Page 106

Convert 2 digits BCD to 8 bits in binary

F-03 →BIN

F-03 →BIN

Symbol

S

〔Example for use〕

D

Function

The contents of the register S (8 bits) are assumed as BCD code, converted into binary, then the result is stored in the register D.

Operation

S→D

Range of S

Range of D

Condition

04006

F-03 09300 09310 →BIN

09300 09310

When the input condition 04006 changes from OFF to ON, the contents of the register 09300 (8 bits) are assumed as BCD code, converted into binary, and its result is transferred to the register 09310. The contents of the register 09300 remain unchanged. If the contents of the register 09300 are not BCD code, the contents of the register 09310 are unchanged, and the error flag (07355) is set to "1". ・Transition of register contents and flags

コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777 コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777

09300 1 0 0 0 0 1 0 1

Rising edge of input signal (OFF to ON)

Contents of S

Instruction 04006

STR F-03

8

5

Zero 07357 0

Unchanged

0 1 0 1 0 1 0 1 09310

26 Carry 07356 0

4

+2 +22+20=64+16+4+1=85

Error 07355 0

Non-carry 07354 0

・Result After operation

Contents ・Unchanged when the contents of of D the register S are not BCD code.

Flag

Contents of register S

Zero 07357

Carry 07356

BCD code

0

0

Not BCD code

Error Non-carry 07354 07355

0 1

0

Similarity instructions: F-03w, F-53

9-31

09300 1 1 0 0 0 1 0 1

C (H) Zero 07357 0

5

09310

The contents of 09310 stay the same. Carry 07356 0

Error 07355 1

Non-carry 07354 0

9

Page 107

F-03w →BIN

Convert 4 digits BCD to 16 bits in binary F-03w →BIN

Symbol

S

〔Example for use〕

D

Function

The 2 bytes BCD contents (4 digits data) of the registers S, S+1 are converted into binary, and the result is stored in the 2 bytes area of the registers D, D+1

Operation

S1, S+1→D, D+1

Range of S

Range of D

Condition

Tens

Rising edge of input signal (OFF to ON)

9

6

4

Contents of registers S,S+1

Zero 07357

Carry 07356

BCD code Not BCD code

0

0

19000 0 0 0 0 0 0 0 0

27

20

Thousands Hundreds コ1001 0 1 0 0 0 0 0 0

Unchanged

After operation

Ones

コ1000 1 0 0 1 0 1 1 0

Unchanged when the Result (0 to 255) contents of the After registers S, S+1 Contents of operation Result (256 to 9999) are not BCD code. D+1

Flag

コ1000 19000

F-03w コ1000 19000 →BIN

Before operation

Contents of D

9

04001

When the input condition 04001 changes from OFF to ON, the contents of 4 digits BCD data in registers コ1000 and コ1001 are converted into binary, and its result is transferred and stored in 2 bytes area of registers 19000 and 19001.

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776 コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776

Contents of S,S+1

Instruction 04001

STR F-03w

0 BCD 4096

19001 0 0 0 1 0 0 0 0

215

28 BIN (Binary) 212=4096

Error Non-carry 07354 07355

0 1

0

Note 1: If the F-53 insutruction is used for programming, the F-03w instruction displays the program during monitoring. Similarity instructions: F-03, F-53

9-32

Page 108

F-04 →B C D Symbol

Convert 8 bits binary to 2 digits BCD F-04 →BCD

S

〔Example for use〕

D

Function

The contents of the register S (8 bits) are assumed as a binary code, converted into BCD code, then the result is stored in the register D.

Operation

S→D

Range of S

Range of D

コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777 コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777

04006

F-04 09320 →BCD

When the input condition 04006 changes from OFF to ON, the contents of the register 09320 (8 bits) are assumed as a binary code, converted into BCD code, and its result is transferred to the register 09330. The contents of the register 09320 remain unchanged. If the BCD number converted should exceed"100", the digit of hundreds will be disregarded.

