Variable speed drives Altivar 61 Catalogue: Option: accessories, pages 34 to 43

Pages 34 to 43 of 211, from Variable speed drives Altivar 61 Catalogue

The original document is the PDF (4.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Telemecanique Altivar 61 ATV61, Schneider Altivar 61 ATV61 and Square D Altivar 61 ATV61

Page 34

Presentation, description

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: Multi-pump cards

Presentation Multi-pump cards are used to adapt the drive for pump applications. Various predefined configurable applications are sold by Schneider Electric and its partners. In order to protect our know-how, it is not possible to transfer the program from the card to the PC. A single multi-pump card can be fitted in the Altivar 61 drive. It can be combined with another option card (I/O extension or communication). Consult the tables summarizing the possible combinations: drives, options and accessories, see pages 84 to 89. Each multi-pump card consists of: b 10 logic inputs, 2 of which can be used for 2 counters b 2 analog inputs b 6 logic outputs b 2 analog outputs b A master port for the CANopen bus. If the power consumption table does not exceed 200 mA, this card can be powered by the ATV 61Hppppp drives. Otherwise, an external 24 V c power supply must be used. The ATV 61WpppN4A24 and ATV 61WpppN4C24 variable speed drives incorporate a 24 V c power supply and allow an additional consumption of 250 mA. Multi-pump cards can also use: b The drive I/O b The I/O extension card I/O b The drive parameters (speed, current, torque, etc.). The Altivar 61 drive: b Incorporates all the application functions for managing your pumps: sleep, wake-up, zero flow detection, fluid absence detection, underload detection, overload detection, PID regulator with preset PID references b Is used to adjust your pumps’ operating points: 2/5-point quadratic ratio, energy saving ratio b Protects your pumps: motor thermal protection, PTC management, low speed detection and time delay.

Description 4 532835

1 9-way male SUB-D connector for connection to the CANopen bus.

3

2 Connector with removable screw terminals, 6 contacts at intervals of 3.81 for the 24 V c power supply and 4 logic inputs. 3 3 connectors with removable screw terminals, 6 contacts at intervals of 3.81 for 6 logic inputs, 6 logic outputs, 2 analog inputs, 2 analog outputs and 2 commons. 4 5 LEDs, comprising: b 1 to indicate the presence of the 24 V c power supply b 1 to indicate a program execution fault b 2 to indicate the CANopen bus communication status b 1 controlled by the application program.

1

Operation: pages 33 and 34

2

Characteristics: page 35

References: page 35

Schemes: page 121

32 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 35

Operation

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: Multi-pump cards

Operation Multi-pump cards have the following basic operating modes: Single variable The same variable pump is always used. Fixed flow pumps are started in ascending order of the logic outputs. Fixed flow pumps are stopped in descending order of the logic outputs. Multiple variable All the pumps can be variable. The variable pump is chosen according to its operating time. The pump with the shortest operating time is selected. Fixed pumps are started and stopped in ascending and descending order of the logic outputs respectively. Switching the auxiliary pumps Single variable mode

You start by selecting the pump with the shortest operating time. You stop a pump by selecting the pump with the longest operating time. Limiting the operating time between pumps A relative operating time differential between each pump can be programmed to ensure better distribution of operating times, thereby limiting pump wear. If the total operating time differential between an operating auxiliary pump and one which is off exceeds the programmed differential, the first pump is stopped and replaced by the second one. Continuity of service for your installation If a pump is faulty (information on the Lix logic input) it is not taken into consideration and the start and stop conditions are determined by the other pumps. It is possible for each pump to: b Display the operating time b Reset the counter b Save the operating times.

