The text of a manual · part 27 of 30
Variable speed drives Altivar 61 Catalogue: Functions, pages 180 to 189
Pages 180 to 189 of 211, from Variable speed drives Altivar 61 Catalogue
The original document is the PDF (4.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Telemecanique Altivar 61 ATV61, Schneider Altivar 61 ATV61 and Square D Altivar 61 ATV61
Page 180
534513
Presentation, functions
PowerSuite software workshop
0
0
Presentation The PowerSuite software workshop for PC is a user-friendly tool designed for setting up control devices for the following Telemecanique brand motors: b TeSys model U controller-starters b Altistart soft start/soft stop units b Altivar variable speed drives. It includes various functions designed for setup phases such as: b Preparing configurations b Start-up b Maintenance. In order to simplify the start-up and maintenance phases, the PowerSuite software workshop can use the Bluetooth® wireless link.
Functions (1) PowerSuite screen on PC Installed base management
Preparing configurations The PowerSuite software workshop can be used on its own to generate the device configuration. It can be saved, printed and exported to office automation software. The PowerSuite software workshop can also be used to convert: b An Altivar 28 drive configuration to an Altivar 31 drive configuration b An Altivar 38 drive configuration to an Altivar 61 drive configuration b An Altivar 58 or Altivar 58F drive configuration to an Altivar 71 drive configuration. Start-up
533181
When the PC is connected to the device, the PowerSuite software workshop can be used to: b Transfer the generated configuration b Adjust b Monitor. This option has been enhanced with new functions such as: v The oscilloscope v The high speed oscilloscope (minimum time base: 2 ms) v Displaying communication parameters b Control b Save the final configuration. PowerSuite screen on PC View of PI regulator function parameters
Maintenance
533182
In order to simplify maintenance operations, the PowerSuite software workshop can be used to: b Compare the configuration of a device currently being used with a saved configuration b Manage the user’s installed base of equipment, in particular: v Organize the installed base into folders (electrical equipment, machinery, workshops, etc.) v Store maintenance messages v Simplify Ethernet connection by storing the IP address. User interface
PowerSuite screen on PC Monitoring control panel (cursor, gauge)
The PowerSuite software workshop can be used to: b Present the device parameters arranged by function in the form of illustrated views of diagrams or simple tables b Customize the parameter names b Create: v A user menu (choice of particular parameters) v Monitoring control panels with graphic elements (cursors, gauges) b Perform sort operations on the parameters b Display text in five languages (English, French, German, Italian and Spanish). The language changes immediately and there is no need to restart the program. It also has online contextual help: b On the PowerSuite tool b On the device functions by direct access to the user manuals. (1) Some functions are not available for all devices. See the table of function availability, page 179.
References: page 180
178 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 181
Functions (continued)
0
PowerSuite software workshop
0
Function availability for the PowerSuite software workshop Functions not listed in the table are available for all devices. Function available with devices
Controllerstarter TeSys model U
Soft start/soft Drives stop unit ATS 48 ATV 11
ATV 31
ATV 61
ATV 71
Monitoring Oscilloscope High speed oscilloscope Display of communication parameters Control Customization of parameter names Creation of a user menu Creation of monitoring control panels Sort operation on parameters Functions available Functions not available
522793
Connections (1) Modbus communication bus The PowerSuite software workshop can be connected directly to the device terminal port or Modbus network port via the serial port on the PC.
PowerSuite
Two types of connection are possible: b With a single device (point-to-point connection), using a VW3 A8 106 PC serial port connection kit b With a number of devices (multidrop connection), using the XGS Z24 interface.
RS 232 XGS Z24 RS 485
Modbus bus
ATV 31
ATV 61
ATV 71
TeSys model U
ATS 48
Modbus multidrop connection
Ethernet TCP/IP communication network The PowerSuite software workshop can be connected to an Ethernet TCP/IP network (see pages 182 to 187). In this case, the devices can be accessed: b Using a VW3 A58 310 communication card for the Altivar 61and 71 drives b Using a 174 CEV 300 20 Ethernet-Modbus bridge. Bluetooth® wireless link The PowerSuite software workshop can communicate via a Bluetooth® radio link with a device equipped with a Bluetooth® - Modbus VW3 A8 114 adapter. The adapter plugs into the device terminal port or Modbus network port and has a range of 10 m (class 2).
