SIMATIC 505 Controllers, Catalog ST 40: B - C.E. Marks

Pages 132 to 139 of 139, from SIMATIC 505 Controllers, Catalog ST 40

The original document is the PDF (3.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Siemens 505-6660, Siemens 505-6851-A and Siemens 505-6516

Page 132

B

C.E. Marks

Page C.E. Marks

B/2

Service

B/4

Safety

B/5

General Specifications

B/6

Conditions of Sale and Delivery

B/8

B Siemens ST40

B/1

Page 133

C.E. Marks

Background

As one of the principal elements of their internal market program, the European Union (EU) is creating harmonized, European-wide standards in key product sectors which will replace divergent national standards.

The new approach directives are not standards. They are government mandated essential requirements. Standards are developed from the new approach directives by three European regional standards organizations:

For standards purposes, there are two classes of products in the EU, “regulated” and “unregulated.” Products which are subject to these new harmonized standards are referred to as regulated products.

CEN (European Committee for Standardization)

For regulated products, the EU has set out the guidelines for harmonized European-wide standards in a number of directives, commonly known as “new approach directives,” which center on the health and safety aspects of these products.

CENELEC (European Committee for Electrotechnical Standardization) ETSI (European Telecommunication Standards Institute) These bodies have stated their intention to adopt and implement existing international standards of the ISO and IEC wherever possible. To date, numerous new approach directives have been fully adopted covering such diverse areas as toys, machinery, construction products, and medical devices.

New approach directives require the affixing of the CE (Conformite’ Europeenne) indicating that the product has met all legal requirements of pertinent EU legislation. Of the existing EC new approach directives, there are two which are important to PLC products, and one that is incidental: Electromagnetic Compatability (12/31/95) Low Voltage (12/31/96) Machinery (12/31/94) - Incidental Product covered by the new approach directives cannot be sold into the EU without the CE mark after the implementation dates listed above.

B *Available soon

B/2

Siemens ST40

Page 134

General Information C.E. Certification of SIMATIC 505

EC Regulation 89/336/EEC Commonly known as the EMC Directive:

General Notes to the Manufacturer of Machines

Products which have the CE-marking meet the requirements of the ECregulations 89/336/EEC “Elektromagnetische Vertaeglichkeit” (Electomagnetic Immunity).

The SIMATIC 505 products can be used in industrial applications since they meet the following requirements:

Note: Testing for EMC compliance was performed on a typical 505 system installation. The user may be required to take additional measures to insure that EMC emissions compliance is maintained in unusual situations or configurations.

Usage

Emissions

Immunity

Industrial

EN50081-2 : 1993

EN50082-2 : 1995

Electrical Equipment of Machines Corresponding to EN 60204 (as Referred to by 89/392/ECC) commonly known as the Machinery Directive: The SIMATIC 505 automation system is not a machine in the sense of the EC regulations for machines.

That’s why there is no declaration of conformity concerning the EC regulations for machines 89/ 392/ECC. However, when used to automate a machine, The SIMATIC 505 is part of the electronic equipment of the machine and, therefore, must meet minimum

EN 60204-1

Subject/Criterion

Comment

Paragraph 4

General Requirements

Meets all requirements, if installed/mounted as installation instructions prescribe.

Paragraph 11.2

Digital input/output interface

Meets all requirements.

Paragraph 12.3

Programmamble controls

Meets all requirements if it is installed in a lockable cabinet so that unauthorized persons cannot make changes to the memory.

Paragraph 20.4

Voltage tests

Meets all requirements.

standards. The 505 equipment complies with 73/23/EEC which is The Council Directive relating to electrical equipment designed for use within certain limits (Low Voltage Guideline). The EN 60204-1 (Safety of machines, general requirement) applies to electrical equipment on machines. The following is provided to help clarify which of the EN 60204-1 criterion apply to SIMATIC 505 and how it complies.

B Siemens ST40

B/3

Page 135

Service

Our Services

Advice On all questions

Maintenance Preventative maintenance

Support We help you to help yourself

Stand-by Service Service schedule according to needs

Inspection

Telephone hotline to our specialists

Round-the-clock service 365 days a year

Repair Supply of all necessary utilities

Fast response

User support for configuration, start-up, introduction phase, etc. Your Advantages

Advice Competent assistance from a single source Reduced personnel costs Minimized training times

The rigor of everyday industrial life places high demands on equipment, especially on complex products and systems. Through painstaking care and attention, they can be made to run faultlessly, day after day, month after month. But failures can never be ruled out completely. When this happens, you may find yourself out on your own. On the other hand, you may receive prompt support - maybe you will even be able to eliminate the fault before it leads to a stoppage.

