Page 1

16_Sec (065-096).qxd

07/28/03

03:24 PM

Page 16/78

Actuator-Sensor-Interface I/O Modules for Operation in the Control Cabinet (IP 20) SlimLine

■ Selection and ordering data Design

Description

Order No.

Price

Pack

1 unit

Unit

SlimLine S22.5 with screw-type terminals 3RK1 200-0CE00-0AA2

3RK1 100-1CE00-0AA2

4 inputs Standard slaves

4I

• 2-wire PNP transistor

3RK1 200-0CE00-0AA2

1

• 2- and 3-wire PNP transistor

3RK1 200-0CE02-0AA2

1

• 115 V input (AC)

3RK1 200-0CE00-0AC2

1

• 230 V input (AC)

3RK1 200-0CE01-0AC2

1

2 inputs/2 outputs PNP transistor 2-wire Standard slaves

2I/2O

3RK1 400-0BE00-0AA2

1

2 inputs/2 outputs relay outputs

2I/2OR

3RK1 402-0BE00-0AA2

1

4 outputs PNP transistor Standard slaves

4O

3RK1 100-1CE00-0AA2

1

• 2-wire

3RK1 200-0CG00-0AA2

1

• 2- and 3-wire

3RK1 200-0CG02-0AA2

1

SlimLine S22.5 with Cage Clamp terminals 3RK1 200-0CG00-0AA2

4 inputs PNP transistor Standard slaves

4I

2 inputs/2 outputs 2-wire PNP transistor Standard slaves

2I/2O

3RK1 400-0BG00-0AA2

1

2 inputs/2 outputs relay outputs

2I/2OR

3RK1 402-0BG00-0AA2

1

4 outputs PNP transistor Standard slaves

4O

3RK1 100-1CG00-0AA2

1

•1A

3RK1 400-1CE00-0AA2

1

•2A

3RK1 400-1CE01-0AA2

1

• 1 A, floating I/Os

3RK1 402-3CE01-0AA2

1

• 230 V

3RK1 402-3CE00-0AA2

1

• 115 V input (AC)

3RK1 402-1CE00-0AC2

1

• 230 V input (AC)

3RK1 402-1CE01-0AC2

1

3RK2 400-1FE00-0AA2

1

SlimLine S45 with screw-type terminals 3RK1 400-1CE00-0AA2

4 inputs/4 outputs Standard slaves PNP transistor

4 inputs/4 outputs Relay output Standard slaves

4 inputs/ 3 outputs 2A PNP transistor A/B slaves

16/78

4I/4O

4I/4OR

4I/3O

Discount Code: AS-Interface

Siemens Energy & Automation, Inc. Industrial Controls Catalog

Page 2

16_Sec (065-096).qxd

07/28/03

03:24 PM

Page 16/79

Actuator-Sensor-Interface I/O Modules for Operation in the Control Cabinet (IP 20) SlimLine

■ Selection and ordering data Design

Description

Order No.

Price

Pack

1 unit

Unit

SlimLine S45 with Cage Clamp terminals 3RK1 400-1CG00-0AA2

4 inputs/4 outputs Standard slaves PNP transistor

4I/4O

•1A

3RK1 400-1CG00-0AA2

1

•2A

3RK1 400-1CG01-0AA2

1

• 1 A, floating I/Os

3RK1 402-3CG01-0AA2

1

4 inputs/4 outputs relay output 230 V

4E/4AR

3RK1 402-3CG00-0AA2

1

4 inputs/ 3 outputs A/B slaves

4E/3A

3RK2 400-1FG00-0AA2

1

Accessories 3RP1 902

Push-in lugs for screw mounting (1 packg. = 10 units)

3RP1 903

10

8WA2 807

1

5 1 packg.

SlimLine opening tool for all devices with Cage Clamp terminals up to max. 1.5 mm2 conductor cross-section partly insulated

Siemens Energy & Automation, Inc. Industrial Controls Catalog

1 packg.

