Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 31 of 35

MICROMASTER 440 0.12 kW - 250 kW Operating Instructions, pages 273 to 280

Pages 273 to 280 of 312: 6 Options; 7 Electro-magnetic compatibility (EMC)

The original document is the PDF (8.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Siemens 6SE6440-2UD13-7AA1

Page 273

Issue 10/06

6

6 Options

Options An overview of the options available for the MICROMASTER 440 is given in this section. For further information about options. please refer to the catalog or the documentation CD.

6.1

Inverter-independent options ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾

Basic Operator Panel (BOP) Advanced Operator Panel (AOP) DeviceNet module CANopen option module Pulse encoder evaluation module PROFIBUS module PC to inverter connection kit PC to AOP connection kit Operator panel door mounting kit for single inverter control AOP door mounting kit for multiple inverter control “DriveMonitor” and "Starter" commissioning tool

MICROMASTER 440 Operating Instructions 6SE6400-5AW00-0BP0

273

Page 274

6 Options

6.2

Issue 10/06

Inverter-dependent options

Frame Sizes A to F ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾

EMC filter. Class A EMC filter. Class B Additional EMC filter. Class B Low leakage Class B filter Line commutating choke Output choke Gland plate LC filter

CAUTION When using output reactors and LC filters, operation up to a pulse frequency of 4 kHz only is permitted. Please ensure that the automatic pulse frequency reductions are also deactivated. Mandatory parameter settings when using an output reactor: P1800 = 4 kHz , P0290 = 0 or 1.

Frame Sizes FX and GX ¾ Line commutating choke ¾ EMC filter. Class A (power commutating choke required) ¾ LC filter CAUTION When using output reactors and LC filters, operation up to a pulse frequency of 4 kHz only is permitted. Please ensure that the automatic pulse frequency reductions are also deactivated. Mandatory parameter settings when using an output reactor: P1800 = 4 kHz , P0290 = 0 or 1.

MICROMASTER 440

274

Operating Instructions 6SE6400-5AW00-0BP0

Page 275

Issue 10/06

7

7 Electro-magnetic compatibility

Electro-magnetic compatibility (EMC)

This Chapter contains: EMC information. 7.1

Electro-magnetic compatibility .............................................................................. 276

MICROMASTER 440 Operating Instructions 6SE6400-5AW00-0BP0

275

Page 276

7 Electro-magnetic compatibility

7.1

Issue 10/06

Electro-magnetic compatibility (EMC) All manufacturers / assemblers of electrical apparatus which “performs a complete intrinsic function and is placed on the market as a single unit intended for the end user” must comply with the EMC directive 89/336/EEC. There are three routes for the manufacturer/assembler to demonstrate compliance:

7.1.1

Self-certification This is a manufacturer's declaration that the European standards applicable to the electrical environment for which the apparatus is intended have been met. Only standards that have been officially published in the Official Journal of the European Community can be cited in the manufacturer's declaration.

7.1.2

Technical construction file A technical construction file can be prepared for the apparatus describing its EMC characteristics. This file must be approved by a ‘Competent Body’ appointed by the appropriate European government organization. This approach allows the use of standards that are still in preparation.

7.1.3

EC type examination certificate This approach is only applicable to radio communication transmitting apparatus. All MICROMASTER 440 units are certified for compliance with the EMC directive. when installed in accordance with the recommendations in Section 2.

MICROMASTER 440

276

Operating Instructions 6SE6400-5AW00-0BP0

Page 277

Issue 10/06

7.1.4

7 Electro-magnetic compatibility

EMC Directive Compliance with Imminent Harmonics Regulations From 1st January 2001 all electrical apparatus covered by the EMC Directive will have to comply with EN 61000-3-2 "Limits for harmonic current emissions (equipment input ≤ 16 A per phase)". All Siemens variable speed drives of the MICROMASTER. MIDIMASTER. MICROMASTER Eco and COMBIMASTER ranges. which are classified as "Professional Equipment" within the terms of the standard. fulfill the requirements of the standard. The allowed harmonic currents for “professional equipment” with an input power > 1 kW are not yet defined. Therefore. any electrical apparatus containing the above drives which has an input power > 1 kW will not require connection approval.

