Page 32

3

SIMATIC NET Industrial Communications

Page

The following section provides an overview of Siemens’ SIMATIC NET components and capabilities. Please refer to the SIMATIC NET Catalog IK10 for complete details and additional products available.

Siemens ST40

SIMATIC NET, Introduction

3/2

PROFIBUS bus components

3/5

Interface modules for PROFIBUS

3/12

Industrial Ethernet bus components

3/19

Interface modules for Industrial Ethernet

3/25

TIWAY Communications network

3/30

3/1

3

Page 33

SIMATIC NET Industrial communications Introduction

Introduction

Productivity in manufacturing greatly depends on the flexibility of the automation systems used. It is easier to keep large plants that extend over wide areas flexible if they are controlled by a number of distributed automation systems. And distributed control requires good data communications. Bus systems have proven to be the most economical solution in large industrial plants. They offer the following advantages: ■ Reduced cabling costs

■ Communications over a single data bus. The field-proven SIMATIC NET bus-type networks are used to network SIMATIC 505 programmable controllers.

SIMATIC NET industrial communications offers its users the following networks providing increasing levels of performance: ■ AS-Interface, an open technology for connection of actuators and sensors to an intelligent bus sytem.

Features of the SIMATIC networks: ■ Compliance with national and international standards ■ Designed for industry ■ Open systems: automation

■ PROFIBUS EN 50170, for low-end and mid-range applications. ■ Industrial Ethernet components from other vendors can be integrated into the communications network.

to ISO standards (Ethernet; IEEE 802.3), for the topend performance range. For further information, see Catalog IK 10.

■ Easy expandability

AS-interface (AS-i) The AS-Interface is a networking system for binary sensors and actuators at the lowest field level. Process signals originating on site are usually transmitted to the controller using extensive parallel wiring and input/output modules. This means that each sensor or actuator is

3 connected to the input/ output modules with its own cable.

A significant feature of the AS-Interface technology is the use of a common, unshielded two-wire cable for data transmission and distribution of auxiliary power to sensors/actuators.

AS-Interface allows replacing of this wiring harness by a simple two-wire cable commonly used by all sensors or actuators.

SIMATIC 505 CPU

PROFIBUS-DP

DP/AS-Interface LINK 20

Passive module (without slave ASIC)

Active module (with slave ASIC)

AS- Interface power supply

Repeater

AS-Interface power supply

Actuator/sensor (with slave ASIC)

1)

Actuator/Sensor (without Slave-ASIC)

AS- Interface cable

Feeder (without AS-Interface chip)

Fig. 3/1

3/2

1) As of now, extenders cannot be used.

The SIMATIC 505 can easily collect data of an AS-i bus using a DP/AS-i link.

Siemens ST40

Page 34

SIMATIC NET Industrial communications Introduction PROFIBUS system

PROFIBUS (Process Field Bus) is the network provided by Siemens to address the needs of field level communications.

PROFIBUS-DP

PROFIBUS

DTE

DTE

DTE

R

By meeting the requirements of the European standard EN 50170, Vol.2, PROFIBUS ensures open connectivity of components and conformance with products from other manufactures.

DTE high-speed communications with distributed I/Os

■ PROFIBUS-PA

( Process automation) A powerful protocol profile based on PROFIBUS-DP with an intrinsically safe transmission system complying with international standard IEC 1158-2. PROFIBUS uses several transmission methods: ■ Electrical, via twisted-pair cables (RS-485 technology) ■ Optical, with glass or plastic fiber conductors; immune to electromagnetic noise and suitable for use over large distances. PROFIBUS electrical: • Stations connected by bus terminals or bus connectors; individual segments are interconnected by repeaters. • Maximum range: 1200 m / 3936 ft without repeaters, 9600 m/ 31,488 ft. with repeaters (depending on data transfer rate).

DTE

O L M

Repeater

Bus terminal

Fig. 3/2

DTE

O L M

O L M

DTE

O L M

Two-wire cable

■ PROFIBUS-DP for peer-to-peer communications.

