 2.5 kHz, see derating curves on pages 140 to 143. Nominal switching frequency: 8 kHz without derating in continuous operation. Adjustable during operation from 2…16 kHz Above 8 kHz, see derating curves on pages 144 and 145. Nominal switching frequency: 4 kHz without derating in continuous operation. Adjustable during operation from 2…16 kHz Above 4 kHz, see derating curves on pages 144 and 145. 1…100 in open loop mode ± 10% of nominal slip, without speed feedback
ATV 61W075N4…WD15N4 ATV 61W075N4C…WD15N4C ATV 61WD18N4…WD90N4 ATV 61WD18N4C…WD90N4C Speed range Speed accuracy
For a torque variation of 0.2 Tn to Tn
Torque accuracy Transient overtorque Braking torque Maximum transient current
Motor control profile
ATV 61HpppM3 ATV 61HpppM3X ATV 61HpppN4 ATV 61WpppN4 ATV 61WpppN4C Asynchronous motor
Synchronous motor Frequency loop Slip compensation
Presentation: pages 4 to 7
References: pages 18 to 21 kHz
± 15% in open loop mode 130% of the nominal motor torque (typical value at ± 10%) for 60 s 30% of the nominal motor torque without braking resistor (typical value) Up to 130 % with braking resistor installed as an option, see page 57 120% of the nominal drive current for 60 s (typical value)
110% of the nominal drive current for 60 s (typical value) Sensorless Flux Vector Control (FVC) (voltage or current vector) Voltage/frequency ratio (2 or 5 points) Energy saving ratio Vector control without speed feedback PI regulator with adjustable structure for a speed response adapted to the machine (accuracy, speed) Automatic whatever the load. Can be suppressed or adjusted Not available in voltage/frequency ratio
Dimensions: pages 90 to 111
Schemes: pages 112 to 127
Functions: pages 148 to 175
10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 13
Characteristics (continued)
0
Variable speed drives for asynchronous motors
0
Altivar 61
Electrical power characteristics Power
Voltage
V
Frequency
Hz
200 - 15%...240 + 10% single phase for ATV 61H075M3...HU75M3 200 - 15%...240 + 10% 3-phase for ATV 61HpppM3 and ATV 61HpppM3X 380 - 15%...480 + 10% 3-phase for ATV 61ppppN4 and ATV 61WpppN4C 50 - 5%...60 + 5%
Signalling
1 red LED: LED lit indicates the presence of drive voltage
Output voltage
Maximum 3-phase voltage equal to line supply voltage
Drive noise level ATV 61H075M3, HU15M3 ATV 61H075N4…HU22N4 ATV 61W075N4…WU30N4 ATV 61W075N4C…WU30N4C ATV 61HU22M3…HU40M3 ATV 61HU30N4, HU40N4 ATV 61WU40N4, WU55N4 ATV 61WU40N4C, WU55N4C ATV 61HU55M3 ATV 61HU55N4, HU75N4 ATV 61WU75N4, WD11N4 ATV 61WU75N4C, WD11N4C ATV 61HU75M3 ATV 61HD11N4 ATV 61WD15N4 ATV 61WD15N4C ATV 61HD11M3X, HD15M3X ATV 61HD15N4, HD18N4 ATV 61WD18N4, WD22N4 ATV 61WD18N4C, WD22N4C ATV 61HD18M3X, HD22M3X ATV 61HD22N4 ATV 61WD30N4 ATV 61WD30N4C ATV 61HD30M3X…HD45M3X, ATV 61HD30N4, HD37N4 ATV 61WD37N4, WD45N4 ATV 61WD37N4C, WD45N4C ATV 61HD45N4…HD75N4 ATV 61WD55N4…WD90N4 ATV 61WD55N4C…WD90N4C ATV 61HD55M3X, HD75M3X ATV 61HD90N4, HC11N4 ATV 61HD90M3X ATV 61HC13N4 ATV 61HC16N4, HC22N4 ATV 61HC25N4, HC31N4 ATV 61HC40N4, HC50N4 ATV 61HC63N4 dBA
Conforming to directive 86-188/EEC 43 dBA
54.5 dBA
55.6 dBA
57.4 dBA
60.2 dBA
59.9 dBA
64 dBA
63.7 dBA
60.5 dBA
69.5 dBA dBA dBA dBA
66 68 70 71 Between power and control (inputs, outputs, power supplies)
References: pages 18 to 21
Dimensions: pages 90 to 111
