Siemens Catalog ST 40 for the SIMATIC 505 controller family: CPUs, racks, power supplies, I/O modules, networking and ordering data.

What this file really is

The old site listed this file as a manual for the Siemens 505-4232-A, 505-4832 and 3 more models. This is the Siemens SIMATIC 505 controllers product catalog (Catalog ST 40), not a user manual for the 505-4832 module.

Download the PDF3.9 MB

Names · 3 models

The models it names

Filed with · 2 models

Also filed with these models on the old site

Summary

What is in it

Siemens product catalog for the SIMATIC 505 programmable controllers. It describes the 505 system (controllers, I/O communications and mounting racks, power supply units, digital and analog I/O modules and special modules), SIMATIC NET networking with PROFIBUS, Industrial Ethernet and TIWAY, PROFIBUS-DP distributed I/O (ET 200 family), programming software, operator panels and WinCC, ordering data, connectivity data and CE marks. Modules such as the 505-4832, 505-4232-A, 505-6516, 505-6660 and 505-6851-A appear in its tables.

Its parts

  1. 1 Introduction
  2. 2 505 System
  3. 3 SIMATIC NET Industrial Communications
  4. 4 PROFIBUS-DP Distributed I/O
  5. 5 Software
  6. 6 SIMATIC Human-Machine Interface Systems
  7. 7 Ordering Data

From the manual

Key facts from this manual

Each line names its page in the PDF.

Siemens catalog ST 40 for the SIMATIC 505 controller family (525, 535, 545, 555 and 575), not a manual for a single module. It lists specifications and order numbers for 505 CPUs, I/O bases, power supplies, I/O and special modules and remote base controllers, among them the 505-6660, 505-6516, 505-6851-A, 505-4232-A and 505-4832, along with PROFIBUS networking, distributed I/O, software and operator panels. It helps the reader pick and order parts and see how local, remote and PROFIBUS-DP I/O systems connect.

Read for this summary: pages 1 to 2, 16 to 28, 122 to 124 and 127 to 131 of 139.

Document
Siemens catalog ST 40: SIMATIC 505 controllers, I/O, networking, distributed I/O, software and operator interfaces p. 1
505-6851-A
505-6851-A: RS485 remote base controller, installed in a remote I/O base and wired with shielded twisted pair, up to 1000 m (3,300 ft.) from the PLC p. 20, 129
505-6660
505-6660: 110/220 VAC power supply; every 505 power supply listed is rated 60 W; fuse kit 3 A/250 V, 5 pack, for 505-6660 p. 21, 124, 127
505-6516
505-6516: 16-slot I/O base, one of the 4, 8 and 16 slot bases for local I/O p. 127
Operating temperature
0 to 60 °C (IEC 68-2-14); up to 95% relative humidity, non-condensing p. 17
Remote I/O distance
Coaxial remote base controllers up to 4000 m from the PLC rack; shielded twisted-pair ones up to 1000 m p. 20
Remote base controllers
505-6851-A (RS485), 505-6850-A (coax), 505-6860 (coax to RS-485 converter), 505-6870 (PROFIBUS-DP RBC) p. 20
PROFIBUS-DP
Built into most 505 CPUs; up to 112 slaves; 100 m at 12 Mbaud, 1200 m at 9.6 Kbaud; 244 bytes in and 244 bytes out per node p. 20
Distributed I/O (535)
535 only: I/O channel controller 505-6830 and up to 14 distributed base controllers 505-6840, last one up to 396 m (1300 ft.) away p. 20
Fuses
Kits of five 3 A/250 V fuses for 505-48xx and 505-46xx modules; 3 A/125 V for 505-45xx p. 124
Programming software
505 TISOFT p. 124

What this manual walks you through

  • Choosing a 545, 555 or 575 CPU by memory, I/O count and PID loops p. 18, 19
  • Connecting 505 controllers to distributed, remote and PROFIBUS-DP I/O p. 20
  • Selecting digital, relay, analog and thermocouple/RTD I/O modules p. 22, 23, 24
  • Selecting counter, word I/O, simulator, BASIC and fieldbus interface modules p. 25, 26, 27
  • Ordering CPUs, bases, power supplies, modules, manuals, batteries and fuses p. 123, 124
  • Laying out local, distributed, remote and PROFIBUS-DP I/O systems p. 127, 128, 129, 130
  • Mounting 505 bases in a rack or on a wall p. 131

Good to know

  • SIMATIC 505 special function modules do not work with the PROFIBUS-DP remote base controller. p. 20
  • A 575 CPU takes either the 505 remote I/O annex card or the PROFIBUS-DP annex card, not both. p. 19
  • The distributed I/O system is used only by the 535 PLC. p. 20
  • The 575 VMEbus base must be mounted and run horizontally. p. 131

Questions this manual answers

What is the Siemens 505-6851-A?