O L M

DTE

R

■ PROFIBUS-FMS for universal

O L M

DTE

O L M

Fiber optic cable O L M

Optical Link Module (OLM)

DTE

Data Terminal Equipment

Sample configuration for a PROFIBUS network

• Glass or plastic-fiber cables as optical waveguides. • Maximum length of network roughly 100 km / 62.5 miles (max. distance between two OLMs: 15 km / 9.37 miles with the OLM/S-1300 using monomode fiber). The main features of PROFIBUS are:

controllers • Field devices with PROFIBUS interfaces, e.g. ET 200 • SIMATIC HMI systems (COROS®) • Drives, SIMOCODE motor protection devices • SIMATIC PC industrial computers and SINUMERIK CNCs

■ Configuration per EN 50170 ■ 127 nodes;

up to 32 of these nodes - programmable controllers, programming devices and PCs, for example - can be active

■ Software-selectable data transfer rate (9.6 to12,000 Kbps). The following equipment can be networked: • SIMATIC 505 programmable controllers • SIMATIC S7-300 and S7-400 programmable controllers

In addition to the available standard, we offer additional communication functions on the same PROFIBUS network. ■ The SIMATIC S7 functions for optimized communications with HMI applications and S7-300/400 PLCs. ■ Communication function blocks (CFBs), for simple data block transfers to S5 and S7-300/400 PLCs (SEND/RECEIVE interface).

• SIMATIC S5 programmable

PROFIBUS optical: • Star, ring or linear bus topologies via optical link modules (OLMs).

Siemens ST40

3/3

3

Page 35

SIMATIC NET Industrial communications Introduction

Industrial Ethernet bus system

The access method used by the Industrial Ethernet network is CSMA/CD (carrier sense multiple access with collision detection), as standardized in IEEE 802.3 (Ethernet). To enable you to use a well-known Ethernet communication on the factory floor, we offer reliable and FM rated equipment as well as an extended shielding/grounding concept ( i.e. Industrial Ethernet.) Industrial Ethernet offers a number of transmission options: ■ Industrial Ethernet electrical:

The Industrial Ethernet electrical bus network uses triaxial cable (50 ohms) as its transmission medium.

3

Industrial Twisted Pair is a type of double-shielded

Fig. 3/3 twisted-pair cable which is especially well suited for industrial applications, and which is offered as an adjunct and alternative to conventional bus cabling for the connection of data terminal equipment. ■ Industrial Ethernet optical:

The optical variant of Industrial Ethernet cable uses fiber-optic cable as its transmission medium and is based on a star topology. The Industrial Ethernet electrical network and optical network can be mixed. The following equipment can be connected to the Industrial Ethernet network: • SIMATIC 505 controllers

• SIMATIC S5 controllers • PCs and PGs • Certified systems of other manufacturers. The SIMATIC network communicates with the SIMATIC 505 by the following methods: ■ Open communication by means of SIMATIC-TF (technological functions)1. ■ Communication via TCP/IP protocol for easy interconnection of SIMATIC 505 devices and for hook-ups to PCs and HMI systems. The necessary functions are already present in the CP operating system.

• SIMATIC S7-300 and S7-400 controllers

Mixed Industrial Ethernet configuration

1

Communications are configured on the Communications Processor (interface) and invoked from the user application program in the PLC.

3/4

Siemens ST40

Page 36

SIMATIC NET Industrial communications PROFIBUS bus components PROFIBUS cables

Application

Ordering data Electrical cable 2-wire, shielded; Sold by the meter: maximum unit size: 1000 m / 3280 ft. Minimum order: 20 m / 65.6 ft. • bus cable • buried cable • trailing cable

PROFIBUS cables are supplied for the connection of SIMATIC networks.

Double shielding makes them especially well suited for installation in industrial environments with high levels of electromagnetic interference.

Order No.

6XV1 830-0AH10 6XV1 830-3AH10 6XV1 830-3BH10

Order No.

• Bus cable with PE sheath for the food industry

6XV1 830-0BH10

• Bus cable for suspended cabling

6XV1 830-3CH10

• Bus cable halogen free (flame retardant)

6XV1 830-0CH10

For further information see Catalog IK 10.

3

Siemens ST40

3/5

Page 37

SIMATIC NET Industrial communications PROFIBUS bus components PROFIBUS fiber-optic cables

Application

PROFIBUS fiber-optic cables are supplied for the connection of optical networks.

These fiber-optic cables are available with glass or plastic optical fiber conductors:

■

Trailing glass fiber-optic cable for indoor and outdoor applications

Standard glass fiber-optic cable for indoor and outdoor applications

■

Plastic fiber-optic cable for indoor applications, for PROFIBUS optical networks only.