Electrical isolation
Presentation: pages 4 to 7
Schemes: pages 112 to 127
Functions: pages 148 to 175
11 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 14
Characteristics (continued)
0
Variable speed drives for asynchronous motors
0
Altivar 61
Connection cable characteristics Cable type for
Mounting in an enclosure Mounting in an enclosure with an IP 21 or IP 31 kit Mounting in an enclosure with a UL Type 1 kit
Single-strand IEC cable, ambient temperature 45°C, copper 90°C XLPE/EPR or copper 70°C PVC 3-strand IEC cable, ambient temperature 40°C, copper 70°C PVC 3-strand UL 508 cable except for choke (2-strand UL 508 cable), ambient temperature 40°C, copper 75°C PVC
Connection characteristics (terminals for the power supply, the motor, the DC bus and the braking resistor) Drive terminals Maximum wire size and tightening torque
ATV 61H075M3…HU40M3 ATV 61H075N4…HU40N4 ATV 61HU55M3 ATV 61HU55N4, HU75N4 ATV 61HU75M3 ATV 61HD11N4 ATV 61HD11M3X, HD15M3X ATV 61HD15N4, HD18N4 ATV 61HD18M3X, HD22M3X ATV 61HD22N4 ATV 61HD30N4, HD37N4 ATV 61HD30M3X, ATV 61HD45N4 ATV 61HD37M3X, ATV 61HD55N4 ATV 61HD45M3X, ATV 61HD75N4 ATV 61HD55M3X, HD75M3X ATV 61HD90M3X ATV 61HD90N4, HC11N4 ATV 61HC13N4 ATV 61HC16N4 ATV 61HC22N4 ATV 61HC25N4 ATV 61HC31N4 ATV 61HC40N4
ATV 61HC50N4
ATV 61HC63N4
ATV 61W075N4…WU55N4 ATV 61W075N4C…WU55N4C ATV 61WU75N4, WD11N4 ATV 61WU75N4C, WD11N4C ATV 61WD15N4 ATV 61WD15N4C ATV 61WD18N4, WD22N4 ATV 61WD18N4C, WD22N4C ATV 61WD30N4 ATV 61WD30N4C ATV 61WD37N4, WD45N4 ATV 61WD37N4C, WD45N4C ATV 61WD55N4 ATV 61WD55N4C ATV 61WD75N4 ATV 61WD75N4C ATV 61WD90N4 ATV 61WD90N4C
L1/R, L2/S, L3/T, U/T1, V/T2, W/T3 PC/-, PO, PA/+ 4 mm2, AWG 8 1.4 Nm, 12.3 lb.in 6 mm2, AWG 6 3 Nm, 26.5 lb.in 16 mm2, AWG 4 3 Nm, 26.5 lb.in 35 mm2, AWG 2 5.4 Nm, 47.7 lb.in 50 mm2, AWG 1/0 24 Nm, 212 lb.in 50 mm2, AWG 1/0 24 Nm, 212 lb.in 150 mm2, 300 kcmil 41 Nm, 360 lb.in 150 mm2, 300 kcmil 41 Nm, 360 lb.in 150 mm2, 300 kcmil 41 Nm, 360 lb.in 2 x 100 mm2, 2 x 250 MCM 2 x 100 mm2, 2 x 250 MCM M10, 24 Nm, 212 lb.in M12, 41 Nm, 360 lb.in 2 x 100 mm2, 2 x 250 MCM 2 x 150 mm2, 2 x 250 MCM M10, 24 Nm, 212 lb.in M12, 41 Nm, 360 lb.in 2 x 100 mm2, 2 x 250 MCM 2 x 100 mm2, 2 x 250 MCM M10, 24 Nm, 212 lb.in M12, 41 Nm, 360 lb.in 2 x 100 mm2, 2 x 250 MCM 2 x 150 mm2, 2 x 250 MCM M10, 24 Nm, 212 lb.in M12, 41 Nm, 360 lb.in 2 x 120 mm2, 2 x 250 MCM 2 x 120 mm2, 2 x 250 MCM M10, 24 Nm, 212 lb.in M12, 41 Nm, 360 lb.in 2 x 150 mm2, 2 x 350 MCM 2 x 150 mm2, 2 x 350 MCM M12, 41 Nm, 360 lb.in M12, 41 Nm, 360 lb.in 4 x 185 mm2, 3 x 350 MCM 4 x 185 mm2, 3 x 350 MCM M12, 41 Nm, 360 lb.in M12, 41 Nm, 360 lb.in 4 x 185 mm2, 3 x 350 MCM 4 x 185 mm2, 3 x 350 MCM M12, 41 Nm, 360 lb.in M12, 41 Nm, 360 lb.in 4 x 185 mm2, 4 x 500 MCM 8 x 185 mm2, 4 x 500 MCM M12, 41 Nm, 360 lb.in M12, 41 Nm, 360 lb.in L1/R, L2/S, L3/T 2 x 2 x 185 mm2, 4 x 500 MCM 8 x 185 mm2, 4 x 500 MCM M12, 41 Nm, 360 lb.in M12, 41 Nm, 360 lb.in U/T1, V/T2, W/T3 4 x 185 mm2, 4 x 500 MCM M12, 41 Nm, 360 lb.in L1/R, L2/S, L3/T 2 x 4 x 185 mm2, 5 x 500 MCM 8 x 185 mm2, 5 x 500 MCM M12, 41 Nm, 360 lb.in M12, 41 Nm, 360 lb.in U/T1, V/T2, W/T3 6 x 185 mm2, 5 x 500 MCM M12, 41 Nm, 360 lb.in 4 mm2, AWG 8 1.4 Nm, 12.3 lb.in 6 mm2, AWG 6 3 Nm, 26.5 lb.in 16 mm2, AWG 4 3 Nm, 26.5 lb.in 35 mm2, AWG 2 5.4 Nm, 47.7 lb.in 50 mm2, AWG 1/0 24 Nm, 212 lb.in 50 mm2, AWG 1/0 24 Nm, 212 lb.in 150 mm2, 300 kcmil 41 Nm, 360 lb.in 150 mm2, 300 kcmil 41 Nm, 360 lb.in 150 mm2, 300 kcmil 41 Nm, 360 lb.in
