The text of a manual · part 9 of 30
Variable speed drives Altivar 61 Catalogue: Option: accessories, pages 54 to 60
Pages 54 to 60 of 211, from Variable speed drives Altivar 61 Catalogue
The original document is the PDF (4.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Telemecanique Altivar 61 ATV61, Schneider Altivar 61 ATV61 and Square D Altivar 61 ATV61
Page 54
References
0
Variable speed drives for asynchronous motors
0
Altivar 61 Communication buses and networks
533192
Communication cards (1) (2) Description
Use
Reference
Ethernet (3)
To be connected on a Hub or Switch using a 490 NTW 000 pp cable. See pages 186 and 187
VW3 A3 310
Weight kg 0.300
Modbus/ Uni-Telway
To be connected on TSX SCA 62 subscriber socket using the VW3 A8 306 2 cable. See pages 194 and 201
VW3 A3 303
0.300
Fipio
To be connected using a TSX FP ACC 12 connector with a TSX FP CCpp extension cable or a TSX FP CApp drop cable. See pages 190 and 191
VW3 A3 311
0.300
Modbus Plus
To be connected to the 990 NAD 230 00 IP 20 Modbus Plus tap using a 990 NAD 219p0 cable. See pages 198 and 199
VW3 A3 302
0.300
Profibus DP
To be connected using a 490 NAD 911pp connector to Profibus cable TSX PBS CAp00 (4)
VW3 A3 307
0.300
DeviceNet
The card is equipped with a removable 5-way screw terminal block.
VW3 A3 309
0.300
INTERBUS
To be connected using the 170 MCI ppp00 (4)cable
VW3 A3 304
0.300
LONWORKS
The card is equipped with a removable 3-way screw terminal block.
VW3 A3 312
0.300
METASYS N2 The card is equipped with a 9-way male SUB-D connector
VW3 A3 313
0.300
APOGEE FLN The card is equipped with a 9-way male SUB-D connector
VW3 A3 314
0.300
BACnet
VW3 A3 315
0.300
533193
VW3 A3 311
522856
TSX FP ACC12
The card is equipped with a 9-way male SUB-D connector
490 NAD 911 03
(1) The Altivar 61 drive can only take one communication card. Consult the tables summarizing the possible combinations: drives, options and accessories (see pages 84 to 89). (2) The user manuals are supplied on CD-ROM or can be downloaded from the Internet at "www.telemecanique.com". For Profibus DP, DeviceNet and LONWORKS cards, the description files in gsd, eds or xif format are also supplied on CD-ROM or can be downloaded from the Internet at "www.telemecanique.com". (3) Please consult our “Ethernet TCP/IP Transparent Ready” catalogue. (4) Please consult our specialist “Automation platform Modicon Premium and Unity - PL7 software” catalogue.
Presentation: page 44
Functions: page 45
Characteristics: pages 46 to 51
52 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 55
References (continued)
0
Variable speed drives for asynchronous motors
0
Altivar 61 Communication buses and networks
Connection accessories Description Premium (1)
Length m
Unit reference
Weight kg
–
LU9 GC3
0.500
0.3
VW3 A8 306 R03
0.025
1
VW3 A8 306 R10
0.060
3
VW3 A8 306 R30
0.130
0.3
VW3 A8 306 TF03
–
1
VW3 A8 306 TF10
–
534577
Modbus bus
1
Modbus bus
No.
2
3
2
3 4
Modbus splitter block 1 10 RJ45 connectors and 1 screw terminal block Cables for Modbus bus equipped 2 with 2 RJ45 connectors
4 2
(2)
2
3
3 Modbus T-junction boxes (with integrated cable)
ATV 61
3
Line terminator For RJ45 connector (3)
4
–
VW3 A8 306 RC
0.010
Description
No.
Length m
Reference
CANopen adapter for mounting on 1 the RJ45 socket in the drive control terminals. The adapter provides a 9-way male SUB-D connector conforming to the CANopen standard (CIA DRP 303-1).
