Variable speed drives Altivar 61 Catalogue: additional EMC input filters

Pages 76 to 79 of 211, from Variable speed drives Altivar 61 Catalogue

The original document is the PDF (4.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Telemecanique Altivar 61 ATV61, Schneider Altivar 61 ATV61 and Square D Altivar 61 ATV61

Page 76

Presentation

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: additional EMC input filters

Integrated filters

L1 M1 3

L2

The Altivar 61 drive, except for the ATV 61HpppM3X, has built-in radio interference input filters to meet the EMC standard for variable speed electrical power drive “products” IEC/EN 61800-3, edition 2, category C2 or C3 in environment 1 or 2 and to comply with the European directive on EMC (electromagnetic compatibility).

L3

ATV 61HpppM3 ATV 61ppppN4 ATV 61WpppN4C with integrated filter

Drives

ATV 61H075M3…HU22M3 ATV 61HU30M3…HU75M3 ATV 61H075N4…HU40N4 ATV 61HU55N4…HD15N4 ATV 61HD18N4…HC63N4 ATV 61WpppN4 ATV 61WpppN4C

Maximum length of shielded cable according to EN 55011, class A (1) Group 1 (2) Group 2 (2) LF (3) HF (3) LF (3) HF (3) m m m m 10 5 – – – – 10 5 10 5 – – – – 10 5 – – 50 25 80 50 – – 80 50 20 5

Additional EMC input filters L1 L2

Additional EMC filter

L3

Altivar 61

M1 3

Applications Additional EMC input filters can be used to meet more stringent requirements and are designed to cut down conducted emissions on the line supply below the limits of standard EN 55011 group 1, class A or B (2). For the ATV 61HpppM3, ATV 61HD11M3X…HD45M3X and ATV 61H075N4…HD75N4 drives, the additional EMC filters can be mounted next to or under the device. They act as a support for the drives and are attached to them via tapped holes. For the ATV61HD90N4…HC63N4 drives, the additional EMC filters are only mounted at the side of the drives. Use according to the type of network Use of these additional filters is only possible on TN (neutral connection) and TT (neutral to earth) type networks. Standard IEC/EN 61800-3, appendix D2.1, states that on IT networks (impedance or isolated neutral), filters can cause permanent insulation monitors to operate in a random manner. In addition, the effectiveness of additional filters on this type of network depends on the type of impedance between neutral and earth, and therefore cannot be predicted. In the case of a machine which needs to be installed on an IT network, one solution consists of inserting an isolation transformer and placing the machine locally on a TN or TT network. (1) Maximum lengths for shielded cables connecting motors to drives, for a factory-set switching frequency of 2.5 or 4 kHz, depending on the rating (see page 10). If motors are connected in parallel, it is the total length that should be taken into account. (2) See page 8. (3) LF: low switching frequency. HF: high switching frequency. These frequencies depend on the drive rating. Drives Switching frequency LF HF kHz kHz ATV 61HpppM3 4 4.1…16 ATV 61H075N4…HD30N4 ATV 61HD37N4…HD75N4 2…2.5 2.6…12 ATV 61HD90N4…HC63N4 2…4 4.1…8 ATV 61W075N4…WD45N4 8 8.1…16 ATV 61W075N4C…WD45N4C 8 8.1…16 ATV 61WD55N4…WD90N4 4 4.1…16 ATV 61WD55N4C…WD90N4C 4 4.1…16

Characteristics: Page 75

References: Pages 76 and 77

Dimensions: Pages 106 and 107

Schemes: Page 122

74 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 77

Characteristics

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: additional EMC input filters

General characteristics Type of EMC filter Conformity to standards

VW3 A4 401…409 EN 133200

Degree of protection

IP 20 and IP 41 on upper part

IP 00 IP 30 with VW3 A9 601, 602 kits 93% without condensation or dripping water conforming to IEC 68-2-3

Maximum relative humidity Ambient temperature around the unit

Operation Storage

°C °C m

50/60 Hz three phase

V

Maximum operating altitude

Vibration resistance Shock resistance Maximum nominal voltage

VW3 A4 410…413

- 10…+ 50 - 25…+ 45 - 40…+ 65 - 25…+ 85 1000 without derating 1000…3000 derating the current by 1% per additional 100 m. Limited to 2000 m for the “Corner Grounded” distribution network 1.5 mm peak to peak from 3…13 Hz, 1 gn peak from 13…150 Hz, in accordance with IEC 60068-2-6 15 gn for 11 ms in accordance with IEC/EN 60068-2-27 240 + 10 % 480 + 10 %

Connection characteristics Maximum connection capacity VW3 A4 401 and tightening torque VW3 A4 402 VW3 A4 403 VW3 A4 404 VW3 A4 405…407 VW3 A4 408 VW3 A4 409 VW3 A4 410…412 VW3 A4 413