522794
PLC (2)
PowerSuite
If the PC does not have Bluetooth® technology, use the VW3 A8 115 USB-Bluetooth® adapter. Ethernet TCP/IP network
Remote maintenance Using a simple Ethernet connection, the PowerSuite software workshop can be used for remote monitoring and diagnostics. When devices are not connected to the Ethernet network, or it is not directly accessible, various remote transmission solutions may be possible (modem, teleprocessing gateway, etc.). Please consult your Regional Sales Office.
Bridge
Modbus bus
(1) Please refer to the compatibility table on page 181. (2) Please refer to our specialist “Automation platform Modicon Premium and Unity - PL7 software” and “Automation platform Modicon TSX Micro - PL7 software” catalogues. ATV 31
ATS 48
ATV 61
ATV 71
Ethernet connection
Presentation: page 178
References: page 180
179 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 182
References
0
PowerSuite software workshop
0
PowerSuite software workshop 522838
Description
533188
VW3 A8 114
Presentation: page 178
Reference
Weight kg 0.100 b 1 program for PC in English, French, German, Italian VW3 A8 104 and Spanish b Variable speed drive and starter technical manuals. VW3 A8 105 0.100 PowerSuite update b 1 program for PC in English, French, German, Italian CD-ROM (1) and Spanish b Variable speed drive and starter technical manuals. VW3 A8 106 0.350 b 1 x 3 m cable with 2 RJ45 connectors Connection kit for PC serial b 1 RS 232/RS 485 converter with one 9-way female SUB-D port connector and 1 RJ45 connector for point-to-point Modbus b 1 converter for the ATV 11 drive, with one 4-way male connection connector and one RJ45 connector b 1 RJ45/9-way male SUB-D adapter for connecting ATV 38/58/58F drives b 1 RJ45/9-way female SUB-D adapter for connecting ATV 68 drives. RS 232-RS 485 interface 1 multidrop Modbus converter for connection XGS Z24 0.105 for multidrop Modbus connection to screw terminals. Requires a 24 V c (20...30 V), 20 mA power supply (3). Modbus-Bluetooth® VW3 A8 114 0.155 b 1 Bluetooth® adapter (10 m range, class 2) with 1 RJ45 connector adapter (2) b 1 x 0.1 m cable with 2 RJ45 connectors for PowerSuite b 1 x 0.1 m cable with 1 RJ45 connector and 1 mini DIN connector for TwidoSoft b 1 RJ45/9-way male SUB-D adapter for connecting ATV 38/58/58F drives. USB-Bluetooth® adapter VW3 A8 115 0.290 This adapter is required for a PC which is not equipped for PC with Bluetooth® technology. It is connected to a USB port on the PC. Range of 10 m (class 2). (1) Updates a version u V1.50 with the latest available version. For versions < V1.50, you should order the PowerSuite CD-ROM, VW3 A8 104. (2) Can also be used to communicate between a Twido PLC and the TwidoSoft software workshop. (3) Please consult our “Interfaces, I/O splitter boxes and power supplies” catalogue. PowerSuite CD-ROM
VW3 A8 104
Composition
Functions: pages 178 and 179
180 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 183
Compatibility
0
PowerSuite software workshop
0
Compatibility of PowerSuite software workshop with the following devices (1) Connection
Modbus Ethernet (device equipped with an Ethernet TCP/IP card) Ethernet via Modbus Ethernet bridge Bluetooth® Compatible software versions Incompatible software versions
Controllerstarter TeSys model U V1.40
Soft start/ Drives soft stop unit ATS 48 ATV 11
ATV 31
ATV 61
ATV 71
V1.30
V2.0
V2.30 V2.30 V2.30 V2.30
V2.2 V2.2 V2.2 V2.2
V1.50 V2.2
V1.40
V2.0 V2.2
Hardware and software environments The PowerSuite software workshop can operate in the following PC environments and configurations: b Microsoft Windows® 98 SE, Microsoft Windows® 2000, Microsoft Windows® XP b Pentium III, 800 MHz, hard disk with 300 MB available, 128 MB RAM b SVGA or higher definition monitor (1) Software version supplied for the latest version of drive available.
