Variable speed drives Altivar 61 Catalogue: Functions, pages 190 to 199

Pages 190 to 199 of 211, from Variable speed drives Altivar 61 Catalogue

The original document is the PDF (4.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Telemecanique Altivar 61 ATV61, Schneider Altivar 61 ATV61 and Square D Altivar 61 ATV61

Page 190

Presentation

0

Starters, drives and communication

0

Communication via Fipio bus

Presentation Premium

Magelis XBT

Fipio bus

LUF P1

Advantys STB ATV 71

ATV 61

ATV 31 ATS 48

The Fipio fieldbus is a standard means of communication between control system components and conforms to the World FIP standard. A Premium PLC (bus manager) can control 127 devices (agents) over a maximum distance of 15 km. The Fipio bus manager is integrated in the PLC processor. The Altistart 48 soft start/soft stop unit and the Altivar 31 variable speed drive can be connected to the Fipio bus via an LUF P1 Fipio/Modbus gateway. The Altivar 61 and Altivar 71 variable speed drives can be connected to the Fipio network via a communication card VW3 A3 A311. The following devices can also be connected to the Fipio bus: b TSX Micro (2) or Premium Agent function (1) PLCs b The CCX 17 operator panel (2) b The Magelis XBT-F terminal with graphic screen (3) b The Magelis iPC industrial PC (3) b Advantys STB IP 20 distributed I/O (4) b Discrete, analog or application-specific Momentum distributed I/O (5) b Discrete or analog (IP 20) TBX distributed I/O (1) b TBX discrete (IP 65) or TSX EpF (IP67) dust and damp proof distributed I/O (1) b The TBX SAP 10 Fipio/AS-Interface gateway (1) b The LUF P1 Fipio/Modbus gateway b A PC terminal b Partner products in the Collaborative Automation programme. (1) Please consult our specialist “Automation platform Modicon Premium and Unity - PL7 software” catalogue. (2) Please consult our specialist “Automation platform Modicon TSX Micro and PL7 software” catalogue. (3) Please consult our specialist “Human-Machine interfaces” catalogue. (4) Please consult our specialist “Distributed I/O Advantys STB” catalogue. (5) Please consult our specialist “Modicon Momentum Automation platform” catalogue.

Characteristics: page 189

Connections: page 190

References: pages 190 and 191

188 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 191

Characteristics

0

Starters, drives and communication

0

Communication via Fipio bus

Characteristics Structure

Topology

Industrial bus conforming to the World FIP standard Subscribers linked via daisy-chain or tap junctions

Access method

Producer/consumer principle Bus management by a fixed arbitrator (bus manager)

Transmission mode

Baseband physical layer on shielded twisted pair, according to standard NF C 46-604

Data rate

1 Mbps

Medium

Shielded twisted pair 150 Ω. Optical fibre 62.5/125 with the use of electrical/fibre optic repeaters

Number of subscribers

32 maximum per segment 1 manager + 127 agents maximum over all segments The number of Fipio agents is limited by the memory capacity of Premium processors (62 Altivar drives maximum) (1)

Number of segments

Unlimited in tree or star architectures Limited to 5 cascaded segments The link between 2 subscribers may cross 4 electrical or electrical/fibre optic repeaters maximum

Length of bus

15,000 m maximum 1,000 m maximum without repeater for an electrical segment 5,000 m maximum for 5 electrical segments 3,000 m maximum for 1 fibre optic segment

Type of device Type of interface Profile

ATS 48, ATV 31 LUF P1 FED C 32P

Control and adjustment Monitoring Configuration and adjustment

26 configurable words 8 configurable words (communication scanner) 26 configurable words 8 configurable words (communication scanner) 1 indexed word Read/write access to all functions by the PLC application program (1) Please consult our specialist “Automation platform Modicon Premium and Unity - PL7 software” catalogue.

