Page 169
Chapter 10 Computer link 10-1 Description for computer link · You can transmit data between JW-20CM and host computer having a network module ZW-98CM/ZW20AX and the like. · Computer link function can not be used separate mode, but simultaneously with operation of data link function. · Both JW and ZW model PCs can be connected on the same cable.
JW-20CM
PC
ZW-20CM
PC
Network module
JW-22CM JW20 JW20H JW30H
(64 stations max., Total length: 1km max.)
· In order to use the computer link function, you must use application software which can send a command from the host computer and receive a response from the opposite station. See “Instruction manual of network module ZW-98CM/ZW-20AX etc.” and the like for operation method on host computer side.
10
10·1
Page 170
10-2 Communication method The host computer communicates with each station number one by one. ① The host computer instructs station number/communication contents/memory address/data etc. of the communicating station as a “command.” ② The “command” receiving station processes this data and returns the result as “response.” (System example) Master station 00(8)
Slave station 01(8)
Slave station 02(8)
Slave station 03(8)
Host computer
Command Response
On the computer link, the host computer can communicate with any required station regardless of whether it is the master or slave station.
10
10·2
Page 171
10-3 Switch setting Same as setting switch of data link. (See page 9·17 to 9·21) When you was already used for data link, setting switch is unnecessary.
Operation procedure
Start
Power “OFF” master/slave station
Remove the setting switch cover.
Set MODE (function) switch
Set STA. NO. (station number) switch
Set LT (termination resistance) switch
Set LG (shield ground) switch
Attach label
End
10·3
10
Page 172
10-4 Command For communication format etc., see network module ZW-98CM/ZW-20AX etc. instruction manual of host computer side. Read out relay (1 point unit) Function
Read out ON (01(H))/OFF (00(H)) status of specified relay.
Command code
00(H) (MRL)
Writing mode assignment
No
Operation condition of PC
Unrelated
Assignable address
00000 to 15777(8)
Letters in brackets are command name of BASIC mode.
Set/reset relay (1 point unit) Function
Set (01(H))/reset (00(H)) the specified relay.
Command code
10(H) (SRR)
Writing mode assignment
No
Operation condition of PC
Unrelated
Assignable address
00000 to 15777(8)
Letters in brackets are command name of BASIC mode.
10
· "Writing mode assignment" is used to show whether writing to the PC memory has been enabled or disabled. 0: Writing prohibited 1: Enable writing only to data memory 2: Enable writing all data. No setting: Enable writing in any mode
10·4
Page 173
Read out current value of register/file register (1024 bytes max./ one time) Function
Read out current value that specified register/file register
Command code
00(H) (MRG, RFLF)
Writing mode assignment
No
Operation condition of PC
Unrelated
Letters in brackets are command name of BASIC mode.
Assignable address
When PC is ZW model
※
When PC is JW model
コ0000 to コ1577 b0000 to b1777
コ0000 to コ1577 b0000 to b1777
09000 to 09777
19000 to 19777
09000 to 09777
19000 to 19777
29000 to 29777
39000 to 39777
49000 to 49777
59000 to 59777
69000 to 69777
79000 to 79777
89000 to 89777
99000 to 99777
E9000 to E9777
E1000 to E1777
File 1 to 7 : 000000 to 177777
※ Usable file number varies with memory module using for PC. (See page 13·21) ※
File 1 to 7 : 000000 to 177777
Write in register/file register (1024 bytes max./ one time) Function
Write in manual data that specified register/file register
Command code
13(H) (SRT)
Writing mode assignment
1 or 2
Operation condition of PC
Unrelated
Letters in brackets are command name of BASIC mode.
Assignable address When PC is ZW model
※
When PC is JW model
コ0000 to コ1577 b0000 to b1777
コ0000 to コ1577 b0000 to b1777
09000 to 09777
19000 to 19777
09000 to 09777
19000 to 19777
29000 to 29777
39000 to 39777
49000 to 49777
59000 to 59777
69000 to 69777
79000 to 79777
89000 to 89777
99000 to 99777
E9000 to E9777
E1000 to E1777
File 1 to 7 : 000000 to 177777
※ Usable file number varies with memory module using for PC. (See page 13·21) ※
File 1 to 7 : 000000 to 177777
· "Writing mode assignment" is used to show whether writing to the PC memory has been enabled or disabled. 0: Writing prohibited 1: Enable writing only to data memory 2: Enable writing all data. No setting: Enable writing in any mode
10·5
10
Page 174
Write in same data to register/file register Function
Write in same data that specified register/file register
Command code
12(H) (FRG)
Writing mode assignment
1 or 2
Operation condition of PC
Unrelated
Letters in brackets are command name of BASIC mode, but unavailable for writing in same data to file register.