Maintenance Increased fault-tolerance

Support Fast information service

Easy maintenance budgeting

Access to our worldwide intrastructure On-site training for your personnel

With Siemens, you always have the right partner. We can support you in all matters relating to automation. You can rely on us for know-how, at the highest level, up-to-date and close-at-hand. With us, service means a lot more than just repair. We provide support for all Siemens automation products, systems, and large-scale plants, such as SIMATIC and SIMATIC NET.

Spare Parts High-speed delivery service worldwide Specialist repair service Spare parts management

Modernization Competent advice for modernization Preparation and integration of upgrade and alteration packages Functionality expansion

Central spare parts service

Stand-by Service Service during your operating hours

Spare Parts Reduced spare parts stocking costs

Less downtime

Less downtime

Modernization Repairability Access to the latest technology

Reduced personnel costs

We also offer you advice and support, stand-by services, help you to expand your plant, provide maintenance, supply spare parts, and modernize your equipment. Our service range is modular in design, with each module complementing the next, right up to the total solution. This means less risk for you, and you don’t have to pay for services that you don’t even need. Our aim is to keep you satisfied and allow you to get the best from your investments in automation.

We have built up an experienced team for exactly this purpose, with 5700 service personnel around the world. Your local Siemens sales office will be happy to answer any of your queries. In the United States call 1-800-964-4114 to be directed to the sales office nearest you. For technical assistance in the United States call 423-461-2522 outside the U.S. call 49-911-895-7000

B B/4

Siemens ST40

Page 136

Safety Safety of Electronic Control Equipment

The information given below is of a predominantly fundamental nature and applies regardless of the type of SIMATIC electronic control system. Reliability The reliability of SIMATIC programmable controllers and components is increased to a high level by taking the following extensive and cost-intensive measures during development and manufacture: • Use of high-quality components • Worst-case design of all circuits • Systematic and computercontrolled testing of components supplied by subcontractors • Burn-in of LSI circuits (e.g. processors, memories, etc.) • Measures to prevent static charge from building up when handling ESD sensitive circuits • Visual checks at key stages of manufacture • In-circuit testing of all modules, i.e. computeraided testing of components and their interaction with other components in the complete circuit • Continuous heat-run test at elevated ambient temperature over a period of several days • Careful computer-controlled final testing • Statistical evaluation of failures during testing to enable the immediate initiation of suitable corrective measures • Monitoring of the major controller components through on-line tests (parity checking in RAM, watchdog for the CPU, etc.) These basic safety requirements are sufficient to avoid or overcome the majority of possible faults. Hazard Risk In all cases where the occurrence of faults can result in personal injury or material damage, special measures must be taken to ensure the safety of equipment and its use. Special regulations relating to equipment exist for these types of applications, and they must be observed when designing a control system. Wherever electronic control systems have a responsibility to ensure safety, the measures necessary to avoid or overcome faults are determined from the risk presented by the equipment. This means that beyond a certain level of danger, the basic safety measures listed above are no longer sufficient. Additional measures (such as dualchannel control, tests, check sums, etc.) must be implemented for the controller and a certificate of approval obtained.

Distinction between safety areas and non-safety areas Almost all plants contain components which perform safety tasks (e.g. emergencyoff switch, safety guards, two-hand controls). In order to avoid treating the entire control system as a high safety risk, a distinction is generally made between a safety area and a non-safety area. In the non-safety area, no special demands are made of controllers, since the failure of electronic components does not endanger the plant nor personnel. In the safety area, however, only controllers or circuits which meet the relevant regulations can be used.

programmable controllers. 3. Controllers for predominantly high-risk equipment (such as furnaces) • The entire control system uses fail-safe technology. Important note Even where a high degree of safety has been built into an electronic control system with, for example, multi-channel design, it is nevertheless of utmost importance that the guidelines in the operating instructions be strictly adhered to, since the failure to do so may either hinder existing safety precautions or create additional hazards.

