Page 110
6
SIMATIC Human-Machine Interface Systems WinCC Integrated Human-Machine Interface Software
Page SIMATIC Human-Machine Interface, Introduction
6/2
Machine-level control and monitoring Operator panels OP7, OP17
6/3
Operator panels OP27, TP27, OP37, TP37
6/5
Cable Selection Guide
6/8
WinCC Integrated Human-Machine Interface Software, Introduction
6/10
Application, Function, Ordering Data
6/11
6
Siemens ST40
6/1
Page 111
SIMATIC human-machine interface systems Introduction
Introduction
The more complex automated processes become, the greater the need for process-oriented humanmachine communication. The SIMATIC HumanMachine Interface family is a perfected range of userfriendly human-machine interfaces (HMIs) suitable for use with SIMATIC 505 programmable controllers. The range extends from lowend operator panels to complete operator control and process monitoring systems with pixel-graphics capability.
The complete coordination between SIMATIC 505 and SIMATIC products and their full integration in the system substantially simplifies the application of these HMIs. Coordination
SIMATIC HMI systems can be connected directly to the SIMATIC 505 CPUs. Process control monitoring over large distances can be implemented with the PROFIBUS-DP bus system.
The SIMATIC 505 system is already integrated with the SIMATIC human-machine interface. The HMI system requests process data from the SIMATIC 505 programmable controller. Data transfer is controlled by the operating system; no additional user programming overhead is needed. System integration Numerous features, ranging from a unified database and symbology to the use of the same user-friendly Windowsoriented interface, simplify the use of HMI systems.
Operator panels (OP) For fast intervention right at the machine, e.g. to deal with faults.
These panels can be used to: ■ enter setpoints, ■ display machine data, and ■ modify machine-specific parameters.
6
6/2
Siemens ST40
Page 112
SIMATIC human-machine interface systems Introduction OP7, OP17 operator panels
The OP7 and OP17 operator panels are designed for machine operation and monitoring.
Application
They are easy to operate and user-friendly. Applications include: ■ Mechanical engineering applications ■ Packaging systems
The OP7 and OP17 can be connected to: ■ The SIMATIC S7-200,
S7-300/400 ■ The SIMATIC S5-90U through S5-135U ■ The SIMATIC 505 PLC systems. ■ Other PLCs.
■ Air-conditioning systems.
Design
The OP7 and OP17 operator panels incorporate the following features: ■ Degree of protection
NEMA4 (front panel) ■ Built-in flash EPROM for configuration data (128 Kbytes) ■
LED-backlit LCD
■
Membrane keyboard with 8 (OP7), 24 (OP17) function keys. OP7 Eight permanently labeled function keys which can be used as soft keys. Four function keys with LED’S
Function
The following functions are available to the user: ■ Display of process variables ■ Management and editing of status and fault messages ■ Date and time stamp in messages (both OP7 and OP17 have an internal real-time clock) ■ Definition of message priorities ■ Differentiation between first-up and last-up messages
OP17 24 user-labeled function keys with 16 LEDs. ■ Built-in interface ports for communications: OP7 1 x TTY/RS232C (v.24) 1 x RS485/RS422/MPI/PPI/ PROFIBUS DP; OP17 2 x TTY/RS232C (v. 24) 1 x MPI/PPI/PROFIBUS DP In addition to communications, the OP7 and OP17 also support simultaneous connection of a printer.
6 variables into a maximum of 99 logical groups (displays) ■ Infotexts for messages, displays, etc. ■ Alphanumeric setpoint entry with system keys ■ User-configurable printer listings
■ Soft keys ■ PLC tasks for triggering ■ PLC-controlled actions ■ Language selection ■ Contrast control ■ Printer connection via built-in TTY/RS232C (v. 24) interface.
■ Password protection ■ Input limit verification ■ User-programmable user menus
■ Classification of process
Siemens ST40
6/3
Page 113
SIMATIC human-machine interface systems Machine-level control and monitoring OP7, OP17 operator panels (continued)
Configuring
The SIMATIC ProTool/Lite software is available for configuring the OP7 and OP17 operator panels. The SIMATIC ProTool/Lite is a subset of SIMATIC ProTool. There are various constraints due to the functionality of the OP7 and OP17.
Ordering data
Order No.