PA, PB
60 mm2 , 250 MCM M8, 12 Nm, 106 lb.in 60 mm2 , 250 MCM M8, 12 Nm, 106 lb.in 60 mm2 , 250 MCM M8, 12 Nm, 106 lb.in 60 mm2 , 250 MCM M8, 12 Nm, 106 lb.in 120 mm2 , 250 MCM M10, 24 Nm, 212 lb.in 120 mm2 , 250 MCM M10, 24 Nm, 212 lb.in – – –
–
–
12 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 15
Characteristics (continued)
0
Variable speed drives for asynchronous motors
0
Altivar 61
Electrical control characteristics Internal supplies available
External + 24 V power supply (1) (not supplied) Analog inputs AI1-/AI1+
AI2
Configurable voltage and current analog outputs
Configurable relay outputs
Other inputs AO1
Other outputs R1A, R1B, R1C
R2A, R2B
Logic inputs LI
Other outputs LI1...LI5
LI6
Positive logic (Source) Negative logic (Sink) Other inputs Safety input
PWR
Maximum I/O wire size and tightening torque
Short-circuit and overload protection: b 1 x 10.5 V c ± 5% supply for the reference potentiometer (1 to 10 kΩ), maximum current 10 mA b 1 x 24 V c supply (min. 21 V, max. 27 V), maximum current 200 mA. 24 V c (min. 19 V, max. 30 V) Power 30 W 1 bipolar differential analog input ± 10 V c (maximum safe voltage 24 V) Max. sampling time: 2 ms ± 0.5 ms Resolution: 11 bits +1 sign bit Accuracy: ± 0.6% for a temperature variation of 60°C Linearity: ± 0.15% of the maximum value 1 software-configurable current or voltage analog input: b voltage analog input 0...10 V c, impedance 30 kΩ (max. safe voltage 24 V) b current analog input X-Y mA by programming X and Y from 0 to 20 mA, with im pedance 242 Ω Max. sampling time: 2 ms ± 0.5 ms Resolution: 11 bits Accuracy: ± 0.6% for a temperature variation of 60°C Linearity: ± 0.15% of the maximum value See option cards 1 analog output configurable for voltage or current: b voltage analog output 0...10 V c, minimum load impedance 470 Ω b current analog output X-Y mA by programming X and Y from 0 to 20 mA, maxim um load impedance 500 Ω Max. sampling time: 2 ms ± 0.5 ms Resolution: 10 bits Accuracy: ± 1% for a temperature variation of 60°C Linearity: ± 0.2% See option cards 1 relay logic output, one “N/C” contact and one “N/O” contact with common point Minimum switching capacity: 3 mA for 24 V c Maximum switching capacity: b on resistive load (cos ϕ = 1): 5 A for 250 V a or 30 V c b on inductive load (cos ϕ = 0.4 and L/R = 7 ms): 2 A for 250 V a or 30 V c Max. response time: 7 ms ± 0.5 ms Electrical service life: 100,000 operations 1 relay logic output, one “N/O” contact Minimum switching capacity: 3 mA for 24 V c Maximum switching capacity: b on resistive load (cos ϕ = 1): 5 A for 250 V a or 30 V c b on inductive load (cos ϕ = 0.4 and L/R = 7 ms): 2 A for 250 V a or 30 V c Max. response time: 7 ms ± 0.5 ms Electrical service life: 100,000 operations See option cards 5 programmable logic inputs, 24 V c , compatible with level 1 PLC, IEC 65A-68 standard Impedance: 3.5 kΩ Maximum voltage: 30 V Max. sampling time: 2 ms ± 0.5 ms Multiple assignment makes it possible to configure several functions on one input (example: LI1 assigned to forward and preset speed 2, LI3 assigned to reverse and preset speed 3) 1 logic input, configurable