Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of MICROMASTER 440 0.12 kW - 250 kW Operating Instructions

Manual · Siemens

MICROMASTER 440 0.12 kW - 250 kW Operating Instructions

Manual312 pagesPDF 8.9 MB

Operating instructions for the Siemens MICROMASTER 440 inverter (0.12 kW to 250 kW), the series that includes the 6SE6440-2UD13-7AA1.

Download the PDF8.9 MB

Covers · 1 model

The models it covers

Summary

What is in it

Siemens operating instructions for the MICROMASTER 440 inverter family, 0.12 kW to 250 kW. It covers installation (ambient conditions, mechanical and electrical installation, EMI), the inverter functions and parameters, the BOP and AOP operator panels, commissioning, digital and analog inputs and outputs, USS serial communications, PID control, braking, V/f and vector control, troubleshooting with fault and alarm messages, specifications by order number (including the 6SE6440-2UD13-7AA1), options and EMC.

Its parts

  1. Overview
  2. Installation
  3. Functions
  4. Troubleshooting
  5. MICROMASTER 440 specifications
  6. Options
  7. Electro-magnetic compatibility (EMC)

From the manual

Key facts from this manual

Each line names its page in the PDF.

The Operating Instructions (Issue 10/06, software version 2.1) for the Siemens MICROMASTER 440 frequency inverters from 0.12 kW to 250 kW, covering the whole range including the 6SE6440-2UD13-7AA1. They cover features, installation, commissioning, functions, troubleshooting, specifications, options and EMC. They let a reader size, set up and fault-find a MICROMASTER 440 drive.

Read for this summary: pages 1 to 4, 17 to 20, 257 to 263, 270 and 273 to 274 of 312.

Device
Frequency inverter for speed and torque control of three-phase motors p. 18
Rating
6SE6440-2UD13-7AA1: 3 AC 380 V – 480 V ± 10 %, 0.37 kW (0.5 hp) CT, 0.9 kVA p. 270
Currents
6SE6440-2UD13-7AA1: CT input current 2.2 A, CT output current 1.3 A p. 270
Weight
6SE6440-2UD13-7AA1: 1.3 kg (2.9 lbs) p. 270
Frequencies
Input 47 to 63 Hz; output 0 Hz to 650 Hz p. 262
Digital inputs
6, programmable, isolated, switchable PNP/NPN p. 262
Analog inputs
2: ADC1 0 V to 10 V, 0 mA to 20 mA and –10 V to +10 V; ADC2 0 V to 10 V and 0 mA to 20 mA; usable as 7th and 8th digital inputs p. 262
Outputs
3 relays (30 V DC / 5 A resistive, 250 V AC 2 A inductive); 2 analog outputs (0 to 20 mA) p. 262
Serial interface
RS485, optional RS232 p. 263
Control methods
V/f control (0 Hz to 650 Hz) and vector control, sensorless or with encoder (0 Hz to 200 Hz) p. 262
Overload
Frame Sizes A to F, CT: 150 % for 60 s and 200 % for 3 s, every 300 s p. 262
Temperature
-10 °C to +50 °C (CT), -10 °C to +40 °C (VT); Frame Sizes FX and GX 0 °C to +40 °C; storage -40 °C to +70 °C p. 263
Protection level
IP20 p. 263
Options
Basic and Advanced Operator Panels (BOP, AOP), PROFIBUS, DeviceNet and CANopen modules, pulse encoder evaluation module p. 273

What this manual walks you through

  • Reading drive states from the SDP LEDs p. 258
  • What to check when the motor fails to start p. 259
  • Resetting the inverter to factory default parameters p. 259
  • Reading and resetting fault and alarm codes p. 260
  • Ratings, currents, fuses, cable sizes and weights by order number p. 270
  • Choosing options such as filters, chokes and operator panels p. 273, 274

Good to know

  • Disconnect the power supply before opening the equipment. p. 258
  • Repairs only by Siemens Service, authorized repair centers or qualified personnel who know the manual's warnings. p. 258
  • With output reactors or LC filters, pulse frequency is limited to 4 kHz. p. 274
  • UL listed fuses such as Class NON from Bussmann are required for use in America. p. 270
  • Motor data must suit the inverter's power range and voltage. p. 259

Questions this manual answers

How do I reset a fault on a MICROMASTER 440?

Cycle the power, press the button shown on the BOP or AOP, or use Digital Input 3 (the default). p. 260

What is the rating of the 6SE6440-2UD13-7AA1?

It runs on 3 AC 380 V – 480 V ± 10 % and is rated 0.37 kW (0.5 hp) CT, with 1.3 A CT output current. p. 270

Why won't my MICROMASTER 440 motor start?

Check that P0010 = 0, a valid ON signal is present, P0700 matches the control source and a setpoint is present. p. 259

Where are MICROMASTER 440 fault codes stored?