Presentation: page 178
Functions: pages 178 and 179
References: page 180
181 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 184
Presentation
0
Starters, drives and communication
0
Ethernet TCP/IP network Transparent Ready concept
Presentation Introduced by Schneider Electric, the Transparent Ready concept enables transparent communication between control system devices, production and management. Network technologies and the associated new services are used to share and distribute data between sensors, PLCs, workstations and third-party devices in an increasingly efficient manner. Web servers embedded in network components and control system devices can be used to: b Access configuration data transparently b Perform remote diagnostics b Incorporate simple human/machine interface functions. This concept is based on the Ethernet TCP/IP industrial standard which proposes a single network that meets most communication requirements from sensors/actuators through to production management systems. Where a variety of communication systems are usually required, Transparent Ready standard technologies can result in significant cost savings in the areas of definition, installation, maintenance or training. Transparent Ready is based on: b Ethernet TCP/IP-based services meeting control system requirements in terms of functions, performance and quality of services b Products including several ranges of PLC, distributed I/O, industrial terminals, variable speed drives, gateways and an increasing number of partner products b The ConneXium range of cabling accessories: hubs, switches, cables adapted to the environment and to the requirements of industrial conditions.
Network management
Applications
SNMP
Transport
Link
Physical
FDR (Faulty Device Replacement)
DHCP
Web server
TFTP
FTP
UDP
Messaging
HTTP
I/O Scanning
Modbus
TCP
IP
MIB Transparent Ready
Services
Ethernet 2
Services supported by the Altivar 61 and Altivar 71 drives
The Altistart 48 soft start/soft stop unit and the Altivar 31 variable speed drive are connected to the Ethernet TCP/IP network via an Ethernet/Modbus 174 CEV 300 20 Ethernet/Modbus bridge. The Altivar 61 and Altivar 71 variable speed drives are connected to the Ethernet TCP/IP network via a VW3 A3 310 communication card. This card comes with a basic web server, which users can adapt completely according to the application (Java or FactoryCast development tool).
Characteristics: page 183
Functions: pages 183 to 185
Connections: page 186
References: pages 186 and 187
182 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 185
Characteristics, functions
0
Starters, drives and communication
0
Ethernet TCP/IP network Transparent Ready concept
Characteristics Structure
Topology Transmission mode Data rate Medium Length of network
Type of device Type of interface Universal services Transparent Ready services
Industrial local area network conforming to ANSI/IEEE 802.3 (4th edition 1993-07-08) Star network Manchester baseband. Half-duplex or full-duplex 10/100 Mbps with automatic recognition STP double shielded twisted pair, impedance 100 Ω ± 15 Ω for 10 BASE-T or category 5 Ethernet cable, conforming to standard TIA/EIA-568A 100 m maximum between Hub or switch and a station ATS 48, ATV 31 174 CEV 300 20 SNMP Modbus messaging
ATV 61, ATV 71 VW3 A3 310 HTTP, BOOTP, DHCP, FTP, TFTP, SNMP Modbus messaging, IO Scanning, FDR
Universal services HTTP HTTP “Hypertext Transfer Protocol” (RFC 1945) is a protocol used to transmit web pages between a server and a browser. HTTP has been used on the Web since 1990. Web servers embedded in control system devices are at the heart of the Transparent Ready concept and provide easy access to devices anywhere in the world using a standard web browser such as Internet Explorer or Netscape Navigator. BOOTP/DHCP BOOTP/DHCP (RFC 1531) is used to supply devices (client) automatically with IP addresses and parameters. This avoids having to manage the addresses of each device individually by transferring their management to a server. BOOTP identifies the client device by its Ethernet MAC address. This address is unique to each device and should be entered in the server each time the device is changed. DHCP “Dynamic Host Configuration Protocol” identifies the client device by a name in plain language (“Device Name”) which is maintained throughout the application: example: “Conveyor 23”. Altivar 61 and Altivar 71 drives can be given a name (“Device Name”) by the terminal or the PowerSuite software workshop. The FDR (“Faulty Device Replacement”) service uses the standard DHCP and TFTP protocols. FTP/TFTP FTP, “File Transfer Protocol” (RFCs 959, 2228 and 2640) and TFTP, “Trivial File Transfer Protocol” (RFC 1123), are used to exchange files with devices. Transparent Ready devices implements FTP for downloading firmware or custom web pages. The FDR (“Faulty Device Replacement”) service uses the standard DHCP and TFTP protocols. SNMP The Internet community has developed the SNMP standard , “Simple Network Management Protocol” (RFCs 1155, 1156 and 1157), to support the management of the various network components by means of a single system. The network management system can exchange data with SNMP agent devices. This function allows the manager to view the status of the network and devices, to modify their configuration and to return alarms in the event of a fault. Transparent Ready devices are compatible with SNMP and can be integrated naturally into a network administered via SNMP.
