Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Programmable controller New Satellite JW, JW50H/70H/100H User's Manual/Hardware version

Manual · Sharp

Programmable controller New Satellite JW, JW50H/70H/100H User's Manual/Hardware version

Manual254 pagesPDF 8.7 MB

Hardware user's manual for the Sharp New Satellite JW50H/70H/100H programmable controllers and their JW and ZW series I/O modules.

Download the PDF8.7 MB

Names · 3 models

The models it names

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

Hardware manual for the Sharp New Satellite JW50/70/100 and JW50H/70H/100H programmable controllers. It covers system design and general specifications, the control, memory, rack panel, I/O and power supply modules (including the ZW-8S2/16S2/16S4 wiring on the rack panel's 24 VDC terminal block), I/O bus expansion, the communication port, installation, wiring, ROM operation, program transfer, trial runs, the hand-held programmer, and maintenance and inspection.

Its parts

  1. Overview
  2. Safety precautions
  3. System design and general specifications
  4. Name and function of each part
  5. Installation
  6. Wiring
  7. ROM operation
  8. Program transfer
  9. Trial run
  10. Support tool operation
  11. Maintenance and inspection

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Hardware user's manual for the Sharp New Satellite JW50/70/100 and JW50H/70H/100H programmable controllers, covering their control, memory, rack, power supply and I/O modules, including ZW series I/O modules such as the ZW-16S2, ZW-32N2T and ZW-32S4T. It gives general specifications, module specifications, and error check flows for finding a faulty module. The pages are scanned and read by OCR.

Read for this summary: pages 10, 19, 25 to 28, 199 to 202, 232, 237 and 245 of 254.

System
Sharp New Satellite JW50/70/100 and JW50H/70H/100H programmable controllers p. 10
Ambient temperature
0 to 55 C p. 27
Ambient humidity
35 to 90% RH, non-condensing p. 27
Storage temperature
-20 to 70 C p. 27
AC power (JW-1PU)
100 to 120/200 to 240 VAC, 50/60 Hz p. 27
Module weight
ZW-32N2T approx. 600g; ZW-16S2 approx. 700g; ZW-32S4T approx. 800g p. 232, 237, 245
ZW-16S2 outputs
ZW-16S2: 16 DC outputs, 12/24 VDC rated (10 to 30 VDC range), 2A/point, 5A/common p. 237
ZW-16S2 fuse
ZW-16S2: one 5A miniature fuse per common, type FGMB-5A/125V (Fuji Tanshi) p. 237
ZW-16S2 wiring
ZW-16S2: 18 P detachable terminal block (M3.5X8 screws), 1 common line for 4 points p. 237
ZW-32N2T inputs
ZW-32N2T: 32 inputs, 12/24 VDC rated (11 to 26.4 VDC range), 1 common line for 32 points p. 232
ZW-32N2T response
ZW-32N2T: OFF to ON 15 ms or less, ON to OFF 20 ms or less p. 232
ZW-32S4T outputs
ZW-32S4T: 32 relay outputs, 240 VAC/30 VDC, 2A (resistance load), 1 common line for 8 points, no fuse p. 245
Fault indicators
RUN and FAULT LEDs on the power supply and control modules p. 199
Remote expansion
Expansion rack panel up to 50m from the PC rack panel via the I/O bus extension adapter p. 10

What this manual walks you through

  • Looking up modules in the module table p. 19, 25, 26
  • General specifications for AC and DC powered systems p. 27, 28
  • Preparing for troubleshooting with backups and spare modules p. 199
  • Choosing a check flow from the RUN and FAULT LED states p. 199
  • Clearing memory and ROM setting errors p. 200
  • Locating an I/O error by rack and slot p. 201
  • Replacing an I/O module with the power left on p. 202

Good to know

  • The troubleshooting flows exclude faults from initial setup, noise transients and the ladder program itself. p. 199
  • A faulty control module may not save program memory correctly, so the manual says to keep a current backup. p. 199
  • While live I/O installation/removal is set, the PC calculation is halted but the halt output stays on. p. 202
  • ZW-16S2: load voltage 10 to 30 VDC with peak voltage below 47V. p. 237

Questions this manual answers

What are the output ratings of the Sharp ZW-16S2?

The ZW-16S2 has 16 DC outputs rated 12/24 VDC, with a 10 to 30 VDC load range, 2A per point and 5A per common. p. 237

What fuse does the ZW-16S2 use?

One Class-B normal blow 5A miniature fuse per common, type FGMB-5A/125V (Fuji Tanshi). p. 237

What input voltage does the ZW-32N2T accept?

It is rated 12/24 VDC with an input voltage range of 11 to 26.4 VDC, on 32 points sharing one common. p. 232

How are the ZW-32S4T relay outputs grouped?

The 32 relay outputs are rated 240 VAC/30 VDC, 2A resistance load, with one common line for every 8 points. p. 245

What is the operating temperature of the JW series PC?

