The text of a manual · part 6 of 16
SIMATIC 505 Controllers, Catalog ST 40: 3 SIMATIC NET Industrial Communications, pages 52 to 61
Pages 52 to 61 of 139, from SIMATIC 505 Controllers, Catalog ST 40
The original document is the PDF (3.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Siemens 505-6660, Siemens 505-6851-A and Siemens 505-6516
Page 52
SIMATIC NET Industrial communications Industrial Ethernet bus components Ordering data
Order No.
SIBUKO Package 2 with transceiver (one interface), mounting equipment and mounting guide German, English, French
6GK1 100-0AB00
Order No. SIBUKO Package 6 with transceiver (two interfaces), mounting equipment and mounting guide German, English, French
6GK1 100-0AJ00
For further information see Catalog IK 10.
SIMATIC NET industrial twisted-pair plug-in transceiver Application
Devices that do not have a built-in industrial twisted-pair transceiver but do have an AUI interface can be connected to the twistedpair network by means of TPTR. The CP 1434 can be directly connected to an industrial
Design
■
AUI interface for connection to the terminal: 15-pin sub-D plug connector.
Ordering data
Order No.
Industrial twisted-pair plug in transceiver (TPTR) for connecting an industrial twisted pair cable to the AUI interface of a terminal
6GK1 100-0BA00
■
MDI (medium dependent interface) for connecting the twisted-pair cable: 15-pin sub-D socket connector with slide lock.
twisted-pair network using the TPTR. The TPTR is plugged into the device’s AUI interface. The 15-pin sub-D plug connector of the industrial twisted-pair cable can then be connected to the sub-D socket connector of the TPTR.
■
3
6 Diagnostic LEDs.
For further information see Catalog IK 10. SIMATIC NET SSV 104 fan-out unit SIMATIC NET SSV 104 fanout unit serves to connect up to 8 terminals or communication processors to an Ethernet network via a SIMATIC transceiver or to the SIMATIC fiber optic network via an optical transceiver.
Application
Design
Ordering data SIMATIC SSV 104 fan-out unit with 8 interfaces
■
Built to the specifications of IEEE 802.3
■
8 AUI interfaces
■
Can be used as • desktop unit or • 19“ rack mount.
Order No. 6GK1 104-0AA00
For further information see Catalog IK 10.
Siemens ST40
3/21
Page 53
SIMATIC NET Industrial communications Industrial Ethernet bus components SIMATIC NET OTDE (BFOC) optical transceiver
Application
The SIMATIC NET MINI OTDE optical transceiver is used to connect a terminal to an optical network and to configure a fiber-optic link between two terminals. The CP 1434 can be directly connected to an optical
Design
3
■
Optical interface: two BFOCs/2.5 socket connectors (ST-compatible)
Ordering data
Order No.
MINI OTDE (BFOC) optical transceiver for connecting a terminal (CP), fan-out unit or repeater to a fiber-optic cable
HIR:943 303-021
■
Connection: Fiber-optic cable containing gradedindex fiber (type 62.5/125 mm; compatible with IEEE network using the MINI OTDE. The MINI OTDE can be plugged directly into the terminal’s AUI interface. It can be permanently installed by means of the wall mounting and connected with 727-1 dropcable.
802.3 FOIRL) directly connectable to the ECFL2 fiber-optic interface card of an ASGE star coupler. Order No.
Wall mounting For the MINI OTDE
HIR:943 426-001
For further information see Catalog IK 10. OLM and ELM for Industrial Ethernet
• Optimum configuration of the topology (linear, ring, star) • High availability can be achieved with redundant power supply and redundant ring structure. • Rapid and simple installation (standard DIN rail) and easy startup. • Function monitoring via signalling contact. • Repeater functional features. Fig. 3/16
Application
SIMATIC NET link modules for industrial Ethernet enable the flexible, low-cost assembly of Ethernet LANs in compliance with IEEE 802.3, with fiber-optic cables and coppers conductors. The link modules are suitable for operation in a system with distributed connection density.
3/22
OLM and ELM
The link modules offer multiple connection options in one unit. The OLMs (optical link modules) have both electrical and optical interfaces; the ELMs (electrical link modules are a version with only electrical interfaces.