–
VW3 CAN A71
–
CANopen connector (4) 9-way female SUB-D connector with line terminator (can be disabled) Output at 180° for 2 CANopen cables. CAN-H, CAN-L, CAN-GND connection
2
–
VW3 CAN KCDF 180T
–
CANopen cables (1) Standard cable. Low smoke emission, halogen-free. Flame retardant (IEC 60332-1).
3
50
TSX CAN CA 50
–
100
TSX CAN CA 100
–
300
TSX CAN CA 300
–
CANopen cables (1) UL certification. Flame retardant (IEC 60332-2).
3
50
TSX CAN CB 50
–
100
TSX CAN CB 100
–
300
TSX CAN CB 300
–
50
TSX CAN CD 50
–
100
TSX CAN CD 100
–
300
TSX CAN CD 300
–
Example of Modbus diagram, connections via splitter blocks and RJ45 connectors Premium (1)
Weight kg
533196
CANopen bus
CANopen bus
(2) ATV 61
1 2 3
533196
Example of CANopen diagram
VW3 CAN A71
522855
3 CANopen cables (1) Cable for harsh environments (5) or mobile installation. Low smoke emission, halogen-free. Flame retardant (IEC 60332-1). VW3 CAN KCDF 180 T
Presentation: page 44
(1) Please consult our specialist “Automation platform Modicon Premium and Unity - PL7 software” and “Automation platform Modicon TSX Micro and PL7 software” catalogues. (2) Cable depending on the type of controller or PLC. (3) Sold in lots of 2. (4) For ATV 61HpppM3, ATV 61HD11M3X, HD15M3X, ATV 61H075N4 ... HD18N4 drives, this connector can be replaced by the TSX CAN KCDF 180T connector. (5) Harsh environments: - Resistance to hydrocarbons, industrial oils, detergents and solder splashes - Relative humidity up to 100% - Saline atmosphere - Significant temperature variations - Operating temperature between -10°C and +70°C
Functions: pages 45
Characteristics: pages 46 to 51
53 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 56
Presentation, characteristics
0
Variable speed drives for asynchronous motors
0
Altivar 61 Option: resistance braking units
Presentation Resistance braking enables the Altivar 61 drive to operate while braking to a standstill or during "generator" operation, by dissipating the energy in the braking resistor.
L1 L2
M1 3
ATV 61HC25N4pppHC63N4 L3
Braking unit
Braking resistor
The ATV 61HpppM3, ATV 61HpppM3X, ATV 61H075N4…HC22N4, ATV 61WpppN4 and ATV 61WpppN4C drives have a built-in dynamic brake transistor. For ATV 61HC25N4…HC63N4 drives, a braking unit must be used. It is controlled by the drive: b For ATV 61HC25N4 and ATV 61HC31N4 drives, the braking unit is mounted directly on the left-hand side of the drive, see dimensions on page 91 b For ATV 61HC40N4...HC63N4 drives, the braking unit is an external module, see dimensions on page 101. Application Machines with high inertia.
Characteristics Type of braking unit Ambient air temperature around the device
V
VW3 A7 101 - 10…+ 50 - 25…+ 70 IP 20 2 according to standard EN 50178 Class 3K3 without condensation 2000 0.2 gn a 380 - 15%…480 + 10%
V V c 785 ± 1% 850 kW
420
750 5 % at 750 kW 15% at 550 kW 50 % at 440 kW
Cycle time s
5 % at 420 kW 15% at 320 kW 50 % at 250 kW ≤ 240
Maximum continuous power kW
200
400
Operation Storage Degree of protection of enclosure Degree of pollution Relative humidity Maximum operating altitude Vibration resistance Nominal voltage of line supply and drive supply (rms value) Engage threshold Maximum DC bus voltage Maximum braking power on 400 V z supply Percentage of conduction time at constant power at 785 V c
785 V c (1)
°C °C m
Thermal protection
VW3 A7 102
Integrated, via thermal probe m3/h
Forced ventilation Installation
100
600
Vertical
Minimum resistor value to be associated with the braking unit
Ω
1.05
0.7
(1) Braking unit engage threshold
References: page 55
Selection: pages 58 to 61
Dimensions: pages 91 and 101
Schemes: page 118 and 123
54 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 57
References
0
Variable speed drives for asynchronous motors
0
Altivar 61 Option: resistance braking units
Braking units Supply voltage: 380…480 V 50/60 Hz For drives
Power
Loss
Continuous Max. kW ATV 61HC25N4, 200 ATV 61HC31N4 kW 420
ATV 61HC40N4, 400 ATV 61HC50N4, ATV 61HC63N4
750
Cable (drive-braking unit) Continuous CrossMax. power section length W mm2 m 550 – – Internal connections 750 2 x 150 1
Cable (braking unit-resistors) CrossMax. section length mm2 m 2 x 95 50
Reference
Weight
VW3 A7 101 kg 30.000
2 x 150
VW3 A7 102
80.000
50
Note: To increase the braking power, several resistors can be mounted in parallel on the same braking unit. In this case, do not forget to take the minimum resistance value on each unit into account, see Characteristics on page 54.