5

3

2

2 +2 +2 +2 32 + 8 + 4 + 1

After operation

Contents Unchanged of S Contents Result of D

0 1 0 0 0 1 0 1 09330 0

4

5

=

Rising edge of input signal (OFF to ON)

09320 09330

09330

09320 0 0 1 0 1 1 0 1

Condition

Instruction 04006

STR F-04

45

09320 1 1 0 1 1 0 1 1 7+26+24+23+21+20

2

0 0 0 1 1 0 0 1 09330

1

9

=

Flag

Unchanged

219

9

Similarity instructions: F-04w, F-54

F-04w →BCD Symbol

Convert 16 bits binary to 6 digits BCD F-04w →BCD

S

〔Example for use〕

D

Function

The contents of 2 bytes binary in the registers S, S+1 converted into 6 digits BCD,and the result is stored in 3 bytes of the registers D, D+1, and D+2.

Operation

S, S+1→D, D+1, D+2

Range of S

Range of D

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776 コ0000 to コ1575 b0000 to b0775 09000 to 09775 19000 to 19775 29000 to 29775 39000 to 39775

04001

Instruction 04001

STR F-04w F-04w コ1000 19000 →BCD

コ1000 19000

When the input condition 04001 changes from OFF to ON, the contents of 2 bytes binary in registers コ1000 and コ1001 are converted into 6 digits BCD and stored in 3 bytes area of registers that begin from 19000.

Tens コ1000 0 0 0 0 0 0 0 0

27

20

Ones

19000 0 1 1 0 1 0 0 0

6

8

Thousands Hundreds

Condition

After operation

Rising edge of input signal (OFF to ON)

コ1001 1 0 0 0 0 0 0 0

Contents Unchanged of S, S+1 Contents Result (ones and tens) of D Contents Result (hundreds and thousands) of D+1 Contents Result (ten thousands) of D+2

Flag

215

28 Binary

19001 0 0 1 0 0 1 1 1

2

7

Ten thousands 19002 0 0 0 0 0 0 1 1

0

3

6 digits BCD 032768

Unchanged

Note 1: If the F-54 instruction is used for programming, the F-04w instruction displays the program during monitoring. Similarity instructions: F-04, F-54

9-33

Page 109

F-07 DCML

Transfer decimal (1 byte) constant (DeCiMaL) F-07 DCML

Symbol n

D

Instruction 04004

STR F-07

Function

A decimal constant "n" is transferred to the register D.

Operation n

04004

F-07 DCML

015

015 09100

09100

When the input condition 04004 changes from OFF to ON, the decimal constant "15" is transferred to the register 09100. The register 09100 is in the following binary code representation.

D

Range of "n"

000 to 255

Range of D

コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777

Condition

Rising edge of input signal (OFF to ON)

After operation

〔Example for use〕

09100 0 0 0 0 1 1 1 1

23+22+21+20=15

Contents n (000 to 255) of D

Flag

Unchanged

Similarity instructions: F-07w

9

F-07w DCML Symbol

Transfer decimal (1 word) constant (DeCiMaL) F-07w DCML n

D

〔Example for use〕

Instruction 04001

STR F-07w 04001

Function

A decimal constant "n" is transferred to the registers D, D+1.

Operation n→D, D+1

Range of "n"

00000 to 65535

Range of D

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776

Condition

Rising edge of input signal (OFF to ON)

0 1 0 1 1 0 0 0 1 0 0 0 0 0 1 1

Contents n (0000 to 65535) of D,D+1

214+212+211+27+21+20=22659

After operation

Flag

F-07w 22659 19100 DCML

22659 19100

When the input condition 04001 changes from OFF to ON, the decimal constant 22659 is transferred to the registers 19100 and 19101. The following binary code is stored in the registers 19100 and 19101.

19101

Unchanged

Note 1: Be sure to use even addresses for register D. Similarity instructions: F-07w

9-34

19100

Page 110

F-08 OCT

Transfer octal (1 byte) constant (OCTal) F-08 OCT

Symbol n

〔Example for use〕

D

Function

An octal constant "n" is transferred to the register D.

Operation n

Range of "n"

000 to 377 (8)

04004

After operation

F-08 OCT

015

015 09100

09100

When the input condition 04004 changes from OFF to ON, the octal constant 015 is transferred to the register 09100. The register 09100 is in the following code representation.