Used in Ethernet LANs, the link modules support both linear structures (with OLMs or ELMs via fiber optic or industrial twisted-pair (ITP) cables and reduncant optical ring structures (with OLMs only, via fiber optic ports).
Siemens ST40
Page 54
SIMATIC NET Industrial communications Industrial Ethernet bus components OLM and ELM for Industrial Ethernet (continued)
Design
Network Topologies
Electrical interface of the OLM and ELM:
ELM electrical AUI interface:
• 3 x 9 -pin sub D female connectors for ITP cables.
• via 727-1 connecting cable and fan-out unit
OLM optical interface:
• via TPTR to ITP
• 2 x BFOC female connectors for glass fiber
• via MINI-OTDE to the optical network
The 24 V supply is provided via a terminal block. Redundant power supply configurations are supported.
Various network structures can be implemented with the OLMs/ELMs:
• Combination of OLMs/ ELMs with star couplers (max. cascading depth and residual cable length depend on configuration).
* OLM’s and ELM’s can be directly interconnected with the ITP cascading cable (1m long) via an industrial twisted-pair.
• Linear structures with OLMs or ELMs via fiber optic or ITP cables (LAN expansion depends on cascading depth 1)) • Redundant ring structure with OLMs or ASGE star coupler via fiber-optic ports (LAN expansion depends on cascading depth).
OLM
ELM
Diagnostics
Electrical ITP AUI signaling contact 3 –– 1 3 1
1
The signaling contact can be used to relay a digital signal to controllers or humanmachine interface systems for evaluation.
• Purly electrical structures with ELMs (LAN design according to configuration rules). • Combination of OLMs/ELMs in fiber optic and coaxial segments (LAN design according to configuration rules).
3
Optical
BFOC connectors 2x2
––
LEDs are provided for diagnostics and indicate the following events: • Collisions in the Ethernet LAN • Receipt of data packets • Link status (no error, error, standby in redundant systems)
Siemens ST40
Connection
1) max. 11 OLM in line or ring configuration, extension of the topologies with Multi LAN switch MR 8-03 for line and star structures. LAN planning must always take into account the rules in the manual of “ITP Networks for Industrial Ethernet” and the “Ethernet” Manual.
The signal contact is activated as soon as at least one of the following errors occurs: • Long-term faults in the module
Signaling of the statuses can be masked port-wise via a switch. A fiber-optic port can also be switched to the redundant mode.
• Failure of at least one of the two power supplies • Link status of at least one fiber optic or ITP port faulty.
3/23
Page 55
SIMATIC NET Industrial communications Industrial Ethernet bus components OLM and ELM for Industrial Ethernet (continued)
ITP cascading cable 6XV1 850-2CH10
727-1 connecting cable 6ES5 727-1xxxx
ELM
727-0 LAN cable 6ES5 727-0AA11
Data terminal equipment (DTE) e.g. PLC, PC, HMI, etc.
OLM
OLM
ITP connecting cable 6XV1 850-2Bxxx or wiring cable 6XV1 850-0Bxxx 1)
OLM
ITP connecting cable 6XV1 850-2Bxxx or wiring cable 6XV1 850-0Bxxx 1)
OLM
Fiber optic cable 6XV1 820-5Bxxx INDOOR fiber optic cable 6XV1 820-7Bxxx
1)
3
Fig. 3/17
Depending on length
Example of system configuration with OLMs and ELM for Industrial Ethernet
Ordering data
Order No.
Ordering data
Order No.
OLM for Industrial Ethernet Optical link module with 3 ITP ports and 2 FO ports; redundant power s upply and signaling contact
6GK1 102-4A00
ELM for Industrial Ethernet Electrical link module with 3 ITP ports and 1 AUI port; redundant power supply and signaling contact.
6GK1 102-5AA00
ITP cascading cable for Industrial Ethernet for cascading of link modules
6XV1 850-2CH10
The active star couplers constitute the star branch points of SIMATIC ETHERNET in conformity with IEEE 802.3. Their modular design permits flexible network configuration using different transmission media such as
SIMATIC 727-0 bus cable (triaxial), Industrial twistedpair cable and Fiber-optic cable or 727-1 connecting cables.
For further information see Catalog IK 10
SIMATIC NET ASGE active star coupler
Application
The optical signals are regenerated completely in the star coupler.
For further information see Catalog IK 10 1998, page 5/24.