Presentation: Page 74

References: Pages 76 and 77

4 mm2 (AWG 10). 0.6 Nm 6 mm2 (AWG 8). 1.5 Nm 10 mm2 (AWG 6). 1.5 Nm 16 mm2 (AWG 4). 2 Nm 50 mm2 (AWG 0). 6 Nm 150 mm2 (300 kcmil). 25 Nm 25 mm2 (AWG 2). 4 Nm Bar connection, M10 – Bar connection, 2 x M12 –

Dimensions: Pages 106 and 107

Schemes: Page 122

75 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 78

References

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: additional EMC input filters

Additional EMC input filters Drives

Maximum length of shielded cable (1) EN 55011 (5) EN 55011 (5) class A Gr1 class B Gr1 LF (6) HF (6) LF (6) HF (6) m m m m

In (2)

Il (3)

Loss (4)

A mA

W

Reference

Weight kg

Three phase supply voltage: 200…240 V 50/60 Hz ATV 61H075M3, HU15M3

100

50

50

20

12

4

10

VW3 A4 401

2.200

ATV 61HU22M3…HU40M3

100

50

50

20

26

4.4

18

VW3 A4 402

4.000

ATV 61HU55M3

100

50

50

20

35

3

24

VW3 A4 403

5.800

ATV 61HU75M3

100

50

50

20

46

10

19

VW3 A4 404

7.000

ATV 61HD11M3X, HD15M3X

200

100

50

25

72

33

34

VW3 A4 405

12.000

ATV 61HD18M3X, HD22M3X

200

100

50

25

90

33

34

VW3 A4 406

15.000

ATV 61HD30M3X...HD45M3X

200

100

50

25

180

80

58

VW3 A4 408

40.000

ATV 61HD55M3X, HD75M3X

100

50

50

25

273

285

60

VW3 A4 410

22.000

ATV 61HD90M3X

100

50

50

25

336

500

125

VW3 A4 411

22.000

Three phase supply voltage: 380…480 V 50/60 Hz ATV 61H075N4…HU22N4

100

50

50

20

12

7

5

VW3 A4 401

2.200

ATV 61HU30N4, HU40N4

100

50

50

20

26

8

6

VW3 A4 402

4.000

ATV 61HU55N4, HU75N4

100

50

50

20

35

7

14

VW3 A4 403

5.800

ATV 61HD11N4

100

50

50

20

46

14

13

VW3 A4 404

7.000

ATV 61HD15N4 (7), HD18N4

300

200

100

100

72

60

14

VW3 A4 405

12.000

ATV 61HD22N4

300

200

100

100

90

60

11

VW3 A4 406

15.000

ATV 61HD30N4, HD37N4

300

200

100

100

92

60

30

VW3 A4 407

17.000

ATV 61HD45N4…HD75N4

300

200

100

100

180

140

58

VW3 A4 408

40.000

ATV 61HD90N4…HC16N4

300

150

50

25

273

500

60

VW3 A4 410

22.000

ATV 61HC22N4…HC31N4

300

150

50

25

546

500

125

VW3 A4 411

25.000

ATV 61HC40N4, HC50N4

300

150

50

25

728

500

210

VW3 A4 412

25.000

ATV 61HC63N4

300

150

50

25

1456

200

380

VW3 A4 413

34.000

(1) The filter selection tables give the maximum lengths for shielded cables connecting motors to drives for a switching frequency of 1 to 16 kHz (see page 10). These limits are given as examples only as they vary depending on the stray capacitance of the motors and the cables used. If motors are connected in parallel, it is the total length that should be taken into account. (2) Filter nominal current. (3) Maximum earth leakage current at 230 V and at 400 V 50 Hz on a TT network. (4) Via thermal dissipation. (5) See page 8. (6) LF: low switching frequency. HF: high switching frequency. These frequencies depend on the drive rating: For drives Switching frequency LF HF kHz kHz ATV 61HpppM3 4 4.1…16 ATV 61H075N4…HD11N4 ATV 61HD11M3X, HD15M3X 3.5...4 4.1…12 ATV 61HD15N4…HD30N4 ATV 61HD18M3X...HD45M3X 2…2.5 2.6…12 ATV 61HD37N4...HD75N4 ATV 61HD55M3X...HD90M3X 2.5…4 4.1…8 ATV 61HD90N4...HC63N4 2…4 4.1…8 (7) It is possible to use a special filter VW3 A4 409 with a leakage current Il (3) of 14 mA, which enables a maximum motor cable length of 100 m.

Presentation: Page 74

Characteristics: Page 75

Dimensions: Pages 106 and 107

Schemes: Page 122

76 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 79

References (continued)

0

Variable speed drives for asynchronous motors

0

Altivar 61 Option: additional EMC input filters

IP 30 protection kits Description

Presentation: Page 74

Mechanical device consisting VW3 A4 410, 411 of an IP 30 cover and cable clips

VW3 A9 601

Weight kg –

VW3 A4 412, 413

VW3 A9 602

–

Characteristics: Page 75

For filters

Dimensions: Page 107

Reference

Schemes: Page 122

77 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com