An RS485 remote base controller that sits in a 505 remote I/O base and links it to a 545, 555 or 575 controller over shielded twisted pair. p. 20, 129

How far can SIMATIC 505 remote I/O bases be from the controller?

Up to 4000 m with coaxial remote base controllers and up to 1000 m with shielded twisted-pair ones. p. 20

What input voltage does the 505-6660 power supply take?

The catalog lists it as a 110/220 VAC power supply; the 505-6663 is the 24 VDC one. p. 127

How many slots does the 505-6516 base have?

16 slots. p. 127

How long can a 505 PROFIBUS-DP cable be?

Up to 100 meters at 12 Mbaud and up to 1200 meters at 9.6 Kbaud, farther with repeaters. p. 20

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Tttle page1
  2. 1 Introduction2
  3. 2 505 System16
    1. Introduction17
    2. Controllers18
    3. I/O Communications, Mounting Racks20
    4. Power Supply Units21
    5. I/O Modules22
    6. Special Modules27
    7. Application, Function28
    8. SIMATIC 575 CPU Memory29
    9. Description and Ordering Data30
  4. 3 SIMATIC NET Industrial Communications32
    1. Introduction33
    2. PROFIBUS bus components36
    3. Interface modules for PROFIBUS43
    4. Industrial Ethernet bus components50
    5. Interface modules for Industrial Ethernet56
    6. TIWAY Communications network61
  5. 4 PROFIBUS-DP Distributed I/O62
    1. Introduction63
    2. ET 200M64
    3. IM 153 Interface module for ET 200M68
    4. Configuring ET 200M69
    5. ET 200B71
    6. ET 200L77
    7. ET 200L-SC81
    8. Configuring ET 200L, ET 200L-SC (continued)88
    9. PROFIBUS-DP Interface IM SC89
    10. ET 200L complete system90
    11. ET 200X91
    12. Dimensional diagrams ET 200L, 200X-SC, SIMATIC SC, IM SC101
    13. SIMATIC Net DP/AS-Interface Link 20102
    14. DP/AS-Interface link (IP67)104
  6. 5 Software106
    1. TISOFT107
    2. SoftShop ™108
    3. APT109
  7. 6 SIMATIC Human-Machine Interface Systems110
    1. SIMATIC human-machine interface systems111
4 more lines, from page 119 on
  1. WinCC Integrated Human-Machine Interface Software119
  2. 7 Ordering Data122
  3. A - Connectivity Data126
  4. B - C.E. Marks132

From the PDF’s own bookmarks.

The whole text · 16 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 151-15
  2. 2 505 System, pages 16 to 2316-23
  3. 2 505 System, pages 24 to 3124-31
  4. 3 SIMATIC NET Industrial Communications, pages 32 to 4132-41
  5. 3 SIMATIC NET Industrial Communications, pages 42 to 5142-51
  6. 3 SIMATIC NET Industrial Communications, pages 52 to 6152-61
  7. 4 PROFIBUS-DP Distributed I/O, pages 62 to 7062-70
  8. 4 PROFIBUS-DP Distributed I/O, pages 71 to 7971-79
  9. 4 PROFIBUS-DP Distributed I/O, pages 80 to 8880-88
  10. 4 PROFIBUS-DP Distributed I/O, pages 89 to 9789-97
  11. 4 PROFIBUS-DP Distributed I/O, pages 98 to 10598-105
  12. 5 Software106-109
  13. 6 SIMATIC Human-Machine Interface Systems110-121
  14. 7 Ordering Data122-125
  15. A - Connectivity Data126-131
  16. B - C.E. Marks132-139

The file

Revision and size

RevisionCatalog ST 40, 1998
PublisherSiemens Energy and Automation, Inc.
Pages139
PDF3.9 MB
TextText from the PDF itself; page 122 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 139

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 139
Page 2
Page 2of 139
Page 3
Page 3of 139