1 Overview
Overview
This Chapter contains: A summary of the major features of the MICROMASTER 440 range. 1.1
The MICROMASTER 440....................................................................................... 18
1.2
Features.................................................................................................................. 19
MICROMASTER 440 Operating Instructions 6SE6400-5AW00-0BP0
17
Page 18
1 Overview
1.1
Issue 10/06
The MICROMASTER 440 The MICROMASTER 440 are frequency inverters for speed and torque control of three-phase motors. The various models available cover the performance range from 120 W to 200 kW (for constant torque (CT), alternatively up to 250kW (for variable torque (VT)). The inverters are microprocessor-controlled and use state-of-the-art Insulated Gate BipoIar Transistor (IGBT) technology. This makes them reliable and versatile. A special pulse-width modulation method with selectable Pulse frequency permits quiet motor operation. Comprehensive protective functions provide excellent inverter and motor protection. With the factory default settings, the MICROMASTER 440 is suitable for many variable speed applications. Using the functionally grouped parameters, the MICROMASTER 440 can adapted to more demanding applications. The MICROMASTER 440 can be used in both 'stand-alone' applications as well as being integrated into 'Automation Systems'.
MICROMASTER 440
18
Operating Instructions 6SE6400-5AW00-0BP0
Page 19
Issue 10/06
1.2
1 Overview
Features
Main Characteristics ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾
Easy installation Easy commissioning Rugged EMC design Can be operated on IT line supplies Fast repeatable response time to control signals Comprehensive range of parameters enabling configuration for a wide range of applications Simple cable connection Output relays Analog outputs (0 – 20 mA) 6 Isolated and switchable NPN/PNP digital inputs 2 Analog inputs: ♦
¾ ¾ ¾ ¾ ¾ ¾
ADC1: 0 – 10 V, 0 – 20 mA and -10 to +10 V
♦ ADC2: 0 – 10 V, 0 – 20 mA The 2 analog inputs can be used as the 7th and 8th digital inputs BICO technology Modular design for extremely flexible configuration High switching frequencies (drive inverter specific up to 16 kHz) for low-noise motor operation Internal RS485 interface (port) Detailed status information and integrated message functions
MICROMASTER 440 Operating Instructions 6SE6400-5AW00-0BP0
19
Page 20
1 Overview
Issue 10/06
Performance Characteristics ¾ Vector Control ♦
Sensorless Vector Control (SLVC)
♦ Vector Control with encoder (VC) ¾ V/f Control ♦
Flux Current Control (FCC) for improved dynamic response and motor control
♦ Multi-point V/f characteristic Automatic restart Flying restart Slip compensation Fast Current Limitation (FCL) for trip-free operation Motor holding brake Built-in DC injection brake Compound braking to improve braking performance Built-in braking chopper (Frame Sizes A to F) for resistor braking (dynamic braking) ¾ Setpoint input via: ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾
♦
Analog inputs
♦
Communication interface
♦
JOG function
♦
Motorized potentiometer
♦ Fixed frequencies ¾ Ramp function generator ♦
With smoothing
♦ Without smoothing ¾ Technology controller (PID) ¾ Parameter set switch-over ♦ ¾ ¾ ¾ ¾
Motor data sets (DDS)
♦ Command data sets and setpoint sources (CDS) Free Function Blocks DC link voltage controller Kinetic Buffering Positioning Ramp down
Protection characteristics ¾ ¾ ¾ ¾ ¾ ¾
Overvoltage/undervoltage protection Overtemperature protection for the inverter Ground fault protection Short-circuit protection i2t thermal motor protection PTC/KTY84 for motor protection
Options ¾ Refer to Chapter 5