by a switch as a logic input or as an input for PTC probes Logic input, characteristics identical to inputs LI1...LI5 Input for a maximum of 6 PTC probes mounted in series: b nominal value < 1.5 kΩ b trip resistance 3 kΩ, reset value 1.8 kΩ b short-circuit protection < 50 Ω State 0 if y 5 V or logic input not wired, state 1 if u 11 V State 0 if u 16 V or logic input not wired, state 1 if y 10 V See option cards 1 input for the Power Removal safety function: b Power supply: 24 V c (max. 30 V) b Impedance: 1.5 kΩ b State 0 if < 2 V, state 1 if > 17 V 2.5 mm 2 (AWG 14) 0.6 Nm (1) Please consult our specialist catalogue “Power supplies, splitter blocks and interfaces”.
Presentation: pages 4 to 7
References: pages 18 to 21
Dimensions: pages 90 to 111
Schemes: pages 112 to 127
Functions: pages 148 to 175
13 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 16
Characteristics (continued)
0
Variable speed drives for asynchronous motors
0
Altivar 61
Electrical control characteristics (continued) Acceleration and deceleration ramps
Ramp profiles: b linear, can be adjusted separately from 0.01 to 9000 s b S, U or customized Automatic adaptation of deceleration ramp time if braking capacities exceeded, possible inhibition of this adaptation (use of braking resistor). By DC injection: b by a command on a programmable logic input b automatically as soon as the estimated output frequency drops to < 0.1 Hz, period adjustable from 0 to 60 s or continuous, current adjustable from 0 to 1.2 In (in open loop mode only). Thermal protection: b against overheating b of the power stage Protection against: b short-circuits between motor phases b input phase breaks b overcurrents between output phases and earth b overvoltages on the DC bus b a break on the control circuit b exceeding the limit speed Safety function for: b line supply overvoltage and undervoltage b input phase loss, in 3-phase Thermal protection integrated in drive via continuous calculation of I2t taking speed into account: b The motor thermal state is saved when the drive is powered down. b Function can be modified via operator dialogue terminals, depending on the type of motor (force-cooled or self-cooled). Protection against motor phase breaks Protection with PTC probes Between earth and power terminals: 2830 V c Between control and power terminals: 4230 V c Between earth and power terminals: 3535 V c Between control and power terminals: 5092 V c > 1 MΩ (electrical isolation) 500 V c for 1 minute
Braking to a standstill
Main drive protection and safety features
Motor protection (see page 172)
Dielectric strength
ATV 61pppM3 ATV 61pppM3X ATV 61ppppN4 ATV 61WpppN4C
Insulation resistance to earth Frequency resolution
Display units
Hz
0.1
Analog inputs
Hz
0.024/50 Hz (11 bits)
Operational safety characteristics Protection
Of the machine
Of the system process
Presentation: pages 4 to 7
References: pages 18 to 21
Power Removal (PWR) safety function which forces stopping and/or prevents the m otor from restarting unintentionally, conforming to EN 954-1 category 3 and draft standard IEC/EN 61800-5-2. Power Removal (PWR) safety function which forces stopping and/or prevents the m otor from restarting unintentionally, conforming to IEC/EN 61508 level SIL2 and draft standard IEC/EN 61800-5-2.