■

For further information see Catalog IK 10.

3

Ordering data

Order No.

SIMATIC NET glass fiber-optic cable standard format, splittable, pre-terminated with 4 BFOC socket connectors

6XV1 820-5B ■ ■ ■*

SIMATIC NET flexible fiber-optic cable trailing format, splittable, pre-terminated with 4 BFOC socket connectors

6XV1 820-6B ■ ■ ■

BFOC socket connectors for fiber-optic cable Specify standard or trailing

6GK1 901-0DA20-0AA0

Order No.

▲ ▲ ▲

▲ ▲ ▲

Indoor fiber optic cable Indoor fiber optic cable, splittable precut/preassembled with 4BF0C connectors

For order information see Catalog IK 10.

CUPOFLEX BFOC PVC simplex cable PVC, UL 3.6 mm/ 0.14 in for OLM/P single-fiber rings Max. length 65 m / 213.2 ft.

5DX8 021-8AA ▲■ ▲■

CUPOFLEX BFOC PVC twin cable, UL 3.6 mm/ 0.14 in for OLM/P networks in bus and star topologies Max. length 65 m/213.2 ft.

5DX8 031-8AA ▲■ ▲■

BF0C pigtail set 2 x 50 m set of 2 connectors, plastic FO cable with one BFOC connector fitted at one end for connecting OLM/P to OLP.

6XV1 830-6BN50

Non-precut/assembled cables CUPOFLEX simplex PVC UL 2.2 mm core for OLM 12M or OLP single-fiber ring

5DX6 312-4AA01

CUPOFLEX duplex PVC UL 2.2 mm core for OLM12M networks in in-line and star structure.

5 DX6 322-4AA01

*For length key, see following page

3/6

Siemens ST40

Page 38

SIMATIC NET Industrial communications PROFIBUS bus components Length data on SIMATIC NET glass fiber-optic cable and SIMATIC NET PROFIBUS plastic connecting cable

Length key

Glass fiber-optic cable Length in m = Multiplication factor x length number

Plastic connecting cable Order No. Extension

Length in m = Length number

Order No. Extension

6XV1 . . .-. . ■ ■ ■

5DX8 . . .-. . ■ ■

▲ ▲ ▲

Multiplication factor

Length number

0.1 m/.33 ft 1 m/3.28 ft 10 m/32.8 ft 100 m/328 ft 0. 1. 2. 3. 4. 5. 6. 7. 8. .0 .1 .2 .3 .4 .5 .6 .7 .8

H N T U

▲ ▲

Length number (m)

0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8

Lengths containing the number 9 are not permitted.

0. 1. 2. 3. 4. 5. 6. 7. 8. .0 .1 .2 .3 .4 .5 .6 .7 .8

0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8

3

Lengths containing the number 9 are not permitted.

Maximum length: 650 m / 2132 ft. Example Length 160 m/ 525 ft.

SIMATIC NET glass fiber-optic cable

Siemens ST40

Terminated glass fiber-optic cable is available in the following increments, depending on the total length:

6XV1 . . .-. . T16

Example Length 50 m/ 164 ft.

5DX8 . . .-. . . 50

Total length

Increment

1 m to 20 m / 3.28 ft to 65.6 ft >20 m to 50 m / 65.6 ft. to 164 ft >50 m to 100 m / 164 ft. to 328 ft >100 m to 500 m / 328 ft. to 1640 ft >500 m to 1000 m / 1640 ft. to 3280 ft

1 m / 3.28 ft 2 m / 6.56 ft 5 m / 16.4 ft 10 m / 32.8 ft 50 m / 164 ft

3/7

Page 39

SIMATIC NET Industrial communications PROFIBUS bus components RS 485 IP 20 repeater for data transfer rates of up to 12 Mbps

Application

Design

3

The RS-485 IP 20 repeater connects two PROFIBUS bus segments to a maximum of 32 stations using RS-485 technology. It expands the data transfer rate capability of PROFIBUS to include speeds of 3, 6 and 12 Mbps.

■

Repeater in IP 20 housing

■

■

Two terminal blocks for segment connection

Terminal block for power supply (24 V DC, external)

■

Interface for PGs and PCs

Ordering data

Order No.