D

コ0000 to コ1577 b0000 to b0777 to 09777 Range of D 09000 19000 to 19777 29000 to 29777 39000 to 39777

Condition

Instruction 04004

STR F-08

09100 0 0 0 0 1 1 0 1

Rising edge of input signal (OFF to ON)

1

0

5

Contents n (000 to 377) of D

Flag

Unchanged

Similarity instructions: F-08w, F-71, F-71w

F-07 DCML

Reference Though F-07 (transfer decimal constant) handles a decimal number and F-08 (transfer octal constant) an octal number, the contents of the register after the transfer are represented in the binary code for both instructions.

013

F-08 OCT

=

09100

Symbol

09100

In the decimal 0 0 0 0 1 1 0 1 013 notation 7 6 5 4 3 2 1 0 0 0 0 0 1 1 0 1

2 2 2 2 2 2 2 2 to transfer R

2 3+ 2 2+ 2 0= 8 + 4 + 1 = 1 3 In the octal notation

0 0 0 0 1 1 0 1 0

F-08w OCT

015

1

5

Transfer decimal (1 word) constant (OCTal) F-08w OCT n

〔Example for use〕

D

Instruction 04001 STR F-08w

Function

An octal constant "n" is transferred to the registers D, D+1.

Operation n→D, D+1

Range of "n"

000000 to 177777 (8)

Range of D

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776

Condition After operation

04001

123456 19100

When the input condition 04001 changes from OFF to ON, the decimal constant 123456 is transferred to the registers 19100 and 19101. The following code is stored in the registers 19100 and 19101.

19101

Rising edge of input signal (OFF to ON)

Unchanged

Note 1: Be sure to use even addresses for register D. Similarity instructions: F-08, F-71, F-71w

9-35

19100

1 0 1 0 0 1 1 1 0 0 1 0 1 1 1 0 1

Contents of D, D+1 n (000000 to 177777)

Flag

F-08w 123456 19100 OCT

2

3

4

5

6

015

9

Page 111

F-09 INV

Complement 8 bits data (INVerter) F-09 INV

Symbol

S

〔Example for use〕

D

Function

The contents of the register S are complemented and stored in the register D.

Operation

S

Range of S

Range of D

コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777 コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777

After operation

Symbol

F-09w INV

S

S, S+1→D, D+1

After operation

〔Example for use〕

D

Operation

Condition

1 0 1 0 1 1 0 0 09003

Complement 16 bits data (INVerter)

The contents of the registers S, S+1 (16 bits) are complemented and stored in the registers D, D+1.

Range of D

09000 09003

09003

Unchanged

Function

Range of S

09000

09000 0 1 0 1 0 0 1 1

Rising edge of input signal (OFF to ON)

Flag

F-09 INV

When the input condition 04002 changes from OFF to ON, the 8 bits contents of the register 09000 are complemented and its result is stored in the register 09003. The contents of the register 09000 remain unchanged.

Contents Unchanged of S Contents Complement of register S contents of D

F-09w INV

04002

D

Condition

9

Instruction 04002

STR F-09

Instruction 04000

STR F-09w 04000

F-09w 09000 コ0040 INV

09000 コ0040

When the input condition 04000 changes from OFF to ON, the contents of the registers 09000 and 09001 (16 bits) are complemented and its result is stored in the registers コ0040 and コ0041. The contents of the registers 09000 and 09001 remain unchanged.

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776 コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776

09001

09000

0110101010101100

Rising edge of input signal (OFF to ON) Contents of S, S+1 Unchanged Contents Complement of register of D S contents Contents Complement of register S+1 of D+1

Flag

コ0041

コ0040

1001010101010011

Unchanged

Note 1: Be sure to use even addresses for registers S and D.

9-36

Page 112

Add register and register (BCD 2 digits) (ADD)

F-10 ADD

F-10 ADD

Symbol

S1

S2

〔Example for use〕

D

Function

The contents of the register S1 are added with the contents of the register S2 in BCD 2 digits and its result is stored in the register D.

Operation

S1+S2→D

Range of S1

Range of S2

Range of D

Condition

After operation

Unchanged

101 and above S1 and S2 are not BCD code.

Zero 07357

Carry 07356

23 23

23 23

23 23

23 23

5E 5E

(09010)

35 35

58 58

81 81

77 77

70 70

(09020)

17 58 (23+35)

58 81 (23+58)

81 04 (23+81)

04 00 (23+77)

Non-carry flag 07354 Error flag 07355 Carry flag 07356 Zero flag 07357

1 0 1 0 0

0 0 1 1 0

0 0 0 0 1

9

1 scan time, max.