Single variable mode with auxiliary pump

Presentation: page 32

Characteristics: page 35

References: page 35

Schemes: page 121

33 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 36

Operation (continued)

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: Multi-pump cards

VW3 A3 502 multi-pump card The VW3 A3 502 multi-pump card ensures the compatibility of pump applications developed for an Altivar 38 drive with an Altivar 61 drive. The card’s 9 operating modes are as follows: b OFF: no function is activated; this mode is used in particular during the installation’s maintenance b Single variable b Multiple variable b Single variable with changeover of auxiliary pumps b Multiple variable with changeover of auxiliary pumps b Single variable with limited operating time b Multiple variable with limited operating time b Single variable with changeover of auxiliary pumps and limited operating time b Multiple variable with changeover of auxiliary pumps and limited operating time.

VW3 A3 503 multi-pump card The VW3 A3 503 multi-pump card is used to support all multi-pump applications. In addition to the existing operating modes, it is possible to develop new applications: booster station, irrigation, etc.

Presentation: page 32

Characteristics: page 35

References: page 35

Schemes: page 121

34 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 37

Characteristics, references

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: Multi-pump cards

Electrical characteristics Power supply Power consumption Current Analog inputs

Voltage Maximum No-load Per logic output AI51, AI52

Analog outputs

AO51, AO52

Logic inputs

LI51…LI60

Logic outputs

LO51…LO56

Connection of I/O

Type of contact Maximum wire Tightening torque Life

Lithium battery

V A mA mA mm2 Nm

24 c (min. 19, max. 30) 2 80 200 maximum (1) 2 current analog inputs 0…20 mA, impedance 250 Ω Resolution: 10 bits Accuracy: ± 1% for a temperature variation of 60°C Linearity: ± 0.2% of the maximum value Common point for all the card I/O (2) 2 current analog outputs 0…20 mA, impedance 500 Ω Resolution: 10 bits Accuracy: ± 1% for a temperature variation of 60°C Linearity: ± 0.2% of the maximum value Common point for all the card I/O (2) Ten 24 V c logic inputs, compatible with leve1 1 PLC, IEC 65A-68 standard, 2 of which can be used for 2 counters or 4 of which can be used for 2 incremental encoders Impedance: 4.4 kΩ Maximum voltage: 30 V c Switching thresholds: State 0 if y 5 V or logic input not wired State 1 if u 11 V Common point for all the card I/O (2) Six 24 V c logic outputs, positive logic open collector type (source), compatible with level 1 PLC, standard IEC 65A-68 Maximum switching voltage: 30 V Maximum current: 200 mA Common point for all the card I/O (2) Screw, at intervals of 3.81 mm2 1.5 (AWG 16) 0.25 8 years approx.

References Description

Use

Reference

Weight kg 0.320

Multi-pump cards (3) This card ensures compatibility VW3 A3 502 equipped with one 9-way male with an ATV 61 drive of SUB-D connector applications developed for an ATV 38 drive This card can be used to VW3 A3 503 0.320 support all multi-pump applications (1) If the power consumption table does not exceed 200 mA, this card can be powered by the drive. Otherwise, an external 24 V c power supply must be used. (2) This common point is also the drive 0 V. (3) The Altivar 61 drive cannot support more than one multi-pump card. Consult the tables summarizing the possible combinations: drives, options and accessories, see pages 84 to 89.

Presentation: page 32

Operation: pages 33 and 34

Schemes: page 121

35 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 38

Presentation, description

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: “Controller Inside” programmable card

Presentation The “Controller Inside” programmable card is used to adapt the variable speed drive to specific applications by integrating control system functions. Various predefined configurable applications are sold by Schneider Electric and its partners. The PS 1131 software workshop for PC is used for programming and debugging new applications, quickly and in an open-ended manner (see page 39). It is not possible to transfer the program from the card to the PC, which enables us to protect our know-how. A single “Controller Inside” programmable card can be installed in the Altivar 61 drive. It can be combined with another option card (I/O extension or communication). Consult the tables summarizing the possible combinations: drives, options and accessories, see pages 84 to 89. The “Controller Inside” programmable card has: b 10 logic inputs, 2 of which can be used for 2 counters or 4 of which can be used for 2 incremental encoders b 2 analog inputs b 6 logic outputs b 2 analog outputs b A master port for the CANopen bus b A PC port for programming with the PS 1131 software workshop If the power consumption table does not exceed 200 mA, this card can be powered by the drive. Otherwise, an external 24 V c power supply must be used. The ATV 61WpppN4A24 and ATV 61WpppN4C24 variable speed drives incorporate a 24 V c power supply and allow an additional consumption of 250 mA. The “Controller Inside” programmable card can also use: b The drive I/O b The I/O extension card I/O b The encoder interface card points counter b The drive parameters (speed, current, torque, etc.).