RS-485 IP 20 repeater 24 V DC, IP 20 housing; for data transfer rates of up to 500 Kbps

6GK1 510-0AC00

RS-485 IP 65 repeater 24 V DC, IP 65 housing; for data transfer rates of up to 500 Kbps

6GK1 510-0AD00

The maximum permissible segment length for these additional data transfer rates is 100 m / 328 ft.

■

Rotary switch for data transfer rate adjustment

Order No. RS-485 IP 20 repeater 24 V DC; for data transfer rates of up to 12 Mbps

6ES7972-0AA00-0XA0

For further information see Catalog IK 10.

PROFIBUS ILM (infrared link module)

■

Wireless PROFIBUS link for all protocols

■

Sturdy construction features IP 65 (NEMA 4)

■

15 m (49 ft.) range

Fig. 3/4 PROFIBUS ILM

Application

3/8

■

Wirelss transmission of PROFIBUS data at close ranges (< 15 m) (49 ft)

■

Links individual nodes within one segment or links two segments.

■

Communicates with mobile nodes e.g. automated guided vehicle system (AGVS)

■

Communicates with changing peers, e.g. stations located in conveyors or production lines.

■

Lets you establish installations quickly. Convenient if installation is only temporary (e.g., for test installations.

■

Replaces systems that are subject to wear, e.g. collector rings and brushes.

Siemens ST40

Page 40

SIMATIC NET Industrial communications PROFIBUS bus components PROFIBUS ILM

Design

■

Sturdy cast aluminum housing features IP 65 degree of protection

■

2x2-pole terminal block located in housing (cable led through heavy gauge conduit thread) provides connection for PROFIBUS segment.

■

4-pole terminal block located in housing (cable led through heavy duty conduit connectors) for supply voltage (DC 24 V), and signalling contact.

■

Stationary wiring, which lets you replace electronic equipment fast if a fault occurs.

■

Status display uses LED’s to show operating status.

■

Set transmission rate with interior switch.

■

Protected against interfering ambient light by integrated natural light filter.

■

Simple alignment procedure with flat cover (+ 10˚ angles)

System configuration (monomaster operation)

3

Fig. 3/5 Link to mobile nodes

Fig. 3/6 Link to varying nodes

Fig. 3/7 Links two segments

Ordering data see attached order data only

Siemens ST40

Ordering data

Order No.

PROFIBUS ILM Infrared Link Module, lets you link PROFIBUS nodes and segments without cables

6GK1 503-0AA00

3/9

Page 41

SIMATIC NET Industrial communications PROFIBUS bus components PROFIBUS Optical Link Modules (OLMs)

Application

The PROFIBUS optical link modules can be used to: ■

Design

The PROFIBUS OLMs feature: ■

A 9-pin subminiature D socket and 2-pin terminal block for connecting bus segments via an RS-485 interface

■

An optical/electrical converter

3

Configure PROFIBUS optical networks of bus, simple ring and star topology

■

Interconnect PROFIBUS electrical and optical networks

■

Construct PROFIBUS redundant fiber optic rings

■

One (3-channel module) or two (4-channel module) fiber-optic conductor interface pairs with standards BFOC socket connectors (ST-compatible) for connecting fiber-optic conductors.

The OLMs are available for both glass-fiber and plasticfiber conductors. They come in two versions: ■

Three-channel module for linking two PROFIBUS segments via fiber-optic conductors using RS-485 transmission technology or for configuring simple ring topologies

■

Four-channel module for configuring bus or star topologies or redundant optical rings.

The OLMs snap onto a DIN rail, or flush mount using machine screws.

Ordering data

Order No.

PROFIBUS L2 OLM/P3 Optical link module for plastic fiber-optic conductors 3-channel version

6GK1 502-3AA10

PROFIBUS L2 OLM/S4 Optical link module for glass fiber-optic conductors 4-channel version

6GK1 502-4AB10

PROFIBUS L2 OLM/P4 Optical link module for plastic fiber-optic conductors 4-channel version

6GK1 502-4AA10

PROFIBUS L2 OLM/S3-1300 Optical link module for glass fiber-optic conductors, for long distances, 3-channel version

6GK1 502-3AC10

PROFIBUS L2 OLM/S3 Optical link module for glass fiber-optic conductors 3-channel version

6GK1 502-3AB10

PROFIBUS L2 OLM/S4-1300 Optical link module for glass fiber-optic conductors, for long distances, 4-channel version

6GK1 502-4AC10

Order No.

For further information, see Catalog IK 10.

3/10

Siemens ST40