Manual · Schneider
Variable speed drives Altivar 61 Catalogue
Manual211 pagesPDF 4.9 MB
Product catalog for the Altivar 61 variable speed drive for 3-phase asynchronous motors from 0.75 to 630 kW, with options and dimensions.
What this file really is
The old site listed this file as a manual for the Schneider Altivar 61 ATV61, Square D Altivar 61 ATV61 and Telemecanique Altivar 61 ATV61. The file is the Altivar 61 product catalog (selection, options, dimensions and wiring), not a user manual.
Filed under · 3 models
Filed under these models in the old catalog
Summary
What is in it
Schneider Electric catalog for the Altivar 61 variable speed drive, a frequency inverter for 3-phase asynchronous motors designed for pumping, ventilation and air conditioning. It gives the selection guide, characteristics, references by supply voltage, options (graphic display terminal, I/O extension and multi-pump cards, Controller Inside card, communication cards, braking units and resistors, chokes and filters), dimensions, wiring schemes, motor starter combinations, mounting recommendations, functions and communication bus details.
Its parts
- Selection guide
- Presentation
- Characteristics
- Operation
- References
- Options
- Combinations
- Dimensions
- Schemes
- Motor starters
- Mounting recommendations
- Functions
- PowerSuite software workshop
- Communication buses and networks
From the manual
Key facts from this manual
Each line names its page in the PDF.
The September 05 product catalogue for Altivar 61 variable speed drives (ATV 61H and ATV 61W ranges) for 3-phase asynchronous motors from 0.75 to 630 kW; it is a catalogue, not an operating manual. It covers selection, characteristics, drive references for 200-240 V and 380-480 V supplies, options and accessories, dimensions, wiring schemes, functions and communication networks.
- What it is
- Variable speed drive for 3-phase asynchronous motors from 0.75 to 630 kW p. 1
- Supply voltage
- 200 - 15%...240 + 10% single phase (ATV 61H075M3...HU75M3) or 3-phase (ATV 61HpppM3, HpppM3X); 380 - 15%...480 + 10% 3-phase (ATV 61ppppN4, WpppN4C) p. 13
- Ambient temperature
- ATV 61H: -10 to +50 without derating depending on rating, up to +60°C with derating; ATV 61W: -10 to +40 without derating p. 11
- Display
- All drives come with a remote graphic display terminal; some ratings can be ordered without it (add Z) and then have a 7-segment display p. 20, 21
- Braking torque
- 30% of nominal motor torque without braking resistor (typical); up to 130 % with an optional braking resistor p. 12
- Switching frequency
- 380-480 V drives: adjustable 1…16 kHz up to ATV 61HD75N4, 2…8 kHz for ATV 61HD90N4…HC63N4 p. 21
- Graphic terminal
- VW3 A1 101: 8 lines, 240 x 160 pixels, stores 4 configuration files, IP 54, up to 60°C p. 30
- Terminal accessories
- VW3 A1 102 remote mounting kit for an enclosure door; VW3 A1 104 Rppp remote cables with two RJ45 connectors, 1, 3, 5 or 10 m p. 30
- I/O extension card
- Logic I/O card VW3 A3 201: 1 relay output, 4 x 24 V logic inputs, 2 open collector logic outputs, 1 PTC probe input p. 32
- 115 V input adapter
- VW3 A3 101: 7 logic inputs for 115 V signals; state 0 below 20 V, state 1 from 70 V to 132 V p. 24
- Control card fan kit
- VW3 A9 404 to VW3 A9 407, required for ATV 61HD18M3X…HD45M3X and ATV 61HD22N4…HD75N4 to run at 50°C to 60°C p. 24
- Reinforced version
- Add S337 to ATV 61HpppM3 and ATV 61H075N4...HD75N4 references, or 337 to ATV 61HpppM3X p. 20, 21
- DC choke
- Supplied as standard on the largest ratings and needed on a 3-phase supply; add D to the reference to order without, for DC bus connection p. 20, 21
- Altitude
- 1000 without derating; 1000 to 3000 derating the current by 1% per additional 100 m p. 11
What this manual walks you through
- Choosing a drive reference by supply voltage and motor power p. 20, 21
- Ordering variants without the graphic terminal, reinforced, or without DC choke p. 20, 21
- Using the remote graphic display terminal keys and display p. 30
- Mounting the graphic terminal on an enclosure door p. 30
- Connecting 115 V logic signals p. 24
- Running the drive at 50°C to 60°C with the control card fan kit p. 24
- Adding logic or extended I/O extension cards p. 32
- Environmental and EMC conformity p. 10, 11
Good to know
- On a single-phase supply the ATV 61HU40M3, HU55M3 and HU75M3 need a line choke. p. 20
- The ATV 61HD11M3X to HD90M3X drives come without an EMC filter; filters are an option. p. 20
- A reinforced version supplied for particular environmental conditions must come with a remote graphic display terminal. p. 20, 21
- Running continuously above the nominal switching frequency requires derating the drive current. p. 20
- Altitude is limited to 2000 m on a Corner Grounded distribution network. p. 11
Questions this manual answers
What supply voltage does the Altivar 61 use?
