Page 188
The support tools are used to create, monitor or modify programs for the PC. The various tools which support the functions of the control modules are listed below.
urpose programmer
JW-50CU
JW-70CU A O O Oo O JW-100CU
JW-50CUH
JW-70CUH A O oO A O JW-100CUH der processor Il, ZAOOLP2S JW-50CU JW-70CU A O O 6 JW-100CU JW-50CUH JW-70CUH A A O 5 JW-100CUH
©: Can be used. 4\: Can be used within the functional range of the support tool.
(For example, if the JW-30PG/32PG is used for the JW-50CUH/70CUH/100CUH, the newly added instructions and functions on the JW50H/70H/100H will not be supported.)
Note 1: The circle only for the high-speed compatible version. The triangle for all other versions. (See the next page.) Note 2: Installation of the expansion module (Z-3LP2EM) to the Z-100LP2S is required. Note : Exercise care when displaying TMR/CNT 1000 to 1777 are shared with general-purpose relays 43000 to 14777.
Setting of system memory #0201 H-series compatible support tools Other support tool
512 timer and counter points Displays as 13000 to 14777. ; Incorrectly displayed.
1024 timer and counter points Correctly displayed
Note : When the system memory of the JW50H/70H/100H is cleared with a support tool (including those that are not H-series compatible), the program memory capacity is set to the maximum capacity of the installed memory module. (The capacity is set to 7.5K words on the JW50/70/ 100.)
See the instruction manual included with your support tool for details regarding the operation. "10-1 Hand-held programmer (JW-11PG/12PG/13PG/14PG)" is provided for reference.
10-1
Page 189
10-1 Hand-held programmer (JW-11PG/12PG/13PG/14PG)
[1] Connecting to the control module The hand-held programmer connects to the support tool port connector on the control module using the ZW-3KC cable (optional).
Connector for support tool
Hand-held programmer JW-11PG/12PG/13PG/14PG Le"
Control module
(JW-S0CU/70CU/1 00CU JW-50CUH/70CUH/1 00CUH)
Note 1: Refer to page 11-3, if it is impossible for support tools to operation "write". Note 2: Use the JW-11PG (compatible with high-speed model), JW-12PG/13PG/1 4PG for the JW- 50CUH/70CUH/1O0CUH.
10-2
Page 190
Otherwise the hand-held programmer can be directly mounted on the contro! module by using the mounting bracket supplied with the programmer.
[Installing mounting bracket on power supply module]
Remove the front cover from the power supply module and secure the mounting bracket to the power supply module with a screw as shown:
Power supply + module
Power supply module Power supply module Programmer mounting bracket
Power supply "==S module cover “~
“Tak Support tool | connector {
“1 ~ Communication port ca g aaa ee . Bracket retention screw amd
Control module
JW-50CU/70CU/100CU JW-50CUH/70CUH/1 00CUH
[Installing programmer] Plug the hand-held programmer's back connector plug into the support tool port connector on the | conirol module, then secure the programmer to the mounting bracket using two screws.
Note: Before mounting the programmer on the control module, remove the communication port connector cover from the control module. Keep the cover in a safe place.
[2] Table of function The hand-held programmer (JW-11PG/12PG/13PG/14PG) which has as following functions.
Function a Program | Monitor | Change | PC mode Stop
Memory clear (all memories: program, O data, file, and system memories)
System memory read System memory write
Instruction read
Write, insert, delete, batch write, batch insert, and batch delete instructions
Program copy (write, insert)
Read relay ON/OFF status Set/reset relays
Read timer, counter, and MD's current 5 values
O JO;OJO]O jOJO|O
Set/reset timers and counters O
10-3
Page 191
Read register and file register's current values (binary, octal, decimal, hex, and O O O ASCIl) 6 Write, insert, delete, batch write, batch delete, copy write, and copy insert O O cuurent values of registers and file registers All memory read O O O 7 All memory write O ; Instruction search O © O Data memory search O O O Change preset values of timers, O O counters, and MDs 9 Change constants for application instructions O O ‘Forced ON/OFF control over I/O relays O Break monitor O © 10 Step operation oO O N-scan operation O O 11) Device features (display output, key entry) Program check © te Parity check O 43 Cassette tape transfer (save, verify) O O O Cassete tape transfer (load) O 44| EEPROM write/read 6) /O module setup (I/O address and dummy areas) O 15] |/O information monitor (address, type, No. of points) O O O I/O module's lamp check @) O O Time setting O 16 Time monitor oO Oo O Remote parameter setting Oo 17 Set parameters for communication module O Remote programming O Remote monitoring O Key press tone ON/OFF control O O O O 18 | EL backlight ON/OFF control O O O © LCD contrast adjustment oO O O O [3] Handling
For handling of the hand-held programmer, see the instruction manual for the programmer.