Page 1 of Andover Continuum Infinet II i2850 Series Terminal Controllers

Spec sheet · Schneider

Andover Continuum Infinet II i2850 Series Terminal Controllers

Spec sheet6 pagesPDF 563 KB

Specification sheet for the Andover Continuum Infinet II i2850, i2851 and i2853 terminal controllers for VAV and other terminal units.

Download the PDF563 KB

Covers · 2 models

The models it covers

Summary

What is in it

Schneider Electric's specification sheet for the Andover Continuum Infinet II i2850 Series terminal controllers (i2850, i2851 and i2853), DDC controllers for terminal units such as VAV boxes, unit ventilators and heat pumps. It describes features, inputs and outputs, flash memory, I/O expansion, Plain English programming, the Smart Sensor and local display, optional wireless Infinet, dimensional drawings and full electrical, communications, mechanical and model specifications.

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

This is the Schneider Electric specification sheet for the Andover Continuum Infinet II i2850 Series Terminal Controllers, covering the i2850, i2851 and i2853. It describes the inputs, outputs, communications, expansion and programming of these controllers for VAV boxes and other terminal units. It also lists their electrical and mechanical specifications and the model variants.

Device
Infinet II terminal controller for DDC control of terminal units such as VAV boxes, unit ventilators and heat pumps p. 1
Inputs
i2850: four full range universal inputs, one on-board airflow sensor and a room sensor input for the Smart Sensor or a standard room temperature sensor p. 2, 3
Outputs
Three Form A relays and one Form K Tri-state relay output, each rated 24 VAC/VDC, 3 amp p. 3
Power
24 VAC, +10% -15%, 50/60 Hz; 20 VA; fused with 2 amp fuse, MOV protected p. 5
Network
Andover Continuum Infinet RS-485 field bus to a network controller, 1200 to 19.2K baud; up to 254 Infinet devices per network controller p. 2, 5
Memory, processor
128K SRAM, 1MB FLASH; Motorola 32-bit Coldfire processor p. 6
Battery
Replaceable, non-rechargeable lithium battery; 5 years typical accumulated power failure backup of RAM p. 5
Size, weight
5.47 in H x 8.16 in W x 2.44 in D (139 x 207 x 62 mm); 1.08 lbs. (.50 kg); panel mount p. 5
Operating environment
32 to 120 °F (0 to 49 °C), 10 to 95% RH non-condensing p. 5
Input types
Voltage 0-5.115 VDC, temperature -30°F to 230°F, digital, counter up to 4Hz, supervised alarm; 0 - 20 mA with an external 250 ohm resistor p. 5
I/O expansion
Up to two xP modules on the bottom of the controller: xPDI8, xPUI4, xPDO2, xPDO4, xPAO2, xPAO4; the bus also supports the xP Display Module p. 3
Bus length
4,000 ft. (1,220m) standard; an i2 Infilink module extends it and is required after every group of 32 units p. 5
Model variants
i2850-S with Smoke-Control option; i2850-WL wireless; also i2851 and i2853 with -S and -WL versions p. 6
Programming
Plain English language, entered from CyberStation, Infinity SX 8000 Workstation or a local user terminal p. 4

What this sheet walks you through

  • Choosing between the i2850, i2851 and i2853 by inputs p. 2
  • Adding xP I/O expansion modules p. 3
  • Programming the controllers in Plain English p. 4
  • Connecting an Andover Continuum Smart Sensor p. 4
  • Mounting the xP-Display local display p. 4
  • Setting up wireless Infinet communication p. 4

Good to know

  • Wireless Infinet needs controllers with wireless compatible firmware. p. 4
  • The xP-Display must be mounted within 10 feet (3 meters) of the controller. p. 4
  • Any two consecutive Form A outputs can be set up as an additional Form K output. p. 3
  • The spec sheet states the enclosure type as UL Open class, IP 10. p. 5

Questions this sheet answers

What is the difference between the i2850, i2851 and i2853?

The i2850 has one on-board airflow sensor, the i2851 has none, and the i2853 has two for dual-duct VAV; all have four universal inputs. p. 2

What power does the i2850 need?

24 VAC, +10% -15%, 50/60 Hz, with a power consumption of 20 VA. p. 5

How many expansion modules can an i2850 take?

Up to two xP expansion modules, mounted on the bottom of the controller. p. 3

What are the i2850 relay output ratings?

Each relay is rated 24 VAC/VDC, 3 amp. p. 3

Does the i2850 keep its program after a power loss?

Yes: Flash memory stores the operating system and programs, and an on-board battery protects point and log data. p. 3

The whole text · 1 part

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6

The file

Revision and size

Part no.SDS-I2850-A4.BU.N.EN.11.2007.0.01.CC
RevisionNovember 2007
PublisherSchneider Electric
Pages6
PDF563 KB
TextText from the PDF itself.
SDS-I2850-A4.BU.N.EN.11.2007.0.01.CC

The first pages · 4 of 6

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 6
Page 2
Page 2of 6
Page 3
Page 3of 6
Page 4
Page 4of 6

More documents · 1

For the same models