3/24
Siemens ST40
Page 56
SIMATIC NET Industrial communications Interface modules for Industrial Ethernet SIMATIC 505-CP2572 Ethernet TCP/IP communications processor The SIMATIC 505-CP2572 Ethernet TCP/IP Adapter is a single wide I/O module serving as a LAN (Local Area Network) interface module for SIMATIC 505 PLC’s (Programmable Logic Controllers). The 505-CP2572 provides connectivity to Ethernet local area networks and allows the PLC to communicate with other network nodes using the transmission ControlProtocol/Internet Protocol (TCP/IP). Using the 505-CP2572, other devices Connectable systems • SIMATIC 505 (CPUs 525, 535, 545, 555, 565 and 575) Design • The SIMATIC 505 CP2572 plugs directly into the basic unit or an expansion unit and requires one slot. • Date interchange via TCP/IP (Ethernet Transmission Control Protocol/Internet Protocol) • Use as server and client • Diagnostic utilities provided • RFC-1006 Protocol for communications with S7 PLC’s (Available soon) • Provides two serial ports which function as additional PLC program ports (NITP protocol) for the local PLC or another PLC on the network. The ports may be used to configure the module. • Full set of front panel diagnostic LEDs • 2 front terminals for external power supply for AUI interface Functions The SIMATIC 505 CP2572 communications processor independently handles data traffic via Industrial Ethernet. The CAMP and NITP protocols are supported. Seen from the PLC, the SIMATIC 505 CP2572 is considered as a special on the network can acquire data from the PLC, send data and programs to the PLC, and exercise supervisory control over the PLC operation. In addition, the PLC can use the facilities of the 505-CP2572 to send messages to another node on the network. The 505-CP2572 attaches to all Ethernet media specified by IEEE 802.3 including 10Base5 (“thick” coaxial cable), 10Base2 (“thin” coaxial cable), module occupying 2 input words and 6 output words in the CPU address area. Data blocks (V memory) can be transferred via the Ethernet LAN to other stations. Remote programming over the LAN is possible
10BaseT (unshielded twisted-pair cabling), and FOIRL (fiber optic cable). 10baseT cabling can be attached directly to the 505-CP2572 via an 8-pin (RJ-45) modular jack. Other IEEE 802.3 media may be connected to the AUI (Attachment Unit Interface) port, a user supplied transceiver. The transceiver can be powered externally to conserve PLC backplane power.
• In Serial Redirect Mode, the module routes data received at a serial port on the module to another node on the network. For example, a PC running TISOFT could download programs to other PLC’s on the network. Configuring The 505-CP2572 module itself requires no customer programming. All configuration options can be set by module switches and a serially attached personal computer. Optionally, PLC logic can control the operation of the module, if desired. In order for a PC to communicate with the 505-CP2572 module, install an application software package on the PC. Contact your distributor for details.
SIMATIC 505 - CP2572
Technical specifications
Transmission rate Interfaces Ethernet Ports
10 Mbit/s
3
1-EEE 802.3 10BaseT, 8 pin Modular Jack (RJ-45) 1-EEE 802.3 AUI, female DB-15 connector
• In Server Mode, the module responds to PLC commands embedded in the TCP/IP packet. • In Client Mode, the module can initiate a TCP/IP message with another node on the network. Client activity is the basis of peer-to-peer communications.
Fig. 3/18
10BaseT port auto-selected if link Beat is present. AUI power derived from PLC backplane or external power supply Serial Ports
1-RS 232C (subset), male BD9 connector, DTE 1-RS-422, female DB9 connector
Supply voltage
Power consumption (via backplane bus) • +5 V DC • 12 V DC Construction • Module format • Dimensions (W x H x D) in mm • Weight • Space requirement
+5 DC (via backplane bus) +12 V DC (via front terminals for AUI) 6 W (without AUI) 0.5 W (standard AUI) double Eurocard 20 x 266 x 170 0.3 kg 1 slot
Ordering data SIMATIC 505-CP505-CP2572 including configuring software and manual SIMATIC 505-CP2572 manual Connecting Cable for direct connection of a programming device/PC to the CP (needed to configure the module
PPX:505-CP2572
505-8132-1 PPX:2601094-8001
See Catalog IK10 for further information
Siemens ST40
3/25
Page 57
SIMATIC NET Industrial communications Interface modules for Industrial Ethernet SIMATIC 505-CP1434 TF Ethernet communications processor
Designed for Industry • Handling of message communication up to and including Layer 7 of the ISO 7-layer model • The CP1434-TF fully relieves the PLC of communications tasks. • Interfaces:, TF/MMS interface (Layer 7), Transport interface (Layer 4), PC/PG interface • Remote configuring over the LAN
3
Connectable systems
Functions
• SIMATIC 505 (CPUs 525, 535, 545, 555, 565 and 575)
The SIMATIC 505 CP1434-TF Ethernet communications processor independently handles data traffic over the Industrial Ethernet.