Presentation: page 188

Connections: page 190

ATV 61, ATV 71 VW3 A3 311 FED C 32

References: pages 190 and 191

189 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 192

Connections, references

0

Starters, drives and communication

0

Communication via Fipio bus

Fipio wiring system 5

Premium

3

5 c 19…60 V

ATV 61

ATV 71

1

7

1

10

2

ATV 71

1

3 12

13 3 c 19…60 V

3 5

11

7

6

5

3 5

5

8 13

10

10

10

4

10

10 c 24…48 V

9 13

ATV 31

ATS 48

Elements for connecting the Fipio bus and a Premium PLC (1) Cards and gateway Description

Code

Reference

Weight kg 0.300

533148

1 VW3 A3 311 Standard Fipio card The card is equipped with a 9-way male SUB-D connector, which can take a TSX FP ACC12 connector with a TSX FP CAp00 trunk cable or TSX FP CCp00 drop cable. This card should be used for new installations. It is also used to replace an ATV 58 or ATV 58F equipped with a VW3 A58311 card by an ATV 71. Substitution Fipio card ATV 71 1 VW3 A3 301 0.300 The card is equipped with a 9-way male SUB-D connector, which can take a TSX FP ACC12 connector with a TSX FP CAp00 trunk cable or TSX FP CCp00 drop cable. This Fipio communication card is reserved for replacing an ATV 58 or ATV 58F equipped with a VW3 A58301 card by an ATV 71. Fipio/Modbus gateway ATS 48 2 LUF P1 0.240 The gateway is equipped with: ATV 31 b 1 Fipio 9-way male SUB-D connector which will take a TSX FP ACC12 connector for use with a TSX FP CAp00 trunk cable or TSX FPCCp00 drop cable b 1 RJ45 connector for Modbus for connection with the VW3 A8 306 Rpp cable Fit an external 24 V c power supply, 100 mA minimum, to be ordered separately (2). (1) To order other elements for connection to the Fipio bus, please consult our specialist “Automation platform Modicon Premium and Unity - PL7 software” catalogue. (2) Please consult our specialist “Interfaces, I/O splitter boxes and power supplies” catalogue.

LUF P1

Presentation: page 188

Used for ATV 61 ATV 71

Characteristics: page 189

190 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 193

References (continued)

0

Starters, drives and communication

0

Communication via Fipio bus

Elements for connecting the Fipio bus and a Premium PLC (continued) (1) Accessories Description

Use

Code

Female connector for device with 9-way Connection via daisy-chain or tap junctions. 3 female SUB-D connector For ATV 61, ATV 71, LUF P1 gateway (polycarbonate, IP 20) and Premium PLC Tap junction Trunk cable tap link 4 (polycarbonate, IP 20) Fipio line terminators Connector, tap junction and repeater 5 (sold in lots of 2) Electrical repeater Increases the length of the bus while 6 (IP 65) enabling connection of 2 segments of Power supply 24…48 V c, 150 mA (2) 1000 m maximum Electrical/fibre optic repeater Used for connection 7 (IP 65) (via a patch panel) of an electrical segment Power supply 19…60 Vc, 210 mA (2) (1000 m max.) and a fibre optic segment (3000 m max.) Modbus splitter block Used to connect an ATV 31, ATS 48 on the 8 equipped with 10 RJ45 connectors LUP P1 gateway and 1 screw terminal Modbus line terminators (3) LU9 GC3 Modbus splitter block 9 FIP wiring test tool Used to test each section of a network – segment

Unit reference TSX FP ACC12

Weight kg 0.040

TSX FP ACC14

0.120

TSX FP ACC7

0.020

TSX FP ACC6

0.520

TSX FP ACC8M

0.620

LU9 GC3

0.500

VW3 A8 306 RC TSX FP ACC9

0.010 0.050

Connecting cables (1) Description Trunk cables 8 mm, 1 shielded twisted pair 150 Ω. In standard atmosphere (4) and inside buildings

Trunk cables 9.5 mm, 1 shielded twisted pair 150 Ω. In harsh environments (5), outside buildings or in mobile installations (6) Drop cables 8 mm, 2 shielded twisted pairs 150 Ω. In standard atmosphere (4) and inside buildings Fibre optic jumper Double optical fibre 62.5/125 Cables for Modbus bus 2 RJ45 connectors

Used From To TSX FP ACC12 TSX FP ACC12 connector, connector, TSX FP ACC14 TSX FP ACC14 junction box, junction box, TSX FP ACC6, TSX FP ACC6 ACC8M repeaters repeater TSX FP ACC12 TSX FP ACC12 connector, connector, TSX FP ACC14 TSX FP ACC14 junction box, junction box, TSX FP ACC6, TSX FP ACC6 ACC8M repeaters repeater TSX FP ACC12 TSX FP ACC14 connector junction box