OP7/PP operator panel OP7/DP operator panel OP7/DP-12 operator panel with mounting accessories, 128 Kbyte Flash EPROM and backup battery, with two built in interface ports (1XTTY/RS232C (V24), 1XRS485/422/MPI/PPI/ PROFIBUDP), LED - backlit LCD, 4lines, 20cpi, 8mm / .3 in font size.
6AV3 607-1JC00-0AX1 6AV3 607-15JC20-0AX1 6AV3 607-JC30-0AX1
OP17 operator panel with mounting accessories 128 kbyte Flash EPROM and backup battery OP17/PP operator panel OP17/PP operator panel OP17/DP-12 operator panel with three built-in interface ports (2 x TTY/RS232 C (V.24), 1 x MPI/PPI/PROFIBUS DP), adjustable LED-backlit LCD: 4 lines, 20 cpl, 8 mm / 0.31 in font size or 8 lines, 40 cpl, 4.5 mm / 0.18 in font size.
6
6AV3 617-1JC00-0AX1 6AV3 617-1JC20-0AX1 6AV3 617-1JC30-0AX1
All of the configuration data are stored in the operator panel memory, thereby off loading the programmable controller. There are no problems using existing configurations implemented with ProTool/Lite.
Please refer to Catalog ST 80.1 for further information.
Order No. OP7/17 manual Configured with ProTool/Lite Communications manual Description of how operator panels can be connected to programmable controllers. *German English French Italian Spanish
6AV3 991-1AE05-0AB0
Configuring software SIMATIC ProTool/Lite 4.0 for configuring the OP7 and OP17; Executable on PC’s using Windows 95 & Windows NT and higher; multilingual screen forms (available in German, English, French, Italian and Spanish); single license; on CD with configuring guide in *German English French Italian Spanish
6AV9 620-1BB07-1A ■ 0-T
PROFIBUS DP bus cable PROFIBUS DP bus connector for SIMATIC HMI OP; degree of protection IP 20, axial cable outlet.
See Catalog Siemens ST-70. 6GK1 500-0EA00
6AV3 991-1BQ00-0AA0 6AV3 991-1BC06-0AB0 6AV3 991-1BB00-0AC0 6AV3 991-1BB00-0AD0 6AV3 991-1BB00-0AE0
▲
A B C D E
Please refer to Catalog Siemens ST 80.1 or the SIMATIC HMI Order Guide for further information on connecting cables.
6/4
Siemens ST40
Page 114
SIMATIC human-machine interface systems Machine-level control and monitoring OP27, OP37 operator panels
Application
The OP27 and OP37 operator panels are designed for user-friendly machine operation and monitoring .
Applications include:
They can be used for the following tasks:
■ Air-conditioning systems.
■ Display of status and fault
■ Mechanical engineering ■ Packaging systems
The operator panels can be connected to:
messages and process variables:
■ The SIMATIC S7-200,
Process variables are visualized in various formats, such as output fields, bars, trends or status indicators.
■ The SIMATIC S5-90U
■ Menu-driven process control and monitoring, e.g. via input.
S7300/400 through S5-135U ■ The SIMATIC 505
(PLC 525,535,545,555, 565T) ■ PC systems (free serial link) ■ Other PLCs.
Operators can use soft keys, function keys and system keys to enter set-points, control actuators, etc.
Design
The OP27 and OP37 operator panels incorporate the following features: ■ Rugged die-cast aluminum housing with membrane front panel ■ Degree of protection NEMA
4 (front panel) ■ Low mounting depth ■ Built-in flash EPROM for firmware and user data ■ Membrane keyboard:
Keys resistant to oil, grease and commercial cleaning agents.
Function
The following functions are available to the user: ■ Display of process variables ■ Management and process- ing for status and fault messages ■ Language selection (three on-line languages) ■ Printer connection through built-in interface port ■ Printing functions:
hard copy, message printout
Siemens ST40
■ CCFL-backlit LCD
Communications through:
OP27 Monochrome, or color resolution 320 x 240 pixels
■ The built-in programming
OP37 Color, resolution 640 x 480 pixels
■ The built-in PROFIBUS-DP device (PG) port of the 505 programmable controller. port on appropriate 505 programmable controllers
■ Built-in interface ports for communications: 4 interfaces1: 1 x TTY (active/passive.)/ RS232C (v.24), 1 x TTY (passive/ RS232C (v.24), 1 X.27/TTY (passive), 1 x MPI/PPI.
