3 Functions
NOTE ¾ OFF1 can be entered using a wide range of command sources via BICO parameter P0840 (BI: ON/OFF1) and P0842 (BI: ON/OFF1 with reversing). ¾ BICO parameter P0840 is pre-assigned by defining the command source using P0700. ¾ The ON and the following OFF1 command must have the same source. ¾ If the ON/OFF1 command is set for more than one digital input, then only the digital input that was last set, is valid, e.g. DIN3 is active. ¾ OFF1 is low active ¾ When simultaneously selecting the various OFF commands, the following priority applies: OFF2 (highest priority) – OFF3 – OFF1 ¾ OFF1 can be combined with DC current braking or compound braking. ¾ When the motor holding brake MHB (P1215) is activated, for an OFF1, P2167 and P2168 are not taken into account.
OFF2 The inverter pulses are immediately cancelled by the OFF2 command. This means that the motor coasts-down and it is not possible to brake in a controlled fashion. f act P1082 fmax
OFF2 t r0052 Bit02 Operation Pulse ancellation
Fig. 3-65 t
OFF2
NOTE ¾ The OFF2 command can have one or several sources. The command sources are defined using BICO parameters P0844 (BI: 1. OFF2) and P0845 (BI: 2. OFF2). ¾ As a result of the pre-assignment (default setting), the OFF2 command is set to the BOP. This source is still available even if another command source is defined (e.g. terminal as command source → P0700 = 2 and OFF2 is selected using DIN2 → P0702 = 3). ¾ OFF2 is low-active ¾ When simultaneously selecting the various OFF commands, the following priority applies: OFF2 (highest priority) – OFF3 – OFF1
MICROMASTER 440 Operating Instructions 6SE6400-5AW00-0BP0
187
Page 188
3 Functions
Issue 10/06
OFF3 The braking characteristics of OFF3 are identical with those of OFF1 with the exception of the autonomous OFF3 ramp-down time P1135. If the output frequency falls below parameter value P2167 and if the time in P2168 has expired, then the inverter pulses are cancelled as for the OFF1 command. f act P1082 fmax f2
OFF3
P2167 t P2168 r0052 Bit02 tdown,AUS3 P1135
Operation Pulse ncellation
Fig. 3-66 t t down, AUS3 = P1135 ⋅ f2 P1082
OFF3
NOTE OFF3 can be entered using a wide range of command sources via BICO parameters P0848 (BI: 1. OFF3) and P0849 (BI: 2. OFF3). ¾ OFF3 is low active ¾ When simultaneously selecting the various OFF commands, the following priority applies: OFF2 (highest priority) – OFF3 – OFF1
MICROMASTER 440
188
Operating Instructions 6SE6400-5AW00-0BP0
Page 189
Issue 10/06
3.12.4
3 Functions
Manual / automatic operation Parameter range: Warnings Faults Function chart number:
P0700, P1000, P0810, P0811 -
It is necessary to change-over from the automatic mode into the manual mode to load and unload production machines and to feed new materials (e.g. batch processing). The machine operator carries-out the preparatory activities for subsequent automatic operation in the manual mode. In the manual mode, the machine operator locally controls the machine (enters the ON/OFF command as well as also the setpoint). A changeover is only made into the automatic mode after the set-up has been completed. In the automatic mode, the control (open-loop) of the machines and production processes are handled by a higher-level control system (e.g. PLC). This operation is maintained until it is necessary to again load and unload the machine or feed new material into the machine or production process. For MICROMASTER 440, indexed parameters P0700 or P1000 and BICO parameters P0810 and P0811 are used to changeover (toggle between) the manual/automatic modes. The command source is defined using P0700 and the setpoint source is defined using P1000 (refer to Table 3-30), whereby index 0 (P0700[0] and P1000[0]) defines the automatic mode and index 1 (P0700[1] and P1000[1]) the manual mode. BICO parameters P0810 and P0811 are used to changeover (toggle between) the automatic and manual modes. These BICO parameters can be controlled from any control source (refer to Table 3-29). In so doing, in addition to P0700 and P1000, also all of the other CDS parameters are changed over (manual/automatic changeover is generalized as a CDS changeover). P0810
Command source P0700
P0811 P0700[0] = 2 Terminals
P0700[1] = 1
BOP
Setpoint source P1000
Fig. 3-67
ADC
0
Cmd Local
1
Cmd 3. CDS
USS CB MOP
Cmd Remote
P1000[0] = 2 P1000[1] = 3
Sequence control
2
Setpoint Remote
0
Setpoint Local
1
Setpoint channel
Motor control
2
FF
Setpoint 3. CDS
Changing-over using the BICO parameters P0810 and P0811
MICROMASTER 440 Operating Instructions 6SE6400-5AW00-0BP0
189
Page 190
3 Functions
Issue 10/06
Table 3-29
Examples for settings of parameter P0810
Parameter setting
Command source
P0810 = 722.2 requires P0703 = 99
Digital input 3
P0810 = 2032.15
USS at the BOP link
P0810 = 2036.15
USS at the COM link
P0810 = 2090.15
CB at the COM link
Table 3-30
Possible settings for parameters P0700 and P1000
Valu Command source (P0700) e
Valu Setpoint source (P1000) e
1
BOP (keyboard)
1
MOP setpoint
2
Terminal strip
2
Analog setpoint
4
USS at the BOP link
3
Fixed frequency
5
USS at the COM link
4
USS at the BOP link
6
CB at the COM link
5
USS at the COM link CB at the COM link
7
Analog setpoint 2
10
No main setpoint + MOP setpoint
...