Code

Length m 100 200 500

Reference TSX FP CA100 TSX FP CA200 TSX FP CA500

Weight kg 5.680 10.920 30.000

10

100 200 500

TSX FP CR100 TSX FP CR200 TSX FP CR500

7.680 14.920 40.000

11

100 200 500

TSX FP CC100 TSX FP CC200 TSX FP CC500

5.680 10.920 30.000

2

TSX FP JF020

0.550

0.3 1 3

VW3 A8 306 R03 VW3 A8 306 R10 VW3 A8 306 R30

0.025 0.060 0.130

10

TSX FP ACC8M Patch panel 12 repeater LUF P1 gateway, LU9 GC3 13 ATS 48, Modbus splitter ATV 31 block

Documentation The manuals and quick reference guides for starters and variable speed drives, as well as the user manuals for communication gateways, are available on the web site: www.telemecanique.com. (1) To order other elements for connection to the Fipio bus, please consult our specialist “Automation platform Modicon Premium and Unity - PL7 software” catalogue. (2) Please consult our specialist “Interfaces, I/O splitter boxes and power supplies” catalogue. (3) Sold in lots of 2. (4) Standard environment: - no particular environmental constraints - operating temperature between + 5 °C and + 60 °C - fixed installation (5) Harsh environment: - withstand to hydrocarbons, industrial oils, detergents, solder splashes - relative humidity up to 100% - saline atmosphere - significant temperature variations - operating temperature between - 10 °C and + 70 °C (6) Mobile installation: cables in accordance with VDE 472 part 603/H: - use on a cable-carrier chain with bending radius 75 mm minimum - use on a gantry, provided that operating conditions such as acceleration, speed, length, etc are adhered to: please consult your Regional Sales Office - unauthorised use on robots, or multi-axis applications.

Presentation: page 188

Characteristics: page 189

Connections: page 190

191 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 194

Presentation, characteristics

0

Starters, drives and communication

0

Communication via Modbus bus

Presentation Quantum Premium TSX Micro

Twido

Modbus bus

ATV 31 ATV 71

ATV 61 ATS 48

Modbus is a master/slave protocol. Two exchange mechanisms are possible: b Request/response: The request from the master is addressed to a given slave. The master then waits for the response from the slave which has been interrogated. b Broadcasting: The master broadcasts a request to all the slave stations on the bus, which execute the command without transmitting a response. The Altistart 48 soft start/soft stop unit and the Altivar 31, Altivar 61 and Altivar 71 variable speed drives have the Modbus protocol integrated as standard. The Altistart 48 soft start/soft stop unit and the Altivar 31 drive are connected to the Modbus bus via their terminal port. The Altivar 61 and Altivar 71 variable speed drives have 2 integrated communication ports: b A terminal port for connecting the graphic display terminal or an industrial HMI terminal (Magelis type) b A Modbus network port. As an option, they can also be equipped with a VW3 A3 303 Modbus/Uni-Telway communication card which offers additional characteristics (4-wire RS 485, ASCII mode, etc.).

Characteristics Type of device Type of connection Structure

Connector Topology Physical interface Access method Transmission mode Data rate 38.4 Kbps 19.2 or 9.6 Kbps 4.8 Kbps Medium Number of subscribers Type of polarization

Length of bus Tap link

Connections: pages 193 and 194

ATS 48 ATV 31 ATV 61, ATV 71 Terminal port Network port Communication card RJ45 RJ45 RJ45 RJ45 9-way female SUB-D Bus 2-wire RS 485 2-wire or 4-wire RS 485 Master/slave RTU RTU or ASCII – – – p – p p p p p p p – p p Double shielded twisted pair 18, 27 or 31 slaves, depending on polarization (1) 4.7 kΩ No pulldown No pulldown No pulldown Configurable. pulldown No pulldown or 4.7 kΩ resistors pulldown resistors 1000 or 1300 m excluding tap links, depending on polarization (1) 3 or 20 m maximum, depending on polarization (1) (1) See the configuration table on page 193.

References: pages 193 to 195

192 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 195

Connections, references

0

Starters, drives and communication

0

Communication via Modbus bus

Configuration on the basis of polarization The specification of the physical layer provided by standard RS 485 is incomplete. Various polarization diagrams can therefore be applied depending on the environment in which the equipment is to be used. The Modbus standard specifies the polarization exactly (1).

Slave

Without polarization

With polarization 4.7 kΩ

Master With polarization 4.7 kΩ Configuration not recommended.

Uni-Telway type configuration 27 slaves. Length of bus: 1,000 m Tap link: 20 m maximum. RC line terminators (R =120 Ω, C = 1 nF).