■ Process control using soft
■ Password protection (also keys, function keys or system keys for individual functions)
■ Dynamic fields:
e.g. input/ output fields, shapes, bars and trends
■ Static symbols can be
■ Recipe management.
The OP37 also has the following features: ■ Color LCD (passive), TFT option incorporated into process displays (in character or pixel graphics mode)
■ Higher resolution:
■ Infotexts for messages and
■ Extended operator variables ■ Evaluation of machine status (masking out of dynamic fields, displays, etc. as a function of a given variable)
640 x 480 pixels functions provided by extra soft keys and function keys ■ Diskette drive.
6/5
6
Page 115
SIMATIC human-machine interface systems Machine-level control and monitoring OP27 and OP37 operator panels (continued)
Configuring
Windows-based SIMATIC Human-Machine Interface ProTool configuring software. The Windows-based SIMATIC ProTool software is available for configuring the OP7,17,27,37,and TP27,37 operator panels. The configuration data are entered on a programming device (PG) or PC, stored on hard drive or diskette and then transferred to the RAM of the operator panel. During configuration, there is no need for a connection between the PG or PC and the operator panel (off-line programming). A cable is used to connect the PG to the operator panel for data transfer.
Hardware requirements:
■ Configuring of character- graphics and pixelgraphics symbols
The SIMATIC ProTool configuring software includes the following features:
■ Importing of pixel-graphics
■ Windows 95 & NT
■ Verification of all inputs compatibility:The operator control philosophy and the layout of the user interface are Windows-oriented ■ Pixel-graphics configura- tion in off-line mode ■ Mouse-supported configur- ing interface ■ Enhanced presentation with drop-down menus
6
Fig. 6/1 SIMATIC ProTool configuring software. Configuring interface as a classic Windows application.
objects ■ Cross-reference lists ■ Integrated on-line help system
SIMATIC ProTool can be run on PCs (minimum configuration: Pentium processor, 16 Mbtyes on the Windows 95 drive), VGA graphics card, Windowscompatible pointing device (e.g. mouse , lightpen), and Windows 95 & NT, or higher. Recommended configuration: Pentium processor, 16 Mbyte RAM, hard drive with 40 Mbytes free, graphics card with Windows accelerator chip, mouse.
■ Clear documentation of configuration data ■ Clearly presented default forms ■ Pixel-graphics printout of process displays.
■ Fast access to functions using standardized and editor-specific icons ■ Object-oriented symbolic programming Technical specifications Operator panel
OP27
Supply voltage
18 to 30 V DC
Power consumption (without option) • at 24 V DC, typ. • at 24 V DC, max.
0.4 A 0.6 A
0.8 A 1.0 A
• RAM
2 Mbyte flash EPROM (on board) 4 Mbytes
4 Mbyte flash EPROM (on board) 8 Mbytes
Clock
Hardware clock
Memory • Firmware/user/memory
1
OP37
Operator panel
OP27
OP37
Display • Resolution
LCD (passive), 320 x 240 pixels Monochrome or color
CCFL-backlit 640 x 480 pixels color,TFT or STN
• Active area (W x H) in mm/in • MTBF background lighting1
115 x 86/ 4.49 x 3.35 25,000 h
192 x 144/ 7.49 x 5.62 25,000 h
Keyboard • System keys • Soft keys • Function keys • Direct keys (24 V)
Membrane keyboard 24 14 10 8 (optional)
32 20 16 12 (optional)
Diskette drive
No
Optional
For further information, see Order Guide ST 80.
6/6
Siemens ST40
Page 116
SIMATIC human-machine interface systems Machine-level control and monitoring OP27 and OP37 operator panels (continued) Technical specifications (continued) Operator panel
OP27
OP37
4
Interfaces • Serial interface SS 1
TTY/20 mA (active/passive); RS 232C (V.24) TTY/20 mA (passive); RS232C (V.24) X.27 (RS4221A/485); TTY (passive) MPI (S7-300), PPI (S7-200) No No
• Serial interface SS 2 • Serial interface SS 3 • Serial interface S7 • Keyboard (MFII) Message system • Status messages max. • Fault messages max. • Length of message text max. (lines x characters) • Variables per message max. • Infotext per message max. • Status/fault message buffer Process displays • Number • Character graphics • Symbol sets/ character sets. • Pixel graphics • Dynamic objects max.
