Programmable controller New Satellite JW, Model name JW50H/70H/100H, User's Manual/Hardware version: Chapter4. Name and function of each part, pages 129 to 135

Pages 129 to 135 of 254, from Programmable controller New Satellite JW, Model name JW50H/70H/100H, User's Manual/Hardware version

The original document is the PDF (8.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sharp ZW-32IO2 and Sharp ZW-32S2T

Page 129 read from a scan by OCR; it may hold reading errors

(4) Self diagnosis The following lists the I/O module self diagnostic features available when the ZW-10EU 1/O expansion module is installed :

1/0 data bus

/O bus floating check Yes Yes (error code 44)

Input or output module discrimination signal's Yes Yes simultaneous ON check

VO signal

(error code 45) input or output module discrimination signal Yes Yes response check *Note 2 Output-data-bus check Yes No *Note 2

Note 71: The self diagnostic features above must be specified in system memory addresses #0250 and #0252. For more details, see the programming manual, section 2-4, system memory.

Note 2: The self diagnostic feature does not check the expansion pon's 1/O signal output onto the data bus.

Note 3: If an error is detected during the self diagnosis, error code 44 or 45 is written into system memory address #0160 and special relay 07373 is activated. For more details, see the programming manual, section 2-8, "Self-diagnosis".

4-101

Page 130 read from a scan by OCR; it may hold reading errors

[4] Outline dimension drawings

[zw-1oeu | ) I PULL 6 OS OUT Y 33.5 105 ly > 130 (include the rack panel) Laat _»

Specifications Ban ei

Expansion I/O modules supported | Max. 32 modules (64 modules in total)

Length of expansion signal cable Total 4m

Current drawn 70 mA Weight 0.3 kg Accessory Instruction manual

The general specifications for storage temperature, operating temperature, relative humidity, vibration, impact, and so forth are identical to those given in section 3-5 (page 3-15), "General Specifications’.

4-102

Page 131 read from a scan by OCR; it may hold reading errors

4-11 Communication port

[1] Outline The special communication port provided on the JW-70CU/ 100CU, JW-70CUH/100CUH control module allows the PC to communicate with a personal computer or any other host device with an internal RS-232C/422/485 serial port.

Communication port

[2] Usable commands The ZW-10CM, JW-10CM link module's computer link commands listed below are available for communication with a host device: C)

Hi Read/Write commands (Note 1)

Relay MRL SRR (Set/Reset) Timer/counter/MD MTC SRT (Set/Reset) Register MRG WRG FRG (Writ the same data) File register RFL WFL RFLF WELF (for files 1 to 7) System memory RSM WSM Program RPM WPM CTC (change setting value of timer/counter)

Mi Control commands

HLT Halt PC run

RUN Restart PC run MPC Monitor PC run

VLM Read memory capacity

SVL Set memory capacity

EWR Set write mode

SWE Read status in write mode

Note 1: When executing a write command to system or program memory, set the control module's memory protection switch to OFF(write enable). Write access to the file registers can be disabled by setting the contents of system memory address #0244.

Note 2: The global address feature (command to write station address 00 into all PCs) is not available.

Note 3: For the JW-70CUH/100CUH, the current vatue monitor command (MTC) for the timer and counter cannot read 777 or below and 1000 or above simultaneously. The responses of 1000 and above apply to the ZW mode (without additional information) and not to the JW mode (with additional information).

4-103

Page 132 read from a scan by OCR; it may hold reading errors

[3]

[4]

Setting the communication format Specify the communication format needed for communication with the host device in the PC's system memory.

#0236 Transmission rate, parity bit, stop bit length

#0237 Station No. (0018) to 037(2))

*Contents of system memory location #0236.

D7 D6 D5 D4 D3 De D1 DO . * For more details, refer to

0 0 programming manual.

--_--_ - __ - ‘Transmission rate (600 to 19200 bits/s)

Parity (none, odd, even)

Stop bit length (1 or 2 bits}

The communication port doesn't operation in the case of writing the other data in the system memory #0236 by WSM command.

Precautions for use of the communication port (1) The writing mode (modes 0,1, and 2} can be selected and the operation of the JW70/100 or

JW70H/100H PC can be restarted or stopped using external signals input thorough the communication port or through the support tool connector.

There is no priority for triggers whether they received through the communication port or through the support tool connector. However, the most recent trigger received will take priority over all precious triggers. Therefore, pay attention to the PC operation status (start/stop operation) when operating a support tool or sending a command, as shown in the example below.

Ex.: When you send a RUN command through the communication port after stopping the PC operation using the hand-held programmer, the PC will restart operation with this RUN command. In this case, even if the PC is running, the hand-held programmer can write a program into the PC and this will cause a malfunction.