Tens Ones

Tens Ones

09000 0 0 1 0 0 0 1 1

In case 3 BCD digits or more have to be added, the F-10 instruction must be provided successively. When the F-10 instruction is programmed repeatedly, the contents of the carry flag (07356) are also added after the second instruction. For the F-10 instruction that appears first in succession to the STR instruction, the contents of the carry flag (07356) are not added.

F-10 09001 09011 09021 ADD

Valid until a flag affecting instruction is met in the program.

1 1 0 0 0

Reference

F-10 09000 09010 09020 ADD

70 70 No addition (09000 not BCD).

Error Non-carry 07354 07355

Similarity instructions: F-10w, Fc10, Fc10w

04000 register (09000)

・Lower 2 digits of the result. ・Unchanged when the contents of registers S1 and S2 are not BCD code.

0 1 to 99 100

09000 09010 09020

Input (04000)

Unchanged

Result

Flag

F-10 09000 09010 09020 ADD

・Transition of result and flags

Rising edge of input signal (OFF to ON)

Contents of D

04000

When the input condition 04000 changes from OFF to ON, the contents of the register 09000 are added with the contents of the register 09010 and its result is stored in the register 09020. The contents of registers 09000 and 09010 remain unchanged.

コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777 コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777 コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777

Contents of S1 Contents of S2

Instruction 04000

STR F-10

Instruction STR 04000 F-10 09000 09010 09020 F-10 09001 09011 09021

9-37

2 3 Thousands Hundreds 09001 0 0 0 1 0 1 0 1 1

5

1 0 0 0 0 0 0 1 09010 +

8 1 Thousands Hundreds 0 1 1 0 0 1 1 1 09011 6 7 Tens Ones 0 0 0 0 0 1 0 0 09020 0 4 Thousands Hundreds 1 0 0 0 0 0 1 1 09021 8

3

・The above example shows the case of 1523+6781=8304. ・If programmed from lower digit, the carry information will be carried on to upper digit.

Page 113

Add register and register (BCD 4 digits) (ADD)

F-10w ADD

F-10w ADD

Symbol

S2

S1

〔Example for use〕

D

Function

The contents of the registers S1, S1+1 are added with the contents of the registers S2, S2+1 in BCD 4 digits and its result is stored in the registers D, D+1.

Operation

(S1, S1+1) + (S2, S2+1) →D, D+1

Range of S1

Range of S2

Range of D

Condition

9

04000

Instruction 04000

STR F-10w

19000 19002 19004

F-10w 19000 19002 19004 ADD

When the input condition 04000 changes from OFF to ON, the 4 digits BCD contents of the registers 19000 and 19001 are added with the contents of the registers 19002 and 19003 and its result is stored in the registers 19004 and 19005.

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776 コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776 コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776

19001

19000

0110011110001001

6

7

8

9

+ 19003

19002

0001001000110100

1

2

3

19005

Rising edge of input signal (OFF to ON)

4 19004

1000000000100011 Contents of S1,S1+1 Contents of S2,S1+2

Unchanged

Contents of D

Lower 2 digits of the result Upper 2 digits of the result

After Contents operation of D+1

8

0

2

3

Unchanged

Result

Unchanged when the contents of registers S1, S1+1, S2 and S2+1 are not BCD code.

Zero 07357

Carry 07356

Error Non-carry 07354 07355

1 0 0 1 0 0 0 1 1 1 0 0 10001 and above 0 1 0 0 Not BCD code 0 0 1 0 Note 1: Be sure to use even addresses for registers S and D. Similarity instructions: F-10, Fc10, Fc10w

Flag

0 1 to 9999 10000

Reference 19003

As double length operation is possible for the F-10w instruction, same as the F-10 instruction, write F-10w instruction in succession to add 5 digits or more BCD.