The following distinctions are generally made in practice: 1. Controllers with few safety features (e.g. machine controls) • The programmable controller takes over the function of machine controller, while the safety requirements are implemented by conventional non-electronic means. 2. Controllers for applications with a balance of safety and non-safety requirements (e.g. chemical plants, cable cars) • The non-safety area is served by standard programmable controllers, the safety area by tested fail-safe programmable controllers. • The entire plant is served by tested fail-safe

B Siemens ST40

B/5

Page 137

General Specifications Agency Approvals

The SIMATIC 505 is designed to meet both domestic and international standards. An overview follows:

Agency Approvals

UL Listed (industrial control equipment)

(All controller models and power supply)

CSA Certified (process control equipment)1 FM approved (Class I, Div. 2, Haz. Loc.) UL Canada Listed2

1 2

In addition, the system complies with applicable requirements of Verband Deutscher Elektrotechniker (VDE) 0160: Electrical Equipment, except 220 VAC Input Modules (No. PPX:505-44XX).

Except 505-2555, 2580, 2590, 2571, 2556, 2557, 2572 Applies to 505-2555, 2580, 2590, 2571, 2572, 2556, 2557

Series 505 products have been developed with consideration of the standards for programmable controllers as described in EN61131-2 Programmable Controllers

Part 2: Equipment Requirements and Tests, 1995 Information concerning product reliability and compliance to the IEC or other standards can be provided upon request. Contact your Siemens Energy & Automation, Inc., distributor.

If you need assistance in contacting your distributor, call (800) 964-4114; or write to the Customer Services Center at the following address: Siemens Energy & Automation, Incorporated 3000 Bill Garland Road P.O. Box 1255 Johnson City, TN 37605-1255 Attention: Customer Service Center

B B/6

Siemens ST40

Page 138

General Specifications Physical and Environmental Specifications

Table B-1

Physical and Environmental Specifications

Models

PPX:545-1103 CPU PPX:545-1104 CPU PPX:555-1103 CPU PPX:555-1104 CPU PPX:555-1105 CPU PPX:555-1106 CPU PPX:575-2104 CPU PPX:575-2105 CPU PPX:575-2106 CPU PPX:505-6850-A Coax, Dual Media RBC PPX:505-6851-A RS-485, Dual Media RBC PPX:505-6870 505 PROFIBUS DP RBC

Operating temperature

0 to 60˚ C (32 to 140˚ F)

Storage temperature

-40 to +70˚ C (-40 to 158˚ F)

Relative humidity

5% to 95% noncondensing

Pollution degree

2, IEC 664, 664A

Vibration

Sinusoidal IEC 68-2-6, Test Fc 0.15mm peak-to-peak, 10-57 Hz; 1.0g, 57-150 Hz Random IEC 68-2-34, Test Fdc NAVMAT P-9492 or IEC 68-2-34, Test Fdc with 0.04 g2/Hz, 80-350 Hz, and 3 dB/octave rolloff, 80-20 Hz and 350-2000 Hz at 10 min/axis

Impact Shock

IEC, 68-2-27, Test Ea; Half sine, 15g 11ms

Isolation, inputs to controller

1500 Vrms except where specified

Corrosion protection

All parts of corrosion-resistant material or plated or painted as corrosion protection

Electric Noise Immunity Conducted noise:

IEC 801, Part 4, Level 3 MIL-STD-461B, Part 4, CS01, CS02, CS06 IEC 255-4, Appendix C EEC 4517/79 Com(78) 766 Final, Part 4 IEEE 472, 2.5 kV

Radiated noise:

IEC 801 Part 3, Level 3 MIL-STD-461B, Part 4, RS01, RS02

Electrostatic discharge:

IEC 801, Part 2, Level 4 (15 kV)

B Siemens ST40

B/7

Page 139

Conditions of Sale and Delivery

Subject to the General Conditions of Supply and Delivery for Products and Services of the Electrical and Electronics Industry and to any other conditions agreed upon with the recipients of catalogs.

Export regulations The products listed in this catalog may be subject to national or U.S. export regulations. Any export requires approval by responsible authorities. Information thereon can be obtained from our acknowledgments, delivery notes and invoices.

The Automation Group’s General Conditions for the Use of Software Products Against Once-Only Payment shall apply to all software products.

We reserve the right to adjust the prices and shall charge the prices applying on the date of delivery.

The technical data, dimensions and weights are subject to change unless otherwise stated on the individual pages of this catalog. The illustrations are for reference only.

B

©1998 Siemens Energy and Automation, Inc. SIMATIC, SINUMERIK, SINEC are registered trademarks of Siemens AG. APT and PCS are trademarks of Siemens Energy & Automation, Inc. Windows is a registered trademark of Microsoft Corp. All other trademarks belong to their respective owners.

B/8