Presentation: page 182
Connections: page 186
References: pages 186 and 187
183 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 186
Functions (continued)
0
Starters, drives and communication
0
Ethernet TCP/IP network Transparent Ready concept
Transparent Ready services Modbus communication standard Modbus, the industry communication standard since 1979, has been ported to Ethernet TCP/IP, the backbone of the Internet revolution, to create Modbus TCP/IP, a totally open protocol on Ethernet. There is no need for any proprietary component, nor the purchase of a licence in order to develop a connection to Modbus TCP/IP. This protocol can easily be ported to any device supporting a standard TCP/IP communication stack. The specifications can be obtained free of charge from the website: www.modbus.org. Modbus TCP/IP, simple and open
The Modbus application layer is very simple and universally familiar. Thousands of manufacturers are already implementing this protocol. Many have already developed a Modbus TCP/IP connection and numerous products are currently available. The simplicity of Modbus TCP/IP enables any small field device, such as an I/O module, to communicate on Ethernet without the need for a powerful microprocessor or a large amount of internal memory. Modbus TCP/IP, high performance
Thanks to the simplicity of its protocol and the fast Ethernet throughput data rate of 100 Mbps, the Modbus TCP/IP achieves excellent performance. This means that this type of network can be used in realtime applications such as I/O Scanning. I/O Scanning service Schematic diagram
%MW word table Write Read
Premium
Ethernet TCP/IP
Input words Drive output words Momentum Altivar 61
Altivar 71
Altivar 71
The Altivar 61 and Altivar 71 drives accept the I/O scanning service generated by: b The following automation platforms: v Premium equipped with a TSX ETY 410/5101 module v Quantum v Momentum M1E b A PC equipped with Modbus communication software with the I/O scanner function. This service is used to manage the exchange of remote I/O on the Ethernet network after simple configuration and without the need for special programming. The drive I/O are scanned transparently by means of read/write requests according to the Modbus Master/Slave protocol on the TCP/IP profile. The I/O Scanning service can be configured, activated or deactivated by: b The PowerSuite software workshop b The standard web server.
Presentation: page 182
Characteristics: page 183
Connections: page 186
References: pages 186 and 187
184 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 187
Functions (continued)
0
Starters, drives and communication
0
Ethernet TCP/IP network Transparent Ready concept
Transparent Ready services (continued) Faulty Device Replacement (FDR) service The FDR service uses standard DHCP and TFTP technologies with the aim of simplifying the maintenance of Ethernet devices. It is used to replace a faulty device with a new product, ensuring its detection, reconfiguration and automatic restarting by the system, without the need for any delicate manual intervention. The main steps are: b A device using the FDR service becomes faulty. b A similar device is taken out of the maintenance reserve base, preconfigured with the “Device_name” of the faulty device, then reinstalled on the network. b The FDR server (which can be a Quantum or Premium PLC Ethernet module) detects the new arrival, configures it with its IP address and transfers all its configuration parameters to it. b The substituted device checks that the parameters are fully compatible with its own characteristics, then switches to operational mode.