6
77
Analog setpoint 2 + analog setpoint 2
MICROMASTER 440
190
Operating Instructions 6SE6400-5AW00-0BP0
Page 191
Issue 10/06
3.13
3 Functions
Free function blocks (FFB) Parameter range: Warnings Faults Function chart number: Cycle time:
P2800 – P2890 FP4800 – FP4830 128 ms
For many applications, interlocking logic is required in order to control (open-loop) the drive inverter. This interlocking logic couples several states (e.g. access control, plant/system state) to form a control signal (e.g. ON command). Previously this was implemented using either a PLC or relays. This represented additional costs for the plant or system. In addition to logic operations, increasingly, arithmetic operations and storage elements are required in drive inverters which generate a new unit from several physical quantities. This simplified PLC functionality is integrated in MICROMASTER 440 using the freely programmable function blocks (FFB). The following function blocks are integrated in MICROMASTER 440: Table 3-31 No. 3
Free function blocks Type
AND
Example AND 1 P2800 P2801[0] r2811
A 0 0 1 1
B 0 1 0 1
C 0 0 0 1 r2817
A 0 0 1 1
B 0 1 0 1
C 0 1 1 1 r2823
A 0 0 1 1
B 0 1 0 1
C 0 1 1 0
P2810 Index0 Index1
3
OR
A B
& C
OR 1 P2800 P2801[3]
P2816 Index0 Index1
3
XOR
A B
1C
XOR 1 P2800 P2801[6]
P2822 Index0 Index1
3
NOT
A B
=1 C
NOT 1 P2800 P2801[9]
P2828 Index0
MICROMASTER 440 Operating Instructions 6SE6400-5AW00-0BP0
A
1
C r2829
A 0 1
C 1 0
191
Page 192
3 Functions
Issue 10/06
No. 2
Type D-FlipFlops
Example D-FlipFlop 1 P2800 P2801[12] P2834
SET (Q=1)
Index0 Index1
D
Q r2835
Q r2836
Index2 Index3 STORE
RESET (Q=0)
1
POWER ON
SET RESET 1 0 1 0 0
3
RS-FlipFlops
D
STORE
Q
Q x x x
1 0 Qn-1 1 0 0
0 1 Qn-1 0 1 1
Q Qn-1 0 1 Qn-1 0
Q Qn-1 1 0 Qn-1 1
Out r2852
NOut 1 r2853
0 x 1 x 1 x 0 1 0 0 POWER-ON
RS-FlipFlop 1 P2800 P2801[14] P2840 Index0
SET (Q=1)
Q r2841
RESET (Q=0)
Q r2842
Index1
1
POWER ON
SET RESET 0 0 0 1 1 0 1 1 POWER-ON
4
Timer
Timer 1 P2800 P2802.0
P2850 (0.000) P2851(0) Delay Time Mode
ON Delay T
0
0
OFF Delay
P2849 Index0
0
T
1
In ON/OFF Delay T
T
Pulse Gernerator T
2
3
MICROMASTER 440
192
Operating Instructions 6SE6400-5AW00-0BP0
Page 193
Issue 10/06
3 Functions
No. 2
Type ADD
Example ADD 1 P2800 P2802[4] P2869 Index0 x1
Index1 x2
200% Result x1 + x2
Result = x1 + x2 x1 + x2 > 200% → x1 + x2 < -200% →
If:
2
SUB r2870
-200%
Result = 200% Result = -200%
SUB 1 P2800 P2802[6] P2873 Index0 x1
Index1 x2
200% Result x1 + x2
Result = x1 - x2 x1 - x2 > 200% → x1 - x2 < -200% →
If:
2
MUL r2874
-200%
Result = 200% Result = -200%
MUL 1 P2800 P2802[8] P2877 Index0 x1
Index1 x2
200% Result x1 ∗ x 2
Result =
100%
DIV x1∗ x2 100% x1∗ x2 > 200% → Result = 200% 100% x1∗ x2 < -200% → Result = -200% 100%
If:
2 r2878
-200%
DIV 1 P2800 P2802[10] P2881 200% x1
Index0 Index 1
Result x2 r2882
-200% x1 ∗ 100% X2
Result = If:
2
CMP x1∗ 100% x2 x1 ∗ 100% > 200% → x2 x1 ∗ 100% < -200% → x2
Result = 200% Result = -200%
CMP 1 P2800 P2802[12] P2885 Index0 x1
Index1 x2
CMP Out = x1 ≥ x2
2
FFB setpoints (connector settings)
Out r2886 x1 ≥ x2 → Out = 1 x1 < x2 → Out = 0
Connector Setting in % P2889 P2890
Range : -200% ... 200%
MICROMASTER 440 Operating Instructions 6SE6400-5AW00-0BP0
193
Page 194
3 Functions
Issue 10/06