Description

532835

5

4

1 RJ45 connector for connecting the PS 1131 software workshop via an RS 485 serial link. Connection to the PC is via a cable and an RS 232/RS 485 connector included in the VW3 A8 106 PowerSuite for PC connection kit. 2 9-way male SUB-D connector for connection to the CANopen bus. 3 Connector with removable screw terminals, 6 contacts at intervals of 3.81 for the 24 V c power supply and 4 logic inputs. 4 3 connectors with removable screw terminals, 6 contacts at intervals of 3.81 for 6 logic inputs, 6 logic outputs, 2 analog inputs, 2 analog outputs and 2 commons.

1

2

Characteristics: page 38

5 5 LEDs, comprising: b 1 to indicate the presence of the 24 V c power supply b 1 to indicate a program execution fault b 2 to indicate the CANopen bus communication status b 1 controlled by the application program

3

Functions: pages 39 to 42

Schemes: page 121

References: page 43

36 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 39

Description (continued)

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: “Controller Inside” programmable card

ATV 61

Dialogue

Magelis XBT

Human-machine dialogue with the application programmed in the “Controller Inside” programmable card is possible using: b The Altivar 61 graphic display terminal b A Magelis industrial HMI terminal connected to the drive Modbus port b A Magelis industrial HMI terminal connected to the Ethernet TCP/IP network (if the drive is equipped with an Ethernet TCP/IP communication card)

Modbus bus

A graphic terminal menu is dedicated to the “Controller Inside” programmable card. This menu can be customized by the card program according to the application. Sensors

Any industrial HMI terminal which supports the Modbus protocol can be used to display and modify the “Controller Inside” programmable card parameters. The Modbus server provides access to 2 Kwords (% MW, etc) in the card.

Independent machine with multiwire system

Magelis XBT

ATV 61

Modbus bus CANopen bus

Master CANopen communication The master CANopen port on the “Controller Inside” programmable card can be used to extend the I/O capacity and to control other CANopen slave devices.

ATV 31

ATV 31

Advantys STB distributed I/O

FTB 1CN

Independent machine with CANopen bus

Magelis XBT

Premium

Ethernet TCP/IP network ATV 61

ATV 61

Communication with a PLC The Altivar 61 drive equipped with a “Controller Inside” programmable card fits easily into complex architectures. Regardless of which bus or network is being used (Ethernet TCP/IP, Modbus/UniTelway, FIPIO, Modbus Plus, Profibus DP, INTERBUS, etc.), the PLC can communicate with the “Controller Inside” programmable card and the drive. The periodic variables can still be configured as required.

CANopen bus

Clock

Modular machine with Ethernet TCP/IP network

A clock backed up by a lithium battery makes it possible to have a log of events that have occurred. When the “Controller Inside” programmable card is installed in the drive, the drive faults are automatically time and date-stamped without special programming.