Only Frame Sizes A to C Special considerations for 250 W to 550 W drives with 230 V 1ac mains supplies when used in non-industrial applications: Units in this voltage and power range will be supplied with the following warning: ”This equipment requires supply authority acceptance for connection to the public supply network”. Please refer to EN 61000-3-12 sections 5.3 and 6.4 for further information. Units connected to Industrial Networks1 do not require connection approval (see EN 61800-3. section 6.1.2.2). The harmonic current emissions from these products are described in the table below: Table 7-1 Rating

Permissible harmonic current emissions Typical Harmonic Current (A)

Typical Harmonic Current (%)

Typical Voltage Distortion Distribution Transformer Rating rd

1 MVA

9 th

11

250 W 1AC 230 V 2.15 1.44 0.72 0.26 0.19

83

56

28

10

7

0.77

0.077

0.008

370 W 1AC 230 V 2.96 2.02 1.05 0.38 0.24

83

56

28

10

7

1.1

0.11

0.011

550 W 1AC 230 V 4.04 2.70 1.36 0.48 0.36

83

56

28

10

7

1.5

0.15

0.015

3 th

THD (%)

th

11 th

THD (%)

7

9 th

100 kVA th

7 th

THD (%)

5

5 th

10 kVA rd

3

NOTE The allowed harmonic currents for “professional equipment” with an input power > 1 kW are not yet defined. Therefore. any electrical apparatus containing the above drives which has an input power > 1 kW will not require connection approval. Alternatively. the necessity to apply for connection approval can be avoided by fitting the input chokes recommended in the technical catalogues (except 550 W 230 V 1ac units).

1 Industrial Networks are defined as those which do not supply buildings used for domestic purposes.

MICROMASTER 440 Operating Instructions 6SE6400-5AW00-0BP0

277

Page 278

7 Electro-magnetic compatibility

7.1.5

Issue 10/06

Classification of EMC performance General classes of EMC performance are available as detailed below:

Class 1: General Industrial Compliance with European Standard EN 61800-3 (EMC Product Standard for Power Drive Systems) for use in Second Environment (Industrial). Table 7-2

General industrial application EMC Phenomenon

Standard

Level

Emissions:

Radiated emissions

EN 55011

Level A1

Conducted emissions

EN 61800-3

Limits complying with EN 55011, Class A, Group 2

Electrostatic discharge

EN 61000-4-2

8 kV air discharge

Burst interference

EN 61000-4-4

Immunity:

2 kV power cables, 1 kV control cables

Radio-frequency electromagnetic field

EN 61000-4-3

26–1000 MHz, 10 V/m

Class 2: Industrial application with filter This level of EMC performance will allow the manufacturer/installer to certify their equipment themselves for compliance with the EMC directive for the industrial environment, as far as the EMC performance characteristics of the power drive system are concerned. Performance limits are as specified in the Generic Industrial Emissions and Immunity Standards EN 61000-6-4 und EN 61000-6-2. Table 7-3

With filter, for industrial applications EMC Phenomenon

Standard

Level

Emissions:

Radiated emissions

EN 55011

Level A1

Conducted emissions

EN 61800-3

Limits complying with EN 55011, Class A, Group 2

Supply voltage distortion

EN 61000-2-4

Voltage fluctuations, dips, unbalance, frequency variations Magnetic fields

EN 61000-2-1

Electrostatic discharge

EN 61000-4-2

8 kV air discharge

Burst interference

EN 61000-4-4

2 kV power cables, 2 kV control cables

Radio-frequency electromagnetic field, amplitudemodulated Radio-frequency electromagnetic field, pulsemodulated

EN 61000-4-3

80–1000 MHz, 10 V/m, 80% AM, power and signal lines

EN 61000-4-3

900 MHz, 10 V/m 50 % duty cycle, repetition rate 200 Hz

Immunity:

EN 61000-4-8

50 Hz, 30 A/m

MICROMASTER 440

278

Operating Instructions 6SE6400-5AW00-0BP0

Page 279

Issue 10/06

7 Electro-magnetic compatibility

Only Frame Sizes A to F Class 3: With filter, for residential, commercial and trade applications This level of EMC performance will allow the manufacturer/installer to certify compliance of their equipment themselves with the EMC directive for the residential, commercial and light industrial environment, as far as the EMC performance characteristics of the power drive system are concerned. Performance limits are as specified in the Generic Emission and Immunity Standards EN 61000-6-3 and EN 61000-6-1 in residential applications. Table 7-4