Presentation: page 54
Characteristics: page 54
Selection: pages 58 to 61
Dimensions: pages 91 and 101
Schemes: pages 118 and 123
55 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 58
Presentation, characteristics
0
Variable speed drives for asynchronous motors
0
Altivar 61 Option: braking resistors
Presentation The braking resistor enables the Altivar 61 drive to operate while braking to a standstill, by dissipating the braking energy. It enables maximum transient braking torque. The resistors are designed to be mounted on the outside of the enclosure, but should not inhibit natural cooling. Air inlets and outlets must not be obstructed, even partially. The air must be free of dust, corrosive gas and condensation. Application Inertia machines.
General characteristics Type of braking resistor Ambient air temperature around the device
Operation
°C
VW3 A7 701…709 0…+ 50
Storage
°C
- 25…+ 70
VW3 A7 710…718
Degree of protection of enclosure
IP 20
IP 23
Thermal protection
Via temperature controlled switch or via the drive 120 250 V a -1 A 24 V c -0.1 A 60
Via thermal overload relay
Temperature controlled switch (1)
Tripping temperature Max. voltage - max. current Min. voltage - min. current Maximum contact resistance
°C mΩ
Load factor for the dynamic brake transistors
– – – –
The internal circuits of Altivar 61 drives rated 220 kW or less have a built-in dynamic brake transistor. The dynamic brake transistor is designed so that it can tolerate 120% of the nominal motor power for 60 s.
ATV 61HpppM3, ATV 61HpppM3X, ATV 61H075N4…HD75N4, ATV 61W075N4…WD90N4, ATV 61W075N4C…WD90N4C ATV 61HD90N4…HC22N4
The dynamic brake transistor is designed so that it can tolerate 110 % of the nominal motor power for 60 s.
Connection characteristics Type of terminal Maximum wire size
VW3 A7 701…703
Drive connection 4 mm2 (AWG 28)
Temperature-controlled switch 1.5 mm2 (AWG 16)
VW3 A7 704…709
Bar connection, M6
2.5 mm2 (AWG 14)
VW3 A7 710…718
Bar connection, M10
–
Minimum ohmic value of the resistors to be associated with the Altivar 61 drive, at 20°C (2) Drive type
ATV 61H Ω
Minimum value Drive type
ATV 61H Ω
Minimum value Drive type
ATV 61H
Minimum value Drive type
Drive type Minimum value
U15M3
44 D90M3X 1.3 D75N4
U40M3
U55M3
U75M3
33
U22M3, U30M3 22
16
11
8
075N4… U22N4 56
U30N4, U40N4 34
U55N4
U75N4
D11N4
23
19
C13N4… C22N4 1.9
C25N4, C31N4 1.05
C40N4… C63N4 0.7
U75N4
D11N4
D15N4
23
19
12
U75N4C
D11N4C
D15N4C
23
19
12
Ω
3.3
D90N4, C11N4 2.5
Ω
075N4... U30N4 56
U40N4, U55N4 34
Ω
075N4C... U40N4C, U30N4C U55N4C 56 34
ATV 61W
Minimum value
075M3
ATV 61W
D11M3X, D15M3X 3
D18M3X
D22M3X, D30M3X 3.3
D37M3X… D75M3X 1.7
12
D15N4, D18N4 7
D22N4, D30N4 13.3
D37N4
D45N4, D55N4 5
D18N4, D22N4 7
D30N4, D37N4 13.3
D45N4
D55N4, D75N4 5
D90N4
D18N4C, D22N4C 7
D30N4C, D37N4C 13.3
D45N4C
D55N4C, D75N4C 5
D90N4C
4
6.7
6.7
6.7
3.3
3.3
(1) The contact should be connected in the sequence (use for signalling, or in the line contactor control). (2) The minimum ohmic value is determined at a temperature of 20°C. In an environment where the temperature is below 20°C, make sure that the minimum ohmic value recommended in the table is followed.