Sealable cap for protection against unauthorized addressing (1 packg. = 5 units)

Discount Code: AS-Interface

16/79

Page 3

16_Sec (065-096).qxd

07/28/03

03:24 PM

Page 16/80

Actuator-Sensor-Interface I/O Modules for Operation in the Control Cabinet (IP 20) SlimLine

■ Technical data SlimLine S22.5 with screw-type terminals 4 inputs

Slave type

2-wire

2- and 3-wire

115 V input (AC)

230 V input (AC)

PNP transistor

PNP transistor

3RK1 200-0CE00-0AA2

3RK1 200-0CE02-0AA2

3RK1 200-0CE00-0AC2

3RK1 200-0CE01-0AC2

≤ 270

≤60

Standard slaves

Operational voltage in accordance with AS-Inter- 26.5 ... 31.6 face specification in V Total current input in mA

≤ 50

Input connection

PNP

Inputs • Sensor supply via AS-Interface

Short-circuit and overload-proof

–

• Voltage range in V

20 ... 30

–

• Load rating for sensor supply in mA

–

200

–

• Connection of sensors

2-wire system

2- and 3-wire system

2-wire system

• Switching level High in V

≥ 10

≥ 10

≥ 79 AC / ≤ 135 AC

• Input current Low/High in mA

≤1.5/≥ 5

I/O configuration

0

ID/ID2 code

0/F

≥ 164 AC / ≤ 255 AC

≤1.5/≥ 6 F/F

Assignment of data bits • Data bit D0

IN1

• Data bit D1

IN2

• Data bit D2

IN3

• Data bit D3

IN4

AS-Interface certificate yes

Approvals

UL, CSA, ship building

Protection

IP 20

Ambient temperature in °C

–25 ... +85

Storage temperature in °C

–40 ... +85

Weight in g

150 in preparation

–25 ... +60 140

Displays • Inputs/outputs yellow LED

• AS-Interface green LED

• FAULT red LED

Connection via screw terminal

Note

To supply the output circuit, an external supplementary supply (AUX POWER) of DC 20 to 30 V is necessary. The supplementary supply must comply with VDE 0106 (PELV), safety class III.

16/80

Siemens Energy & Automation, Inc. Industrial Controls Catalog

Page 4

16_Sec (065-096).qxd

07/28/03

03:24 PM

Page 16/81

Actuator-Sensor-Interface I/O Modules for Operation in the Control Cabinet (IP 20) SlimLine

■ Technical data 2 inputs/2 outputs 2-wire

Slave type

4 outputs

PNP transistor

Relay outputs

PNP transistor

3RK1 400-0BE00-0AA2

3RK1 402-0BE00-0AA2

3RK1 100-1CE00-0AA2

Standard slaves

Operational voltage in accordance with AS-Inter- 26.5 ... 31.6 face specification in V Total current input in mA

≤ 50

≤40

Input connection

PNP

–

• Sensor supply via AS-Interface

Short-circuit and overload-proof

–

• Voltage range in V

20 ... 30

–

• Load rating for sensor supply in mA

–

• Connection of sensors

2-wire system

–

• Switching level High in V

≥ 10

–

• Input current Low/High in mA

≤1.5/≥ 5

–

Inputs

Outputs • Type of output

PNP transistor

Relay

Electronics (PNP)

• Current carrying capacity in A

2

–

1

• Short-circuit protection built-in external back-up fuse built-in

• Inductive interference protection built-in not applicable built-in

• Polarity reversal protection not built-in not applicable built-in

• External voltage supply DC 24 V via screw terminal Terminal 7 = "+" Terminal 10 = "-" not applicable via screw terminal Terminal 7 = "+" Terminal 10 = M

• Ith

–

6

–

• AC-15

–

3

–

• DC 13 24 V

–

1

–

• DC 13 110 V

–

0.2

–

• DC 13 230 V

–

0,1

–

Watchdog built-in

I/O configuration

3

ID/ID2 code

0/F

8

Assignment of data bits • Data bit D0

IN1

OUT1

• Data bit D1

IN2

OUT2

• Data bit D2

OUT1

OUT3

• Data bit D3

OUT2

OUT4

AS-Interface certificate yes

Approvals

UL, CSA, ship building

Protection

IP 20

Ambient temperature in °C

–25 ... +70

Storage temperature in °C

–40 ... +85

Weight in g

150

160 approx. 150

Displays • Outputs yellow LED

• AS-Interface green LED

• Diagnostics

– red LED

• FAULT red LED

–

Connection

Screw terminals

Note

To supply the output circuit, an external supplementary supply (AUX POWER) of DC 20 to 30 V is necessary. The supplementary supply must comply with VDE 0106 (PELV), safety class III.