Ordering data OP27 operator panel3 with 4 built-in interface ports4 (2 x TTY/RS232C (v.24), 1 x X.27/TTY, 1 x MPI/PPI), mounting accessories, backup battery, 2 Mbyte flash EPROM • Basic unit
1 2
20001 20001 2 x 35
1 x 70
8 7 x 35 characters Circular buffer able to hold 512 entries
OP27
Infotext for input fields
7 x 35 characters
Recipes • Records per recipe2 • Entries per record On-line languages Password levels Configuring tool max. max. max. max.
Degree of protection Dimensions in mm/ in • Front panel (W x H) • Panel cut-out (W x H x D)
Depends on RAM space Yes 4 Yes, direct access to external editor e.g. input fields, output fields, I/O fields, date/time fields, symbolic I/O fields, bars, curves, shapes, etc.
Ambient temperature Non-operating temperature Relative humidity max.
Order No.
6AV3 627-1JK00-0AX0
6AV3 637-1LL00-0AX0 6AV3 637-1ML00-0AX0
OP27/OP37 manual • German • English • French • Italian • Spanish
6AV3 991-1AK00-0AA0 6AV3 991-1AK00-0AB0 6AV3 991-1AD00-0AC0 6AV3 991-1AD00-0AD0 6AV3 991-1AD00-0AE0
Depends on user memory Data memory available for records; max. 64 Kbytes.
OP37
2551 5001 5001 3 9 SIMATIC ProTool configuring software running under MS Windows, V3.1 or later NEMA 4 296 x 192/ 482 x 310/ 11.54 x 7.49 18.79 x 12.09 282 x 178 x 59 / 436 x 295 x 85/ 11 x 6.94 x 2.3 17 x 11.5 x 3.32 (with direct (with direct keypad module keypad module, and connecting diskette drive and cable connecting cable D= 79 mm/3.08) D= 158mm/6.16 0 to 50 ˚C/ 4 to 45 ˚C/ 32 to 122 ˚F 40 to 113˚F -20 to -60 ˚C / 50 to 140 ˚F 85%, no permissible condensation
Order No. Communications manual Guide for connecting operator panels to programmable controllers; English
OP37 operator panel with 4 built-in interface ports4 (2 x TTY/RS232C (v.24), 1 x X.27/TTY, 1 x MPI/PPI), mounting accessories, backup battery, 4 Mbyte flash EPROM with passive STN color LCD • Basic unit3 • with active TFT color LCD
Siemens ST40
Operator panel
SIMATIC HMI ProTool configuring software for configuring the OP3/5/7/17/27/ 35, TP27/37, and TD17 (with 8 Mbytes RAM) on PCs; multilingual screen forms (German, English, French, Italian or Spanish); on CD ROM single license with configuring guide in German English French Italian Spanish
6AV3 991-1BC06-2AB0
6AV9 620-1AA07-1A■ 0T ▲
6 A B C D E
Connecting cables
See Catalog Siemens ST-70.
PROFIBUS-DP bus cable
SeeCatalog Siemens ST-70.
PROFIBUS-DP bus connector for SICOMP PCs and OPs; degree of protection IP 20, axial cable outlet
6GK1 500-0EA00
3
Subject to the following export regulations; AG: N; AL: –; EC: B; and ECCN: 4D96G. 4 Not usable simultaneously
6/7
Page 117
SIMATIC human-machine interface systems Interface Cable Selection Guide Selection of the OP and the PLC Cable
The OPs require different hardware for different PLCs to communicate to. Use the table below by finding the PLC that you wish to connect the OP to, read across the columns to find the appropriate OP that is being used, and read the cable part number in the box where the two intersect. For example, to find the cable between an OP25 and a SIMATIC 545 (RS 232) PLC, locate the PLC in row 4, locate the OP25 in OP column 6, and read the cable number 6XV1 4402KH32. If the box is empty, the communication option is not available.