19002

19001

19000

10000111011001010100001100100001

8

7

6

5

4

3

2

1

+

00001

F-10w 19000 19004 19010 ADD

F-10w 19002 19006 19012 ADD

19007

Instruction STR 00001 F-10w 19000 19004 19010 F-10w 19002 19006 19012

19006

19005

19004

10011001100110011001100110011001

9

9

9

19013

9

9

19012

9

9

19011

9

19010

10000111011001010100001100100000

8

9-38

7

6

5

4

3

2

0

Page 114

Add register (BCD 2 digits) and constant (BCD 2 digits) (ADD)

Fc10 ADD

Fc10 ADD

Symbol

S1 n

Instruction 04001

〔Example for use〕

D

Function

The contents of the register S1 are added with the 2 digits BCD constant "n" and its result is stored in the register D.

Operation

S1+n→D

Range of S1

コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777

STR Fc10 04001

Fc10 09000 ADD

85

09000 85 09002

09002

When the input condition 04001 changes from OFF to ON, the contents of the register 09000 are added with the BCD constant 85 and its result is stored in the register 09002. It operates in the same timing as the F-10 instruction.

Range of "n" 00 to 99 コ0000 to コ1577 b0000 to b0777 09000 to 09777 Range of D 19000 to 19777 29000 to 29777 39000 to 39777

Condition

After operation

09000

00010011 1

3

+ BDC constant 85

9

10000101 8

Rising edge of input signal (OFF to ON)

10011000

Flag

0 1 to 99 100 101 and above S1 is not BCD code

Zero 07357

Carry 07356

1 0 1 0 0

0 0 1 1 0

9

Error Non-carry 07354 07355

0 0 0 0 1

1 1 0 0 0

Similarity instructions: F-10, F-10w, Fc10w Reference Similar to the F-10 instruction, it is possible to add 3 digits or more of BCD value.

00100

Fc10 09000 ADD

Fc10 09001 ADD

25

48

09020

09021

Instruction 00100 STR Fc10 09000 25 09020 Fc10 09001 48 09021

09001

09000

0010011101000110

2

7

4

6

+ 0100100000100101

4

8

2

09021

5 09020

0111010101110001

7

9-39

8

5

Contents Unchanged of S1 Contents ・Lower 2 digits of the result ・Unchanged when the contents of the of D register S1 are not BCD code. Result

09002

5

7

1

Page 115

Add register (BCD 4 digits) and constant (BCD 4 digits)

Fc10w ADD

Fc10w ADD

Symbol

S1 n

〔Example for use〕

D

Function

The BCD 4 digits contents of the registers S1, S1+1 are added with the 4 digits BCD constant "n" and its result is stored in the registers D, D+1.

Operation

(S1, S1+1) +n→D, D+1

Range of S1

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776

02001

Fc10w 19500 2345 ADD

Condition

9

19501

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776

Unchanged

Contents of D

Lower 2 digits of the result Upper 2 digits of the result

Flag

4

3

2

1

BDC constant 2345 0010001101000101

2

3

4

19601

Unchanged when the contents of registers S1 and S1+1 are not BCD code.

Zero 07357

Carry 07356

0 1 to 9999 10000

1 0 1 0 0

0 0 1 1 0

0 0 0 0 1

6

As double length operation is possible for the Fc10w instruction, same as the Fc10 instruction, write Fc10w instruction in succession to add 5 digits or more of BCD.

19010

6

6

Instruction STR 00001 Fc10w 19000 6789 19006 Fc10w 19002 2345 19010

19002

19001

19000

10000111011001010100001100100001

7

6

5

4

3

2

1

+ 00100011010001010110011110001001

2

Fc10w 19002 2345 ADD

6

19003

8

19006

19600

0110011001100110

1 1 0 0 0

Reference

Fc10w 19000 6789 ADD

5

Error Non-carry 07354 07355

Note 1: Be sure to use even addresses for registers S1 and D. Similarity instructions: F-10, F-10w, Fc10

00001

19500

+

Result

10000 and above Not BCD code

19500 2345 19600

0100001100100001

Rising edge of input signal (OFF to ON)

Contents of S1,S1+1

Contents of D+1 After operation

19600

When the input condition 02001 changes from OFF to ON, the 4 digits BCD contents of the registers 19500 and 19501 are added with the BCD constant 2345 and its result is stored in the registers 19600 and 19601.

Range of "n" 0000 to 9999

Range of D

Instruction 02001

STR Fc10w

3

4

19011

5

6

19010

7

8

19007

9

19006

00010001000100010001000100010000

1

9-40

1

1

1

1

1

1

0