With filter, for residential, commercial and trade applications EMC Phenomenon Emissions:

Immunity:

Standard EN 55011

Level B

Conducted emissions

EN 61800-3

Category C1: Limit complying with EN 55011, Class B Category C2: Limit complying with EN 55011, Class A

Supply voltage distortion

EN 61000-2-4 Voltage fluctuations, dips, EN 61000-2-1 unbalance, frequency variations Magnetic fields EN 61000-4-8 Electrostatic discharge EN 61000-4-2 Burst interference

EN 61000-4-4

Radio-frequency electroEN 61000-4-3 magnetic field, amplitudemodulated Radio-frequency electroEN 61000-4-3 magnetic field, pulse-modulated

*

Level

Radiated emissions*

50 Hz, 30 A/m 8 kV air discharge 2 kV power cables, 2 kV control cables 80–1000 MHz, 10 V/m, 80 % AM, power and signal lines 900 MHz, 10 V/m 50 % duty cycle, repetition rate 200 Hz

These limits are dependent on the inverter being correctly installed inside a metallic switchgear enclosure. The limits will not be met if the inverter is not enclosed.

NOTES ¾ To achieve these performance levels. you must not exceed the default Pulse frequency nor use cables longer than 25 m. ¾ The MICROMASTER inverters are intended exclusively for professional applications. Therefore. they do not fall within the scope of the harmonics emissions specification EN 61000-3-2. ¾ Maximum mains supply voltage when filters are fitted is 460 V.

MICROMASTER 440 Operating Instructions 6SE6400-5AW00-0BP0

279

Page 280

7 Electro-magnetic compatibility

Table 7-5

Issue 10/06

Compliance Table

Frame Sizes A to F Model

Remarks

Class 1 – General industrial application 6SE6440-2U***-**A1

Units without filters, all voltages and performances. The product norm EN 61800-3 +A11 for "Variable-speed electrical drives, Part 3: EMC product standard including specific test methods” specifies limits for conducted emissions which cannot be complied with by unfiltered inverters in the second environment. Filtered inverters (as described under Class 2) must be installed for drive systems in C3 installations. The use of unfiltered inverters in industrial environments is allowed only if they are part of a system which is equipped with line filters on the higher-level supply side.

Class 2 – With filter, for industrial application 6SE6440-2A***-**A1

All units with integral Class A filters

6SE6440-2A***-**A1 with 6SE6440-2FA00-6AD1

Frame size A units 400 - 480 V with external Class A footprint filters

Class 3 – With filter, for residential, commercial and trade applications 6SE6440-2U***-**A1 with 6SE6400-2FB0*-***0

Units without filter fitted with external Class B footprint filters.

6SE6440-2A***-**A1 with 6SE6400-2FS0*-***0 or 6SE6400-2FL0*-***0

Units with fitted Class A filters and additional external Class B filters.

6SE6440-2U***-**A0 with EMC filter Class B (e.g. Fa. Schaffner) 6SE6440-2A***-**A0

Units without filter fitted with external Class A footprint filters.

All units with fitted Class A filters. For drive systems in category C2 installations, the following warning notice is necessary: In residential environments, this product may cause radio-frequency disturbances which may necessitate interference suppression measures.

* denotes any value is allowed.

Frame Sizes FX to GX Model

Remarks

Class 1 – General industrial application 6SE6440-2U***-**A1

Units without filters, all voltages and performances. The product norm EN 61800-3 +A11 for "Variable-speed electrical drives, Part 3: EMC product standard including specific test methods” specifies limits for conducted emissions which cannot be complied with by unfiltered inverters in the second environment. Filtered inverters (as described under Class 2) must be installed for drive systems in C3 installations. The use of unfiltered inverters in industrial environments is allowed only if they are part of a system which is equipped with line filters on the higher-level supply side.

Class 2 – With filter, for industrial application 6SE6440-2U***-**A1

With external EMI filter (available as an option) the limiting values of the EN 55011. Class A are fulfilled for conducted emission. (line commutating choke required)

Category C3: Drive system (PDS) with rated voltage < 1000 V. For use in second environment. Category C2: Drive system (PDS) with rated voltage < 1000 V. For use in first environment. Installation and commissioning by EMC expert only. Category C1: Drive system (PDS) with rated voltage < 1000 V. For use in first environment.

MICROMASTER 440

280

Operating Instructions 6SE6400-5AW00-0BP0