(2) With the JW70/100, if you cannot write data through the communication port, the PC mode may have been changed (from the write mode to the RUN mode) through the support tool connector or the expansion module connector. If this is the case, reset the PC mode.

(3) Command resend wait time If you want to send another command immediately after receiving a response through the communication port, make sure to wait at least 30 ms. The communication port needs 30ms to change from its send operation to a receive operation.

| Send response

(4) We recommend that you reissue the command (retry) when any communication error occurs, including a | 30ms to change from receive to send simple failure to respond. This will not have a negative influence on the system.

4-104

Page 133 read from a scan by OCR; it may hold reading errors

[5] Wiring

{1) Port connector pin description RS-232C RS-422/485 f _ Protective ground 1 FG Protective ground 2 TXD Transmit data (PC to host) 10 TXD : -, Transmit data (PC to host} 3 RXD Receive data (host to PC} 11 TXD . 4 ATS Active whenever the PC power 12 RXD Receive data (host to PC) :, - eceive data (host to is turned ON. 13 RXD - ( Clear to send. Transmission is Termination { Only the termination station 5 CTS enabled when active ;disabies 6 resistance connects to 3 (RXD) when inactive. 7 SG. __j__ Signal ground Short these pins when the port 12,14 Shorting pins is to be used in RS-232C mode.

Note : Pin No. 6 (termination resistance) is available on the JW-70CUH/100CUH but not on the JW- 7OCU/100CU.

(2) In case that target station is RS-232C «When the total! cable length is less than 15m:

PC Host device FG, - ft rc 2 RX | >) RD D 3 i TD RTS | 4 > CS ors JY SG / 7 i * Y SG 12 |< Short for RS-232C mode 14 Recommended cable : ; 45 mor less | | Fujikura cable 7PX7/0.18 - i 57VV-SB vinyl-insulated, multicore cable

«When the total cable length exceeds 15m: Signal converter (Z-101HE)

PG poe Host device TXD Non 10 Sie ] \ >| RD(+) 3] RD > RD 11 >! RD(-) 2/ TD F TD _RXD A 12 - - _ TD(+) 4! RS kK aS zo | / \ 13 /* Y TD(-) 7) SG SG FG 7 1 SHIELD 1| FG FG Class-3 se ; grounding T ‘ < 1km or less | __15mor less RS-485 RS-232C

4-105

Page 134 read from a scan by OCR; it may hold reading errors

(3) in case that target station is RS-485

PC (Up to 31 sets) Host device PC TXD TXD 10 A 140, 7X {> ..Rxp 17 Ye 14 A + RXD 12 XO A 12 < BAP TXD RXD / \ RXD / \ XD | 13 ; Y 13 |< Y TXD ; FG 1 FG 7 EG < 1 km or less > RS-485

Recommended cable : Hitachi cable CO-SPEV-SB0.5

Note 1: The Z-101HE signal converts RS-232C/RS-422 compatible signals transferred from the host device into RS-485 compatible signals with high noise immunity.

Note 2: The RS-485 standard was set forth by EIA in Apri! 1983 as an enhancement of the RS-422 standard. The conventional computer link, data link, and remote I/O modules also conform to the RS-485 standard.

[6] Preparing the cable Before soldering the serial communication cable to the plug pins, prepare it as described below:

Sleeve

(10mn)

3 Fold back the shield conductor

Strip the outer sheath to about 30mm from the cable end.

Cut the braided outer shield conductor to about 10 mm length.

Pass a sleeve over the cable.

onto the sleeve.

4-106

Aiminium foil tape, = Wrap the folded shield conductor with aluminium fiol tape.

(12mm), Strip the core insulators to about 4mm from the wire ends.

Soldering

K. Soldering ir iron Solder - Wet core conductors with sotder.

~N Cable

Recommended cable: Fujikura Cable 7P x 7/0.18 57VV-SB vinyl-insulated, multicore cable

Page 135 read from a scan by OCR; it may hold reading errors

[7] 15-pin Dsub connector The serial communication port uses a 15-pin Dsub connector. The mating cable plug is supplied with the JW-70CU/100CU, JW-70CUH/100CUH control module.

tJ M3X12 screws

Shell

Connector Aluminium foil tape

Cable clamp J

TL “a

Shell D-sub connector (15P male)

Daiichi Electronics Industries

17JE-23150-02(D8A) M3 hex nuts

[8] Soldering and assembly

Phillips head machine screw

(M3 12)

i

Solider

Soldering iron

Shell

| Fitting screw | '

Heat shrink tube

Philips head machine screw

(M3 X 6) M3 hex nut oe x =] 12345676, - a O eoo0000000 O

Cable clamp

Connector pin number diagram (outer view)

4-107