With polarization 470 Ω Modbus type configuration 31 slaves. Length of bus: 1,300 m Tap link: 3 m maximum. RC line terminators (R =120 Ω, C = 1 nF). Mixed configuration 18 slaves. Length of bus: 1,000 m Tap link: 20 m maximum. RC line terminators (R =120 Ω, C = 1 nF).

Connection elements for RJ45 wiring system PLC

Card

(2)

1

4

3 4

2 4 23 2

4

Description

Used with

Reference

Communication card equipped with a 9-way female SUB-D connector

ATV 61, ATV 71

VW3 A3 303

Weight kg 0.300

Weight kg 0.500

Accessories Description

Code

Modbus splitter block 10 RJ45 connectors and 1 screw terminal block

1

Unit reference LU9 GC3

2

VW3 A8 306 TF03

–

2

VW3 A8 306 TF10

–

3

VW3 A8 306 RC

0.200

3

VW3 A8 306 R

0.010

2

Modbus T-junction boxes

5

522184

Starters/drives

With integrated cable (0.3 m) With integrated cable (1 m) R = 120 Ω, C = 1 nF R = 150 Ω

Line terminators for RJ45 connector (3)

Cables Description Cables for Modbus bus 2 RJ45 connectors

LU9 GC3

532174

Cables for Modbus bus One 9-way male SUB-D connector 1 RJ45 connector Double shielded twisted pair cables VW3 A8 306 TF pp

Use Code From To LU9 GC3 Modbus 4 ATS 48, splitter block ATV 31, ATV 61, ATV 71 (terminal or Modbus network ports) VW3 A8 306 TFpp Modbus T-junction box LU9 GC3 Modbus splitter block ATV 61, ATV 71 (+ VW3 A3 303 communication card)

VW3 A8 306 TFpp Modbus T-junction box LU9 GC3 Modbus splitter block LU9 GC3 Modbus 4 splitter block

LU9 GC3 Modbus splitter block (screw terminals)

LU9 GC3 Modbus 5 splitter block (screw terminals)

Length m 0.3

Reference VW3 A8 306 R03

Weight kg 0.025

1

VW3 A8 306 R10

0.060

3

VW3 A8 306 R30

0.130

1

VW3 A58 306 R10

0.080

3

VW3 A58 306 R30

0.150

100

TSX CSA 100

5.680

200

TSX CSA 200

10.920

500

TSX CSA 500

30.000

(1) Standard defined in 2002, available on the website: www.modbus.org. (2) The cable for connecting the PLC and the splitter block depends on the type of PLC; please consult our “Automation platform Modicon Premium and Unity - PL7 software”, “Automation platform Modicon Quantum”, “Automation platform Modicon TSX Micro and PL7 software” and “Automation and relay functions” catalogues. (3) Sold in lots of 2.

Presentation: page 192

Characteristics: page 192

193 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 196

Connections, references (continued)

0

Starters, drives and communication

0

Communication via Modbus bus

PLC

Connection elements using tap junctions Accessories

(1)

2

3

5

1

4

Description

Code

Reference

Tap junction 3 screw terminals, RC line terminator

1

TSX SCA 50

Weight kg 0.520

Subscriber socket Two 15-way female SUB-D connectors and 2 screw terminals, RC line terminator

2

TSX SCA 62

0.570

Length m 100

Reference TSX CSA 100

Weight kg 5.680

200

TSX CSA 200

10.920

500

TSX CSA 500

30.000

4

3

VW3 A8 306 D30

0.150

5

3

VW3 A8 306

0.150

5

3

VW3 A8 306 2

0.150

Cables Description Starters/drives 533178

Double shielded twisted pair cables

Cable for Modbus bus 1 RJ45 connector and one stripped end

533179

TSX SCA 50

TSX SCA 62

Cable for Modbus bus 1 RJ45 connector and one 15-way male SUB-D connector Cable for Uni-Telway and Modbus bus 2 male SUB-D connectors, 9 and 15-way

Use From TSX SCA 50 tap junction, TSX SCA 62 subscriber socket

Code To TSX SCA 50 tap junction, TSX SCA 62 subscriber socket

TSX SCA 50 tap ATS 48, junction ATV 31, ATV 61, ATV 71 (terminal or Modbus network ports) TSX SCA 62 ATS 48, subscriber socket ATV 31, ATV 61, ATV 71 (terminal or Modbus network ports) TSX SCA 62 ATV 61, ATV 71 subscriber socket (+ VW3 A3 303 communication card)

3

(1) The cable for connecting the PLC and the splitter block depends on the type of PLC; please consult our “Automation platform Modicon Premium and Unity - PL7 software”, “Automation platform Modicon Quantum”, “Automation platform Modicon TSX Micro and PL7 software” and “Automation and relay functions” catalogues.