Characteristics: page 38

Schemes: page 121

Sensors

ATV 31

FTB 1CN

Functions: pages 39 to 42

References: page 43

37 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 40

Characteristics

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: “Controller Inside” programmable card

Electrical characteristics Power supply Power consumption Current Analog inputs

Voltage Maximum No-load Per logic output AI51, AI52

Analog outputs

AO51, AO52

Logic inputs

LI51…LI60

Logic outputs

LO51…LO56

Connection of I/O

Type of contact Maximum wire Tightening torque Life

Lithium battery

V A mA mA mm2 Nm

24 c (min. 19, max. 30) 2 80 200 maximum (1) 2 current analog inputs 0…20 mA, impedance 250 Ω Resolution: 10 bits Accuracy: ± 1% for a temperature variation of 60°C Linearity: ± 0.2% of the maximum value Common point for all the card I/O (2) 2 current analog outputs 0…20 mA, impedance 500 Ω Resolution: 10 bits Accuracy: ± 1% for a temperature variation of 60°C Linearity: ± 0.2% of the maximum value Common point for all the card I/O (2) Ten 24 V c logic inputs, compatible with level 1 PLC, IEC 65A-68 standard, 2 of which can be used for 2 counters or 4 of which can be used for 2 incremental encoders Impedance: 4.4 kΩ Maximum voltage: 30 V c Switching thresholds: State 0 if y 5 V or logic input not wired State 1 if u 11 V Common point for all the card I/O (2) Six 24 V c logic outputs, positive logic open collector type (source), compatible with level 1 PLC, standard IEC 65A-68 Maximum switching voltage: 30 V Maximum current: 200 mA Common point for all the card I/O (2) Screw, at intervals of 3.81 mm2 1.5 (AWG 16) 0.25 8 years approx.

Characteristics of the application program Compiled program (saved in “flash” memory) Data

Maximum size

Kb

320

Maximum size Saved size (NVRAM) Size accessible by Modbus

Kwords 64 Kwords 4 Kwords 2

Characteristics of the CANopen communication port Structure

Services

Diagnostics

Connector Network management Transmission speed Address (Node ID) CANopen application layer Functional profile PDO SDO Error check Other services Using LEDs

One 9-way male SUB-D connector Master Configurable via the program: 50 Kbps, 125 Kbps, 250 Kbps, 500 Kbps or 1 Mbps 32 slaves maximum DS 301 V4.02 DSP 405 10 receive and transmit PDOs in total for each slave 2 client SDOs per slave (1 read and 1 write). Block transfer Node Guarding, producer and consumer Heartbeat Emergency, Boot-up, Sync 2 LEDs: “RUN” and “ ERROR”, conforming to CIA DR303 version 1.0 (1) If the power consumption table does not exceed 200 mA, this card can be powered by the drive. Otherwise, an external 24 V c power supply must be used. (2) This common point is also the drive 0 V.

Presentation: page 36

Functions: pages 39 to 42

Schemes: page 121

References: page 43

38 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 41

Functions

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: “Controller Inside” programmable card

PS 1131 software workshop The PS 1131 software workshop conforms to international standard IEC 61131-3, and includes all the functions for programming and setting up the “Controller Inside” programmable card. It includes the configurator for CANopen. It is designed for Microsoft Windows® 98, Microsoft Windows® NT 4.0, Microsoft Windows® Millennium, Microsoft Windows® 2000 Professional and Microsoft Windows® XP operating systems. It benefits from the user-friendly interface associated with these operating systems: b Pop-up menus b Function blocks b Online help. The PS 1131 software workshop is available in both English and German. The programming and debugging tools are accessible via the application browser. This provides the user with an overview of the program and rapid access to all the application components: b Program editor b Function block editor b Variables editor b Animation tables editor b Runtime screens editor.

Modular structured programming The PS 1131 software workshop is used to structure an application into function modules consisting of sections (program code), animation tables and runtime screens. Each program section has a name and is programmed in one of the six available languages. To protect know-how or prevent any accidental modification, each section can be write-protected or read/write-protected. Exporting/importing function modules It is possible to export all or part of the tree structure in function modules.