Siemens Energy & Automation, Inc. Industrial Controls Catalog

16/81

Page 5

16_Sec (065-096).qxd

07/28/03

03:24 PM

Page 16/82

Actuator-Sensor-Interface I/O Modules for Operation in the Control Cabinet (IP 20) SlimLine

■ Technical data SlimLine S22.5 with Cage Clamp terminals 4 inputs

Slave type

2 inputs/2 outputs

2-wire

2- and 3-wire

2-wire

PNP transistor

PNP transistor

PNP transistor

3RK1 200-0CG00-0AA2

3RK1 200-0CG02-0AA2

3RK1 400-0BG00-0AA2

≤ 270

≤ 50

Relay outputs

3RK1 402-0BG00-0AA2

Standard slaves

Operational voltage in accordance with AS-Inter- 26.5 ... 31.6 face specification in V Total current input in mA

≤ 50

Input connection

PNP

Inputs • Sensor supply via AS-Interface

Short-circuit and overload-proof

• Voltage range in V

20 ... 30

• Load rating for sensor supply in mA

–

200

–

• Connection of sensors

2-wire system

2- and 3-wire system

2-wire system

• Switching level High in V

≥ 10

• Input current Low/High in mA

≤1.5/≥ 5

Outputs • Type of output

–

PNP transistor

Relay floating changeover contact

• Current carrying capacity in A DC 12 / DC 13 typ. (total current for all outputs 4 A)

–

2

–

• Ith

–

6

• AC-15

–

3

• DC 13 24 V

–

1

• DC 13 110 V

–

0.2

• DC 13 230 V

–

• Short-circuit protection

– built-in external back-up fuse necessary

• Inductive interference protection

– built-in not applicable

• Polarity reversal protection

– not built-in not applicable

• External voltage supply DC 24 V

– via terminals: Terminal 7 = "+" Terminal 10 = "-" not applicable

0,1

• Watchdog

– built-in

I/O configuration

0

3

ID/ID2 code

0/F

Assignment of data bits • Data bit D0

IN1

• Data bit D1

IN2

• Data bit D2

IN3

OUT1

• Data bit D3

IN4

OUT2

AS-Interface certificate yes

Approvals

UL, CSA, ship building

Protection

IP 20

Ambient temperature in °C

–25 ... +85

Storage temperature in °C

–40 ... +85

Weight in g

150

–25 ... +70 160

Displays • Inputs/outputs yellow LED

• AS-Interface green LED

• FAULT red LED

Connection

Cage Clamp terminals

Conductor cross-sections in mm2 solid: 2 × (0.25-1.5) finely stranded with end sleeve:2 × (0.25-1) finely stranded without end sleeve: 2 × (0.25-1.5) AWG conductors, solid or stranded: AWG 2 × (24-16)

Note 1

Opening tool for Cage Clamp terminals: See accessories

Note 2

To supply the output circuit, an external supplementary supply (AUX POWER) of DC 20 to 30 V is necessary. The supplementary supply must comply with VDE 0106 (PELV), safety class III.

16/82

Siemens Energy & Automation, Inc. Industrial Controls Catalog

Page 6

16_Sec (065-096).qxd

07/28/03

03:24 PM

Page 16/83

Actuator-Sensor-Interface I/O Modules for Operation in the Control Cabinet (IP 20) SlimLine

■ Technical data 4 outputs PNP transistor 3RK1 100-1CG00-0AA2 Slave type

Standard slaves

Operational voltage in accordance with AS-Interface specification in V

26.5 ... 31.6

Total current input in mA

≤40

Outputs • Type of output

Electronics (PNP)

• Current carrying capacity in A DC 12 / DC 13 typ. (max. 2 A per module)

1

• Short-circuit protection built-in

• Polarity reversal protection built-in

• Inductive interference protection built-in

• External voltage supply DC 24 V via screw terminal (terminal 7 = "+", terminal 10 = M)

Watchdog built-in

I/O configuration

8

ID/ID2 code

0/F

Assignment of data bits • Data bit D0

OUT1

• Data bit D1

OUT2

• Data bit D2

OUT3

• Data bit D3

OUT4

AS-Interface certificate yes

Approvals

UL, CSA, ship building

Protection

IP 20

Ambient temperature in °C

–25 ... +70

Storage temperature in °C

–40 ... +85

Weight in g approx. 150

Displays • Outputs yellow LED

• AS-Interface green LED

• Diagnostics red LED

Connection

Cage Clamp terminals

Conductor cross-sections in mm2 solid: 2 × (0.25-1.5) finely stranded with end sleeve: 2 × (0.25-1) finely stranded without end sleeve: 2 × (0.25-1.5) AWG conductors, solid or stranded: AWG 2 × (24-16)

Note 1

Opening tool for Cage Clamp terminals: See accessories

Note 2

To supply the output circuit, an external supplementary supply (AUX POWER) of DC 20 to 30 V is necessary. The supplementary supply must comply with VDE 0106 (PELV), safety class III.

Siemens Energy & Automation, Inc. Industrial Controls Catalog

16/83