Design • The CP1434-TF Ethernet communications processor plugs directly into a basic unit or expansion unit; it requires two slots.
Seen from the PLC, the SIMATIC 505 CP1434-TF is considered as a special module occupying eight input and eight output bytes in the CPU address area.
• 15-pin sub-D female connector for connection to Industrial Ethernet via transceiver with the 727-1 connecting cable
All types of variables as well as data blocks can be transferred via Ethernet to other stations.
• 9-pin RS-232/423 male connector for connection to PCs and programming devices
10 Mbit/s
Interfaces • for Industrial Ethernet • for PG/PC
15-pin sub-D female 9-pin RS 232/423 male
Supply voltage
+/-5V; (via backplane bus)
Permissible ambient conditions • Operating temperature • Transportation and storage temperature • Relative humidity Construction • Module format • Dimensions (W x H x D) in mm • Weight • Space requirement Configuration software
3/26
SIMATIC NET AP is used for Layers 5 to 7a; the technological functions are available for Layer 7b. • Communication using the TF protocol • Simple data interchange between SIMATIC PLCs
Configuring Transport links, application links and the parameters required for handling the technological functions are configured on a PC/PG, using configuring software based on MS-DOS WIndows. The configuration data is stored in the RAM of the CP or in the EEPROM.
• Remote programming over the LAN is possible.
Ordering data
Transmission rate
• -5 V DC reference model are implemented on the module. Layers 1 to 4 comply with international standards.
All 7 layers of the ISO
Technical specifications
Power consumption (via backplane bus) • +5 V DC
Fig. 3/19 SIMATIC 505 - CP1434-TF Ethernet communications processor
22 W (jumper E1 fitted) 10 W (jumper not fitted) 0.1 W 0 to 60 ˚C -40 to +70 ˚C 5% to 95%
SIMATIC 505-CP1434-TF including configuring software and manual
PPX:505-CP1434-TF
SIMATIC 505-CP1434-TF on a 3 1/2" floppy disk configuring software for MS-DOS/Windows
PPX:505-CONF1434-2
SIMATIC 505-CP1434-TF manual English Connecting cable for direct connection of programming device/PC to the CP
PPX:505-8126-2 PPX:201094-8001 double Eurocard 40 x 266 x 184 0.4 kg 2 slots SIMATIC 505-CP1434-TF configuring software
Siemens ST40
Page 58
SIMATIC NET Industrial communications Interface modules for Industrial Ethernet Industrial Ethernet System connection for PC/PG CP 1413 (ISA) HARD NET
SOFT NET
• CP with its own microprocessors
• Multiprotocol; up to 2 protocols can be operated simultaneously for
– SEND/RECEIVE – PG functions
• Protocol software runs on the CP
– TF
• Additional PC networks can be operated
– MAP
• Real-time synchronization
• PC/host is relieved of communications tasks
– S7 functions
CP 1411 (ISA)
• Single protocol
CP 1511 (PCMCIA)
–S7 functions
• CPs without microprocessors
– SEND/RECEIVE
• Entire protocol software runs on the PC/host (Loading of the host)
– PG functions • Additional PC networks can be operated
CP1413 communications processor • Loadable firmware • Multi-protocol capability • Interfaces for – TF – MAP
Various packages with different software are available. A changeover to another operating system, for example, is possible with the same hardware using conversion packages.