200-240 V single or 3-phase for the M3 and M3X models, and 380-480 V 3-phase for the N4 and N4C models. p. 13
How do I order an ATV 61 without the graphic display terminal?
For the ratings that allow it, add a Z to the end of the reference; the drive then has an integrated 7-segment display. p. 20, 21
What is the part number of the Altivar 61 graphic display terminal?
VW3 A1 101. It can be mounted remotely on an enclosure door with the VW3 A1 102 kit and a VW3 A1 104 Rppp cable. p. 30
Can the Altivar 61 accept 115 V logic signals?
Yes, through the VW3 A3 101 adapter, which needs a 115 V external supply (min. 70 V, max. 132 V). p. 24
Can an ATV 61H drive run at 60°C?
Up to +60°C with derating, and with the VW3 A9 4pp control card fan kit depending on the rating. p. 11
Contents
Chapters and sections
Each line opens the PDF at its page.
- Selection guide4
- Presentation6
- Characteristics10
- Operation18
- Altivar 61 Supply voltage 200…240V 50/60 Hz20
- Supply voltage 380…480V 50/60 Hz21
- Option: accessories24
- Adapter for 115 V a logic inputs24
- Kit for flush-mounting in a dust and damp-proof enclosure25
- Kit for UL Type 1 conformity (mounting outside the enclosure)26
- Kits for IP 21 or IP 31 conformity (mounting outside the enclosure)27
- Substitution kit for Altivar 38 drives28
- Remote graphic display terminal30
- I/O extension cards32
- Multi-pump cards34
- “Controller Inside” programmable card38
- Communication buses and networks46
- resistance braking units56
- braking resistors58
- braking units and resistors60
- Characteristics curves for resistors61
- DC chokes64
- Line chokes68
- Passive filters71
- additional EMC input filters76
- Output filters80
- Motor chokes81
- Sinus filters84
- Combinations86
- Dimensions92
29 more lines, from page 113 on
- Sinus filters113
- Safety requirements114
- Schemes114
- Schemes conforming to standards EN 954-1 category 1, IEC/EN 61508 capacity SIL1,in stopping category 0 according to IEC/EN 60204-1116
- Schemes conforming to standards EN 954-1 category 3, IEC/EN 61508 capacity SIL2,in stopping category 0 according to IEC/EN 60204-1118
- Schemes conforming to standards EN 954-1 category 3, IEC/EN 61508 capacity SIL2,in stopping category 1 according to IEC/EN 60204-1119
- Power terminal connectionsFor ATV 61HC50N4 and ATV 61HC63N4120
- VW3 A3 201 and VW3 A3 202 I/O extension cards122
- VW3 A4 6pp passive filters124
- Drives combined with a braking unit and wired onto the same DC bus125
- Connection diagrams for several drives in parallel on the DC bus126
- Size of DC bus fuses (F1, F2, F3, F4) depending on the driverating127
- Installation128
- Electromagnetic compatibility128
- Combinations for customer assembly130
- Mounting and installation recommendations140
- Functions150
- Product reference index208
The whole text · 30 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Contents1-3
- Pages 4 to 94-9
- Characteristics10-17
- Pages 18 to 2018-20
- Supply voltage 380…480V 50/60 Hz21-23
- Option: accessories, pages 24 to 3324-33
- Option: accessories, pages 34 to 4334-43
- Option: accessories, pages 44 to 5344-53
- Option: accessories, pages 54 to 6054-60
- Characteristics curves for resistors61-63
- DC chokes64-67
- Line chokes68-70
- Passive filters71-75
- additional EMC input filters76-79
- Pages 80 to 8380-83
- Pages 84 to 9184-91
- Dimensions, pages 92 to 9992-99
- Dimensions, pages 100 to 107100-107
- Dimensions, pages 108 to 113108-113
- Safety requirements114-127
- Pages 128 to 133128-133
- Pages 134 to 139134-139
- Mounting and installation recommendations140-149
- Functions, pages 150 to 159150-159
- Functions, pages 160 to 169160-169
- Functions, pages 170 to 179170-179
- Functions, pages 180 to 189180-189
- Functions, pages 190 to 199190-199
- Functions, pages 200 to 207200-207
- Product reference index208-211
The file