Communications Table for TD17, OP3/5/7/15/17/25/27/37 & TP27/37 For this OP ➾ Communicate to:
OP3
OP5 A1 OP15 C1
OP5 A2 OP15 C2
OP7/PP OP17/ PP
OP7/DP OP17/ DP
➾
Siemens SIMATIC S7-200 PPI Port
6ES7 7050AA00-7BA01
6ES7 9010BF00-0AA01
6ES7 9010BF00-0AA01
6ES7 9010BF00-0AA01
Siemens SIMATIC S7-300/400 MPI Port
6ES7 7050AA00-07BA01
6ES7 9010BF00-0AA01
6ES7 9010BF00-0AA01
6ES7 9010BF00-0AA01
6XV1 4402AH32
6XV1 4402AH32
Siemens SIMATIC 545/555 RS232 Port
6XV1 4402KH32
6XV1 4402KH32
Siemens SIMATIC 545/555 RS422 Port
6XV1 4401MH323
6XV1 4401MH323
Siemens SIMATIC 525/535/565 RS232 Port
6XV1 4402LH32
6XV1 4402LH32
Siemens SIMATIC S5 Programming Port
Siemens SIMATIC S5/505/S7 L2-DP (1.5MB)
6XV1 4402AH32
6GK1 5000EA004
6GK15000EA004
6GK15000EA004 6GK15000EA004
Siemens SIMATIC S5/505/S7 L2-DP (12MB)
6
TD17 OP7/DP-12 OP17/DP-12 OP25/27/37 TP/2737
Allen-Bradley SLC 5/03-04 DF1 RS232 Port
6XV1 4402KH32
6XV1 4402KH32
Allen-Bradley PLC5 DF1 RS232 Port
6XV1 4402LH32
6XV1 4402LH32
Allen-Bradley PLC5 DF1 RS422 Port
6XV1 4402LH32
6XV1 4402VH32
Mitsubishi FX/FX0 RS232 Port
6XV1 4402PR32
6XV1 4402PR32
Mitsubishi FX/FX0 RS422 Port
6XV1 4402RH32
6XV1 4402RH32
AEG Modicon MODBUS RS232 Port
6XV1 4401KH32
6XV1 4401KH32
Telemecanique TSX17 RS485 Port2
6XV1 4401EH32
6XV1 4401EH32
Telemecanique TSX 47/67/87/107 RS485 Port
6XV1 4401EH50
6XV1 4401EH50
1
This is a point to point cable with no additional socket. To use standard MPI cable refer to the ST70 catalog. This will allow multiple devices to be connected to the S7-300/400 PLC. 2 This is for ADJUST or UNI-TELWAY 3 This is for a 545-1102 CPU. For 545-1101 CPU’s use 6XV1 440-2MH32 4 This is the bus connector only with no additional socket. L2 cable must be ordered separately. Note: S5 AS511 OP communication is not supported by all S5 CPU’s. To communicate to these CPU’s use SIMATIC S5 FAP. Affected CPU’s are: • 115U-945 • all 155U processors Contact Technical Services at 1-800-333-7421 for cabling information for these CPU’s. 6/8
Siemens ST40
Page 118
SIMATIC human-machine interface systems Machine-level control and monitoring SIMATIC HMI
Technical specifications Operator panel
TP27
TP37
Display Resolution (pixels) display dimension color
STN 320 x 240 5,7” monochrome (8grey levels) or color (8 col.)
TFT 640 x 480 10,4” color (8 colors)
Keyboard type Virtuell keyboard for alpha-inputs LED display
Touch (matrix) yes -
Touch (analog/resistive) yes 4 (Power/HD Busy/Disk/Temp)
Processor
80486 / 33 Mhz
Pentium / 100MHz
Memory Flash firmware/configuring (Mbyte) D-RAM (Mbyte) S-RAM (battery backup, Kbyte)
1 2 128
2 8 128
Port for external keyboard Port for mouse
IF1/A:TTY (active/passive), RS232-C IF2: TTY (active/passive), RS232-C IF3: IF1/B: RS-422, RS-485 LPT1:-
IF1/A:TTY (active/passive), RS232-C IF2: TTY (active/passive), RS232-C IF3: RS-422, RS-485, TTY (passive) IF1/B: RS-422, RS-485 LPT1: TTL (parallel) backwards PS2 backwards PS2
Power Supply Current
0,4 A/0,7 A at 24 V
24 V DC (18...30 V, prot. ag. rev. voltage)
Hardware clock yes (battery backup)
1,3 A/2,0 A at 24 V
Protection front/back
IP65/IP20 yes (battery backup) IP65/IP20
Dimensions [mm] front plate W x H cut out dim. W x H x D
212 x 156 203 x 147 x 65
335 x 275 ca. 310 x 248 x 123
Enviroment temperature • operation (vert. mounted) • operation (hor. mounted) • transportion/storage Humidity
0 to +50˚C 0 to +40˚C -20 to +60˚C < 85% non-condensing
+4 to +45˚C not possible 0 to +60˚C < 95% non-condensing
Interfaces typ./max.