– S7 functions – SEND/RECEIVE • Communications software for MS-DOS, Windows 3.11, Windows 95, Windows NT and UNIX
System interfacing to: • AT-compatible PCs • SIMATIC programming devices
Ordering data TF interface TF-NET1413/MS-DOS, Windows consisting of CP 1413 and TF-1413/MS-DOS, Windows German/English TF-1413/MS-DOS, Windows Software for TF protocol and PG functions including configuring software, runs on CP 1413 under MS-DOS from V5.0 and Windows from V3.0 on 3 1/2” floppy disk German/English TF-NET1413/Windows 95 consisting of CP 1413 and TF-1413/MS-DOS, Windows German/English
• via a transceiver for the electrical LAN • via a plug-in transceiver (TPTR) for ITP or
Two protocols can be operated simultaneously.
• via the optical transceiver MINI OTDE for an optical LAN.
Design
Functions
The CP 1413 plugs directly into the SIMATIC programming device or an AT-compatible PC, and requires a short slot.
The hardware and firmware on the module independently handle Layers 1 to 7a of the SIMATIC NET protocol. Additionally contained in the module are configuring, test and LAN management functions. Data interchange between module and host memory takes place via a dual-port RAM. The data transfer between host
• ISA Card • 15-pin sub D female for connection to Industrial Ethernet.
system and CP 1413 is handled by operating system-related interface drivers. Communications in the SIMATIC NET system are carried out using the technological functions or S7 functions.
Figure 3/20 CP1413
Order No.
Ordering data
Order No.
6GK1 141-3AE00
TF-1413/Windows 95 Software for TF protocol and PG functions including configuring software, runs on CP 1413, under Windows 95 on CD-ROM German/English
6GK1 701-1TH41-3AA0
TF-NET1413/Windows NT consisting of CP 1413 and TF-1413 Windows NT 4.0 and PG functions including configuring software German/English
6GK1 141-3TB11
TF-1413/Windows NT Software for TF protocol including configuring software, runs on CP 1413, under under Windows NT 4.0 on CD-ROM German/English
6GK1 701-1TB41-3AA0
6GK1 701-1AA00-0EA0
6GK1 141-3TH11
For further software options, see Catalog IK 10. Siemens ST40
The module is connected to the 727-0 LAN cable
3/27
3
Page 59
SIMATIC NET Industrial communications Interface modules for Industrial Ethernet CP 1511 communications processor
• PCMCIA card for industrial Ethernet
• Executable with SOFTNET packages and PC networks
• Allows connection of PG 720 to Industrial Ethernet
• PG functionality
• Interfaces for
System interfacing to:
– AUI – industrial twisted pair – RJ 45 (for office applications)
• SIMATIC PGs with PCMCIA port • Notebooks with PCMCIA slot
Fig. 3/21 CP 1511 with adaptor
Design
3 Functions
The CP 1511 can be operated in any computer with a slot complying with the PCMCIA 2.0 standard. Two adapters are supplied. One adapter is designed for connection to RJ 45, and the other one provides a connection to triaxial cable (AUI) and an industrial twisted pair.
It has the following interfaces:
The CP 1511 is an Ethernet card which can be operated in any programming device/PC with a free PCMCIA Type II slot.
SOFTNET S5 and SOFTNET PG for Industrial Ethernet contain ODI drivers for the CP 1511.
The CP 1511 offers the following accesses: • Layer 2: Interfacing for PC networks in an industrial enviroment.
• 15-pin sub D female for AUI connection. • 15-pin sub D female for industrial twisted pair. There are no jumpers on the module; it can be configured entirely by software.
In conjunction with all SOFTNET packages for Industrial Ethernet (except UNIX) the CP 1511 can be used in a PG 720 for remote programming (PG functions).
• Ebene 4 und Ebene 7: In conjunction with the SOFTNET packages for Industrial Ethernet, the CP 1511 offers a low-cost access to Industrial Ethernet, such as SIMATIC S5/S7.
Ordering data CP 1511 PCMCIA card for connecting programming devices/PCs to Industrial Ethernet, including 2 adapters for AUI/industrial twisted pair and RJ45
Order No.
6GK1 151-1AA00
For SOFTNET Packages see Catalog IK 10.
3/28
Siemens ST40
Page 60
SIMATIC NET Industrial communications Interface modules for Industrial Ethernet OLE/DDE manager
WINDOWS
• OLE 2.0 and DDE-capable Windows applications for – TF protocol,
OLE 2.0/DDE
– S7 functions
SIMATIC NET OLE/DDE manager
• Available for all Windows derivatives
Simple Application Programmers Interface (SAPI)
TF library
S7 functions
• Uses an existing, installed protocol, such as TF or S7 functions.
