Programmable controller New Satellite JW, JW50H/70H/100H User's Manual/Hardware version: Chapter8. Program transfer
Pages 182 to 184 of 254, from Programmable controller New Satellite JW, JW50H/70H/100H User's Manual/Hardware version
The original document is the PDF (8.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sharp ZW-16S2, Sharp ZW-32N2T and Sharp ZW-32S4T
Page 182
The JW-series programmable controllers have upward compatibility with the conventional W-series PCs(W10/ 16/51/100/70H/100H). A program written for a W-series PC and be transferred to the JW-series PC and executed on it. Some restrictions exist, however, due to the difference in the number of I/O points and the I/
O format:
wi 09 - Support too se ,| JwW50/70/100 ”| (See the following table - W100H 7 g JW50H/70H/100H (Direct transfer) W10 . Support tool ,| JW50/70/100 ae “| (See the following table) “| JW50H/70H/100H
(Transfer after program conversion)
[1] Usable support tool Any of the following support tools can be used for program transfer.
JW-50SP Ladder software JW-100SP
JW-30PG
JW-32PG Multipurpose programmer JW-40PG
Z-100LP2S Ladder processor Il
[2] Notes on program transfer Before transfering a program to the JW-series PC, check to make sure the following things. 1) Capacity mathcing The PC's program memory capacity and/or the number of 1/O points exceed those of the source
PC. JWS50 | ZW-1MA, JW-1MAH 7.5K words 16K bytes 512 points JWS50H ZW-1MA, JW-1MAH 7.5K words 16K words JW70 ZW-2MA, JW-2MAH 15.5K words 64K words 1024 point JW70H_ | ZW-3MA, JW-3MAH 31.5K words 128K words Ponts ZW-4MA, JW-4MAH 63K words 448K words ZW-1MA, JW-1MAH 7.5K words 16K words JW100 ZW-2MA, JW-2MAH 15.5K words 64K words 4096 point JW100H! ZW-3MA, JW-3MAH 31.5K words 128K words points ZW-4MA, JW-4MAH 63K words 448K words
Note : If the source (W series) PC's program memory capacity and/or the number of I/O points exceed those of the destination (JW-series) PC, transfer will not occur due to a "Memory capacity mismatch" error.
8-1
Page 183
2) Program transfer from JW-series PC to W-series PC The JW-series PCs feature system memory and some expansion application instructions which are not available on the W series PCs. A program containing application instructions which are not included in the W-series PC.
Only a program written using functions available on the destination PC can be transferred.
W100
JW50/70/100 W70H ‘ Support tool |< W100H JW50H/70H/100H
3) Transfer between JW50/70/100 and JW50H/70H/100H Compared to the JW50/70/100, the JW50H/70H/1 00H features additional functions, such as some of the application instructions. The transfer operation shown below is limited to programs which do not exceed the range of functions provided by the JW50/70/100.
Jws50/70/100 |---| Support tool_ }* - - - - - _ JWS50H/70H/100H
4) Differences between the JW-series PCs and the W100 The W100 has some differences from the JW-series PCs and its program requires the following modifications before this can be transferred to the JW-series PC: (1} If an unused I/O address area exists between the OUT1 and OUT2 areas used by the W100 PC program:
*When the JW-series PC is in the ZW-I/O mode (control module's DIP switch SW2-2 set to OFF), I/O relay addresses in OUT2 area require modifications.
_| W100's /O address allocation | Countermeasure |
Program using only OUT1 area
7 00000 Address OUTI Z Gym 04, area used! Not necessary for a 02000 countermeasure
Program using only OUT1 area
LE. 00000 OUT1 a) IA Not necessary for
PZZZZ| 02000 countermeasure oure{
Note 1: Using the l/O expansion module makes an area similar to OUT2 area available. See page 4-93, "I/O expansion module” of this manual.
Note 2: The JW50/70, JW50H/70H control modules do not allow this type of use, as they have max. 1024 I/O points.
8-2
Page 184
Relocate OUT2 area as shown:
00000
Unused I/O relay area exit between OUT1 and OUT2 area:
> 00000 77790000 p> OUT1 [ ij Nes ress oun LZ. LL area y 02000 02000 4 oure( (7 oure{
N
\
Note 2
Note 1: Use the ladder processor II to relocate the programmed I/O address space. Note 2: If the I/O expansion module is used in the ZW-I/O mode, relocation of the I/O address area is not necessay since a dummy area can be defined. For more details, see page 4-93. (2) Allowable voltage interruption time The JW-series PCs have a power lapse detection interval setting feature which must be set in system memory address #0246. Write 012,) for an interval of 10ms into address #0246.
System memory Setting value #0246 012¢8)
[3] Program transfer procedure (ZW to JW) It is not possible to directly transfer a program written for a W-series PC to the JW-series PC. First load the source system's program into a support tool, then trasnfer it to the destination PC.
Load the source program into the support tool. W series PC Support tool ' (W10/W16/W51 (The following diagram is Transfer the W100/W70H/W100H) the JW-50PG)
program to the destination PC.
Support tool JW50/70/100, JW50H/70H/100H (The following diagram is the JW-50PG)
For more details on program transfer procesures, refer to the instruction manual for each support tool.
8-3