Features Alarm system event messages alarm messages messages length (lines x char.) number of registers per message help texts with messages message buffer Recipes number of recipes recipe memory (Kbyte) data records per recipe entries per data record Screens number of screens pixel graphic symbol graphic character fonts dynamic objects
All numbers listed below represent the maximum-number for the individual features. The total number is limited by the size of the User Memory 2000 2000 2 x 35 8 7 x 35 char. 512 messages in FIFO
6
255 Maximum 448 flash (plus maximum 384 Kbyte submodule) 500 500 help texts with inputs
300 importing pixel graphic objects from standard drawing packages during configuration yes 1/3 Input, Output, Input-Out-put, Date, Time, Symbolic Input, Symbolic Output, Analog representation such as bargraphs and trends, etc. 7 x 35 char.
Online languages Password levels
3 9 max.
Configuration software
SIMATIC ProTool, runs under MS Windows 95
Ordering data Description TP 27 Touch Panel With 3 built-in interface ports 1x RS232C, 1xTTY, 1x MPI/422/485 Mono: Color: TP37 Touch Panel With 4 built in interface ports 2x TTY/RS232C, 1xTTY, 1x MPI/PPI/422/485 Active TFT Color:
Siemens ST40
Part Number
6AV3 627-1NK00-0AX0 6AV3 627-1QK00-0AX0
6AV3 637-1PL00-0AX0
6/9
Page 119
WinCC Integrated Human-Machine Interface Software Introduction Introduction
• Windows NT4.0 and Windows 95 look and feel • IHMI- Integrated Human Machine Interface • Interfaces for all major PLC manufacturers • Easy to use editors • Integrates your applications quickly • Multi-lingual on-line language switching enables worldwide use • Worldwide Siemens service and support • Serial drivers for all SIMATIC PLCs standard
Of course it’s open
Simply the best
While the industry searches for standards, Siemens again jumps to the front of the class. WinCC easily integrates into your new or existing system, and is a powerful, basic component for any automation system.
Siemens offers a native visualization system based on the latest technology, including Windows NT 4.0 and Windows 95. The true 32-bit processing system allows multi-tasking with other applications, responding quickly and efficiently to events and alarms. Plus the data integrity is among the best in the business.
WinCC - A custom solution Since every automation system is different, WinCC was designed to be flexible to fit your needs. Start with the core program, and link individual applications to the WinCC function modules. Configuration is easy, and you have a solution that works for you. Flexible and efficient We know your plant is dynamic, so we’ve built in expansion modules and scaleable software to make it easy to modify your application. WinCC provides across-theboard flexibility, regardless if the application is for a single user or complex, multi-user systems.
6
6/10
Easy to use With the integration of the Microsoft Win 95 GUI (Graphical User Interface), WinCC is intuitive and easy to use. Using WinCC and its powerful tools, you can reduce development time. And your new operators will be experts with the system quickly.
Use it everywhere - from machine construction to process automation Because you need a truly integrated HMI, WinCC was designed to work in process automation, production automation and in machine construction. Its features are unmatched by the competition. So take a few minutes and check out the following pages to get the details on why WinCC is the IHMI you’ve been looking for. All in all, this means that WinCC is a universal tool, totally flexible and extremely powerful. And because WinCC takes most of the burden off your shoulders, you can give your full concentration to your other automation tasks!
Transparent to the automation system WinCC makes both the process and production transparent. It shows current states and archive variations. The graphics function modules link individual programs and allow you to see messages, measured values, recipes and reports.
Siemens ST40
Page 120
SIMATIC Human-Machine Interface Software Application
Application
Of course you expect more from a market leader, and Siemens makes sure you have that edge. We’ve set up the WinCC hotline to answer your questions about the product, and also provide on-site service. 1-800-333-7421
Technical Specifications WinCC can execute on ATcompatible computers with a 486 or Pentium processor. The table on the left shows what you need for running WinCC under Windows 95 and Windows NT 4.0.