References: page 57
Selection: pages 58 to 61
Dimensions: pages 101 and 102
Schemes: pages 118 and 123
56 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 59
References
0
Variable speed drives for asynchronous motors
0
Altivar 61 Option: braking resistors
Braking resistors For drives
Ohmic value at 20 °C Ω
Average power available at 50 °C (1) kW
Reference
Weight
ATV 61H075M3
100
0.05
VW3 A7 701
1.900
ATV 61HU15M3, HU22M3
60
0.1
VW3 A7 702
2.400
ATV 61HU30M3, HU40M3
28
0.2
VW3 A7 703
3.500
ATV 61HU55M3, HU75M3
15
1
VW3 A7 704
11.000
ATV 61HD11M3X
10
1
VW3 A7 705
11.000
ATV 61HD15M3X
8
1
VW3 A7 706
11.000
ATV 61HD18M3X, HD22M3X
5
1
VW3 A7 707
11.000
ATV 61HD30M3X
4
1
VW3 A7 708
11.000
ATV 61HD37M3X, HD45M3X
2.5
1
VW3 A7 709
11.000
ATV 61HD55M3X, HD75M3X
1.8
15.3
VW3 A7 713
50.000
ATV 61HD90M3X
1.4
20.9
VW3 A7 714
63.000
100
0.05
VW3 A7 701
1.900
60
0.1
VW3 A7 702
2.400
28
0.2
VW3 A7 703
3.500
15
1
VW3 A7 704
11.000
10
1
VW3 A7 705
11.000 kg
Supply voltage: 200…240 V 50/60 Hz
Supply voltage: 380…480 V 50/60 Hz ATV 61H075N4…HU40N4 ATV 61W075N4…WU55N4 (2) ATV 61W075N4C…WU55N4C (2) ATV 61HU55N4, HU75N4 ATV 61WU75N4, WD11N4 (2) ATV 61WU75N4C, WD11N4C (2) ATV 61HD11N4, HD15N4 ATV 61WD15N4, WD18N4 (2) ATV 61WD15N4C, WD18N4C (2) ATV 61HD18N4…HD30N4 ATV 61WD22N4…WD37N4 (2) ATV 61WD22N4C…WD37N4C (2) ATV 61HD37N4 ATV 61WD45N4 (2) ATV 61WD45N4C (2) ATV 61WD55N4…WD90N4 (2) ATV 61WD55N4C…WD90N4C (2) ATV 61HD45N4…HD75N4
8
1
VW3 A7 706
11.000
5
1
VW3 A7 707
11.000
ATV 61HD90N4, HC11N4
2.75
25
VW3 A7 710
80.000
ATV 61HC13N4, HC16N4
2.1
37
VW3 A7 711
86.000
ATV 61HC22N4
2.1
44
VW3 A7 712
104.000
ATV 61HC25N4
1.05
56
VW3 A7 715
136.000
ATV 61HC31N4
1.05
75
VW3 A7 716
172.000
ATV 61HC40N4, HC50N4
0.7
112
VW3 A7 717
266.000
ATV 61HC63N4
0.7
150
VW3 A7 718
350.000
(1) Load factor for resistors: the value of the average power that can be dissipated at 50 °C from the resistor into the casing is determined for a load factor during braking that corresponds to the majority of normal applications. (2) The braking resistors’ degree of protection is IP 20 or IP 23.
Presentation: page 56
Characteristics: page 56
Selection: pages 58 to 61
Dimensions: pages 101 and 102
Schemes: pages 118 and 123
57 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com