Dimensions: pages 90 to 111
Schemes: pages 112 to 127
Functions: pages 148 to 175
14 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 17
Characteristics (continued)
0
Variable speed drives for asynchronous motors
0
Altivar 61
Communication port characteristics Modbus protocol Type of connection Structure
Physical interface Transmission mode Transmission speed
Format
Polarization Address
Services
Functional profiles Messaging
Communication monitoring Diagnostics
Via LED on ATV 61HpppM3, ATV 61HD11M3X…HD45M3X, ATV 61H075N4…HD75N4 With graphic display terminal
Modbus RJ45 terminal port 2-wire RS 485 RTU Configurable via the display terminal or the PowerSuite software workshop: 9600 bps or 19200 bps Fixed = 8 bits, even parity, 1 stop
Modbus RJ45 network port
Configurable via the display terminal or the PowerSuite software workshop: 4800 bps, 9600 bps, 19200 bps or 38.4 Kbps Configurable via the display terminal or the PowerSuite software workshop: - 8 bits, odd parity, 1 stop - 8 bits, even parity, 1 stop - 8 bits, no parity, 1 stop - 8 bits, no parity, 2 stop
No polarization impedances These should be provided by the wiring system (for example, in the master) 1 to 247, configurable via the terminal or the PowerSuite software workshop. 3 addresses can be configured in order to access the data of the drive, the “Controller Inside” programmable card, the multi-pump card and the communication card respectively. These 3 addresses are identical for the terminal and network ports. CiA DSP 402: “Device Profile Drives and Motion Control”. I/O profile Read Holding Registers (03) 63 words maximum Write Single Register (06) Write Multiple Registers (16) 61 words maximum Read/Write Multiple Registers (23) 63/59 words maximum Read Device Identification (43) Diagnostics (08) Can be inhibited. “Time out”, which can be set between 0.1 s and 30 s An activity LED on integrated 7-segment display terminal. One LED for each port.
One activity LED Control word received Reference received For each port: b Number of frames received b Number of incorrect frames.
CANopen protocol Structure
Services
Diagnostics
Connector Network management Transmission speed Address (Node ID) Number of PDOs PDO modes PDO linking PDO mapping Number of SDOs Emergency CANopen application layer Functional profiles Communication monitoring Via LED on ATV 61HpppM3, ATV 61HD11M3X…HD45M3X, ATV 61H075N4…HD75N4 With graphic display terminal and PowerSuite software workshop
2 LEDs: “RUN” and “ERROR” on integrated 7-segment display terminal
References: pages 18 to 21
Dimensions: pages 90 to 111
Description file
Presentation: pages 4 to 7
9-way male SUB-D connector on CANopen adapter. This connects to the RJ45 Modbus network port. Slave 20 Kbps, 50 Kbps, 125 Kbps, 250 Kbps, 500 Kbps or 1 Mbps 1 to 127, configurable via the terminal or the PowerSuite software workshop. 3 receive and 3 transmit (PDO1, PDO2 and PDO3) Event-triggered, Time-triggered, Remotely-requested, Sync (cyclic), Sync (acyclic) Yes Configurable (PDO1 and PDO2) 1 server Yes CiA DS 301, V 4.02 CiA DSP 402: “Device Profile Drives and Motion Control”. I/O profile Node Guarding, Heartbeat
2 LEDs: “RUN” and “ERROR” Control word received Reference received Display of received PDOs Display of transmitted PDOs State of NMT chart Received PDOs counter Transmitted PDOs counter Reception error counter Transmission error counter A single eds file is supplied for the whole range on the CD-ROM containing the documentation or on the website: www.telemecanique.com. It contains the description of the drive parameters.
Schemes: pages 112 to 127
Functions: pages 148 to 175
15 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com