The free function blocks (FFB) are enabled in two steps: 1. General enable P2800: The function "Free function blocks (FFB)" is enabled using parameter P2800 (P2800 =1). 2. Specific enable P2801, P2802: Using parameter P2801 or P2802, the particular function block is enabled (P2801[x] > 0 or P2802[x] > 0) and the sequence in which they are executed is also defined. All free function blocks are called within the 128 ms time slice (cycle time). Further, to adapt to the application, the chronological sequence in which the FFB are executed, can also be controlled. This is especially important so that the FFB are executed in the sequence which is technologically correct. Parameter P2801 and P2802 are used for the individual enable function as well as to define the priority in which the blocks are executed. The following priority levels can be assigned: 0 Inactive 1 Level 1 2 Level 2 3 Level 3 The following Table indicates that the priority decreases from the top towards the bottom (priority 1 → level) or from the right to left (priority 2 → line) (refer to Table 3-32). Table 3-32
FFB priority table low
Priority 2
3 Level 2 Level 1 Inactive 0 high low
P2802 [13] CMP 2 P2802 [12] CMP 1 P2802 [11] DIV 2 P2802 [10] DIV 1 P2802 [9] MUL 2 P2802 [8] MUL 1 P2802 [7] SUB 2 P2802 [6] SUB 1 P2802 [5] ADD 2 P2802 [4] ADD 1 P2802 [3] Timer 4 P2802 [2] Timer 3 P2802 [1] Timer 2 P2802 [0] Timer 1 P2801 [16] RS-FF 3 P2801 [15] RS-FF 2 P2801 [14] RS-FF 1 P2801 [13] D-FF 2 P2801 [12] D-FF 1 P2801 [11] NOT 3 P2801 [10] NOT 2 P2801 [9] NOT 1 P2801 [8] XOR 3 P2801 [7] XOR 2 P2801 [6] XOR 1 P2801 [5] OR 3 P2801 [4] OR 2 P2801 [3] OR 1 P2801 [2] AND 3 P2801 [1] AND 2 P2801 [0] AND 1
Priority 1
Level
Example 1: Enabling the FFB: P2800 = 1 Enabling individual FFB including assigning a priority: P2801[0] = 1 AND 1 P2801[1] = 2 AND 2 P2801[2] = 3 AND 3 P2802[12] = 2 CMP 1 P2802[13] = 3 CMP 2 The FFB are calculated in the following sequence: AND 3, CMP2, AND 2, CMP 1, AND 1
MICROMASTER 440
194
Operating Instructions 6SE6400-5AW00-0BP0
Page 195
Issue 10/06
3 Functions
Example 2: Enabling the FFB: P2800 = 1 Enabling individual FFB including assigning a priority: P2801[3] = 2 OR 1 P2801[4] = 2 OR 2 P2802[3] = 3 Timer 4 P2801[0] = 1 AND 1 The FFB are calculated in the following sequence: Timer 4, OR 1, OR 2, AND 1 The function blocks are interconnected using BICO technology (refer to Section 3.1.2.3). In so doing, the function blocks can be connected with one another as well as to other signals and quantities as long as these signals / quantities have the appropriate attribute (BO, BI, CO and CI).
MICROMASTER 440 Operating Instructions 6SE6400-5AW00-0BP0
195
Page 196
3 Functions
3.14
Issue 10/06
Motor holding brake (MHB) Parameter range:
Warnings Faults Function chart number:
P1215 P0346, P1216, P1217, P1080 r0052 bit 12 -
For drives which must be secured when powered-down to prevent them undesirably moving, the MICROMASTER brake sequence control (enabled via P1215) can be used to control the motor holding brake. Before opening the brake, the pulse inhibit must be removed and a current impressed which keeps the drive in that particular position. In this case, the impressed current is defined by the min. frequency P1080. A typical value in this case is the rated motor slip r0330. In order to protect the motor holding brake from continuous damage, the motor may only continue to move after the brake has been released (brake release times lie between 35 ms and 500 ms). This delay must be taken into account in parameter P1216 "Holding brake release delay" (refer to Fig. 3-68).
Fig. 3-68
Motor holding brake after ON / OFF1
MICROMASTER 440
196