The general specifications give an ambient temperature of 0 to 55 C and storage from -20 to 70 C. p. 27

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Safety precautions3
  2. Chapter1. Overview10
  3. Chapter2. Safety precautions11
  4. Chapter3. System design and general specifications13
    1. 3-1 System design procedure13
    2. 3-2 Cautions on system design14
    3. 3-3 System configuration16
    4. 3-4 Table of module19
    5. 3-5 General specifications27
  5. Chapter4. Name and function of each part29
    1. 4-1 Combination of each module29
    2. 4-2 Control module36
    3. 4-3 Memory module48
    4. 4-4 Rack panel53
    5. 4-5 Input/output modules67
    6. 4-6 Power supply module (JW-1PU: Approved UL/CSA)98
    7. 4-7 JW-2PU power supply module104
    8. 4-8 ZW-100PU1/100PU2 expansion supply module108
    9. 4-9 JW-1EA/2EA I/O bus expansion adapter112
    10. 4-10 ZW-10EU I/O expansion module121
    11. 4-11 Communication port131
  6. Chapter5. Installation136
    1. 5-1 Precautions in installation136
    2. 5-2 Installation procedures137
    3. 5-3 Mounting rack panels inside a cabinet138
    4. 5-4 Installation of power supply module140
    5. 5-5 Installation of memory module141
    6. 5-6 Installing the control module146
    7. 5-7 Installation of I/O modules147
    8. 5-8 Installing the side panel on an I/O module149
    9. 5-9 Installing the expansion power supply module (for ZW-I/Os)150
  7. Chapter6. Wiring151
    1. 6-1 Precaution for wiring151
    2. 6-2 Wiring for JW-1PU power supply module159
    3. 6-3 Wiring for JW-2PU power supply module160
    4. 6-4 Wiring for ZW-100PU1/100PU2 expansion power supply module161
    5. 6-5 Wiring for expansion rack panel162
    6. 6-6 Wiring for input and output modules164
    7. 6-7 Wiring for 24 VDC terminal block on rack panel (for ZW-8S2/16S2/16S4)166
26 more lines, from page 168 on
  1. 6-8 Intercabinet cable routing examples168
  2. Chapter7. ROM operation171
    1. 7-1 What is ROM operation?171
    2. 7-2 Preparing for ROM operation172
    3. 7-3 Writing a program into ROM173
    4. 7-4 ROM operation method178
    5. 7-5 Battery-free operation180
  3. Chapter8. Program transfer182
    1. [1] Usable support tool182
    2. [2] Notes on program transfer182
    3. [3] Program transfer procedure (ZW to JW)184
  4. Chapter9. Trial run185
    1. 9-1 Periodical check185
    2. 9-2 Test run procedure186
    3. 9-3 Live I/O replacement187
  5. Chapter10. Support tool operation188
    1. 10-1 Hand-held programmer (JW-11PG/12PG/13PG/14PG)189
  6. Chapter11. Maintenance and inspection192
    1. 11-1 Periodic check192
    2. 11-2 Battery replacement195
    3. 11-3 Replacing a fuse196
    4. 11-4 Check a error199
  7. Chapter12. Appendix211
    1. 12-1 JW series I/O modules specifications211
    2. 12-2 ZW series I/O modules specifications227
    3. 12-3 Communication command list250

From the PDF’s own bookmarks.

The whole text · 30 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Safety precautions1-5
  2. Table of contents6-9
  3. Pages 10 to 1210-12
  4. Chapter3. System design and general specifications, pages 13 to 2013-20
  5. Chapter3. System design and general specifications, pages 21 to 2821-28
  6. Chapter4. Name and function of each part, pages 29 to 3829-38
  7. Chapter4. Name and function of each part, pages 39 to 4839-48
  8. Chapter4. Name and function of each part, pages 49 to 5849-58
  9. Chapter4. Name and function of each part, pages 59 to 6859-68
  10. Chapter4. Name and function of each part, pages 69 to 7869-78
  11. Chapter4. Name and function of each part, pages 79 to 8879-88
  12. Chapter4. Name and function of each part, pages 89 to 9889-98
  13. Chapter4. Name and function of each part, pages 99 to 10899-108
  14. Chapter4. Name and function of each part, pages 109 to 118109-118
  15. Chapter4. Name and function of each part, pages 119 to 128119-128
  16. Chapter4. Name and function of each part, pages 129 to 135129-135
  17. Chapter5. Installation136-150
  18. Chapter6. Wiring, pages 151 to 160151-160
  19. Chapter6. Wiring, pages 161 to 170161-170
  20. Chapter7. ROM operation171-181
  21. Chapter8. Program transfer182-184
  22. Chapter9. Trial run185-187
  23. Chapter10. Support tool operation188-191
  24. Chapter11. Maintenance and inspection, pages 192 to 201192-201
  25. Chapter11. Maintenance and inspection, pages 202 to 210202-210
  26. Chapter12. Appendix, pages 211 to 219211-219
  27. Chapter12. Appendix, pages 220 to 228220-228
  28. Chapter12. Appendix, pages 229 to 237229-237
  29. Chapter12. Appendix, pages 238 to 246238-246
  30. Chapter12. Appendix, pages 247 to 254247-254

The file

Revision and size

RevisionVersion 1.4, produced in Nov. 2000
PublisherSharp
Pages254
PDF8.7 MB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.

The first pages · 3 of 254

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 254
Page 2
Page 2of 254
Page 3
Page 3of 254