Fault messages are stored in parameter r0947 under their code number, with the error value in r0949. p. 260

How many inputs and outputs does the MICROMASTER 440 have?

6 digital inputs, 2 analog inputs, 3 relay outputs and 2 analog outputs. p. 262

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Foreword5
  2. Definitions and Warnings6
  3. Safety Instructions7
  4. Electrostatic Sensitive Devices (ESD)10
  5. 1 Overview17
    1. 1.1 The MICROMASTER 44018
    2. 1.2 Features19
  6. 2 Installation21
    1. 2.1 Installation after a Period of Storage23
    2. 2.2 Ambient operating conditions24
    3. 2.3 Mechanical installation26
    4. 2.4 Electrical installation33
  7. 3 Functions47
    1. 3.1 Parameters51
    2. 3.2 Operator panels for MICROMASTER70
    3. 3.3 Block diagram74
    4. 3.4 Factory setting75
    5. 3.5 Commissioning77
    6. 3.6 Inputs / outputs135
    7. 3.7 Communications144
    8. 3.8 Fixed frequencies (FF)167
    9. 3.9 Motorized potentiometer (MOP)170
    10. 3.10 JOG172
    11. 3.11 PID controller (technological controller)173
    12. 3.12 Setpoint channel181
    13. 3.13 Free function blocks (FFB)191
    14. 3.14 Motor holding brake (MHB)196
    15. 3.15 Electronic brakes202
    16. 3.16 Automatic restart211
    17. 3.17 Flying restart213
    18. 3.18 Closed-loop Vdc control215
    19. 3.19 Positioning down ramp219
    20. 3.20 Monitoring functions / messages221
    21. 3.21 Thermal motor protection and overload responses227
    22. 3.22 Power module protection232
    23. 3.23 Open-loop/closed-loop control technique235
  8. 4 Troubleshooting257
    1. 4.1 Troubleshooting with the SDP258
    2. 4.2 Troubleshooting with the BOP259
18 more lines, from page 260 on
  1. 4.3 Fault messages260
    1. 4.4 Alarm Messages260
  2. 5 MICROMASTER 440 specifications261
  3. 6 Options273
    1. 6.1 Inverter-independent options273
    2. 6.2 Inverter-dependent options274
  4. 7 Electro-magnetic compatibility (EMC)275
    1. 7.1 Electro-magnetic compatibility276
  5. Appendices281
    1. A Changing the Operator Panel281
    2. B Removing Front Covers282
    3. C Removing the I/O Board287
    4. D Removing ‘Y’ Cap288
    5. E Removing fan294
    6. F Short circuit current rating (SCCR)300
    7. G Standards301
    8. H List of Abbreviations302
    9. Index305

From the PDF’s own bookmarks.

The whole text · 35 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. Pages 5 to 95-9
  3. Pages 10 to 1610-16
  4. 1 Overview17-20
  5. 2 Installation, pages 21 to 2921-29
  6. 2 Installation, pages 30 to 3830-38
  7. 2 Installation, pages 39 to 4639-46
  8. 3 Functions, pages 47 to 5647-56
  9. 3 Functions, pages 57 to 6657-66
  10. 3 Functions, pages 67 to 7667-76
  11. 3 Functions, pages 77 to 8677-86
  12. 3 Functions, pages 87 to 9687-96
  13. 3 Functions, pages 97 to 10697-106
  14. 3 Functions, pages 107 to 116107-116
  15. 3 Functions, pages 117 to 126117-126
  16. 3 Functions, pages 127 to 136127-136
  17. 3 Functions, pages 137 to 146137-146
  18. 3 Functions, pages 147 to 156147-156
  19. 3 Functions, pages 157 to 166157-166
  20. 3 Functions, pages 167 to 176167-176
  21. 3 Functions, pages 177 to 186177-186
  22. 3 Functions, pages 187 to 196187-196
  23. 3 Functions, pages 197 to 206197-206
  24. 3 Functions, pages 207 to 216207-216
  25. 3 Functions, pages 217 to 226217-226
  26. 3 Functions, pages 227 to 236227-236
  27. 3 Functions, pages 237 to 246237-246
  28. 3 Functions, pages 247 to 256247-256
  29. 4 Troubleshooting257-260
  30. 5 MICROMASTER 440 specifications261-272
  31. Pages 273 to 280273-280
  32. Appendices, pages 281 to 288281-288
  33. Appendices, pages 289 to 296289-296
  34. Appendices, pages 297 to 304297-304
  35. Appendices, pages 305 to 312305-312

The file

Revision and size

Part no.6SE6400-5AW00-0BP0
RevisionIssue 10/06
PublisherSiemens
Pages312
PDF8.9 MB
TextText from the PDF itself.
6SE6400-5AW00-0BP0

The first pages · 3 of 312

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 312
Page 2
Page 2of 312
Page 3
Page 3of 312