Presentation: page 192

Characteristics: page 192

194 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 197

References (continued)

0

Starters, drives and communication

0

Communication via Modbus bus

Connection elements using screw terminals Accessories Description R = 120 Ω, C = 1 nF

Line terminators for screw terminals

R = 150 Ω

Sold in lots of 2

Unit reference VW3 A8 306 DRC

Weight kg 0.200

2

VW3 A8 306 DR

0.200

Length m 3

Reference

Cable Description Cable for Modbus 1 RJ45 connector and one stripped end

Use From ATS 48, ATV 31, ATV 61, ATV 71 (terminal or Modbus network ports)

To Standard screw terminal, TSX SCA 50 tap junction

VW3 A8 306 D30

Weight kg 0.150

Documentation The manuals and quick reference guides for starters and variable speed drives, as well as the user manuals for communication gateways, are available on the website: www.telemecanique.com.

Presentation: page 192

Characteristics: page 192

Connections: pages 193 and 194

195 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 198

Presentation

0

Starters, drives and communication

0

Communication via Modbus Plus network

Presentation Quantum

Premium

Modbus Plus network

Gateway

Advantys STB ATV 71

ATV 61

ATV 31 ATS 48

The Modbus Plus network is a high-performance industrial local area network which can be used to meet the needs of client/server type extended architectures, combining a high data rate (1 Mbps), simple low-cost transmission media and numerous messaging services. The Altistart 48 soft start/soft stop unit and the Altivar 31 variable speed drive can be connected to the Modbus Plus network via an NW BM85000 gateway which has four RS 232 serial ports. The Altivar 61 and Altivar 71 variable speed drives can be connected to the Modbus Plus network via a communication card VW3 A3 302 Communication services The main data exchange services between subscribers connected to the network are: b The “Modbus messaging” service according to Modbus protocol b The “Global Data” service: each subscriber makes available 32 words for each of the 63 other network subscribers b The “Peer Cop” dialogue service: point-to-point transaction of 32 receive or transmit words The “Global Data” and “Peer Cop” services are restricted to a Modbus Plus network with a maximum of 64 subscribers. Altivar 61 and Altivar 71 drives are accessed by simple configuration in the PLC using “Peer Cop” and “Global Data” services. These services enable rapid exchange of the main drive parameters: b The “Peer Cop” service for controlling and adjusting the drive b The “Global data” service for monitoring the drive Other parameters, which are used less frequently, can be accessed by the Modbus messaging service.

Characteristics: page 197

Connections: page 198

References: pages 198 and 199

196 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 199

Characteristics

0

Starters, drives and communication

0

Communication via Modbus Plus network

Characteristics Structure

Services

Topology

Bus

Physical interface

RS 485

Access method

Token bus

Transmission mode

HDLC synchronous

Data rate

1 Mbps

Medium

Shielded twisted pair 120 Ω Optical fibre

Number of subscribers per network

32, without repeater 64, with one or more repeaters

Number of networks

4, separated by a maximum of 3 bridges

Length of network

450 m maximum without repeater 1800 m maximum with 3 electrical repeaters 3000 m between 2 fibre optic repeaters

Modbus messaging

Point-to-point requests with confirmation report: 200 bytes maximum, compatible with all Modbus subscribers

“Global Data”

4096-byte shared database Cyclic exchange of 32 broadcast words Limited to one network This service does not cross bridges

“Peer Cop” dialogue

Point-to-point or broadcast message Limited to one network This service does not cross bridges

Type of device Type of interface Control

ATS 48, ATV 31 NW BM85000 “Modbus messaging”

Monitoring

“Modbus messaging”

Configuration and adjustment

“Modbus messaging”

Presentation: page 196

Connections: page 198

ATV 61, ATV 71 VW3 A3 302 “Peer Cop” 8 configurable words maximum (communication scanner) “Global Data” 8 configurable words maximum (communication scanner) “Modbus messaging” Read/write access to all drive parameters

References: pages 198 and 199

197 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com