Hardware Table for WinCC WinCC for Windows95: Hardware Requirements Minimum CPU
Recommended
Main Memory
32 MB
32 MB
Graphics
SVGA
SVGA (2 MB)
Hard disc (EIDIE) Others
Remarks
Pentium
500 MB Free Disk Space 200MB
CD-ROM
Load, Multimedia
WinCC for WindowsNT 4.0: Hardware Requirements Minimum CPU
Recommended
Remarks
Pentium
Multiprocessor Computing (MPC) - for enhancing the performance of WinCC Server: 32 MB, depending on the number of data points
Main Memory
32 MB
32 MB
Graphics
SVGA
SVGA (2 MB)
Hard disk (SCSI)
200 MB
500 MB Free Disk Space
Server: 1GB, Archiving
CD-ROM MOD, EOD Streamer
Load, Multimedia Archiving
Others
6
Client/Server Recommended
Remarks
Client
Minimum
Pentium
Windows95 or WindowsNT 4.0 workstation
Server
WindowsNT 4.0
Pentium
Siemens ST40
6/11
Page 121
WinCC Integrated Human-Machine Interface Software Function, Ordering Data Function, Ordering Data (continued)
Function
WinCC has a variety of drivers available for major control platforms. Standard with all WinCC packages Item # Ordering Data are drivers for SIMATIC S5, S7, and 505, as well as DDE.
Part Number #
Base Software Packages Runtime 128 Tags Runtime 256 Tags Runtime 1024 Tags Runtime 64K Tags Runtime & Development 128 Tags Runtime & Development 256 Tags Runtime & Development 1024 Tags Runtime & Development 64K Tags
6AV6 3811BC040AX0 6AV6 3811BD040AX0 6AV6 3811BE040AX0 6AV6 3811BF040AX0 6AV6 3811BM040AX0 6AV6 3811BN040AX0 6AV6 3811BP040AX0 6AV6 3811BQ040AX0
Powerpack Tag Upgrades Powerpack RT - 128 to 256 Tags Powerpack RT - 128 to 1024 Tags Powerpack RT - 128 to 64K Tags Powerpack RT - 256 to 1024 Tags Powerpack RT - 256 to 64K Tags Powerpack RT - 1024 to 64K Tags Powerpack RT+D - 128 to 256 Tags Powerpack RT+D - 128 to 1024 Tags Powerpack RT+D - 128 to 64K Tags Powerpack RT+D - 256 to 1024 Tags Powerpack RT+D - 256 to 64K Tags Powerpack RT+D - 1024 to 64K Tags
6AV6 3711BD000BX0 6AV6 3711BE000BX0 6AV6 3711BF000BX0 6AV6 3711BG000BX0 6AV6 3711BH000BX0 6AV6 3711BJ000BX0 6AV6 3711BD100BX0 6AV6 3711BE100BX0 6AV6 3711BF100BX0 6AV6 3711BG100BX0 6AV6 3711BH100BX0 6AV6 3711BJ100BX0
Drivers ALLEN - BRADLEY - DF1 ALLEN - BRADLEY - Comb. (sol.) GE - SNP / SNPX Mitsubishi MELSEC FX MODICON - ModBus SIMATIC 505 - Ethernet L4 SIMATIC 505 TCP/IP SIMATIC PROFIBUS-DP SIMATIC S5 - Ethernet L4 SIMATIC S5 - Ethernet TF SIMATIC S5/S7 - PROFIBUS-FMS
6AV63711CD040BX0 6AV63711CD040GX0 6AV63711CD040EX0 6AV63711CD040RX0 6AV63711CD040DX0 6AV63711CD040MX0 WINCCDVR505TCPIP 6AV63711CD040UX0 6AV63711CD040KX0 6AV63711CD040LX0 6AV63711CD040CX0
Options WinCC Redundancy WinCC User Archives WinCC Server Option
6
6AV63711EF040AX0 6AV63711CB040AX0 6AV63711CA040AX0
Miscellaneous WinCC Manuals WinCC Upgrade Ver 3.1 to 4.0 WinCC Lunch & Learn 128 RT&C WinCC System Integrator Program
6/12
6AV63921XA040AB0 WINCCUG40 WINCCPACK40 WINCCSYSINT40
Siemens ST40