Cyclic task or start of period

Acquisition of “Controller Inside” programmable card inputs and CANopen PDOs Exchange of periodic data with the drive

Program processing

Updating of “Controller Inside” programmable card outputs and CANopen PDOs End of task

Program structure and execution of an application The program structure is single-task. It consists of several subroutines. Exchanges with the drive are performed by a function block available in the standard library. Cycle execution can be either cyclic or periodic. A software watchdog, which can be configured between 100 and 800 ms by the user, monitors the cycle time. A task can be synchronized with the drive’s main task to improve repeat accuracy in motion control applications. Cyclic execution Once each cycle ends, execution of a new cycle begins. The cycle execution must last for at least 5 ms. Periodic execution The program is executed periodically, and the period can be set by the user between 5 and 100 ms. Cycle execution must last for less than the defined period. Drive response in the event of the cycle time being exceeded can be managed by the program.

Example of cycle execution for the “Controller Inside” programmable card connected on a CANopen bus

Presentation: page 36

Characteristics: page 38

Schemes: page 121

References: page 43

39 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 42

Functions (continued)

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: “Controller Inside” programmable card

Programming languages 6 programming languages are available: b Ladder language (LD) b Structured Text language (ST) b Grafcet language (SFC) b Instruction List language (IL) b Function block diagram (FBD) b Continuous Flow Chart (CFC)

Example of Ladder language programming

Example of Structured Text language programming

Ladder Diagram (LD) A Ladder language program consists of a set of rungs executed sequentially. A rung consists of several lines. A line consists of several contacts and a coil. The language objects can be entered and displayed as symbols or tags as required. The Ladder language editor enables the immediate call of entry help functions such as access to function libraries and access to the variables editor.

Structured Text (ST) Structured Text language is a sophisticated algorithmic type language which is particularly well-suited to programming complex arithmetical functions, manipulating tables, message handling, etc. Structured Text language enables direct transcription of an analysis based on a flow chart, and is organized in statements.

Grafcet language (SFC) Grafcet language is used to describe the sequential part of the control system in a simple, graphic way. It corresponds to the “Sequential Function Chart” (SFC) language described in standard IEC 61131-3. Programs written in Grafcet (SFC) language consist of: b Macro-steps which are the grouping of a set of steps and transitions b Steps with which the actions to be performed can be associated b Transitions with which the conditions are associated (transition conditions) b Directed links connecting the steps and transitions Example of Grafcet language programming

Presentation: page 36

Characteristics: page 38

Schemes: page 121

References: page 43

40 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 43

Functions (continued)

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: “Controller Inside” programmable card

Programming languages (continued) Instruction List language (IL) Instruction List language can be used to write Boolean equations and use all the functions available in the language. It can be used to represent the equivalent of a ladder diagram in text form. Each instruction consists of an instruction code and a bit or word type operand. As in Ladder language, instructions are organized in sequences of instructions called statements (equivalent to a rung). Function block diagram (FBD) FBD is a graphic language. It consists of function blocks connected by a rung. The program is executed sequentially. Each block can be a logical or arithmetical expression, a call to another function block, a jump or a return instruction. Example of Instruction List language programming

SETDRIVE_VEL_LFR iConsigne

SetDrive_Vel_LFR

Example of a function block: sending the speed reference to the drive

Continuous Flow Chart (CFC) Continuous Flow Chart programming is a graphic language. The rung connecting the various function blocks on the page is not necessarily sequential. The output of a function block may be looped back on its input or on the input of a block already inserted in the rung.

Function blocks The PS 1131 software workshop has pre-programmed function blocks (standard library) and offers users the option of creating their own function blocks (user library). Standard library The standard library contains: b Logic functions (AND, OR, etc.) b Mathematical functions (Cos, Sin, Exp, etc.) b Function blocks dedicated to drives which simplify data exchanges between the drive and the “Controller Inside” programmable card (e.g. sending the speed reference) b Function blocks for managing the CANopen bus b Graphic terminal display function blocks. User library Users have the option of creating their own function blocks in order to structure their applications. This is also a means of protecting the know-how contained in the algorithms, as it is possible to lock access to the user function blocks program.

Presentation: page 36

Characteristics: page 38

Schemes: page 121

References: page 43