Assignable address When PC is ZW model
※
When PC is JW model
コ0000 to コ1577 b0000 to b1777
コ0000 to コ1577 b0000 to b1777
09000 to 09777
19000 to 19777
09000 to 09777
19000 to 19777
29000 to 29777
39000 to 39777
49000 to 49777
59000 to 59777
69000 to 69777
79000 to 79777
89000 to 89777
99000 to 99777
E9000 to E9777
E1000 to E1777
File 1 to 7 : 000000 to 177777
※ Usable file number varies with memory module using for PC. (See page 13·21) ※
File 1 to 7 : 000000 to 177777
10
· "Writing mode assignment" is used to show whether writing to the PC memory has been enabled or disabled. 0: Writing prohibited 1: Enable writing only to data memory 2: Enable writing all data. No setting: Enable writing in any mode
10·6
Page 175
Read out current value of timer/counter/MD Function
Read out current value that specified timer/counter/MD
Command code
03(H) (MTC)
Writing mode assignment
No
Operation condition of PC
Unrelated
Letters in brackets are command name of BASIC mode.
Assignable address : When PC is except for JW50H/70H/100H 0000 to 0777(8) : When PC is JW50H/70H/100H 0000 to 0777(8)
Set/reset timer/counter (1 points unit) Function
Specify writing mode
Set (timeup, countup) or reset (return to setting value) that specified timer/counter Letters in brackets are 13(H) (SRT) command name of BASIC mode. 1 or 2
Operation condition of PC
Unrelated
Command code
Assignable address
10
: When PC is except for JW50H/70H/100H 0000 to 0777(8) : When PC is JW50H/70H/100H 0000 to 0777(8)
· "Writing mode assignment" is used to show whether writing to the PC memory has been enabled or disabled. 0: Writing prohibited 1: Enable writing only to data memory 2: Enable writing all data. No setting: Enable writing in any mode
10·7
Page 176
Read out current value of system memory (256 bytes max./one time) Function
Read out current value that specified system memory
Command code
04(H) (RSM)
Writing mode assignment
1 or 2
Operation condition of PC
Unrelated
Letters in brackets are command name of BASIC mode.
Assignable address When PC is ZW model
When PC is JW model
Segment 0 00000 to 00177(8)
Segment 0 00000 to 00177(8)
Segment 8 00200 to 00377(8)
Segment 8 00200 to 02177(8)
Write in system memory (256 bytes max./one time) Function
Write in manual data to specified system memory
Command code
14(H) (WSM)
Writing mode assignment
2
Operation condition of PC
Stopping
Letters in brackets are command name of BASIC mode.
Assignable address
10
When PC is ZW model
When PC is JW model
Segment 0 00000 to 00177(8)
Segment 0 00000 to 00177(8)
Segment 8 00200 to 00377(8)
Segment 8 00200 to 02177(8)
· "Writing mode assignment" is used to show whether writing to the PC memory has been enabled or disabled. 0: Writing prohibited 1: Enable writing only to data memory 2: Enable writing all data. No setting: Enable writing in any mode
10·8
Page 177
Read out program memory (512 steps max./one time) Function
Writing mode assignment
Read out contents that specified program memory using machine language. Letters in brackets are 05(H) (RPM) command name of BASIC mode. No
Operation condition of PC
Unrelated
Command code
Assignable address
When PC is ZW model 000000 to 076777(8)
Address varies with memory capacity.
When PC is JW50, JW50H 000000 to 016777(8) When PC is JW70/100, JW70H/100H 000000 to 076777(8), 100000 to 176777(8)
Write in program memory (512 steps max./one time) Function
Write in manual instruction words to specified program memory.
Command code
15(H) (WPM)
Writing mode assignment
2
Operation condition of PC
Stopping
Assignable address
Letters in brackets are command name of BASIC mode.
When PC is ZW model 000000 to 076777(8)
Address varies with memory capacity.
When PC is JW50, JW50H 000000 to 016777(8) When PC is JW70/100, JW70H/100H 000000 to 076777(8), 100000 to 176777(8)
· "Writing mode assignment" is used to show whether writing to the PC memory has been enabled or disabled. 0: Writing prohibited 1: Enable writing only to data memory 2: Enable writing all data. No setting: Enable writing in any mode
10·9
10
Page 178
Change the setting value of timer/counter (1 point unit) Function
Change the assigned value of the timer/counter to any value.
Command code
16(H) (CTC)
Writing mode assignment
2
Operation condition of PC
Unrelated
Assignable address
Letters in brackets are command name of BASIC mode.
When PC is ZW model Segment 8 000000 to 076777(8) When PC is JW model Segment 9 000000 to 076777(8)
10
· "Writing mode assignment" is used to show whether writing to the PC memory has been enabled or disabled. 0: Writing prohibited 1: Enable writing only to data memory 2: Enable writing all data. No setting: Enable writing in any mode
10·10