CP 1413
CP 1411
CP 1511
Industrial Ethernet CP 1430 SIMATIC S5
CP 343-1 CP 343-1 TCP
CP 443-1 CP 443-1 TCP
SIMATIC S7-300
SIMATIC S7-400
Fig. 3/22 OLE / DDE Manager
Application
With Windows 3.x, Windows 95 and Windows NT, the OLE (object linking and embedding) communications interface for user software makes it possible to combine software components (component ware) with other OLE 2.0 applications. OLE 2.0 offers the facility for developing small, repeatedly used software components which can be marketed separately and combined with other OLE 2.0 applications. The OLE/DDE manager can be used to enable programming devices and PCs with standard applications such as – HMI systems – EXCEL 5.0 – Word for Windows 6.0 or – Visual Basic 4.0 which have the OLE 2.0 or DDE communications mechanism to communicate with other programmable controllers such as SIMATIC. Protocols TF or S7 are used for Industrial Ethernet. The main task of the OLE/DDE manager is to link Windows applications available on the market to the field of automation. Ordering data Overall packages: OLE/DDE-Manager Software for FMS/DP/TF protocol and S7 functions for linking Windows applications to SIMATIC NET automation systems: with product information and installation instructions, under Windows NT 4.0 or Windows 95 on CD ROM German/English
3
Order No.
6GK1 705-0AW13-3AA0
For further information see Catalog IK 10. OPC server Applications
• Standardized, open vendor- independent interface • OPC-capable Windows applications, (S7 functions) • For Windows NT 4.0 • Efficient data interchange • Simultaneous utilization of two or more servers by one client application • Simultaneous utilization of two or more clients on one server application.
For ordering information see OPC/PROFIBUS Siemens ST40
• OPC (OLE for process control) is in operation with Windows NT as an extension of the COM (component object model) communication interface and DCOM (distributed component object model) for the user software. • The basic principle of OPC is that OPC client applications communicate on a standardized/ open and, therefore, vendor-independent interface with the OPC server. • Facility for linking to existing OPC-capable Windows applications (Office 97 or HMI systems) on the market. 3/29
Page 61
SIMATIC NET Industrial communications TIWAY Communications network 115 Kbaud HDLC Ordering data
3
Order No.
UNILINK host adapter 115 V AC, local line/local line TIWAY ports and RS-232C/423 host ports 115 V AC, RS-232C/RS-232C TIWAY ports and RS-232C/423 host ports 220 V AC, local line/local line TIWAY ports and RS-232C/423 host ports 220 V AC, RS-232C/RS-232C TIWAY ports and RS-232C/423 host ports Personality Interface module
PPX:500-6224
Manuals Installation TIWAY system User’s
PPX:TIWAY-8106 PPX:TIWAY-8101 PPX:TIWAY-8121
UNILINK secondary adapter 115 V AC, local line/local line TIWAY ports and RS-232C/423 host ports 115 V AC, with twice RS-232C/432 host ports 220 V AC, local line/local line TIWAY ports and RS-232/432 host ports 220 V AC, with twice RS-232/RS-232C host ports
PPX:505-7111
PPX:505-7112
PPX:505-7113
PPX:505-7114
PPX:500-7111
PPX:500-7112 PPX:500-7113
PPX:505-7114
Manual English
PPX:TIWAY-8102
SIMATIC S5 PIM
PPX:500-6262
Manual
PPX:TIWAY-8126-1
UNILINK gateway for Honeywell & Foxboro Manual
PPX:TIWAY-8104-2
TIWAY network interface module (NIM) for 505 PLC 5 V DC, 2 local line ports 5 V DC, 2RS-232C ports
PPX:505-7339
Manual
PPX:TIWAY-8124
Modbus network interface module 5 V DC, local line/local line TIWAY ports and RS-232C/423 host ports
PPX:505-5184
Manual
PPX:505-8122-1
Upgrade Firmware Release 3.2
PPX:2601438-8009
Peerlink module for 505 PLC 110 VAC, local line/local line TIWAY ports and RS-232C/423 host ports
PPX:505-7354
Manual for Peerlink module
3/30
PPX:505-7340
PPX:TIWAY-8127-2
Siemens ST40