Web server The Ethernet card in Altivar 61 and Altivar 71 drives incorporates a standard web server, in English. The functions provided by this web server require no special configuration or programming of the PC supporting the web browser. Using a password, two levels of access can be defined to the web server: read-only or modification. The standard web server provides access to the following functions: b Altivar Viewer b Data Editor b Ethernet Statistics b Security b … The standard web server can be adapted or replaced by a customized web server depending on the requirements of the application and downloaded via FTP. Knowledge of the HTTP protocol and Java technology are required to be able to create or modify a web server. Altivar Viewer
Presentation: page 182
Characteristics: page 183
Connections: page 186
References: pages 186 and 187
185 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 188
Connections, references
0
Starters, drives and communication
0
Ethernet TCP/IP network Transparent Ready concept
Connections Redundant fibre optic ring 200 Mbps Full-duplex
Switch
Switch
Premium
Switch Premium
Hub
Transceiver Optical fibre Hub
Quantum Transceiver Fibre optic loop Hub
Hub
ATV 61
Momentum
Hub
Bridge
Bridge
ATV 71
ATV 31
ATS 48
Magelis XBT
Advantys STB
ATV 71
ATS 48
ATV 71
Ethernet network connection elements
522077
Communication interfaces Description
For devices
Reference
Weight kg 0.300
Communication card equipped with an RJ45 connector Ethernet Modbus TCP/IP 10/100 Mbps Class C 20 Ethernet /Modbus bridge with 1 x 10BASE-T/100BASE-TX Ethernet port (RJ45 type)
ATV 61 ATV 71
VW3 A3 310
ATS 48 ATV 31
174 CEV 300 20 (1)
0.500
Length m 2
Reference (2) 490 NTW 000 02
Weight kg –
5
490 NTW 000 05
–
12
490 NTW 000 12
–
40
490 NTW 000 40
–
80
490 NTW 000 80
–
3
VW3 A8 306 D30
–
Connecting cables Description
174 CEV 300 20
Use From Straight shielded twisted pair ATV 61 or cables ATV 71 2 RJ45 connectors (+VW3 A3 310 communication card), Ethernet/ Modbus bridge 174 CEV 300 20
Cable for Modbus bus 1 RJ45 connector and one stripped end
ATS 48, ATV 31
To 499 NpH 1pp 10 hubs, 499 NpS 171 00 switches
Ethernet/ Modbus bridge 174 CEV 300 20
(1) Please consult our specialist “Automation platform Modicon Premium and Unity - PL7 software” catalogue. (2) Cable conforming to category 5 EIA/TIA-568 standard and IEC 1180/EN 50 173, class D. For UL and CSA 22.1 approved cables, add the letter U at the end of the reference. Example: 490 NTW 000 02 becomes 490 NTW 000 02U.
Presentation: page 182
Characteristics: page 183
Functions: pages 183 to 185
186 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 189
References (continued)
0
Starters, drives and communication
0
Ethernet TCP/IP network Transparent Ready concept
Ethernet network connection elements (continued) Hubs 571200~1
Description
Number of ports Copper Optical cable fibre 4 –
499 NEH 104 10
0.530
4
–
499 NEH 141 00
0.240
3 Hub - 10Mbps twisted pair and multimode fibre opticoptical fibre 10BASE-T ports for copper cable, shielded RJ45 connectors 10BASE-FL ports for optical fibre, ST connectors (BFOC)
2
499 NOH 105 10
0.900
Hub - 10 Mbps twisted pair 10BASE-T ports for copper cable, shielded RJ45 connectors Hub - 100 Mbps twisted pair 100BASE-T ports for copper cable, shielded RJ45 connectors
Reference
Weight kg
571385~1
499 NEH 141 00
Switches Description
Number of ports Copper Optical cable fibre 5 –
Configurable
Reference no
499 NES 251 00
0.190
8
– no
499 NES 181 00
0.230
7
– yes
499 NES 271 00
0.460
4
1 no
499 NMS 251 01
0.330
3
2 no
499 NMS 251 02
0.335
5
2 yes
499 NOS 271 00
0.460
Switches, twisted pair and single-mode fibre opticoptical 4 fibre 10BASE-T/100BASE-TX ports, 3 for copper cable, shielded RJ45 connectors 100BASE-FX ports, 5 for optical fibre, SC connectors
1 no
499 NSS 251 01
0.330
2 no
499 NSS 251 02
0.335
2 yes
499 NSS 271 00
0.460
Optimized switch, twisted pair 10BASE-T/100BASE-TX copper ports, for copper cable, shielded RJ45 connectors 499 NES 251 00
Switches, twisted pair 10BASE-T/100BASE-TX ports, for copper cable, shielded RJ45 connectors
571829~1
Switches, twisted pair and multimode fibre opticoptical fibre 10BASE-T/100BASE-TX ports, for copper cable, shielded RJ45 connectors 100BASE-FX ports, for optical fibre, SC connectors
499 NMS 251 02
Weight kg
(1) For Transparent Ready accessories, please consult our “Ethernet TCP/IP, Transparent Ready” catalogue.
Presentation: page 182
Characteristics: page 183
Functions: pages 183 to 185
Connections: page 186
187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com